Records from 1982 to 2018. Most recent: inspection, 2 March 2018.
Inspection history · 97
2 March 2018
Administrative Inspection · Loadline Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6366136
10 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5040178
18 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4826032
8 June 2012
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4337848
4 June 2012
Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4327377
29 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4327472
20 December 2011
Random ISPS/MTSA/PSC
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4217520
29 March 2010
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3717300
14 April 2009
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3480945
3 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3356411
25 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3332390
8 April 2008
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3189641
26 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974745
13 April 2007
COC-MODU Renew
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2907139
6 March 2007
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2883379
27 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2599222
27 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2601575
7 December 2005
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547478
7 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2509852
13 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2311356
23 November 2004
COC-MODU Renew
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2249593
22 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2190320
1 March 2004
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2015633
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764338
18 December 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1720802
7 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1685971
22 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678548
28 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667998
6 March 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1611600
5 December 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076978
31 October 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410687
26 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073181
10 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050350
13 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817772
1 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812497
4 November 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442900
30 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23854
17 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 33048
28 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077972
4 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 144711
28 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126046
10 November 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444075
21 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802439
8 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791142
13 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776726
14 October 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404460
22 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114782
13 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106362
13 February 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1106213
6 January 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096501
16 December 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096447
4 December 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188927
20 November 1996
Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400452
27 November 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380345
11 April 1995
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1157458
30 March 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833729
30 March 1995
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440918
5 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407408
21 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165593
24 January 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163116
30 November 1993
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356458
28 October 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141384
13 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 172708
9 December 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 829360
25 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136224
17 January 1992
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 962729
30 October 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 938724
30 October 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1136490
30 October 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1249292
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237886
13 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914968
4 December 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1228002
14 November 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 913524
14 December 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928829
10 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349226
5 April 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 896318
18 November 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 895727
26 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342820
12 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328508
21 October 1987
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1309609
8 June 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1339189
28 April 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025110
9 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014165
18 November 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316915
30 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314392
15 October 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012592
25 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984882
20 May 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1291444
29 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290258
23 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980664
22 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976399
16 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975225
17 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280137
18 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274025
9 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964911
22 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969210
21 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276593
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 4 June 2012
Resolved
Ensure vessel submits evidence of required fuel oil transfer hose annual hydrostatic tests.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 8 June 2012
Resolution: Vessel submited required annually hydrostatic testing reports for both port and starboard fuel transfer hoses.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 June 2012
Resolved
Ensure drip shields are replaced on top of motor controllers located in mud pump room.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 8 June 2012
Resolution: Vessel installed proper drip shields above motor controllers located in the mud pump room.
Stability › Watertight Integrity › General
Issued 4 June 2012
Resolved
Ensure bulkhead penetrations between mud pump room and mudpits is made watertight and gas tight.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 8 June 2012
Resolution: Vessel installed proper sealing in bulkhead wire penetrations between mud pit room and mud pump room to ensure watertight and gastight integrity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 June 2012
Resolved
Ensure instruction cards for paint locker and engine room bilge fire fighting systems are made understandable.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 8 June 2012
Resolution: Properly and clearly marked instruction cards were installed on both paint locker and engine room bilge fixed fire fighting systems.
Construction/Loadline › Hull › Hull Plating
Issued 20 December 2011
Resolved
Column 4 hull plating is severely corroded in the sump area. Corrosion is concentrated in the aft portion of the vertical plating. Wastage is severe to the point of the plating being 'holed' in one area. Renew wasted plating. Gauge area to ensure all excessive corrosion has been removed. Code 0983. 79 MODU Code 1.6.7. Action 40a,c.
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2012
Resolution: Verifired repairs of severly corroded area located in Column 4. Insert was 2ft x 2ft x 3/8 inch plate. ABS submitted report to vessel representative. Repairs were examined , tested using (UT) and considered satisfactory.
Stability › Water on Deck › General
Issued 20 December 2011
Resolved
Remote deck drain valves in all six columns are inoperable. One reach rod in Column 1 has been cut off. Make appropriate repairs and prove proper operation off all remote valves in each column. Code 0930. 79 MODU Code 3.6.2. Action 16a,c.
Action required: 705 - Other - as specified
Due 3 January 2012
Resolved 30 December 2011
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 7 December 2005
Resolved
Provide proof of 5 year pressure vessel inspection completed to satisfaction of flag state representative.
Due 31 January 2006
Resolved 19 January 2006
Resolution: Class Society completed satisfactory internal examination.
