MAURY USCG vessel records
← All vessels

CETACEA

CETACEA is a 1999 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 2016, most recently in June 2026, along with 43 deficiencies and 9 casualty investigations between 2004 and 2024.

Records from 2004 to 2026. Most recent: inspection, 8 June 2026.

Built
1999
Last inspected
8 June 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 June 2026
…with no type recorded44
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY8216
486258
Flag
UNITED STATES
Maury page id
psix-486258

Documentation record

Registered dimensions (L × B × D)83.1 ft × 29.8 ft × 9.6 ft
Registered tonnagegross 88 / net 59
ITC dimensions (L × B × D)83.1 ft × 29.8 ft × 9.6 ft
ITC tonnagegross 165 / net 73
BuilderDUCLOS CORP DBA GLADDING-HEARIN SHPBLDG · SOMERSET, MA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 5 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it165 - Convention (Subpart B), Gross Ton
88 - Regulatory (Subpart C or D), Gross Ton
73 - Convention (Subpart B), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

X Passenger (Inspected) · MISLE 360058 · 23 September 2022 · activity 7565414ASTERIA Passenger (Inspected) · MISLE 478192 · 23 September 2022 · activity 7565414

Inspection history · 80

8 June 2026 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8394918
1 June 2026 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8390072
5 March 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8311546
28 May 2025 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8139505
15 January 2025 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8066829
5 December 2024 Plan Review (Other than "T")
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8145924
14 November 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8034196
5 June 2024 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7929006
5 June 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7929346
1 May 2024 Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7926736
20 December 2023 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7830114
1 September 2023 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7782582
1 September 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7786421
16 August 2023 Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7769669
29 June 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7723988
27 April 2023 Hull Examination · Internal Structural Exam · Examination of Repairs · Construction Oversight · Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7675122
23 January 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7616397
23 September 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7565414
12 July 2022 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7465187
27 January 2022 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7376593
12 May 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7195622
25 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7145993
3 December 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7105452
21 May 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6957050
9 January 2020 MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6886147
10 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6870995
24 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840873
13 March 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6641568
4 January 2019 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6604753
12 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6539007
3 July 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6466105
29 March 2018 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384775
8 January 2018 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6334658
31 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6298761
31 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6298764
28 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6296723
28 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6297670
2 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6279343
30 August 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6256733
26 June 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189661
26 June 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6191497
21 June 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6182336
31 May 2017 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6163696
16 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6147432
16 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6147441
16 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6147445
16 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6147449
16 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6147454
12 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144633
12 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144642
12 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144661
12 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144666
10 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6143549
10 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6143550
10 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6143551
10 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6143552
27 April 2017 Internal Structural Exam · Drydock Extension
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133660
29 March 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6113958
9 December 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6055071
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036617
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036628
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036715
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036722
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036729
21 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914750
21 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914754
21 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914766
21 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914769
21 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914778
13 April 2016 Deficiency Check · Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5853478
26 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5827142
19 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5818618
19 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5818621
19 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5818625
19 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5818630
12 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5795844
12 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5795852
12 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5795858
12 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5795878
12 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5795885

