MELINDA B. ADAMS

MELINDA B. ADAMS is a 1976 offshore supply vessel. The Coast Guard has recorded 80 inspections since 1982, most recently in August 2026, along with 59 deficiencies and 2 casualty investigations in 2023.

Records from 1982 to 2026. Most recent: inspection, 5 August 2026.

Built
1976
Last inspected
5 August 2026
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7644324 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ2666
Flag
UNITED STATES
367300160
Maury page id
psix-48828

Inspections, by type

…with no type recorded18
Years with a record 36 calendar years (1982–2026)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)157.6 ft × 36.0 ft × 12.2 ft
Registered tonnagegross 189 / net 129
ITC dimensions (L × B × D)157.6 ft × 36.0 ft × 12.2 ft
ITC tonnagegross 520 / net 156
BuilderBOLLINGER SHIPYARD · LOCKPORT, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCUT OFF, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it189 - Regulatory (Subpart C or D), Gross Ton
520 - Convention (Subpart B), Gross Ton
129 - Regulatory (Subpart C or D), Net Ton
156 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ2666MMSI 367300160 · active · compulsorily equipped · granted 26 February 2019, expires 13 May 2029
WBA4701MMSI not assigned · expired · compulsorily equipped · granted 24 June 1996, cancelled 25 November 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DUPLICATE OF CAPT LIAM Commercial Fishing Vessel · MISLE 1723054 · 18 November 2023 · activity 7868616MISS ANGELA Passenger (Inspected) · MISLE 51860 · 31 July 2000 · activity 35414IB9518 Tank Barge · MISLE 47728 · 17 July 2000 · activity 21256KRISTIN ALEXIS Towing Vessel · MISLE 161994 · 17 July 2000 · activity 21256

Inspection history · 80

5 August 2026 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8455890
23 July 2026 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8444928
4 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8319714
3 February 2026 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8305547
31 March 2025 Deficiency Check · MARPOL Annex VI Survey · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8102774
11 April 2024 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7893604
5 February 2024 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7860522
27 December 2023 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7842872
18 November 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7826768
18 November 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7868616
26 July 2023 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7753166
20 July 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7747950
18 July 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7775520
10 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7685061
3 May 2023 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7680498
3 May 2023 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7794660
24 April 2023 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7674395
9 April 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7675404
9 April 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7696235
8 April 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7672981
27 April 2022 MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7433761
17 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7199585
5 March 2021 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7150638
3 February 2021 Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7135042
24 April 2020 MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6943250
30 March 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6932993
21 March 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6646505
15 March 2019 Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6932945
22 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6630506
18 July 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6483592
28 June 2018 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6458101
26 June 2018 Periodic Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6456973
7 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168719
5 April 2016 MARPOL Annex VI Survey · Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847811
11 March 2016 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5831237
19 May 2014 MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4860232
15 November 2010 Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3890082
22 July 2009 Cargo Tank Internal · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3547652
14 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3533529
14 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3192202
26 June 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2976844
8 June 2006 Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2673638
16 May 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2359382
27 April 2005 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2347249
24 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2109223
18 May 2004 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2071102
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978074
6 September 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1900131
4 August 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1866315
22 July 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1649041
18 July 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074255
10 July 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 43549
19 June 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412308
6 September 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821956
31 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35414
17 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 21256
17 July 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819964
17 May 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395447
12 May 1999 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406505
24 June 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130157
22 May 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394967
17 October 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762787
23 September 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 200143
20 March 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371713
13 May 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459227
27 April 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357242
18 November 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180452
28 April 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409125
26 April 1994 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425454
24 January 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953369
24 January 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268593
23 October 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247872
17 October 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253982
29 August 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248341
12 August 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936943
7 June 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321655
8 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989177
7 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283484
20 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963791
25 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968015

