MAURY USCG vessel records
← All vessels

SCOUT

SCOUT is a 1976 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in February 2022, along with 9 deficiencies and 2 casualty investigations between 2006 and 2011.

Records from 2006 to 2022. Most recent: inspection, 16 February 2022.

Built
1976
Last inspected
16 February 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 February 2022
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB4751
Flag
UNITED STATES
Maury page id
psix-48725

Documentation record

Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

16 February 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397585
25 January 2022 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7385670
6 January 2021 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7118669
6 February 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904052
16 December 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6876430
21 March 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6646616
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539397
14 June 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6444006
6 December 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6319859
2 February 2017 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6081521
5 January 2016 DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5791703

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 January 2021 Resolved
Fuel supply flexible hose shall be visible, easily accessible and shall not penetrate watertight bulkheads. MI obersrved hose through water tight bulkhead. 46CFR 182.20(2)(i) (Old T)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2021
Resolved 19 January 2021
Resolution: Replaced rubber fuel ine through the bulkhead with metalic material. IAW Reg.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2021 Resolved
All vessels shall be provided with a satisfactory arrangements for drainage. MI observed bilge pump in lazarrette space not operable, crew was able to fix prior to departure. 46 CFR 182.25-1(a)(Old T)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 January 2021
Resolved 6 January 2021
Resolution: Crew was able to fix bilge pump prior to departure. Tested space to ensure bilge system worked by expelling water from lazarrette space
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 January 2021 Resolved
On a vessel of at least 26 feet, visual and audible alarm must be provided at operators station indicating high water level. MI observed lazarrette high water alarm not operating. Crew was able to fix prior to MI departure.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 6 January 2021
Resolved 6 January 2021
Resolution: Crew repaired electrical sensor on bilge alarm in lazarrette space. Alarm works at operators station for high wate level.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 March 2019 Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Pitting found at stbd quarter, both inner and outer surfaces. Pitting is located just below deck and well above the waterline. To be corrected at next dry dock. 46 CFR 177.100
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 16 December 2019
Resolution: Attended vessel on 12/16/2019 for dry dock, vessel showed new plating/repairs on stbd quarter where damage was mentioned. Cleared deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 January 2021
Resolution: Vessel AIS was update with Vessel Information and displayed correctly.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 15 June 2018 Resolved
Radiotelephony certificate expired. 46 CFR 80.901
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 19 June 2018
Resolution: Vessel rep provided copy of new FCC Cert.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 15 June 2018 Resolved
Missing vapor tight boundaries on 02 wire runs on the forward/Port bulkhead of the engine room. 46 CFR 182.35-1(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 19 June 2018
Resolution: Vessel rep provided iamges of each bulkhead penetration filled with appropriate fire stop.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 June 2018 Resolved
Lifeline not tied around the body of the the ring buoy. 46 CFR 180.70(d)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 June 2018
Resolved 15 June 2018
Resolution: Deckhand corrected line during inspection
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 June 2018 Resolved
Children lifejacket stowage not marked by a placard/sign 46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 June 2018
Resolved 15 June 2018
Resolution: Crew installed proper sign.

Casualty record · 2

20 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2586453
22 July 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4109654
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.