UNCLE SAM 7

UNCLE SAM 7 is a 1976 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1983, most recently in May 2026, along with 66 deficiencies and 3 casualty investigations between 2020 and 2026.

Records from 1983 to 2026. Most recent: inspection, 12 May 2026.

Built
1976
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYF6588
Flag
UNITED STATES
367107260 (licence lapsed)
Maury page id
psix-48833

Inspections, by type

…with no type recorded20
Years with a record 41 calendar years (1983–2026)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 22.0 ft × 7.1 ft
Registered tonnagegross 55 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALEXANDRIA BAY, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYF6588MMSI 367107260 · expired · compulsorily equipped · granted 26 April 2016, cancelled 15 August 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ISLAND DUCHESS Passenger (Inspected) · MISLE 299242 · 20 August 2020 · activity 7041644

Inspection history · 98

12 May 2026 Type not recorded
No type recorded · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8390708
4 May 2026 Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8361256
27 April 2026 Vessel Attendance · COI Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8350264
23 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8257721
6 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8247376
17 September 2025 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8236549
23 June 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8164346
27 March 2025 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8128930
24 February 2025 Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8085210
10 February 2025 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8085781
10 February 2025 Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8088220
24 September 2024 In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8010272
10 June 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7931558
6 December 2023 Plan Review (Other than "T") · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7834500
14 November 2023 Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7885899
3 October 2023 In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7802350
24 July 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7764956
22 May 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7694197
18 May 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7691121
28 October 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7585328
19 May 2022 MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7473613
20 April 2022 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7430062
16 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7582752
29 June 2021 DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7239026
11 May 2021 COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7188365
12 November 2020 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7093337
20 August 2020 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7041644
16 July 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7007981
19 May 2020 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6960774
15 July 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6712616
18 July 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6483677
11 July 2018 In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6474614
20 June 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6181050
22 June 2016 Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916245
3 May 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5867936
13 July 2015 DAPI Audit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5184286
4 June 2014 Administrative Inspection · DAPI Audit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4880948
9 May 2014 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4854467
7 June 2012 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4341234
16 May 2012 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4313371
5 July 2011 Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 4069111
15 July 2009 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3537159
2 March 2009 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3426257
14 August 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3320388
27 June 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2980595
9 May 2006 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2751941
25 April 2006 Hull Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2638853
3 August 2005 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2450561
22 June 2005 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2400078
7 June 2005 MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2383853
10 June 2004 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2095551
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963278
5 June 2003 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1812325
23 April 2002 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1609313
9 May 2001 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1464378
26 April 2001 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1467761
27 March 2001 Drydock Extension
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1062213
15 August 2000 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1405037
9 May 2000 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 819264
29 March 2000 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 816395
31 August 1999 Excursion Permit
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 785213
21 July 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 67378
21 July 1999 Damage Survey
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1103616
10 May 1999 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1400990
30 April 1999 Plan Review "T" Boat
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 795890
11 March 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 809115
14 May 1998 Deficiency Check · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1388490
14 July 1997 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1390560
3 March 1997 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1105367
10 June 1996 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1409505
25 March 1996 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1467464
11 March 1996 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 885059
4 July 1995 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 163003
26 May 1995 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1182377
17 May 1995 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1424068
20 July 1994 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 862404
30 June 1994 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1391997
3 January 1994 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 853825
6 October 1993 Inclining Experiment
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1397965
2 July 1993 Re-Inspection · Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1403581
4 March 1993 Plan Review "T" Boat
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1379750
14 May 1992 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1463005
29 January 1992 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1432601
23 April 1991 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1236142
5 April 1991 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 919644
24 May 1990 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1220964
14 April 1989 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 892669
11 May 1988 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1040190
4 April 1988 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1035951
30 April 1987 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1024169
25 April 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1318104
6 April 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1317091
19 March 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1019461
28 August 1986 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1339380
30 April 1986 Credit Drydock
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1301356
30 April 1986 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1301358
1 May 1985 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 981702
25 April 1983 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1289295

