Records from 1995 to 2024. Most recent: inspection, 29 October 2024.
Documentation record
Registered dimensions (L × B × D)106.3 ft × 34.3 ft × 10.0 ft
Registered tonnagegross 193 / net 81
ITC dimensions (L × B × D)104.8 ft × 34.0 ft × 14.4 ft
ITC tonnagegross 341 / net 102
Builderbuilder not recorded · TACOMA, WA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
193 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
81 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
29 October 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8038042
1 July 2024
Drydock Extension · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7941406
17 April 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7897680
29 September 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7802819
11 July 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7503362
8 June 2021
Initial Certification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7234122
15 February 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7141319
1 January 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6881390
18 November 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6054592
9 February 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5812331
18 September 2015
Marine Casualty Follow Up
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5727698
16 September 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4985864
16 November 2012
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4488530
19 October 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4467982
1 August 2012
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4398257
10 May 2012
Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4307533
14 April 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2914541
7 March 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2890566
20 June 2006
Uninspected Other · MTSA Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2687348
15 June 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2225740
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2015612
16 July 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 61074
5 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 45507
18 June 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 151192
15 December 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 73544
1 January 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 33088
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 July 2024
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section;A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants. Port side fire hydrant piping near fire plug has a hole in piping.
46CFR142.325(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2024
Resolved 3 July 2024
Resolution: Tested new piping at port side fire hydrant, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2024
Resolved
The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Heat detector in engine room port side behind main engine is missing.
46CFR142.333(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 3 July 2024
Resolution: New heat detector installed and tested in engine room.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 September 2023
Resolved
On the 01 deck both vents for the storage spaces below had hinges that did not allow the ventelation to be closed in the event of a fire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: Vessel confirmed new hinges have been welded in to allow for closure of ventelation and provided pictures
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 29 September 2023
Resolved
Engineer was unable to provide procedures for testing engine and generator alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: outside contractor test all of the set points IAW MFR recommendations. Each panel has the documents certified by a PE/ NICET as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2023
Resolved
Vessel has 2 generators and needs a interlock bar that prevents both generators from coming online at the same time.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2023
Resolved 14 November 2023
Resolution: The vessel is equipped with a Load Sharing Panel . The interlock is built into the panel making it impossible to back feed the gensets. They will parallel as designed.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 July 2022
Resolved
Batteries for vessel radar are corroded and leaking liquid. Batteries need to be made safe for operation. 46CFR143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Installed new battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2022
Resolved
Vessel bilge pumps were not demonstrating suction, bilge suction needs to be verified. 46CFR143.275
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Demonstrated bilge suction
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022
Resolved
Excessive oil is present in the engine room bilge, bilge is required to be free from excessive combustible and flammable liquids. 46CFR142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2022
Resolved 26 July 2022
Resolution: Pumped out excess oil
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 July 2022
Resolved
Engine room aft emergency escape water tight door needs to be made water tight. 46CFR144.330
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2022
Resolution: resealed WTD
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 July 2022
Resolved
Navigation assessment is required to be conducted prior to getting underway and the entry needs to be logged. 46CFR140.635
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 30 August 2022
Resolution: Nav assesment updated
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 July 2022
Resolved
Emergency exits for the engine room found to have obstructions and not readily accessible for an emergency escape. Emergency escapes need to be clear from obstruction.46CFR144.500
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 26 July 2022
Resolution: area cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022
Resolved
Multiple dead end wires in both engine room and pilot house. Wires need to terminate at junction box or wires need to be removed from vessel. 46CFR143.575(a)(4)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 30 August 2022
Resolution: Def rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022
Resolved
There are stores present that are blocking the fixed fire fighting local activation station. Area in front of activation station needs to be made clear. 46CFR142.240
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 26 July 2022
Resolution: area made clear
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 June 2021
Resolved
CLOSURE DEVICES MUST BE PROVIDED FOR DECKHOUSE OR HULL PENETRATIONS, WHICH OPEN TO THE EXTERIOR OF THE VESSEL AND WHICH MAY ALLOW WATER TO ENTER VESSEL.
INSPECTOR FOUND GAPS AROUND PORT SIDE WATERTIGHT DOOR WHEN DOGS WERE CLOSED.
VESSEL TO ADJUST DOOR TO ENSURE WATERTIGHT INTEGRITY.
Cite: 46CFR144.320
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: WTD made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 June 2021
Resolved
THERE MUST BE AN INSTALLED OR PORTABLE BILGE PUMP FOR EMERGENCY DEWATERING.
INSPECTOR UNABLE TO TEST BILGE PUMP OPERATION DURING INSPECTION. VESSEL TO PROVIDE MEANS OF TESTING.
Cite: 46CFR143.275
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: Bilge pump test succesful.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 30 June 2021
Resolved
FOR VESSELS OTHER THAN THOSE COVERED IN PARA. (B) AND (C) OF THIS SECTION, THE NAME OF THE VESSEL MUST BE MARKED ON SOME CLEARLY VISIBLE EXTERIOR PART OF THE PORT AND STARBOARD BOW AND STERN OF THE VESSEL.
VESSEL DID NOT HAVE NAME MARKED ON STERN OF VESSEL.
VESSEL TO MARK NAME ON STERN OF VESSEL.
Cite: 46CFR67.123
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 July 2021
Resolution: Vessel name placed on stern of vessel.