Records from 1999 to 2026. Most recent: inspection, 12 February 2026.
Inspection history · 84
12 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8309756
22 April 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8117014
13 January 2025
Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8062970
17 June 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7937182
24 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7918710
30 January 2024
Security Plan Review - VSP · ISPS Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853698
6 December 2023
Security Plan Review - VSP · Exemption · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853004
17 August 2023
Excursion Permit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7770862
15 August 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7770729
31 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7661450
21 September 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7563942
25 January 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7385407
8 October 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7329322
14 September 2021
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7313028
21 April 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7179797
18 March 2021
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7159508
26 October 2020
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7084450
4 February 2020
Administrative Inspection · Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6901665
26 February 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6633781
6 February 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6621048
30 July 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6492615
18 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6394243
5 April 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6386705
28 March 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6114050
9 March 2017
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6093737
1 February 2016
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5809733
14 January 2016
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5798383
13 November 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5762940
3 March 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5077929
25 November 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5029879
24 October 2014
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5011690
9 October 2014
In-Service Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5005897
19 August 2014
Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4962457
26 March 2014
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4823386
4 November 2013
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4738468
27 March 2013
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4557380
5 February 2013
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4528839
30 January 2013
Plan Review (Other than "T")
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4526330
27 November 2012
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4492381
5 March 2012
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4258013
27 April 2011
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3996693
10 March 2011
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3962398
11 January 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3922934
12 March 2010
MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3694994
22 February 2010
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3684130
27 October 2009
Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3623275
28 May 2009
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3488981
18 February 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3419857
5 January 2009
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3389146
4 January 2009
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3388828
4 January 2009
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3389020
10 April 2008
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3181278
16 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2951619
15 March 2007
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2888528
27 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2809349
19 September 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2782424
18 May 2006
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2653613
25 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2633266
13 June 2005
Periodic Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2389137
21 March 2005
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2316049
29 July 2004
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2149614
2 July 2004
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2119159
28 April 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2059099
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2013638
16 January 2004
Drydock Extension
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1986890
1 July 2003
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1834049
17 March 2003
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1758533
13 March 2003
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1774348
1 February 2003
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1738405
9 May 2002
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1615175
2 April 2002
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1600013
26 December 2001
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1473891
20 June 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441873
16 January 2001
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1435134
30 December 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 487567
22 September 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 20035
25 July 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 760768
24 July 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 201064
24 July 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 819991
11 January 2000
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1378923
19 July 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1104647
27 May 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 802280
30 January 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 154246
22 January 1999
Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390910
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessels discharged unknown amount of hydraulic fluid during the sea trial and cause of the discharge is due to VOITH propulsion unit leaking due to the mechanical failure. Vessel is not permitted to transit until repairs are made to the satisfaction of the attending surveyor.
In accordance with CVC Policy letter 17-10, the above deficiency may be cleared by the operating company's TPO. TPO must submit a report to the cognizant OCMI within 72 hours clearing deficiency.
Action required: 705 - Other - as specified
Resolved 19 April 2025
Resolution: Satisfactory repairs were made to the vessel drive system and sea trials were conducted with ABS on board.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2021
Resolved
Resolve ground fault indicated on switchboard ground detection system.