Lifesaving
Issued 31 October 2001
Resolved
Conduct release gear test on MASECO Release Gear ( lifeboat ) _x001C_ _x001C_ This is reissue of mi00033684, CORMS, 01 NOV 00 to do same.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Unknown
Issued 31 October 2001
Resolved
Renew wasted mud pit room door.
Condition: Unknown
Due 31 October 2001
Resolved 31 October 2001
Unknown
Issued 10 November 1998
Resolved
REPAIR LEAK IN POTABLE WATER SUPPLY PUMP TP BOP CONTROL.
Condition: Unknown
Due 12 November 1998
Resolved 19 November 1998
Lifesaving
Issued 10 November 1998
Resolved
CONDUCT 1.1 RELEASE GEAR OPERATIONAL TEST OF ALL THREE LIFEBOATS. ALTERNATETEST MUST BE APPROVED VIA THE CONNIZANT OCMI.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Electrical
Issued 10 November 1998
Resolved
PROVIDE PROPER POSITIVE VENTILATION FOR MUD PITS. REPAIR VENTILATION FAN INMUD PUMP ROOM.
Condition: Unknown
Due 12 November 1998
Resolved 19 November 1998
Unknown
Issued 10 November 1998
Resolved
ON PORT CRANE: REPLACE ONE MISSING AND ONE BROKEN WINDOW ON CAB. REPLACE ORGAUGE AIR RECEIVER AND RENEW SAFETY RELEIF VALVE. PROPERLY SECURE AND DEAD END MAIN AND AUXILIARY HOIST WHIPS TO API 2D STANDARDS.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Unknown
Issued 10 November 1998
Resolved
CONDUCT ANNUAL ABS CRANE INSPECTION AND LOADLINE SURVEY. FORWARD COPIES OF ENDORSED CERTIFICATES TO THE [name withheld].
Condition: Unknown
Due 12 November 1998
Resolved 16 November 1998
Electrical
Issued 10 November 1998
Resolved
CONDUCT AND LOG TOTAL RIG SHUT-DOWN.
Condition: Unknown
Due 12 November 1998
Resolved 19 November 1998
Unknown
Issued 10 November 1998
Resolved
PROPERLY SEAL WIRE CABLE RUN PENETRATIONS THROUGH EXTERIOR ACCOMMODATION SPACES AND THROUGH NEW ADDITION TO TOOL PUSHER'S OFFICE.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Unknown
Issued 10 November 1998
Resolved
AMEND FIRE CONTROL AND SAFETY PLAN TO REFLECT MISSING LIFESAVING SYMBOLOGY.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 10 November 1998
Resolved
CROP AND RENEW AS ORIGINAL THREE HOLES IN BOTTOM PLATE BELOW THE BOP CONTROL ROOM. PROVIDE INSERTS NO LESS THAN 18" X 18" WITH RADIUSED CORNERS.
Condition: Unknown
Due 12 November 1998
Resolved 19 November 1998
Fire Fighting
Issued 10 November 1998
Resolved
CROP AND RENEW FIREMAIN PIPING AT ELBOW, WHERE LEAKING, ON HYDRANT NO. 6, TEMPORARILY PATCH PIPE UNTIL PERMANENT REPAIRS CAN BE EFFECTED, TO THE SATISFACTION OF ABS SURVEYOR OR COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 November 1998
Resolved 19 November 1998
Lifesaving
Issued 14 October 1997
Resolved
CONDUCT TRAINING IN USE OF DAVIT LAUNCHED LIFERAFTS EVERY 4 MONTHS PER 46CFR109.213(G)(5).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 14 October 1997
Resolved
MAKE REPAIRS TO PORT, OUTBOARD BALLAST TANK #9 IN PONTOON TO SATISFACTON OFCLASS SOCIETY.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997
Resolved
PROVIDE TRAINING MATERIAL ON BOARD PER 46CFR109.213.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997
Resolved
IMPLEMENT POLICY FOR OIM TO PLACE A LOG ENTRY WHEN REQUIRED TRAINING AND DRILLS ARE NOT CONDUCTED, PER 46CFR109.213(H)(2).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 14 October 1997
Resolved
REPLACE MISSING VENT COVER DOGS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997
Resolved
MAKE APPROPRIATE CHANGES TO SOPEP AND PROVIDE ABS APPROVAL.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Engineering
Issued 14 October 1997
Resolved
INSTALL FLAME BOWLS ON RACOR FUEL FILTERS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Engineering
Issued 14 October 1997
Resolved
INSTALL GLASS SIGHT GAUGE AND PROPER GUARDS ON GENERATOR DAY TANKS AND EMERGENCY GENERATOR FUEL TANK.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Electrical
Issued 14 October 1997
Resolved
REPLACE EMERGENCY GENERATOR FREQUENCY METER.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997
Resolved
PROVIDE LOGS AND/OR CONDUCT TESTS: 2 HR. EMER. GEN. LOAD TEST, 2 HR. EMER. BATT. LOAD TEST, EPIRB MAINT., LINE-THROWING GUN TRAINING.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 14 October 1997
Resolved
SEAL MUD PIT BULKHEAD PENETRATIONS AND MAKE MUD PIT DOOR GAS TIGHT. REVISE HAZARDOUS LOCATION PLAN TO INCLUDE PENETRATION IN MUD PIT OVERHEAD.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Fire Fighting
Issued 14 October 1997
Resolved