Deficiency record · 66

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2026 Resolved
The vessel is permitted temporary manning allowance and deviate from the manning requirements set forth in the Certificate of Inspection (COI) reducing the manning to: * 01 Master * 01 Deckhand Conditions of Deviation: * Vessel passenger count is reduced to 90 * The upper deck must remain secured at all times. * No passengers are permitted on the second deck under any circumstances during operations, unless an emergency situation dictates. This manning reduction is authorized under the condition that the vessel operates within the limitations specified above. Failure to comply with these conditions may result in the revocation of this authorization. This CG-835V is valid until July 1st, 2026.
Action required: 705 - Other - as specified
Due 1 July 2026
Resolved 16 June 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2025 Resolved
The vessel is permitted temporary manning allowance and deviate from the manning requirements set forth in the Certificate of Inspection (COI) reducing the manning to: * 01 Master * 01 Deckhand Conditions of Deviation: * Vessel passenger count is reduced to 90 * The upper deck must remain secured at all times. * No passengers are permitted on the second deck under any circumstances during operations, unless an emergency situation dictates. This manning reduction is authorized under the condition that the vessel operates within the limitations specified above. Failure to comply with these conditions may result in the revocation of this authorization. This CG-835V is valid until October 14th, 2025.
Action required: 705 - Other - as specified
Due 14 October 2025
Resolved 14 October 2025
Resolution: CG-835V expired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 September 2025 Resolved
During vessel operation, vessels horn appeared to sound weak and distorted. Horn shall be audible for one-half nautical mile.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 18 September 2025
Resolution: Received text from vessel rep stating that a new horn was installed and working.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2025 Resolved
Remote fuel oil shutoff valve was inoperable. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2025
Resolved 23 June 2025
Resolution: Vessel crew rectified the deficiency on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2025 Resolved
Battery cables on the port and stbd main engine switches were sound to be very loose. Other battery connections and one other switch was found to have very loose battery cable connections. Connectors must be secured to prevent loosening due to vibration.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 June 2025
Resolved 24 June 2025
Resolution: Crew tightened all loose battery cable connections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2025 Resolved
Found lifejacket locker door handle that is able to be locked. Each storage container for life jackets must not be capable of being locked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 21 July 2025
Resolution: Verified with vessel rep that the door knob to the lifejacket storage was replaced with non-lockable door knob.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 June 2025 Resolved
Port main propulsion engine found to be missing alternator safety guard. An exposed hazard, such as gears or rotating machinery, must be protected by a cover or rail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 11 August 2025
Resolution: Crew installed newly built guard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. The vessels whistle was inoperable due to weathering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 11 June 2024
Resolution: Installed new whistle. All sat
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. Vessel did not have a U.S. Coast Pilot on board
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: MI emailed copy of coast pilot to vessel owner
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 June 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel did not have a first aid kit that met the requirements of 46 CFR 199.75(b)(10) or a kit with equivalent contents and instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 2 July 2025
Resolution: New first aid kit installed. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Vessels marker light lanyard was dry rotted and not serviceable
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: Vessel owner replaced lanyard on marker light
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2024 Resolved
(d) Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Vessels fire hose nozzle was not servicable when tested owner needs to replace nozzle folling the above regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 10 October 2024
Resolution: New nozzle installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2024 Resolved
(b)(4)All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Vessel had a wire secured using zip tie in overhead of engine room, change zip ties to approved supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 10 October 2024
Resolution: Metal supports installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel had 17 non-serviceable adult lifejackets on board
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: Vessel owner replaced all non-serviceable life jackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 June 2024 Resolved