Deficiency record · 59

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 5 May 2025 Resolved
On U.S. inspected ships, oily water seperating equipment and bilge alarms must be approved under 46 CFR 162.050 Marine Inspector found the on-board OWS system did not have a Oil Content Meter as required by approval.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 13 November 2025
Resolution: Vessel has stated they will not be seeking an IOPP and therefore do not need to have the correct OCM installed to comply with international regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2023 Resolved
All piping systems shall be examined under working conditions as required by the marine inspector. The potable water port to starboard crossover pipe was holed and temp repaired with rubber material and three hose clamps. Make permanent repairs to the satisfaction of attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 10 May 2023
Resolution: received objective evidence that the pipe was permanently repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 3 May 2023 Resolved
Structures that are located on or above the line of the uppermost complete deck that are under cover (sheltered), but open to the weather are exempt from tonnage as open space. The following additional requirements apply: -an interior or exterion opening that is temporarily closed by cover plates or boards held in place only by hook bolts is considered open to the weather, if hook bolts used to secure cover plates or boards are spaced at least one foot apart and hook over stiffener installed around the perimeter of the opening; if the cover plates or board fit tightly against the weather side of the bulkhead and; if battening, caulking or gaskets of any material are not used. The tonnage opening leading into the accommodation spaces is missing two hook bolts and the cover plating is caulked around all sides. Remove all caulking material and at next drydock (2024) make all tonnage openings available for further inspection by attending CG marine inspector to ensure all hook bolts are in sufficient condition and in place.
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 21 February 2024
Resolution: All chaulking removed and J-hooks renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 24 April 2023 Resolved
EPIRB stowed in a manner so that it will float free if the vessel sinks. EPIRB was stowed in go to bag in the skin of the ship due to outside bracket failure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2023
Resolved 24 April 2023
Resolution: The vessel rep purchased and registered a new EPIRB and had it installed on site. Photos in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 April 2023 Resolved
Gskets shall be made of materials which are not injuriously affected by the fluid or by temperature. Fuel oil #2 pump gasket failed and leaking
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 24 April 2023
Resolved 28 April 2023
Resolution: Gasket Replaced, photos in documents
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 April 2023 Resolved
Lighting for stairways, passageways and escapeways in machinery spaces and work spaces adequate to permit passangers and crew readily to find their wasy to open decks and to lifeboat embarkation and assembly points with all watertight doors and fire screen doors closed. Emergency lighting was insufficient on STBD side of engine room.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 10 May 2023
Resolution: Received photos of elights installed. Some are 4 ft emergency ballast light and others are LED battle lantern style.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023 Resolved
Non-metallic flexible hoses must meet SAE J1942. Non metallic flexible hose was damaged and ineffective.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 28 April 2023
Resolution: Hose replaced, photos in documents
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 March 2021 Resolved
essel shall maintain an EPRIB IAW 47 CFR Subpart 80. Vessel had the incorrect MMSI number registered. 46 CFR 94.60-1 (Old I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Vessel updated EPIRB information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 March 2021 Resolved
Vessel shall have Safety Relief Valves serviced twice in five years, not to exceed three years. Vessel had the Safety Relief Valves serviced in DEC 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Vessel had 3rd party report stating that the pressure relief valves were serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 5 March 2021 Resolved
Vessel shall have four service lines for each shoulder gun line-throwing appliance. Vessel only had three service lines available. 46 CFR 94.45-15(b)(3) (Old I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Vessel purchased another linethrowing line.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
Vessel shall maintain matt black screens for navigation lights. The port side screen had an area that was wasted and had white primer around the wasted section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 28 April 2021
Resolution: Temp repairs compelted to navigation screen.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Life Preservers must have a personal flotation device light IAW 46CFR161.012. Vessel had two non-operational lights attached to personal floatation devices in the spare lightjacket locker. 46 CFR 94.42-1 (Old I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Vessel purchased another linethrowing line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2021 Resolved