PROVIDE PROOF OF ANNUAL FOAM ANALYSIS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 14 October 1997
Resolved
RENEW WASTED FRAMING SUPPORTS OF WALKWAYS AROUND ANCHOR CABLES BELOW MAIN DECK.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 14 October 1997
Resolved
CROP AND RENEW WASTED SHAKER HOUSE BULKHEAD AND REPLACE MISSING BOLTS FROM EXPLOSION PROOF FITTINGS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 20 November 1996
Resolved
Conduct internal examination on all unfired pressure vessels (UPVs) including: high-pressure air receivers for tensioners/compensators, ship's service (rig air) receivers and P-tanks. Conduct pressure testing of all respective pressure relief valves.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Lifesaving
Issued 20 November 1996
Resolved
Lower, release and operate lifeboat and both capsules in water as soon as weather permits but no later than 20DEC96.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Engineering
Issued 20 November 1996
Resolved
Provide positive mechanical closure (threaded plug or cap) on each containment surrounding fuel tank vents.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Lifesaving
Issued 20 November 1996
Resolved
Replace missing and expired or deteriorated emergency provisions in lifeboat and both capsules. Per IMO MODU Code, must have 2400 calories (10,000 kj) per person per marked capacity on each lifeboat/capsule.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Lifesaving
Issued 27 November 1995
Resolved
RENEW GENERAL ALARM BELLS IN SHAKER HOUSE AND MUD PIT ROOM.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Electrical
Issued 27 November 1995
Resolved
REPLACE BATTERIES IN BATTERY OPERATED EMERGENCY LIGHTS AS NEEDED.
Condition: Unknown
Due 1 December 1995
Resolved 1 December 1995
Documentation
Issued 27 November 1995
Resolved
PROVIDE COPY OF APPROVED OPERATIONS MANUAL AND FULL TERM SAFETY CERTIFICATE.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Construction/Loadline
Issued 30 March 1995
Resolved
Provide proof of Class Society acceptence in way of new installation of gas-tight mud room/pit room doors. Doors are currently installed without gaskets and are sealed with silicon sealant bead-applied along seam of low-pressure side of the assemblies.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Electrical
Issued 5 December 1994
Resolved
REPAIR/REPLACE PIT ROOM TO PUMP ROOM DOORS SO THAT THEY ARE GAS TIGHT.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994
Resolved
PROVIDE/REPAIR EMERGENCY LIGHTING FOR SURVIVAL CAPSULES AND RAFTS (BOW) EMBARKATION AREAS.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Electrical
Issued 5 December 1994
Resolved
MAKE STBD AFT OBSTRUCTION LIGHT QUICK-FLASHING WHITE IN SYNC WITH OTHER LIGHTS.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 5 December 1994
Resolved
PROVIDE ALL LIFERAFTS WITH FLOAT FREE ARRANGEMENT IN ACCORDANCE WITH PANAMANIAN TECH NOTE 1/83 PART B.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 5 December 1994
Resolved
PROVIDE WEIGHT FOR ALL SURVIVAL CRAFT HEAVING LINES.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 5 December 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF BOTH SURVIVAL CRAFT SPRINKLER SYSTEMS.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Electrical
Issued 5 December 1994
Resolved
PROPERLY INSTALL MUD MONITOR BOX, J-BOX, LIGHT FIXTURE, AND WIRE RUN FOR GAS DETECTOR IN MUD PIT ROOM.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 5 December 1994
Resolved
STENCIL LIFERAFT EMBARKATION AREA WITH RAFT NUMBER AND CAPACITY.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Fire Fighting
Issued 30 November 1993
Resolved
REPAIR FIRE STATIONS #15 AND 19 (PRESENTLY NO WATER TO STATIONS), FIX NOZZLE ON STATION #17, AND TIGHTEN PACKING ON STATION #14.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Navigation
Issued 30 November 1993
Resolved
PAINT NAV. LIGHT SCREENS MATT BLACK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Fire Fighting
Issued 30 November 1993
Resolved
SERVICE O2/EXPLOSION METERS.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Accommodation/Occupational Safety
Issued 30 November 1993
Resolved
HYDRO OXYGEN BOTTLES IN HOSPITAL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Deck/Cargo
Issued 30 November 1993
Resolved
PROVIDE FORKLIFT TYPE DESIGNATION CERTIFICATION FROM UL OR FM (D, DS, E, EE, OR EX).