Frequency meter on the main bus panel was not working during the operation of the generator on vessel power. For each alternating current generator, a means for measuring frequency must be provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 23 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023 Resolved
Frequency meter on the main bus panel was not working during the operation of the generator on vessel power. For each alternating current generator, a means for measuring frequency must be provided.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 12 July 2023
Resolution: Frequency meter working correctly. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023 Resolved
Electrical power available indicator light on the main bus panel was not working in either shore power or vessel power. Electrical equipment on a vessel must be installed and maintained to: protect crew from electrical hazards.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 12 July 2023
Resolution: Light has been replaced, all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2022 Resolved
Found handles on engine room hatch froze. Watertight hatch handles should move freely enabling hatch to properly close and make watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Crew disassembled, lubricated and reassembled hatch dogs. Chalk tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 April 2022 Resolved
Found electrical wires in deck penetration into engine room behind bar area near engine room hatch had no fire rated caulk.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Crew installed fire rated caulk in wire penetrations.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 July 2020 Resolved
First aid kit was found with missing or expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Rep purchased new first aid kits.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 July 2020 Resolved
Vessel did not have required navigation publications on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Updated nav publications were placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2020 Resolved
Portable fire extinguishers were found not having monthly inspections as required by NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Crew starting to complete monthly portable fire extinguisher maintenance.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 July 2019 Resolved
Remote fuel shutoff valve cable was found to be difficult to operate. Cable worked to close the fuel valve after multiple tries. Cable was difficult to reset. Replace/Repair cable to ensure frictionless operation of cable in either direction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2019
Resolved 24 July 2019
Resolution: Maintenance crew installed new remote cable. Remote shut-off operates freely in both directions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2019 Resolved
Found loose battery connections of auxiliary wires. Reconnect wires to ensure all fittings are tight to the battery terminal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Vessel crew tightened loose battery connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2018 Resolved
Stbd propulsion engine failed to restart after securing running engine. Vsl rep suspected an inoperable starter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 July 2018
Resolved 11 July 2018
Resolution: Crew removed old starter and replaced with spare starter. Tested engine in the presence of the Marine Inspector. Test satisfactory.
Engineering › Lubricating Oil Service System › Gauge
Issued 20 June 2017 Resolved
Oil pressure gauge at the operating station found not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 24 July 2017
Resolution: New gauge, wiring, and sending unit were installed and are currently working.
Operations/Management › Drills/Instruction › Fire
Issued 5 May 2016 Resolved
Conduct fire and man-overboard drills with summer crews.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 22 June 2016
Resolution: Witnessed fire and man overboard drills.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 5 May 2016 Resolved
Provide proof of DAPI testing results for CY-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 22 June 2016
Resolution: Conducted annual DAPI Audit.
Construction/Loadline › Structures › Ventilators
Issued 16 May 2012 Resolved
Provide weather tight closure device for cowl vent for lazarette.
Action required: 705 - Other - as specified
Due 1 May 2013
Resolved 7 March 2013
Resolution: Weather tight closure installed - SAT.
Construction/Loadline › Structures › Scuttle
Issued 16 May 2012 Resolved
Replace gasket for lazarette hatch.
Action required: 705 - Other - as specified
Due 4 June 2012
Resolved 7 June 2012
Resolution: Witnessed new gasket installed tested sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2012 Resolved
Install guard for MDE belts
Action required: 705 - Other - as specified
Due 1 May 2013
Resolved 7 March 2013
Resolution: Guards installed - SAT.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2009 Resolved
Fire control plan not posted. Post a fire control plan in a conspicuous location accessible to all passengers.
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 14 August 2009
Resolution: Verified presence of FCP.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2004 Resolved
Correct mounting of STBD Navigation light; Vessel is restricted to daylight operation or times without limited visability.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 June 2004
Resolution: Company installed new base and verified by CG inspector
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2004 Resolved
Prove proper installation of appropriate navigation lights IAW 46 CFR 120.420.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 22 June 2005
