Inspection record

Last inspected 29 October 2024
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1995–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7730525
WBN7617
105628
Flag
UNITED STATES
Maury page id
psix-105628

Documentation record

Registered dimensions (L × B × D)106.3 ft × 34.3 ft × 10.0 ft
Registered tonnagegross 193 / net 81
ITC dimensions (L × B × D)104.8 ft × 34.0 ft × 14.4 ft
ITC tonnagegross 341 / net 102
BuilderTACOMA, WA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
193 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
81 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 26 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 8 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 26

29 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8038042
1 July 2024 Drydock Extension · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7941406
17 April 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7897680
29 September 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7802819
11 July 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7503362
8 June 2021 Initial Certification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7234122
15 February 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7141319
1 January 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6881390
18 November 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6054592
9 February 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5812331
18 September 2015 Marine Casualty Follow Up
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5727698
16 September 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4985864
16 November 2012 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4488530
19 October 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4467982
1 August 2012 Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4398257
10 May 2012 Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4307533
14 April 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2914541
7 March 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2890566
20 June 2006 Uninspected Other · MTSA Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2687348
15 June 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2225740
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2015612
16 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 61074
5 July 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 45507
18 June 1996 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 151192
15 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 73544
1 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 33088

Deficiency record · 16

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 July 2024 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section;A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants. Port side fire hydrant piping near fire plug has a hole in piping. 46CFR142.325(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2024
Resolved 3 July 2024
Resolution: Tested new piping at port side fire hydrant, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2024 Resolved
The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Heat detector in engine room port side behind main engine is missing. 46CFR142.333(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 3 July 2024
Resolution: New heat detector installed and tested in engine room.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 September 2023 Resolved
On the 01 deck both vents for the storage spaces below had hinges that did not allow the ventelation to be closed in the event of a fire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: Vessel confirmed new hinges have been welded in to allow for closure of ventelation and provided pictures
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 29 September 2023 Resolved
Engineer was unable to provide procedures for testing engine and generator alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: outside contractor test all of the set points IAW MFR recommendations. Each panel has the documents certified by a PE/ NICET as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2023 Resolved
Vessel has 2 generators and needs a interlock bar that prevents both generators from coming online at the same time.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: The vessel is equipped with a Load Sharing Panel . The interlock is built into the panel making it impossible to back feed the gensets. They will parallel as designed.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 July 2022 Resolved
Batteries for vessel radar are corroded and leaking liquid. Batteries need to be made safe for operation. 46CFR143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Installed new battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2022 Resolved
Vessel bilge pumps were not demonstrating suction, bilge suction needs to be verified. 46CFR143.275
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Demonstrated bilge suction
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022 Resolved
Excessive oil is present in the engine room bilge, bilge is required to be free from excessive combustible and flammable liquids. 46CFR142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Pumped out excess oil
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 July 2022 Resolved
Engine room aft emergency escape water tight door needs to be made water tight. 46CFR144.330
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: resealed WTD
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 July 2022 Resolved
Navigation assessment is required to be conducted prior to getting underway and the entry needs to be logged. 46CFR140.635
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 30 August 2022
Resolution: Nav assesment updated
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 July 2022 Resolved
Emergency exits for the engine room found to have obstructions and not readily accessible for an emergency escape. Emergency escapes need to be clear from obstruction.46CFR144.500
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 26 July 2022
Resolution: area cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022 Resolved
Multiple dead end wires in both engine room and pilot house. Wires need to terminate at junction box or wires need to be removed from vessel. 46CFR143.575(a)(4)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 30 August 2022
Resolution: Def rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022 Resolved
There are stores present that are blocking the fixed fire fighting local activation station. Area in front of activation station needs to be made clear. 46CFR142.240
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 26 July 2022
Resolution: area made clear
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 June 2021 Resolved
CLOSURE DEVICES MUST BE PROVIDED FOR DECKHOUSE OR HULL PENETRATIONS, WHICH OPEN TO THE EXTERIOR OF THE VESSEL AND WHICH MAY ALLOW WATER TO ENTER VESSEL. INSPECTOR FOUND GAPS AROUND PORT SIDE WATERTIGHT DOOR WHEN DOGS WERE CLOSED. VESSEL TO ADJUST DOOR TO ENSURE WATERTIGHT INTEGRITY. Cite: 46CFR144.320
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: WTD made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 June 2021 Resolved
THERE MUST BE AN INSTALLED OR PORTABLE BILGE PUMP FOR EMERGENCY DEWATERING. INSPECTOR UNABLE TO TEST BILGE PUMP OPERATION DURING INSPECTION. VESSEL TO PROVIDE MEANS OF TESTING. Cite: 46CFR143.275
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: Bilge pump test succesful.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 30 June 2021 Resolved
FOR VESSELS OTHER THAN THOSE COVERED IN PARA. (B) AND (C) OF THIS SECTION, THE NAME OF THE VESSEL MUST BE MARKED ON SOME CLEARLY VISIBLE EXTERIOR PART OF THE PORT AND STARBOARD BOW AND STERN OF THE VESSEL. VESSEL DID NOT HAVE NAME MARKED ON STERN OF VESSEL. VESSEL TO MARK NAME ON STERN OF VESSEL. Cite: 46CFR67.123
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: Vessel name placed on stern of vessel.

Recorded names · 1

SIOUX (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.