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Accommodation/Occupational Safety
Issued 30 November 1993
Resolved
MAKE ALL PRESSURE VESSELS AVAILABLE FOR INTERNAL EXAMINATION AND ALL RELIEFVALVES TESTED IN THE PRESENCES OF COGNIZANT MARINE INSPECTOR.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Lifesaving
Issued 30 November 1993
Resolved
CONDUCT TOTAL RIG SHUT DOWN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Construction/Loadline
Issued 30 November 1993
Resolved
RENEW PACKING AND REPLACE M0TOR END GUARD ON STARBOARD SALT WATER SERVICE PUMP._x001C_
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Electrical
Issued 30 November 1993
Resolved
TEST ALL EMERGENCY LIGHTS ON THE EMERGENCY CIRCUIT.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Accommodation/Occupational Safety
Issued 30 November 1993
Resolved
REPAIR STARBOARD ELEVATOR ALARM.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Fire Fighting
Issued 30 November 1993
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS: 1. SACK ROOM 2. MUD PIT ROOM_x001C_ 3. SUBSEA CONTROL ROOM 4. SHAKER HOUSE 5. STAR. CRANE TUB. 6. MOON POOL WALL
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Accommodation/Occupational Safety
Issued 30 November 1993
Resolved
REPAIR AND TEST THE MUD PIT VENTILATION SHUTDOWN.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Construction/Loadline
Issued 30 November 1993
Resolved
MAKE REPAIRS OR REPLACE STARBOARD BILGE PUMP HIGH WATER ALARM
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Engineering
Issued 30 November 1993
Resolved
PROVE FUEL TRANSFER HOSES FOR "FUEL SERVICE" AND ANNUAL HYDRO DATE (1 1/2 TIMES MAWP).
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Lifesaving
Issued 30 November 1993
Resolved
REPLACE AIR BOTTLES IN #1 LIFEBOAT. SECURE ALL EQUIPMENT. INSTALL MONKEY FIST ON HEAVING LINES. REPLACE L/B #1 OPERATION MANUAL. CLEAN TOOLS IN TOOL KIT.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Lifesaving
Issued 30 November 1993
Resolved
SERVICE LIFERAFTS AND DAVIT HOOK. CONDUCT WEIGHT TEST OF THE LIFERAFT DAVIT.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Fire Fighting
Issued 30 November 1993
Resolved
INSTALL RELIEF VALVE ON FIRE PUMP (MAX. 125PSI).
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Electrical
Issued 30 November 1993
Resolved
REPLACE MISSING METAL GUARDS ON HELO. PERIMETER LIGHTS.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Documentation
Issued 30 October 1991
Resolved
PROVIDE CURRENT ABS LOADLINE CERTIFICATE.
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Deck/Cargo
Issued 30 October 1991
Resolved
PROVIDE UPDATED OPERATING MANUAL FOR USCG REVIEW.
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Documentation
Issued 30 October 1991
Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE TEST EXAMINATION.
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Documentation
Issued 30 October 1991
Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE TEST EXAMINATION.
Condition: Unknown
Due 15 December 1991
Resolved 17 January 1992
Documentation
Issued 30 October 1991
Resolved
PROVIDE CURRENT ABS LOADLINE CERTIFICATE.
Condition: Unknown
Due 15 December 1991
Resolved 17 January 1992
Documentation
Issued 30 October 1991
Resolved
PROVIDE UPDATED OPERATING MANUAL FOR USCG REVIEW.
Condition: Unknown
Due 15 December 1991
Resolved 17 January 1992
Fire Fighting
Issued 14 November 1990
Resolved
PROVIDE COPY OF FOAM SAMPLE ANALYSIS REPORT TO [name withheld].
