Records from 2016 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 35
12 May 2026
Type not recorded
No type recorded · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8390708
4 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8361256
27 April 2026
Vessel Attendance · COI Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8350264
23 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8257721
6 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8247376
17 September 2025
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8236549
23 June 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8164346
27 March 2025
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8128930
24 February 2025
Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8085210
10 February 2025
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8085781
10 February 2025
Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8088220
24 September 2024
In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8010272
10 June 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7931558
6 December 2023
Plan Review (Other than "T") · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7834500
14 November 2023
Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7885899
3 October 2023
In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7802350
24 July 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7764956
22 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7694197
18 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7691121
28 October 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7585328
19 May 2022
MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7473613
20 April 2022
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7430062
16 April 2022
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7582752
29 June 2021
DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7239026
11 May 2021
COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7188365
12 November 2020
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7093337
20 August 2020
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7041644
16 July 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7007981
19 May 2020
Administrative Inspection · Drydock Extension
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6960774
15 July 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6712616
18 July 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6483677
11 July 2018
In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6474614
20 June 2017
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6181050
22 June 2016
Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916245
3 May 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5867936
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2026
Resolved
The vessel is permitted temporary manning allowance and deviate from the manning requirements set forth in the Certificate of Inspection (COI) reducing the manning to:
* 01 Master
* 01 Deckhand
Conditions of Deviation:
* Vessel passenger count is reduced to 90
* The upper deck must remain secured at all times.
* No passengers are permitted on the second deck under any circumstances during operations, unless an emergency situation dictates.
This manning reduction is authorized under the condition that the vessel operates within the limitations specified above. Failure to comply with these conditions may result in the revocation of this authorization. This CG-835V is valid until July 1st, 2026.
Action required: 705 - Other - as specified
Due 1 July 2026
Resolved 16 June 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2025
Resolved
The vessel is permitted temporary manning allowance and deviate from the manning requirements set forth in the Certificate of Inspection (COI) reducing the manning to:
* 01 Master
* 01 Deckhand
Conditions of Deviation:
* Vessel passenger count is reduced to 90
* The upper deck must remain secured at all times.
* No passengers are permitted on the second deck under any circumstances during operations, unless an emergency situation dictates.
This manning reduction is authorized under the condition that the vessel operates within the limitations specified above. Failure to comply with these conditions may result in the revocation of this authorization. This CG-835V is valid until October 14th, 2025.
Action required: 705 - Other - as specified
Due 14 October 2025
Resolved 14 October 2025
Resolution: CG-835V expired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 September 2025
Resolved
During vessel operation, vessels horn appeared to sound weak and distorted. Horn shall be audible for one-half nautical mile.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 18 September 2025
Resolution: Received text from vessel rep stating that a new horn was installed and working.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2025
Resolved
Remote fuel oil shutoff valve was inoperable.
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2025
Resolved 23 June 2025
Resolution: Vessel crew rectified the deficiency on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2025
Resolved
Battery cables on the port and stbd main engine switches were sound to be very loose. Other battery connections and one other switch was found to have very loose battery cable connections. Connectors must be secured to prevent loosening due to vibration.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 June 2025
Resolved 24 June 2025
Resolution: Crew tightened all loose battery cable connections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2025
Resolved
Found lifejacket locker door handle that is able to be locked. Each storage container for life jackets must not be capable of being locked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 21 July 2025
Resolution: Verified with vessel rep that the door knob to the lifejacket storage was replaced with non-lockable door knob.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 June 2025
Resolved
Port main propulsion engine found to be missing alternator safety guard. An exposed hazard, such as gears or rotating machinery, must be protected by a cover or rail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 11 August 2025
Resolution: Crew installed newly built guard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle.
The vessels whistle was inoperable due to weathering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 11 June 2024
Resolution: Installed new whistle. All sat
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication.
Vessel did not have a U.S. Coast Pilot on board
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: MI emailed copy of coast pilot to vessel owner
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 June 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Vessel did not have a first aid kit that met the requirements of 46 CFR 199.75(b)(10) or a kit with equivalent contents and instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 2 July 2025
Resolution: New first aid kit installed. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Vessels marker light lanyard was dry rotted and not serviceable
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: Vessel owner replaced lanyard on marker light
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2024
Resolved
(d) Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, must:
(1) Be of a type approved in accordance with approval series 162.027; or
(2) Be of a type recognized by the Commandant as being equivalent in performance.
Vessels fire hose nozzle was not servicable when tested owner needs to replace nozzle folling the above regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 10 October 2024
Resolution: New nozzle installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2024
Resolved
(b)(4)All cable and wire must:
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
Vessel had a wire secured using zip tie in overhead of engine room, change zip ties to approved supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 10 October 2024
Resolution: Metal supports installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
The vessel had 17 non-serviceable adult lifejackets on board
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: Vessel owner replaced all non-serviceable life jackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 June 2024
Resolved
Frequency meter on the main bus panel was not working during the operation of the generator on vessel power.
For each alternating current generator, a means for measuring frequency must be provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 23 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023
Resolved
Frequency meter on the main bus panel was not working during the operation of the generator on vessel power.
For each alternating current generator, a means for measuring frequency must be provided.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 12 July 2023
Resolution: Frequency meter working correctly. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023
Resolved
Electrical power available indicator light on the main bus panel was not working in either shore power or vessel power.
Electrical equipment on a vessel must be installed and maintained to: protect crew from electrical hazards.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 12 July 2023
Resolution: Light has been replaced, all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2022
Resolved
Found handles on engine room hatch froze. Watertight hatch handles should move freely enabling hatch to properly close and make watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Crew disassembled, lubricated and reassembled hatch dogs. Chalk tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 April 2022
Resolved
Found electrical wires in deck penetration into engine room behind bar area near engine room hatch had no fire rated caulk.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Crew installed fire rated caulk in wire penetrations.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 July 2020
Resolved
First aid kit was found with missing or expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Rep purchased new first aid kits.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 July 2020
Resolved
Vessel did not have required navigation publications on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Updated nav publications were placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2020
Resolved
Portable fire extinguishers were found not having monthly inspections as required by NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Crew starting to complete monthly portable fire extinguisher maintenance.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 July 2019
Resolved
Remote fuel shutoff valve cable was found to be difficult to operate. Cable worked to close the fuel valve after multiple tries. Cable was difficult to reset. Replace/Repair cable to ensure frictionless operation of cable in either direction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2019
Resolved 24 July 2019
Resolution: Maintenance crew installed new remote cable. Remote shut-off operates freely in both directions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2019
Resolved
Found loose battery connections of auxiliary wires. Reconnect wires to ensure all fittings are tight to the battery terminal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Vessel crew tightened loose battery connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2018
Resolved
Stbd propulsion engine failed to restart after securing running engine. Vsl rep suspected an inoperable starter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 July 2018
Resolved 11 July 2018
Resolution: Crew removed old starter and replaced with spare starter. Tested engine in the presence of the Marine Inspector. Test satisfactory.
Engineering › Lubricating Oil Service System › Gauge
Issued 20 June 2017
Resolved
Oil pressure gauge at the operating station found not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 24 July 2017
Resolution: New gauge, wiring, and sending unit were installed and are currently working.
Operations/Management › Drills/Instruction › Fire
Issued 5 May 2016
Resolved
Conduct fire and man-overboard drills with summer crews.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 22 June 2016
Resolution: Witnessed fire and man overboard drills.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 5 May 2016
Resolved
Provide proof of DAPI testing results for CY-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 22 June 2016
Resolution: Conducted annual DAPI Audit.