Deficiency record · 43

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 01 Ring Buoy had a deteriorated grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 18 March 2026
Resolution: Life buoy replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests: For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by NFPA 10. Vessels servicing record indicated portables failed due to expired hydro test dates however service tags indicated that extinguishers were inspected and service ready. Provide documentation from the servicing company that all portable extinguishers have passed full inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 12 March 2026
Resolution: O/O provided updated fire service report with new extinguisher details.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 November 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Pitting was observed in #2 starboard side void space, underneath the bilge suction point. Weld fracture observed in #3 starboard side void space, forward frame on outboard side. Weld fracture observed in #4 starboard side void space, forward of 3rd transverse frame on outboard side. 4" fracture observed in hull around exhaust port in starboard side lazarette space. This fracture is roughly about 5' above the waterline. Assess necessary repairs to be done prior to 2025 hull exam credit. Submit repair proposal prior to commencing repairs.
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 9 June 2025
Resolution: All damaged aluminum was replaced or re-welded.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 December 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Several transition joints between the port hull and the deck/superstructure are loose or have broken hardware. Submit a repair proposal to examine, tighten, and repair all transition joints.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2024
Resolution: wasted and loose hardware replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 December 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Both the port and starboard main longitudinal support beams between the hulls and the deck/superstructure are pitted and are holed through in multiple locations, especially the aft portions. Submit a repair proposal. Assess and make permanent repairs as necessary prior to 2025 Hull Exam credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 2 September 2025
Resolution: Repairs will be conducted at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 December 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. On the port side in the vicinity of the #3 void scuttle, the main transverse support beam has a cracked weld by mount to deck. Submit a repair proposal. Assess and make permanent repairs as necessary prior to 2025 Hull Exam credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 6 June 2025
Resolution: repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 December 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. In the port #2 void, there are multiple cracked welds inboard and outboard in the vicinity of the 3rd frame aft of the fwd bulkhead. Submit a repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2024
Resolution: repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 December 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. On the port side in the vicinity of the #3 void, the deck stiffener has multiple cracked welds. Submit a repair proposal. Assess and make permanent repairs as necessary prior to 2025 Hull Exam credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 9 June 2025
Resolution: Deck stiffeners were re-welded.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 December 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 January 2024
Resolution: valid certificate onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 December 2023 Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Due to safety concerns in regards to deficiency items 1-3, underway drills and DVTP's were not observed by the attending [name withheld] and underway drills in the presence of MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2024
Resolution: drills, steering tests, and DVTP's completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 September 2023 Resolved
The main steering gear and rudder stock must be capable of moving the rudder from 35 degrees on either side to 35 degrees on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed. While underway with passengers to Salem, vessel reported a loss of maneuverability as steering gear froze in the hard over port position, preventing the vessel from safely maneuvering. Once repairs are affected, prepare and have vessel ready to perform sea trials to the satisfaction of attending Marine Inspector. 46 CFR 58.25(b)2
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2023
Resolved 2 September 2023
Resolution: Conducted satisfactory sea trials after Port Engineer re-aligned steering control arms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2023 Resolved
Propulsion machinery must be capable of operating at constant marine load. Vessel experienced a loss of propulsion of the starboard engine. Affect necessary repairs and conduct satisfactory sea trial in presence of Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 16 August 2023
Resolved 16 August 2023
Resolution: Conducted satisfactory sea trials.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 January 2023 Resolved
A storage cylinder must be securely fastened, support, and protected against damage. CO2 cylinder bracket in starboard lazarrette is wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2023
Resolution: Operator installed new bracket on CO2 bottle mount.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2023 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Battery covers were not properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2023
Resolution: Verified covers were properly secured.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 January 2023 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. During vessel's annual inspection, Marine inspector noticed pitting in the forward transverse bulkhead in Port Lazarette. Vessel shall address pitting at next scheduled drydock examination.
Action required: 705 - Other - as specified
Resolved 20 October 2023
Resolution: locking cap installed
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 27 January 2022 Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. IAW 46 CFR 116.202 the owner shall submit for approval to the Marine Safety Center, three copies of the following plan, to Marine Safety Center: Structural fire protection details. Post approved fire control plan prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
Resolution: Verified and approved safety and fire plan.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 January 2022 Resolved
On a vessel without overnight accommodations, or with overnight accommodations for not more than 49 passengers, the fire pump must be capable of delivering a single hose stream from the highest hydrant, through the hose and nozzle required by § 118.320 of this part, at a pitot tube pressure of 345 kPa (50 psi). Unable to demonstrate requirement, due to frozen pipes. Demonstrate 50 psi from the highest hydrant, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2022
Resolution: Tested fire pump sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2022 Resolved
Each vessel must be provided with bilge pumps in accordance with 46 CFR 56.50-55, which states: each hull of a vessel with more than one hull must have at least two means for pumping the bilges in each hull. The port side bilge pump was unable to pump a starboard void space. Vessel cannot carry any passengers until proper operation of the bilge pump and cross connect are verified.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2022
Resolution: Tested bilge suction sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 January 2022 Resolved
Except as allowed by paragraphs (b),(c) and(d) of this section, each vessel certificated to operate on a limited coastwise route shall be provided with the survival craft required by §§ 117.204 (a) through (d) of this part, as applicable. All of the vessel's IBAs were removed for annual servicing. Vessel is limited to a route within one mile from shore until the IBAs are re-installed onboard to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: Inspected installation of IBAs,sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 January 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First- Aid kit medications were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: removed expired medications and replaced with new in kind