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
INSTALL WEAK LINK ON #3 LIFEBOAT.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Deck/Cargo
Issued 14 November 1990
Resolved
PROVIDE COPIES OF ANNUAL SURVEY ON ALL 3 CRANES.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Electrical
Issued 14 November 1990
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON GENERATORS #1,2,3.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
WEIGHT TEST #1 AND #2 LIFECAPSULES AND #1 LIFEBOAT.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
REPAIR GENERAL ALARM BELLS IN SACK ROOM, MOON POOL, AND PIPE RACK AREA.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
END FOR END #1 LIFEBOAT FALLS.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Engineering
Issued 14 November 1990
Resolved
OPEN AND MAKE AVAILABLE FOR INTERNAL INSPECTION ALL AIR RECEIVERS, DRYBULK TANKS, MOTION COMPENSATOR APVIS, AND RISER RENSIONER APV'S.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Engineering
Issued 14 November 1990
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON ALL AIR RECEIVERS, DRYBULK TANKSAND RISER TENSIONER APV'S.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Electrical
Issued 14 November 1990
Resolved
MAKE PERMANENT REPAIRS TO PURGE AIR ALARM ON MUD PUMP FLOW CONSOLE ON DRILLFLOOR DRILLERS STATION.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Fire Fighting
Issued 14 November 1990
Resolved
INSTALL ONE 4LB DRY CHEMICAL PORTABLE FIRE EXTINGUISHER ON THE FORKLIFT
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Fire Fighting
Issued 14 November 1990
Resolved
PROVIDE ONE 4LB DRY CHEMICAL PORTABLE FIRE EXTINGUISHER AT FORKLIFT REFUELING STATION IN SACK ROOM IAW 46CFR109.537(E).
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Fire Fighting
Issued 14 November 1990
Resolved
REMOVE HOSE AND PISTOL GRIP DEADMAN NOZZLE FROM FORKLIFT REFUELING STATION IN SACK ROOM AND PROVIDE A PORTABLE CONTAINER OF 5 GALLONS OR LESS WITH A SELF CLOSING SPOUT IAW 46CFR109.537(D).
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Accommodation/Occupational Safety
Issued 14 November 1990
Resolved
PROVE PROPER OPERATION OF MACHINERY SPACE REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Engineering
Issued 14 November 1990
Resolved
PROVIDE DOCUMENTATION PROVING BOTH OILY WATER SEPARATORS ARE USCG APPROVED UNITS AND OPERATE IAW 33CFR155.900.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 November 1990
Resolved
REPLACE WATER IN #1 LIFEBOAT.
Condition: Unknown
Due 14 November 1990
Resolved 14 November 1990
Lifesaving
Issued 14 December 1989
Resolved
DVAITS FOR CAPSULES 1&2 ARE HEAVILY RUSTED AT WELD AREAS. DERUST AS NEEDED.WELD AREA AS NESSARY.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Lifesaving
Issued 14 December 1989
Resolved
PROVIDE SMOKE FOR CAPSULE #1 AND HAND HELD FLARES.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Lifesaving
Issued 14 December 1989
Resolved
PROVIDE HAND HELD FLARES FOR CAPSULE #2
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Electrical
Issued 14 December 1989
Resolved
PROVIDE A APPROVED DRAWING FOR THE FIXED PRESSURE SYSTEM SUB SEA MONITER USED ON THE DRILL FLOOR. MUST COMPLY WITH NFPA 496 AS WELL. (FOR SUB SEA CONTRACTOR ONLY)
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Construction/Loadline
Issued 14 December 1989
Resolved
REPLACE THE MUD PIT DOOR WHICH IS WASTED ON THE BOTTOM.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Unknown
Issued 14 December 1989
Resolved