Resolution: After researching 46 CFR 120.420 , requirement does not apply due to length of vessel (fixture is a UL 1104 fixture with household bulb installed). Company rep and owner have new approved lights on order and are awaiting arrival for replacement.
Lifesaving
Issued 29 March 2000 Resolved
Vessel limited to operation with 172 adult and 14 child passengers. Provide 58 adult and 9 child size type I PFDs.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Engineering
Issued 21 July 1999 Resolved
Correct starboard engine shift cable installation prior to carrying passengers.
Condition: Unknown
Due 21 July 1999
Resolved 26 August 1999
Lifesaving
Issued 10 May 1999 Resolved
Clean/Replace Retro-Reflective tape 19 Adult 1 Child. Passenger count to be reduced by these numbers until corrected.
Condition: Unknown
Due 14 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 10 May 1999 Resolved
Ensure all portable fire extingushers are in brackets.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 11 March 1999 Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REGULATIONS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 14 May 1998 Resolved
CLEAN AND TIGHTEN LOOSE BATTERY TERMINALS ON GENERATOR STARTING BATTERY, CORRECTED ON SPOT.
Condition: Unknown
Due 28 May 1998
Resolved 1 July 1998
Engineering
Issued 14 May 1998 Resolved
PROVIDE MACHINERY GUARDS OVER ALTERNATOR DRIVE PULLEYS ON BOTH MAIN ENGINESBEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 May 1998
Resolved 1 July 1998
Electrical
Issued 14 May 1998 Resolved
INSTALL GLOBE AND GUARD ON LIGHTING FIXTURE OUTBOARD OF PORT MAIN ENGINE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 May 1998
Resolved 1 July 1998
Electrical
Issued 14 May 1998 Resolved
EMERGENCY LIGHTING FLASHLIGHTS INOPERABLE, CORRECTED ON SPOT.
Condition: Unknown
Due 28 May 1998
Resolved 1 July 1998
Lifesaving
Issued 14 May 1998 Resolved
PROVIDE BUOYANT LIFELINE FOR RING BUOY AS PER 46 CFR 180.70 BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 May 1998
Resolved 1 July 1998
Electrical
Issued 14 July 1997 Resolved
REPAIR BATTERY BOX, CORRECTED ON SPOT.
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Navigation
Issued 14 July 1997 Resolved
PROVE PROPER OPERATION OF MAGNETIC COMPASS PRIOR TO THE COMPLIANCE DATE. UNTIL CORRECTED, THE COMPASS MUST BE REMOVED FROM THE VESSEL.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Construction/Loadline
Issued 17 May 1995 Resolved
Relabel bilge manifold valves.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Lifesaving
Issued 17 May 1995 Resolved
Demonstrate Fire and lifesaving drills.
Condition: Unknown
Due 17 May 1995
Resolved 17 May 1995
Lifesaving
Issued 30 June 1994 Resolved
Restencil child life jacket lockers.
Condition: Unknown
Due 1 July 1994
Resolved 5 July 1994
Lifesaving
Issued 30 June 1994 Resolved
Reposition life ring to aft end of vsl.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Documentation
Issued 30 June 1994 Resolved
Repost Stability Letter
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Documentation
Issued 30 June 1994 Resolved
Repost Emergency Check Off List.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Electrical
Issued 30 June 1994 Resolved
Prove 12 Volt DC system.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Fire Fighting
Issued 2 July 1993 Resolved
Complete fire load plan review - until completed, vsl limited to 150 passengers.
Condition: Unknown
Due 17 August 1993
Resolved 26 July 1993
Documentation
Issued 2 July 1993 Resolved
Conduct simplified stability test.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Navigation
Issued 2 July 1993 Resolved
Fix/replace installed horn - until corrected, portable horn to remain O/B.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Navigation
Issued 2 July 1993 Resolved
Relocate running lights to comply with rules of the road.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Engineering
Issued 2 July 1993 Resolved
Repair Stbd Tach and Port Gear Oil Pressure Gauge.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Construction/Loadline
Issued 2 July 1993 Resolved
Clean Threads of Paint, Engine Room Escape Hatch.
Condition: Unknown
Due 20 July 1993
Resolved 26 July 1993
Fire Fighting
Issued 2 July 1993 Resolved
Reweigh CO2 extinguisher marked "5", NLT 14 JUL 93.
Condition: Unknown
Due 20 July 1993
Resolved 26 July 1993
Lifesaving
Issued 2 July 1993 Resolved
Complete Stenciling of Life Jackets NLT 14 July 1993
Condition: Unknown
Due 20 July 1993
Resolved 26 July 1993
Lifesaving
Issued 2 July 1993 Resolved
Complete Labeling of Aft life Jacket Locker NLT 14 Jul 93.
Condition: Unknown
Due 20 July 1993
Resolved 26 July 1993
Engineering
Issued 14 May 1992 Resolved
Remove or replace with metal the jplastic "puke cans" on port MDE.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Accommodation/Occupational Safety
Issued 14 May 1992 Resolved
Demonstrate Toilets & Sinks
Condition: Unknown
Due 15 May 1992
Resolved 19 May 1992
Engineering
Issued 14 May 1992 Resolved
Demonstrate operation of F/O shutdown
Condition: Unknown
Due 15 May 1992
Resolved 19 May 1992
Lifesaving
Issued 14 May 1992 Resolved
Repair/replace hasps on upper life jacket locker.
Condition: Unknown
Due 15 May 1992
Resolved 19 May 1992

Casualty record · 3

20 August 2020Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 7041644
16 April 2022Routine · role: Involved in a Marine Casualty · activity 7582752
12 May 2026Routine · role: Involved in a Marine Casualty · activity 8390708
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.