46 CFR 111.01-1(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 23 June 2021
Resolution: Report of repair received.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 18 March 2021
Resolved
The forward escape hatch did not have a hydraulic lift to assist in lifting the hatch from below. Demonstrate the emergency escape hatch can be readily opened from below.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Hatch can now be readily opened from below.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 March 2021
Resolved
"A class" doors that are self-closing need to fully latch when closed. Demonstrate that the self closing door leading to the engine room, and into the galley can fully latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Self-closing doors fully close and latch when shut.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 March 2021
Resolved
Holdback hooks, or other means of permanently holding fire doors open are not permitted, unless of a magnetic type that can be operated remotely. All fire doors need
holdbacks removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: Removed holdback hooks.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 18 March 2021
Resolved
Prove load line and fresh water mark is in the correct location on the hull, and verify the certificate accurately depicts the load line. Load line needs to be made permanent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2021
Resolved 29 March 2021
Resolution: Load line matches Load Line Certificate and has been made permanent.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 18 March 2021
Resolved
A ship of 300 gross tons or more must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow,and fill pipe with at least 1/2 barrel capacity. The areas under and around the port and starboard fuel oil and lubricating oil tank vents, overflows, and fill pipes is not enclosed. Demonstrate the deck area can be fully enclosed or provide a fixed containing system for at least 1/2 barrel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2021
Resolved 24 March 2021
Resolution: Port engineer sent volume calculation for enclosed deck area and demonstrated how vessel closes scuppers and deck drains.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 October 2020
Resolved
Complete satisfactory dry dock exmainiation prior to operation of vessel. Vessel is scheduled for dry dock at Dakota Creek Industries for March 15,2021. 46 CFR 91.40-3(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2021
Resolved 18 March 2021
Resolution: Vessel completed drydock exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2020
Resolved
All pressure vessels must be provided with protective devices. Provide objective evidence that relief devices are functioning as designed for pressure intended.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2020
Resolved 24 February 2020
Resolution: Both relief valves operated properly.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 4 February 2020
Resolved
A vessel that is certificated for coastwise service beyond 3 nautical miles from land is required to have a properly operating oily water separator to control the discharge of oil/oily mixtures into the sea. The vessel is restricted from operating beyond 3 nautical miles from land.
33 CFR 151.09(a)(3)
33 CFR 151.10
Action required: 705 - Other - as specified
Resolved 16 June 2021
Lifesaving › Inflatable Liferafts › Float Free
Issued 9 March 2017
Resolved
Make permanent arrangement to enable life rafts to be float free.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 April 2017
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 14 January 2016
Resolved
Loose wiring caused the main diesel generator #1 to shut down.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 19 January 2016
Resolution: A loose wire was found properly connected to allow the MDG to be fully functional.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 March 2015
Resolved
Provide current Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Due 10 April 2015
Resolved 16 March 2015
Resolution: Vsl not required to have GMDSS thus not required to have certificate.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 27 November 2012
Resolved
Make permanent repairs to broken/chipped teeth on starboard MDE fly wheel.
Action required: 705 - Other - as specified
Due 1 January 2014
Resolved 31 December 2013
Resolution: Fly wheel replaced while in shipyard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 March 2012
Resolved
Make changes to the placarding to show the proper time delay installed in the system.
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 5 March 2012
Resolution: Corrected to coincide with time delay.
Engineering › Compressed Air System (start air) › Valve
Issued 5 March 2012
Resolved
Repair/Renew relief valve to ensure proper operation at 250 psi as indicated on valve body.
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 5 March 2012
Resolution: On the spot replacement.
Engineering › Fuel Oil Service System › Hose
Issued 5 March 2012
Resolved
Install chaffing gear on fuel line forward side of Port MDE.
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 5 March 2012
Resolution: Installed chaffing gear on line.
Fire Fighting › Fire Hoses › Length
Issued 5 March 2012
Resolved
Ensure all fire stations are outfitted with 50 foot fire hoses.
Action required: 705 - Other - as specified
Due 15 March 2012
Resolved 15 March 2012
Communications › Audible Communications › Bell
Issued 30 March 2011
Resolved
Install audible (General Alarm) bells/ringer in the forward workshop/storeroom and the line locker. Until installation is made personnel making access to the spaces will maintain communications with the watch via hand held radio.
Action required: 705 - Other - as specified
Due 30 April 2011
Resolved 27 April 2011
Resolution: General alarm bells installed in the line locker and workshop.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 March 2011
Resolved
Ensure automatic valve closure at 15ppm and verify operation of the OCMI.
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 8 April 2011
Resolution: Installed new valves and OCM. System operates properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2011
Resolved
Remove wire-nuts from outboard side of port generator and replace with permanent type connector.
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 16 March 2011
Electrical › Electric Generation Source (service) › Generator
Issued 10 March 2011
Resolved
Renew pressure line on the outboard side of the starboard generator.
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 16 March 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 February 2010
Resolved
Make permanent repairs to soft patch in OWS line.
Action required: 705 - Other - as specified
Due 15 March 2010
Resolved 12 March 2010
Resolution: Soft patch removed and new line installed.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 23 February 2010
Resolved
Lable or mark emergency lighting in engine room with "E" designator.
Action required: 705 - Other - as specified
Due 15 March 2010
Resolved 12 March 2010
Resolution: E-lights properly marked.