REPLACE THE OVERHEAD HATCH COVER IN BOTH ELEVATORS, INSTALL INTER LOCK SO ELEVATOR IS DISABLED WHEN HATCH IS OPEN.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Fire Fighting
Issued 14 December 1989
Resolved
REPAIR THE STBD FIRE PUMP.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Electrical
Issued 14 December 1989
Resolved
CONDUCT TEST OF EMERGENCY BATTERIES AS REQUIRED BY 46CFR 109.211
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Electrical
Issued 14 December 1989
Resolved
REMOTE MUD PIT LOSS OF VENTILATION ALARM TO MANNED LOCATION(IE) DRILLERS CONSOLE OR BALLEST CONTROL ROOM. SCR ROOMNOT MANNED PLACES.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Deck/Cargo
Issued 14 December 1989
Resolved
MAKE REPAIRES TO THE PORT & STBD CRANE BOOMS CONDUCT FULL LOAD TEST ONCE REPAIRS ARE COMPLEATED IN THE PRESENCE OF A CG MARINE INSPECTOR OR AUTHURIZES AGENCY.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 18 November 1988
Resolved
PROVIDE PROPER GUARD ON OILY WATER SEPARATOR TANK SIGHT GLASS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Deck/Cargo
Issued 18 November 1988
Resolved
REPLACE FLEXIBLE HOSE ON DISCHARGE SIDE OF OILY WASTE PUMP.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
CONDUCT INTERNAL EXAMINATION OF DRILL FLOOR AIR RECEIVER AND TEST RELIEF VALVE.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Accommodation/Occupational Safety
Issued 18 November 1988
Resolved
REPLACE WASTED SANITARY WATER PRESSURE VESSELS (2) IN MACHINERY SPACE.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Deck/Cargo
Issued 18 November 1988
Resolved
TEST RIG SHUT-DOWN FROM TOOLPUSHER'S OFFICE.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Documentation
Issued 18 November 1988
Resolved
PROVIDE LAUNCHING PLACARDS FOR ALL LIFEBOATS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Deck/Cargo
Issued 18 November 1988
Resolved
CONDUCT QUADRENNIAL CRANE INSPECTION ON ALL CRANES.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
PROVIDE NEW RADIO BATTERIES FOR ALL LIFEBOATS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
MAKE PERMANENT REPAIRS TO NO.2 LIFE CAPSULE IN UPPER HULL NEXT TO STARBOARDHATCH. REPAIRS TO BE MADE BY APPROVED LIFEBOAT COMPANY.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
MAKE PERMANENT REPAIRS BY APPROVED LIFEBOAT COMPANY TO HOLES IN AFTER DOOR OF LIFEBOAT NO. 1.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Lifesaving
Issued 18 November 1988
Resolved
HAVE APPROVED LIFEBOAT COMPANY REPLACE OR REPAIR ALL LOOSE HATCH GASKETS ONALL LIFEBOATS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Deck/Cargo
Issued 18 November 1988
Resolved
TEST DRILLERS CONSOLE PURGE AIR ALARM.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
TEST RELIEF VALVES FOR SUBSTRUCTURE AFT AIR RECEIVERS 1,2,3,4, & 9 TOP ROW AND 1-6, & 8 BOTTOM ROW (NUMBERING FROM AFT).
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
CONDUCT INTERNAL EXAMINATION OF SUBSTRUCTURE AFT AIR RECEIVERS 1,2,3,4, & 9TOP ROW AND 1-6, & 8 BOTTOM ROW (NUMBERING FROM AFT).
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Construction/Loadline
Issued 12 February 1988
Resolved
PROVIDE THIS OFFICE WITH A COPY OF THE ABS REPORT AS EVIDENCE OF REPAIR COMPLETION ON THE NUMBER 9 STARBOARD BALLAST TANK.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Construction/Loadline
Issued 21 October 1987
Resolved
REPAIR THE PORT PUMP ROOM LOW SEA SUCTION VALVE AS SOON AS POSSIBLE BUT NOT LATER THAN 18NOV87
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Construction/Loadline
Issued 28 April 1987
Resolved
SUBMIT COPY OF GAUGING REPORT TO [name withheld].
