Records from 1999 to 2016. Most recent: inspection, 13 May 2016.
Inspection history · 35
13 May 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876083
12 August 2014
MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 4952286
20 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228431
21 January 2011
Type not recorded
No type recorded · Activities Europe · Activity 3930272
16 September 2010
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · DAPI Audit
Physical examination · Activities Europe · Activity 3850877
20 March 2009
Drydock Exam · Deficiency Check
Physical examination · Activities Europe · Activity 3436865
3 November 2008
MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 3356224
28 July 2008
Administrative Inspection
Administrative · Activities Europe · Activity 3281866
22 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3132380
13 September 2007
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3056572
13 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3114478
8 May 2007
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2924945
20 July 2006
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2725439
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502081
22 September 2005
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2650498
22 August 2005
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2513604
27 July 2005
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2442062
13 May 2005
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2356941
11 September 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2182300
8 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2064813
23 June 2003
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1824778
17 June 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1828193
13 June 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1828232
17 October 2002
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1695576
24 September 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1681220
26 November 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384933
5 January 2001
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465609
19 October 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365996
1 October 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361138
25 June 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089434
7 May 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458628
20 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 79366
20 April 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790860
20 January 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1336505
6 January 1999
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386419
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 11 November 2008
Resolved
Prove proper operation of rudder angle indicator in machinery space. Item reported cleared via E-mail dated 08Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 13 September 2009
Resolved 19 April 2009
Resolution: Inspected
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 11 November 2008
Resolved
Prove proper operation of port generator reverse power relay. Item reported cleared via E-mail dated 28Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 13 September 2009
Resolved 19 April 2009
Resolution: Inspected
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 11 November 2008
Resolved
Provide original/certified true copy of ISM Safety Management Certificate onboard. Item reported cleared via E-mail dated 08Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 13 September 2009
Resolved 19 April 2009
Resolution: Inspected
Communications › Radio Communications › EPIRB
Issued 13 September 2007
Resolved
Properly conduct and log monthly EPIRB checks.
Due 13 October 2007
Resolved 21 September 2007
Accommodation/Occupational Safety › Messroom › Location
Issued 13 September 2007
Resolved
Properly label or placard location of range disconnect near the range in the galley.
Due 13 October 2007
Resolved 21 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 13 September 2007
Resolved
Repair/replace inoperable general alarm visual indicator in machinery space.
Due 13 October 2007
Resolved 21 September 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 May 2007
Resolved
Provide ABS documentation proving satisfactory NDT of the 18"x18" insert located on stbd side of vsl and NDT of newly installed rudder post casing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 May 2007
Resolved
After completing drydock, proceed directly to Ciudad del Carmen to complete drydock worklist and COI inspection. No passengers or cargo permitted during transit.
Action required: 705 - Other - as specified
Resolved 18 May 2007
Resolution: Drydock repairs took longer than expected and COI originally scheduled for following week in Carmen cancelled. Got confirmation from company rep that all drydock related items on worklist completed. Worklist should be verified during rescheduled COI.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 July 2006
Resolved
Make watertight bulkhead wire conduit penetrations watertight on stbd side in engine room fwd bulkhead and next forward watertight bulkhead.
Condition: Improper Installation
Due 20 August 2006
Resolved 13 September 2007
Construction/Loadline › Structures › Deck Plating
Issued 20 July 2006
Resolved
Repair hole in deck above CO2 bottle storage.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 13 September 2007
Construction/Loadline › Structures › Deck Plating
Issued 20 July 2006
Resolved
Make wiring penetration in main deck aft of port side ventilator watertight.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 13 September 2007
Electrical › Lighting (service) › Switch
Issued 20 July 2006
Resolved
Provide proper switch for stern light on nav light panel.
Condition: Improper Installation
Due 20 August 2006
Resolved 13 September 2007
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 20 July 2006
Resolved
Provide new harnesses for working aloft/over the side (expired service life).
