Records from 2009 to 2025. Most recent: inspection, 1 July 2025.
Documentation record
Registered dimensions (L × B × D)173.0 ft × 44.0 ft × 16.0 ft
Registered tonnagegross 1,004 / net 301
ITC dimensions (L × B × D)173.0 ft × 44.0 ft × 16.0 ft
ITC tonnagegross 1,004 / net 301
BuilderEASTERN SHIPBUILDING · PANAMA CITY, FL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it301 - Convention (Subpart B), Net Ton
1004 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
1 July 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8172970
1 July 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7946777
27 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7944539
24 April 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7896441
1 April 2024
Drydock Exam · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7887931
9 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7763816
22 July 2022
Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7513611
26 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7438729
28 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7420079
10 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7282254
1 December 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7105147
6 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6998341
6 May 2019
Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · Administrative Inspection · MTSA Verification · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6678153
1 August 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6498129
31 July 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6498800
30 January 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6346384
17 May 2017
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6150378
12 April 2017
Drydock Exam · Administrative Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6123052
10 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102576
3 February 2016
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5808585
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 April 2024
Resolved
Procedures for tests to be conducted on automated equipment by the operator and the CG must be submitted to comply with 127.110 of this subchapter; SSDG overspeed alarm and procedures were not operating as intended. Conduct repairs prior to going underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2024
Resolution: Changed out 24V governor motor & reset governor.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 April 2024
Resolved
Vsl of 100 or more GT or 65 ft or more must have navigational lighting in compliance with the applicable navigation rules; Navigational light panel was not operating as intended. Conduct repair prior to going underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2024
Resolution: Nav panel fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2024
Resolved
Each ring life buoy must be marked with Type I or II retro-reflective material approved under subpart 164.018; 3 ring buoys had insufficient tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 25 April 2024
Resolution: Tape replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2024
Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members and vessel from electrical hazards, including fire. Cables were improperly supported.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 May 2024
Resolution: Cables supported with metal straps
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2024
Resolved
Ensure vessel is equipped with a master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key.
46 U.S. Code 3106
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 3 May 2024
Resolution: Master key log began.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2024
Resolved
Loadline survey shall consist of review of the listed items: the following discrepancies were noted: 1) worn out chain links, 2) exhaust housing was wasted on fly bridge, and 3) watertight doors throughout vessel were not self closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 1 May 2024
Resolution: ABS oversaw rectification of LL related issues.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 9 August 2023
Resolved
Each vessel muct be fitted with a general alarm IAW §113.25. Found general alarm inoperable. Repair / replace.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2023
Resolution: Replaced battery charger and proved proper operation of general alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 August 2023
Resolved
Each generator prime mover must have overspeed device independent of normal operating governer NTE max rated speed by 15%. Unable to prove operation of overspeed protection device on #1/#2 generators. Prove proper operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2023
Resolution: Provided tech report showing proper operation and testing of overspeed devices.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2021
Resolved
Life rings must be in proper condition. Port and Starboard bridge and portside main deck liferings were waterlogged. Replace liferings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2021
Resolved 12 August 2021
Resolution: Life rings were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2021
Resolved
All extinguishers must be hydro tested. Paint locker extinguisher expired and not tested. Repair or get tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2021
Resolved 12 August 2021
Resolution: AFFF ext has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 August 2021
Resolved
Survival craft must be stowed in a way that does not interfere w/ embarkation. Hydrostatic release was stowed incorrectly. Fixed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 August 2021
Resolved 10 August 2021
Resolution: cleared on spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2021
Resolved
Battery must be resistant to damage by electrolytes. Battery box has liquid and debris in bottom. Clean battery box.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 August 2021
Resolved 10 August 2021
Resolution: cleared on spot
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 August 2021
Resolved
Circuits supplying power lights to embarkation lights must be operable. Lights were inop. Fix or replace lights.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 August 2021
Resolved 10 August 2021
Resolution: cleared on spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2021
Resolved
Electrical equipment on vsl must be designated to provide services for safety under normal conditions. Bilge Motor INOP. Fix bilge pump motor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: soft start was fixed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2021
Resolved
Vsl shall be free of all fire hazardous. Build up fuel in bilge manifold. Clean bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: oily water was pumped out.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 May 2019
Resolved
An oceangoing ship of 400 GT and up but less than 10,000 GT must be fitted with approved 15 ppm oily-water separating (OWS) equipment for processing oily mixtures from bilges or fuel oil tank ballast. Vessel's OWS requires a replacement pump and motor and is inoperable. Vessel shall retain on board all oily water for discharge to a facility only and shall not discharge overboard (in accordance with 33 CFR 151.10) until the OWS is rendered operable, to the satisfaction of the marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 29 May 2019
Resolution: OWS issue was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2019
Resolved
Fire Pump is not Opertional
46CFR132.120
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2019
Resolved 23 May 2019
Resolution: Fire pump was repaired. CGMI witnessed satisfactory operation.
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2017
Resolved
46 CFR 129.320 Aft generator rated at 40 degree celsius ambient temperature, should be rated at 50 degrees delsius.
Due 16 June 2017
Resolved 5 July 2017
Resolution: Replace with proper Data plate
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 May 2017
Resolved
46 CFR 129.440 Stencil all e-lights.
Due 17 June 2017
Resolved 5 July 2017
Resolution: Verified stenciling on e-lghts.
Lifesaving › Inflatable Liferafts › Servicing
Issued 3 February 2016
Resolved
Life Raft not serviced within specified time.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2017
Resolution: Installation & servicing of liferafts verified by marine inspector.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 3 February 2016
Resolved
Approved SOPEP not on board.
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 10 March 2017
Resolution: Vessel rep provided SOPEP approval letter from CGHQ.