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Engineering
Issued 30 October 1986
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE TENSIONER BOTTLE AND THE AIR RECEIVER LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Documentation
Issued 30 October 1986
Resolved
PROVIDE LETTER OF 10 JUL 1981 APPROVING THE OPERATIONS MANUAL.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986
Resolved
PROVIDE RESULTS OF ANALYSIS TO THIS OFFICE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Construction/Loadline
Issued 15 October 1986
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED STARBOARD FORWARD LONGITUDNAL DIAGONAL BRACE AT THE 43 FOOT DRAFT MARK. THIS ITEM TO BE COMPLETED AT NEXT SCHEDULED DRYDOCKING OR PRIOR TO NEXT ABS SPECIAL SURVEY.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 25 November 1985
Resolved
PROVIDE NON-CONDUCTIVE GLOVES FOR BOTH FIREMAN'S OUTFITS NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Lifesaving
Issued 25 November 1985
Resolved
REFILL THE EMPTY AIR BOTTLE IN STERN #1 LIFEBOAT NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Construction/Loadline
Issued 25 November 1985
Resolved
REPAIR THE INOPERATIVE VISUAL BILGE ALARM FOR THE PORT BALLAST PUMP ROOM NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Construction/Loadline
Issued 25 November 1985
Resolved
REPAIR THE INOPERATIVE PORT FORWARD DRAFT INDICATOR LOCATED IN THE BALLAST CONTROL NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Unknown
Issued 25 November 1985
Resolved
REPAIR ALL OBSTRUCTION LIGHTS; BROKEN LENS, INOPERATIVE, LOSE LAMP CHANGER,NOT FOCUSED PER COLREGS
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Engineering
Issued 25 November 1985
Resolved
REPAIR OR REPLACE THE FOLLOWING ITEMS FOR THE CRANES STBD: SERVICE CO2 BOTTLE, FREE UP CABLE ROLLER BASE SECTION OF BOOM; STERN:MAKE OPERABLE THE BOOM ANGLE INDICATOR & UPPER LIMIT STOP WHIP HOIST, PROVIDE AUDIBLE. WARNING DEVICE 46 CFR 107.259
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Lifesaving
Issued 25 November 1985
Resolved
REPLACE MILK #2 CAPSULE NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Accommodation/Occupational Safety
Issued 25 November 1985
Resolved
REPAIR RAILING, VERTICAL SECTION, STARBOARD CRANE PLATFORM NVC 4-78
Condition: Unknown
Due 25 November 1985
Resolved 25 November 1985
Unknown
Issued 23 October 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL ZAPATA SARATOGA DN575526
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984
Construction/Loadline
Issued 23 October 1984
Resolved
AT NEXT DRYDOCKING MAKE PERMANENT REPAIRS TO THE DAMAGED SIDE SHELL PLATINGINWAY OF THE NO 6 CAISSON, BALLAST TANK NO 14 STARBOARD BETWEEN THE RING GIRDER AT THE 35 FT LEVEL AND THE RING GIRDER AT 40 FT LEVEL. DAMAGE AREA MEASURES 2 FT X 5 FT.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984
Unknown
Issued 22 October 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE MODU ZAPATA SARATOGA DN 575526.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984
Construction/Loadline
Issued 22 October 1984
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED STARBOARD FORWARD LONGITUDNAL DIAGO- NAL BRACE AT THE 43 FOOT DRAFT MARK. ALL WELDING IS TO BE COMPLETED USING APPROVED PROCEDURES AND QUALIFIED WELDERS.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984
Unknown
Issued 17 November 1983
Resolved
POST RATED LIFTING CAPACITY ON THE FORK LIFT 46 CFR 109.533.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Fire Fighting
Issued 17 November 1983
Resolved
POST INSTRUCTIONS FOR OPERATION OF PAINT LOCKER CO2 SYSTEM 46CFR108.631.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Electrical
Issued 17 November 1983
Resolved
MAKE ALARMS AND RAIN TIGHT JUNCTION BOX ON MUD MONITOR GAS DETECTOR EQUIPMENT SUITABLE FOR INSTALLATION IN A CLASSIFIED LOCATION 46CFR111.92.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Accommodation/Occupational Safety
Issued 17 November 1983
Resolved
RENEW WASTED RELIEF VALVE PIPE NIPPLES ON ALL P-TANKS.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Construction/Loadline
Issued 17 November 1983
Resolved
SEAL THE CABLE PENETRATION THROUGH THE STARBOARD MUD PIT BULKHEAD. 46 CFR 108.185
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Unknown
Issued 17 November 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL ZAPATA SARATOGA, DN575526
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Electrical
Issued 17 November 1983
Resolved
CONNECT NUMBER 10 AWG AND SMALLER WIRES AT TERMINALS WITH TERMINAL PLATES HAVING UNTURNED LUGS 46 CFR 111.60-25(M).
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Deck/Cargo
Issued 17 November 1983
Resolved
INSTALL SUITABLE PROTECTION OVER SIGHT GLASS ON LUBE OIL STORAGE TANK 46 CFR 56.50-90.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Unknown
Issued 17 November 1983
Resolved
REPAIR FORKLIFT MOVEMENT ALARM 46 CFR 108.613(D)(1).
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Accommodation/Occupational Safety
Issued 17 November 1983
Resolved
MAKE PAINT LOCKER VENTILATION SYSTEM FIRE DAMPER OPERABLE FROM A LOCATION NEAR THE CO2 DISCHARGE PULL STATION 46 CFR 108.455.