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 13 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 20 July 2006
Resolved
Repair general alarm lights in e/r and generator room.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 13 September 2007
Lifesaving › Inflatable Liferafts › Not on Board
Issued 22 August 2005
Resolved
Vessel limited to carrying eighty-five (85) persons total onboard until it is proven that liferafts onboard support ninety( 90) persons.
Due 22 September 2005
Resolved 22 September 2006
Electrical › Electrical Distribution System (service)
Issued 24 September 2002
Resolved
Repair reverse power relay and provide proof of proper operation. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 26 September 2002
Engineering › Steering Gear System
Issued 24 September 2002
Resolved
Adjust limit switch on starboard rudder stop. LEGACY COMPONENT DESC: Interlock
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 26 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 September 2002
Resolved
Replace deteriorated fuel hose on starboard main engine. LEGACY COMPONENT DESC: hose, fuel
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 24 September 2002
Deck/Cargo › Ballast
Issued 24 September 2002
Resolved
Repair ball vent on anti-roll tank. LEGACY COMPONENT DESC: Vents
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 10 October 2002
Engineering › Fuel Oil Service System
Issued 24 September 2002
Resolved
Replace two (2) ball valves of fuel tanks, existing check valves are cracked. LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 10 October 2002
Accommodation/Occupational Safety
Issued 5 January 2001
Resolved
Provide a T handle wrench for the fore peak reach rod.
Condition: Unknown
Due 5 January 2001
Resolved 19 January 2001
Lifesaving
Issued 5 January 2001
Resolved
Remove hydraulic oil in void containing bow thruster equipment.
Condition: Unknown
Due 5 January 2001
Resolved 19 January 2001
Accommodation/Occupational Safety
Issued 5 January 2001
Resolved
Provide a new fore peak suction valve and modify the reach rod to ensure proper operation.
Condition: Unknown
Due 5 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 5 January 2001
Resolved
Reweld unwelded frame on the port sideshell longitudinal angle iron in the fore peak.
Condition: Unknown
Due 5 January 2001
Resolved 19 January 2001
Construction/Loadline
Issued 19 October 2000
Resolved
Demonstrate proper operation of generator room bilge alarm to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 19 October 2000
Resolved
Make proper repairs to crack in aft anti roll tank in generator room to thesatisfaction of the attending marine inspector.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Lifesaving
Issued 1 October 1999
Resolved
Provide placards or other cards containing instruction for launching and inflating inflatable liferafts. Post in conspicuous place by each raft._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 1 October 1999
Resolved
Provide life jacket donning instruction placard for both type lifejackets onboard.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 1 October 1999
Resolved
Update station bill (addtional POB and liferafts vs lifefloats).
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Construction/Loadline
Issued 20 April 1999
Resolved
VSL PROHIBITED FROM OPERATING UNTIL REPAIRS TO BOW ARE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR. VSL AUTHORIZED TRANSIT DURING DAYLIGHT HOURS TO NEW IBERIA FOR REPAIRS.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Navigation
Issued 6 January 1999
Resolved
MAKE OPERABLE THE VESSELS BOW THRUSTER.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Documentation
Issued 6 January 1999
Resolved
PROVIDE APPROVED PLANS FOR THE COMPUTER BASED PROPULSION CONTROLS AS PER 46 CFR 177.202(b)(3)(i) TO DEMONSTRATE COMPLIANCE WITH 46 CFR 61.40-3 AND THE REQUIREMENTS SET FORTH IN 46 CFR 184.620(c).
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Fire Fighting
Issued 6 January 1999
Resolved
CONDUCT IN THE PRESENCE OF THE COGNIZANT [name withheld], MAN OVERBOARD, AND FIRE FIGHTING DRILLS AS REQUIRED BY 46 CFR 185.52 AND 185.524 PRIOR TO THE CARRIAGE OF CARGO OR PASSENGERS.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999