Vessel shall ensure that the ground detection for the ship's service power system is operational. Vessel's ground detection was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Third party replaced the gauge and bulbs on the switchboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 March 2021 Resolved
Fire detection shall be operational. Vessel's kitchen smoke dectector was not operational with the cover and battery removed. 46 CFR 95.05-1 (Old I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Vessel reinstalled the smoke detector battery and cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 March 2021 Resolved
Vessel shall ensure the gauges are operational for the main or auxiliary engines. Vessel's starboard generator's jacket water temperature was not working.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 March 2021
Resolution: Third party replaced jacket water temp guage on the stbd generator & verified operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2020 Resolved
FLEXIBLE HOSE ON STEERING GEAR UNSERVICEABLE; CREW REPLACED WITH SAEJ 1942 APPROVED TYPE HOSE. 46 CFR 56.60-25(b)
Action required: 10 - Deficiency Rectified
Due 24 April 2020
Resolved 24 April 2020
Resolution: HOSE REPLACED
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 April 2020 Resolved
CORRIDOR LEADING TO ENGINE ROOM HAD CABLE PENETRATIONS WITHOUT ANY FIRE INSULATION; CREW FILLED IN GAPS WITH APPROVED FIRE STOP PENETRATION SEAL AS PER 46 CFR 92.07-5(f). 46 CFR 92.05-1
Action required: 10 - Deficiency Rectified
Due 24 April 2020
Resolved 24 April 2020
Resolution: CABLE PENETRATIONS APPROPRIATELY SEALED.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 March 2019 Resolved
LIFEBUOY LIGHT BATTERY FOUND EXPIRED.46CFR90.27-1 TO 46CFR199.70(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 25 March 2019
Resolution: Received verification of correction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2019 Resolved
VESSEL HAD OUT OF DATE NAUTICAL PUBLICATIONS. 46CFR97.05-5
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 25 March 2019
Resolution: Received verification of correction.
Engineering › Fuel Oil Service System › Filter
Issued 5 April 2016 Resolved
Fuel filters with metallic cocks did not have plugs for filter drains.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Vessel provided plugs for fuel filters.
Engineering › Fuel Oil Service System › Hose
Issued 5 April 2016 Resolved
Port side main propulsion engine fuel hose feed to low pressure pump chaffed, unserviceable.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Vessel opted to renew line, completed renewal prior to completion of inspection.
Communications › Internal Communications System › Sound-powered Telephone
Issued 5 April 2016 Resolved
Engineer call light covered in paint, not visible.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Vessel removed paint from light fixture, light now visible.
Stability › Watertight Integrity › General
Issued 5 April 2016 Resolved
Hinged watertight door aft of engine room to rudder room gasket not properly installed.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Vessel properly installed gasket.
Engineering › Fuel Oil Service System › Valve
Issued 5 April 2016 Resolved
Provide serviceable flange for port fuel isolation valve IAW 46CFR56.50-60(d)(1) by 12APR16.
Due 12 April 2016
Resolved 7 April 2016
Resolution: Vessel provided evidence of correction to item; flange renewed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2016 Resolved
Provide machinery guard to port air compressor IAW46CFR92.25 by 12APR16
Due 12 April 2016
Resolved 7 April 2016
Resolution: Vessel provided evidence of installation of machinery guard.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 14 April 2008 Resolved
Repair stbd eng shutdown at operating station.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 25 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 April 2008 Resolved
Gouge and weld cracked welds along bulkhead in rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Communications › Audible Communications › Bell
Issued 14 April 2008 Resolved
Provide new ship's bell, old bell had 2 cracks over 3 inches.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 25 April 2008
Documentation › Certificates/Documents
Issued 4 August 2003 Resolved
PROVIDE BRIDGE-TO-BRIDGE FCC LICENSE. LEGACY COMPONENT DESC: BRIDGE TO BRIDGE FCC
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 5 August 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 August 2003 Resolved
PROVIDE CURRENT COPY OF CG LIGHT LIST.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2003
Resolved 5 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 August 2003 Resolved
REPAIR STARBOARD MAIN ENGINE EMERGENCY STOP. LEGACY COMPONENT DESC: EMERGENCY STOP
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2003
Resolved 5 August 2003
Electrical › Electrical Distribution System (service)
Issued 4 August 2003 Resolved
PROVIDE NON-METALLIC GRAB BAR ON MAIN SWITCHBOARD. LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 5 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 4 August 2003 Resolved
PROVIDE HANDLE FOR FUEL SUPPLY VALVE ON BOW THRUSTER ENGINE. LEGACY COMPONENT DESC: FUEL VALVE
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2003
Resolved 5 August 2003
