This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
2246 - Convention (Subpart B), Gross Ton
673 - Convention (Subpart B), Net Ton
Maury page id
psix-48677
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Make permanent repairs to bottom shell and internal structural members in the starboard bowrake to the satisfaction of the attending marine inspector. Temporary repairs shall be monitored and any changes reported immediately to OCMI Western Alaska.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Navigation
Issued 18 January 1996Resolved
DURING INSPECTION STB NAVIGATION LIGHT FAILED TO OPERATE. PRIOR TO VSL BEING PLACED IN SERVICE PROVE OPERATION OF NAVIGATION LIGHTS.
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Construction/Loadline
Issued 27 February 1990Resolved
PROVIDE ADEQUATE STERN MARKINGS.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Navigation
Issued 27 February 1990Resolved
REPAIR STBD. RUNNING LIGHT. INSTALL STERN LIGHT. PROVE SATISFACTORY OPERATION OF ALL NAV LIGHTS.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Construction/Loadline
Issued 20 July 1988Resolved
MAKE THE FOLLOWING REPAIRS: V&W #4B STIFFENER, 2' OUTBOARD OF #6 DEEP LONG;V&W #4A STIFFENER WHERE IT CONNECTS TO BILGE BRACKET; V&W UNDERDECK LONG #7AT FRAME #1 AFT, AND FRAME #2 FWD.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 25 March 1987Resolved
REPLACE FUEL RETURN HOSE LOCATED BETWEEN PACKAGED GENERATOR VAN AND PORTABLE FUEL TANK WITH COAST GUARD ACCEPTABLE NONMETALLIC HOSE.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Construction/Loadline
Issued 4 March 1987Resolved
MAKE PERMANENT REPAIRS TO #1 STBD RAKE COMPARTMENT BOTTOM SHELL PLATING IN WAY OF SECOND TRANSVERSE DEEP WEB FRAME FROM AFTER BULKHEAD, FOURTH LONGITUDINAL FRAME FROM INBOARD BULKHEAD.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 4 March 1987Resolved
MAKE PERMANENT REPAIRS TO MAIN DECK IN WAY OF PAD EYE LOCATD 20 FEET AFT OF#3 CENTER COMPARTMENT ACCESS PLATE AND 40 FEET FROM PORT SIDE SHELL.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987Resolved
LEAD OR FIBERGLASS LINE STERN LIGHT BATTERY BOX.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 4 March 1987Resolved
MAKE ALL RAKE AND INTERNAL SPACES READY FOR INSPECTION.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Accommodation/Occupational Safety
Issued 4 March 1987Resolved
ADD ADDITIONAL RAIL POSTS AND WIRE ROPE COURSES TO RAILING AS NECESSARY.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 26 February 1986Resolved
PROVIDE MEANS OF SOUNDING ALL COMPARTMENTS.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986