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: Provided portable lights as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2022 Resolved
Cable/Wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Wire & Cables were installed with zip ties instead of metal brackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: Properly supported cables.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Expose bonding at the Port side ENG, and Control panel on STDB engine room was not blanked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: made electrical enclosure safe
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 27 January 2022 Resolved
Inspection of all accessible parts of the exterior and interior of the hull, watertight bulkheads and weather deck shall be made. Cracks were found on welds in the starboard #2 void, located midway up on the most aft frame where the longitudinal is welded,on both the outboard and inboard sides.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 1 March 2022
Resolution: Repairs inspected, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 January 2022 Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The lettering on the upper deck life jacket stowage containers are faded and not clearly legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: Installed new labels for life jacket storage
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2022 Resolved
Each ring life buoy with a waterlight must have a lanyard of at least 3 feet, but more more than 6 feet securing the waterlight around the body of the ring life bouy. The lanyard exceeded 6 feet and needs to be replaced due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 3 February 2022
Resolution: Installed new line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2022 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than than a paint locker). 10 gallons of hydraulic fluid ware stored at the Bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 18 February 2022
Resolution: no oil stored in containers on the pilot house.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 December 2020 Resolved
Penetrations in A Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. The CO2 switch cable going through the starboard side engine room overhead fire boundary (rox blocks) is compromised and will not prevent the passage of flame and smoke.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 15 January 2021
Resolution: Operator replaced compromised block with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 December 2020 Resolved
Piping in vital systems shall comply with the provisions in Subchapter F. The vessels bilge pick up lines in both hulls have approximately 2 feet of rubber hose vice metal pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 15 January 2021
Resolution: Operator replaced rubber hose with fixed piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2020 Resolved
Connections to batteries must be made with permanent type connectors. The connections to both port and starboard 24V batteries are connected by wing nuts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 15 January 2021
Resolution: Operator replaced wing nuts with permanenent nuts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 January 2020 Resolved
A vessel must be provided with a piping system that meets §56.50-50 in subchapter F of this chapter. Port hull bilge line to the #2 void space leaks water into the engine room while the bilge pump in in operation. Determine source of leak and make repairs as needed to restore port hull bilge system to full operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2020
Resolution: Witness the correct operation of the bilge system.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 January 2019 Resolved
A fire drill must be conducted at least once each month. Vessels most recent fire drill was conducted in July 2018.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 January 2019
Resolution: Conducted satisfactory fire drill.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 4 January 2019 Resolved
Crew must be trained on procedures listed in the station bill at least once every three months. Vessels most recent man overboard drill was conducted in July 2018.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 January 2019
Resolution: Vessel conducted a satisfactory man overboard drill.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 January 2019 Resolved
The COI must be posted under glass, such that all pages are visible, in a conspicuous place where observation by passengers is likely. COI is currently posted in the wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2019
Resolved 16 January 2019
Resolution: COI posted on 2nd deck window facing towards passenger area.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 January 2019 Resolved
A fire control plan must be posted on the vessel visible to passengers. Vessel does not have a plan.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2019
Resolved 16 January 2019
Resolution: Posted fire control plan with all the required information on the 1st deck across from the concession stand.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 January 2019 Resolved
Suitable means for shutting off the passage of air through the ventilation in the event of fire. Port aft manual roll down damper does not fully block air flow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2019
Resolved 16 January 2019
Resolution: Fixed gap in the bottom of the aft port fire damper.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 October 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Engineering › Steering Gear System › Ram
Issued 26 June 2017 Resolved
STBD side steering ram was ripped off its mount on a transverse web frame. Crop and renew web frame and prove proper operation of steering system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 28 June 2017
Resolution: Web frame was renewed, steering ram now mounted to a doubler on the web frame and satisfactory underway sea trial was conducted.
Construction/Loadline › Structures › Door
Issued 2 June 2017 Resolved
Converted work list item 07 into CG-835; make port and stbd main deck doors weathertight. 46 CFR 116.1160
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 21 June 2017
Resolution: Both main deck doors had weather stripping installed and made weather-tight.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 June 2017 Resolved
Make the stbd steering compartment available for internal structural examination. Clean all hull plating and framing to bare aluminum.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 8 January 2018
Resolution: The STBD steering gear compartment was thoroughly cleaned and made available for internal structural exam.
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2017 Resolved
Crop and renew hull plating IWO temp repairs in #1 void port and stbd hulls, #3 void port hull, #3 void stbd hull, and fuel void stbd hull. See signed 835 in activity documents.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 22 January 2018
Resolution: All hull plating was cropped and renewed with new plating. The pitting in the #1 voids will be monitored, special note entered.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 29 March 2017 Resolved
Sewage tank has severe pitting. Repair/replace tank during next drydock.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 2 June 2017
Resolution: Vessel rep coated sewage tank in epoxy and repaired all leaks.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 9 December 2016 Resolved
One of the vessel's 50-person IBAs has been removed for annual servicing. The total number of persons allowed on board during cold water operations more than three nautical miles from shore is limited to 150 until the IBA has been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 2 March 2017
Resolution: Verified proper reinatallation of serviced IBA.

Casualty record · 9

19 June 2004Routine · role: Involved in a Marine Casualty · activity 2107811
16 July 2004Routine · role: Involved in a Marine Casualty · activity 2135559
1 November 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4180818
26 February 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5827142
26 June 2017Routine · role: Involved in a Marine Casualty · activity 6189661
30 August 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6256733
23 September 2022Routine · role: Involved in a Marine Casualty · activity 7565414
1 September 2023Routine · role: Involved in a Marine Casualty · activity 7786421
5 June 2024Routine · role: Involved in a Marine Casualty · activity 7929346
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

YANKEE FREEDOM II (2004–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.