Accommodation/Occupational Safety › Ventilation › General
Issued 23 February 2010
Resolved
Change placarding for indicating lights for ventilation shut downs so the do not indicate, "CO2 system activated."
Action required: 705 - Other - as specified
Due 15 March 2010
Resolved 12 March 2010
Resolution: Installed new placard to agree with operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 22 February 2010
Resolved
Make fixed CO2 discharge directions agree with levers.
Action required: 705 - Other - as specified
Due 15 March 2010
Resolved 12 March 2010
Resolution: Corrected handles instruction to agree with operation.
Construction/Loadline › Hull › Side Shell
Issued 4 January 2009
Resolved
Submit written repair proposal for temp and permanant repairs to be made and approved by attending CG inspector.
Action required: 705 - Other - as specified
Resolved 12 January 2009
Construction/Loadline › Hull › Weld
Issued 19 September 2006
Resolved
Make permanent repair to gouged out steel where temporary hangers were removed in port day tank.
Due 4 October 2006
Resolved 20 March 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 June 2005
Resolved
FCP needs to be stamped and reviewed.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: REVIEWED AND APPROVED.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 June 2005
Resolved
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: EAP INFO POSTED.
Lifesaving › Immersion Suits › Marking
Issued 13 June 2005
Resolved
Stencil vessel name on immersion.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: MARKINGS PROVIDED.
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 13 June 2005
Resolved
Stencil name on box.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: LINE THROWING APPARATUS STENCILED.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 13 June 2005
Resolved
Provide line diagram antransfer instructions for fuel oil system.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: LINE DIAGRAM PROVIDED.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2005
Resolved
Stencil name on ring lifebuoys.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: LIFEBUOYS STENCILED.
Engineering › Diesel Engine (propulsion-electric) › Air Cleaner
Issued 13 June 2005
Resolved
Repair leaking fuel filters.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 July 2005
Resolution: REPAIRS MADE SATISFACTORILY.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 July 2004
Resolved
Inoperable Oily Water Seperator. Vessel has never used OWS except for inspections.
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 29 July 2004
Resolution: Repaired to the satisfaction of the attending CG marine inspector. Vesssel uses local facility for pumping all bilge and slop tanks, that''s the reason the vessel only uses the OWS during inspections.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 2 July 2004
Resolved
Vessel doen't have current endorsement from ABS surveyor.
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 29 July 2004
Resolution: To the satisfaction of the attending CG marine inspector.
Fire Fighting › Fire Hoses › Condition
Issued 2 July 2004
Resolved
Fire hoses need to be tested at 100 psi and documented.
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 29 July 2004
Resolution: To the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service)
Issued 1 July 2003
Resolved
Provide suitable covers for exposed breaker slots in distribution panel P-204. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 17 July 2003
Resolution: Breaker slots covered.
Lifesaving › Line-Throwing Appliances
Issued 1 July 2003
Resolved
Provide one additional line cartridge for line throwing gun. LEGACY COMPONENT DESC: Lines
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 17 July 2003
Resolution: Provided one additional line cartridge to make a total of four.
Communications › Alarms/Indicators
Issued 1 July 2003
Resolved
Provide proof of satisfactory test of fire detection system. LEGACY COMPONENT DESC: Fire Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 17 July 2003
Resolution: Provided documentation of fire detection system test.
Pollution Prevention/Response › Prevention Equipment
Issued 2 April 2002
Resolved
Demonstrate proper operation of Oily Water Separator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 9 April 2002
Resolution: Witnessed satisfactory operation of oily water separator
Engineering
Issued 2 April 2002
Resolved
Provide proof of completed testing of automation and monitoring systems. LEGACY COMPONENT DESC: Automation
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 9 April 2002
Resolution: Verified vessel had completed satisfactory testing of automation and monitoring system.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 2 April 2002
Resolved
Replace flame screens in both fuel tank vents.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2002
Resolution: Installed new flame screens in both fuel tank vents.
Lifesaving
Issued 24 July 2000
Resolved
Prove proper operation of automation procedures prior to vessel operations.
Condition: Unknown
Due 28 July 2000
Resolved 26 July 2000
Documentation
Issued 22 January 1999
Resolved
Provide "Periodic Safety Test Procedures" within 90 days of 22JAN99.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999