Communications › Internal Communications System › Sound-powered Telephone
Issued 4 August 2003 Resolved
PROVIDE VISUAL INDICATOR FOR ENGINE ROOM SOUND-POWER PHONE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 5 August 2003
Construction/Loadline › Structures › Door
Issued 4 August 2003 Resolved
REPAIR PORT DECK LOCKER WATER TIGHT DOOR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2003
Resolved 5 August 2003
Construction/Loadline › Structures › Door
Issued 4 August 2003 Resolved
ADJUST DOGS ON STARBOARD WATER TIGHT DOOR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2003
Resolved 5 August 2003
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 July 2002 Resolved
COAST PILOT PUBLICATION OUT OF DATE.
Due 22 August 2002
Resolved 22 July 2002
Documentation › Markings/Placards
Issued 22 July 2002 Resolved
LIFERAFT LAUNCHING STATION MARKINGS UNREADABLE. LEGACY COMPONENT DESC: LIFERAFT STATIONS
Due 22 August 2002
Resolved 22 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
RENEW GLASS WINDOW ON STARBOARD SIDE. LEGACY COMPONENT DESC: GLASS WINDOW
Due 22 August 2002
Resolved 22 July 2002
Accommodation/Occupational Safety › Potable Water System
Issued 22 July 2002 Resolved
RENEW RELIEF VALVE ON HOT WATER HEATER. LEGACY COMPONENT DESC: HOT WATER HEATER
Due 22 August 2002
Resolved 22 July 2002
Engineering › Fuel Oil Service System › Filter
Issued 22 July 2002 Resolved
RACOR FILTER UNITS DO NOT HAVE METALLIC PLUGS.
Due 22 August 2002
Resolved 22 July 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 22 July 2002 Resolved
LUBE OIL TANK IN ENGINERROM NOT SUPPLIED WITH FLAME SCREEN.
Due 22 August 2002
Resolved 22 July 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 July 2002 Resolved
RUDDEROOM AND HALLWAY BILGE ALARMS WIRED TOGETHER ON THE SAME AUDIBLE ALARM.
Action required: 705 - Other - as specified
Due 22 August 2002
Resolved 29 July 2002
Construction/Loadline
Issued 18 July 2001 Resolved
MAKE PERMENENT REPAIRS TO MAIN DECK IWO ENGINE ROOM AND JUST AFT OF #2 F/O TANK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 July 2001
Resolved 1 October 2001
Construction/Loadline
Issued 17 July 2000 Resolved
MAKE PERMENANT REPAIRS TO SET-IN IN GUNWALE AND TORN DECK AREA IN VICINITY OF STERN WRAP, MAIN DECK. HOLES IN MAIN DECK MAY BE TEMPORAILY REPAIRED. ALL REPAIRS NEED TO BE TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Lifesaving
Issued 22 May 1998 Resolved
PROPERLY INSTALL LIFERAFT MOUNTS TO MEET CURRENT DEPLOYMENT STANDARDS IAW_x001C_ 46CFR199.130(a)(7)(ii).
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Unknown
Issued 22 May 1998 Resolved
INSTALL MAIN DIESEL ENGINE SHUTDOWNS IN PILOTHOUSE.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Unknown
Issued 22 May 1998 Resolved
HARD PIPE MAIN DIESEL FUEL LINES. FLEXIBLE HOSES NOT TO EXCEED 30 INCHES.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Documentation
Issued 28 April 1994 Resolved
PROVIDE ON BOARD CERTIFICATE OF DOCUMENTATION WITH CORRECT OWNER ADDRESS AND TONNAGE .
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 17 October 1991 Resolved
PROVIDE LIGHTSHIP DATA TO MSC WASHINGTON D.C. REFLECTING CHANGES EFFECTED_x001C_BY REMOVAL OF 4 DRY BULK TANKS AND DRY BULK PUMP. VESSEL TO BE OPERATED _x001C_ PER COAST GUARD STABILITY LETTER DTD 20JUL76 AND PROVISIONAL LOADLINE DTD_x001C_ 12AUG91.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Documentation
Issued 17 October 1991 Resolved
PROVIDE NEW DOCUMENT REFLECTING NEW OWNERSHIP.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Documentation
Issued 17 October 1991 Resolved
PROVIDE CAPACITY TABLES FOR ALL TANKS INCLUDING P/S 4 AND 5, INCLUDING_x001C_ SOUNDING TABLES AND NEW TANK DIAGRAMS. ALL TO BE PLACED ON BOARD VESSEL.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Documentation
Issued 12 August 1991 Resolved
PROVIDE CAPACITY TABLES FOR ALL TANKS INCLUDING P & S 4 AND 5. INCLUDING SOUNDING TABLES AND NEW TANK DIAGRAMS. ALL TO BE PLACED ON BOARD VESSEL.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 12 August 1991 Resolved
PROVIDE LIGHTSHIP DATA TO MSC WASHINGTON D.C. REFLECTING CHANGES IN REMOVAL OF 4 DRY BULK TANKS AND DRY BULK PUMP. VESSEL TO BE OPERATED PER COAST GUARD STABILITY LETTER DTD 20JULY76 AND PROVISIONAL LOADLINE DTD _x001C_ 12 AUG 91.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 12 August 1991 Resolved
PROVIDE NEW DOCUMENT REFLECTING NEW OWNERSHIP.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 12 August 1991 Resolved
PROVIDE CRANE SPECIFICATION, LOADCHART AS RIGGED, ANGLE OR RADIUS INDICATORAND PROPER IN LINE RELIEF VALVE AND SYSTEM PRESSURE GAUGES.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 25 May 1982 Resolved
MAKE APPLICATION FOR RE-ADMEASURMENT TO INCLUED AFT CARGO TANKS.
Condition: Unknown
Due 8 September 1982
Resolved 25 May 1982
Documentation
Issued 25 May 1982 Resolved
THE CARRIAGE OF HIGH DENSITY DRILLING FLUIDS IS PROHIBITED UNTIL APPROVAL HAS BEEN GRANTED BY COGNIZANT OCMI.
Condition: Unknown
Due 8 September 1982
Resolved 25 May 1982
Documentation
Issued 25 May 1982 Resolved
SUBMIT STRUCTURAL PLANS FOR AFTER CARGO TANK MODIFICATIONS TO COAST GUARD (MMT) NEW ORLEANS FOR APPROVAL AND THE RE-ISSUE OF VESSEL'S STABILITY LTR.
Condition: Unknown
Due 8 September 1982
Resolved 25 May 1982

Casualty record · 2

3 May 2023Routine · role: Involved in a Marine Casualty · activity 7794660
18 July 2023Routine · role: Involved in a Marine Casualty · activity 7775520
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.