Condition: Unknown
Due 31 December 1983
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 18 February 1983
Resolved
MAKE PERMANENT REPAIRS TO ALL DAMAGED AREAS RESULTING FROM COLLISION OF 13FEB83. SUBMIT PROPOSAL FOR REPAIRS TO [name withheld] PRIOR TO START OF
Condition: Unknown
Due 18 February 1983
Resolved 18 February 1983
Unknown
Issued 18 February 1983
Resolved
(REQUIREMENT 1A CONTINUED) REPAIRS.
Condition: Unknown
Due 18 February 1983
Resolved 18 February 1983
Unknown
Issued 18 February 1983
Resolved
THE FOLLOWING DEFICENCY PERTAINS TO THE VESSEL ZAPATA SARATOGA, DN575526.
Condition: Unknown
Due 18 February 1983
Resolved 18 February 1983
Deck/Cargo
Issued 22 November 1982
Resolved
INSTALL ASME RELIEF VALVES WITH HAND RELIEVING GEAR ON FOUR ANCHOR WINCH AIR RECEIVERS.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Construction/Loadline
Issued 22 November 1982
Resolved
INTERNALLY EXAMINE OR HYDRO TEST AIR RECEIVER ON DRILL FLOOR AND PROVE OPERATION OF RELIEF VALVE NO LATER THAN NEXT RIG MOVE.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
PROVIDE POLLUTION PLACARDS IN PORT AND STARBOARD PUMP ROOMS.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
PROVIDE POLLUTION CONTAINMENT AROUND MAIN DIESEL OIL TANK VENTS AND PORT AND STARBOARD REFUELING STATIONS, MAIN DECK.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Fire Fighting
Issued 22 November 1982
Resolved
SUBMIT FOAM SAMPLE FOR ANALYSIS AND PROVIDE COPY TO [name withheld] INSTRUCTIONS FOR THE FOAM SYSTEM.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Construction/Loadline
Issued 22 November 1982
Resolved
IN THE MUD PIT AREA REPAIR CORRODED SECTIONS OF MUD PIT DOORS AND ADJUST DOORS SO THEY CLOSE.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
ON THE DRILL FLOOR PROVIDE EXPLOSION PROOF JUNCTION BOXES WITH EYS SEALS INSIDE RUCKER CONTROL CONSOLE OR PROPERLY PURGE THIS CONSOLE AND REMOVE OR
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
(REQUIREMENT D9, CONTINUED) REPLACE NON-EXPLOSION PROOF HORN LOCATED NEAR CRAYTON MONITORS.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
IN THE SHALE SHAKER AREA PROVIDE CHICKO FOR EYS SEAL TO JUNCTION BOX BENEATH STARBOARD SHAKER AND REPAIR GENERAL ALARM HORN.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Lifesaving
Issued 22 November 1982
Resolved
PROVIDE THE FOLLOWING FOR CAPSULES/BOAT: A. #1 CAPSULE - ONE HATCHET, AND ONE JACK KNIFE. B. #2 CAPSULE - ONE JACK KNIFE. C. #1 BOAT - ONE JACK KNIFE
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Lifesaving
Issued 22 November 1982
Resolved
(REQUIREMENT D1, CONTINUED) ONE BUCKET, ONE TABLE OF LIFESAVING SIGNALS, ONE MAINTENANCE MANUAL AND ONE AIR BOTTLE.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Unknown
Issued 22 November 1982
Resolved
PROVIDE LUBE OIL DAY TANK WITH NON-FLAMMABLE SIGHT GLASSES WITH MECHANICAL PROTECTION.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Construction/Loadline
Issued 22 November 1982
Resolved
PROVIDE EVIDENCE OF COMPLETION OF PERMANENT REPAIRS TO INSERT IN NUMBER 4 CAISSON AT 42 FOOT LEVEL.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Accommodation/Occupational Safety
Issued 22 November 1982
Resolved
(REQUIREMENT E11, CONTINUED) HAVE BEEN SERVICED AND TESTED AT FULL RELIEF PRESSURE BY AUTHORIZED MANUFACTURERS REPRESENTATIVE.
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982
Accommodation/Occupational Safety
Issued 22 November 1982
Resolved
TEST RELIEF VALVES ON 23 TENSIONER BOTTLES IN RUCKER AIR SYSTEM IN PRESENCE OF CG MARINE INSPECTOR OR PROVIDE DOCUMENTATION THAT ALL RELIEF VALVES
Condition: Unknown
Due 22 November 1982
Resolved 22 November 1982