Records from 1982 to 2005. Most recent: inspection, 6 April 2005.
Inspection history · 63
6 April 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327641
19 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2277578
26 October 2004
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2228378
22 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2190320
30 June 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2116211
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971013
1 October 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1961466
14 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1846232
7 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1838080
26 February 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1753680
5 July 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1647095
17 May 2002
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1616537
13 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067890
21 May 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064928
4 October 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454827
19 May 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805882
16 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459422
13 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 82433
4 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783943
23 May 1997
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364286
16 May 1997
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392668
21 April 1997
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404285
9 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758604
2 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 195257
2 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357487
8 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 654615
19 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878292
22 April 1995
Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 868302
8 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 654612
7 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 15353
7 February 1995
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 838353
2 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467856
17 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 153201
4 May 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395925
2 March 1992
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 961745
5 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952631
11 April 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 930678
5 March 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906247
16 August 1990
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904503
27 March 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 917985
21 February 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901595
21 February 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 905069
6 July 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338128
14 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208264
13 June 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1034648
12 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203442
8 June 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199519
21 March 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 455127
13 February 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 452021
20 January 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 328021
6 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 529190
5 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481347
3 January 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041150
19 December 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 454593
2 December 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 480856
7 November 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 890398
26 October 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 889716
20 October 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197052
20 October 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197062
23 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893509
30 March 1988
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013449
21 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314638
17 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298135
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 July 2003
Resolved
Make repairs to SSB.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Fuel Oil Service System › Filter
Issued 7 July 2003
Resolved
Provide metallic plug and bowl for port generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 7 July 2003
Resolved
Renew 2 fuel hoses on starboard generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2003
Resolved
Provide eyewash bottle for enginerrom eye wash station.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Bilge Water Management System › Manifold
Issued 7 July 2003
Resolved
Label all valves on bilge manifold.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 July 2003
Resolved
Calibrate rudder angle indicators.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Stability › Watertight Integrity
Issued 7 July 2003
Resolved
Renew gasket on engineroom/rudder room watertight door. LEGACY COMPONENT DESC: Watertight door gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 July 2003
Resolved
Properly secure shark jaw batteries located on cat walk in aft engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2003
No resolution recorded
Provide new fire safety control plan for approval.
Action required: 705 - Other - as specified
Due 7 August 2003 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 May 2002
Resolved
Rudder angle indicator in aft steering room disconnected.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 July 2002
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 May 2002
Resolved
Make permanent repairs to small hole, stbd side aft steering gear room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2002
Deck/Cargo › Mooring/Anchoring
Issued 17 May 2002
Resolved
Repair leak on Shark Jaw Box. LEGACY COMPONENT DESC: Shark Jaw Box
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2002
Construction/Loadline
Issued 16 June 1998
Resolved
EFFECT PERMANENT REPAIRS TO LEAK IN PORT WRAP AROUND HULL TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO SAILING.
Condition: Unknown
Due 16 June 1998
Resolved 29 June 1998
Fire Fighting
Issued 23 May 1997
Resolved
PROVIDE FIRE SAFETY PLAN FOR REVIEW AND APPROVAL TO OCMI.
Condition: Unknown
Due 30 June 1997
Resolved 5 September 1997
Engineering
Issued 23 May 1997
Resolved
PROVIDE AUTOMATION TEST PROCEDURE FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 30 June 1997
Resolved 5 September 1997
Electrical
Issued 22 April 1995
Resolved
LABEL ALL CIRCUIT BOXES AND COLOR INSIDE OF PANEL DOOR TO INDICATE DOOR IS OPEN, PRIOR TO 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 22 April 1995
Resolved
DEMONSTRATE PROPER OPERATION AND MARKING OF "GENERAL ALARM LIGHT" TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Construction/Loadline
Issued 22 April 1995
Resolved
DEMONSTRATE PROPER CLOSURE AND FIT OF ALL WATER-TIGHT DOORS TO THE SATISFACTION OF ATTENDING INSPECTOR NLT 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, REPLACE #5 FIRE EXTINGUISHER.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Documentation
Issued 22 April 1995
Resolved
SUBMIT OIL POLLUTION PREVENTION EMERGENCY PLAN(SOPPEP) TO G-MEP AND PROVIDEAPPROVED PLAN ON BOARD NOTIFY LOCAL [name withheld] AS APPROVAL FOR SOPEP IS RECEIVED.
Condition: Unknown
Due 22 April 1995
Resolved 22 April 1995
Documentation
Issued 22 April 1995
Resolved
PROVIDE SHIP'S LOGBOOK FOR INSPECTION AND PROVIDE PROOF THAT THE DRILLS , INSPECTIONS, AND ACTIONS REQUIRED TO BE LOGGED ARE BEING CARRIED OUT PER 46CFR 97.35-5.
Condition: Unknown
Due 22 April 1995
Resolved 22 April 1995
Construction/Loadline
Issued 22 April 1995
Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR TO THE SATISFACTION OFLOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995
Resolved
CORRECTIONS TO FIRE CONTROL SAFETY PLAN TO INDICATE LOCATION OF ALL FIRE STATIONS AND LOCATION OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, DEMONSTRATE AND PERFORM PRESSURE TEST CHARGING OF FIRE HOSES AND PERFORM SATISFACTORY "FIRE DRILL" TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, MAKE SATISFACTORY PERMANENT REPAIRS TO BREAK/LEAK IN FIRE MAIN.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 22 April 1995
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, PROVIDE SUITABLE USCG APPROVED JACOB'S LADDER/EMBARKATION LADDER.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Electrical
Issued 22 April 1995
Resolved
REPLACE ALL GLOBES AND GUARDS MISSING ON LIGHTS IN ENGINEERING SPACES TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Electrical
Issued 22 April 1995
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY SHUT DOWN ON SHIP SERVICE GENERATORS TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Unknown
Issued 22 April 1995
Resolved
DEMONSTRATE THE LABELING OF ALL PUMPS AND VALVES THROUGHOUT ENGINEERING SPACES TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Construction/Loadline
Issued 7 February 1995
Resolved
VESSEL SUSTAINED A 2" FRACTURE TO STARBOARD SIDESHELL MIDSHIPS ADJACENT TO STARBOARD MIDSHIPS FUEL TANK. ISSUED CG-835 TO EFFECT TEMPORARY REPAIRS. TEMPORARY REPAIRS CONSIST OF WELDING 20"x20" DOUBLER PLATE OVER DAMAGED_x001C_ AREA AND PRESSURE TESTING. PERMANENT REPAIRS TO BE EFFECTED UPON DRYDOCK.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Engineering
Issued 21 February 1990
Resolved
INSTALL A FUEL OIL DAY TANK HIGH LEVEL ALARM AS REQUIRED BY NVIC 1-78 PARA 2(H)(6).
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Navigation
Issued 21 February 1990
Resolved
INSTALL A COMMUNICATION SYSTEM AS REQUIRED BY NVIC 1-78 PARA 1(D)
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Engineering
Issued 20 October 1988
Resolved
PROVIDE USCG APPROVED AUTOMATION PROCEDURES IN ACCORDANCE WITH NVIC 1-78
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Lifesaving
Issued 30 March 1988
Resolved
SUBMIT REVISED VESSEL FIR AND SAFETY PLAN FOR APPROVAL, INDICATING BERTHINGFOR SIXTEEN PERSONS. (46 CFR 97.36-1)
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Documentation
Issued 30 March 1988
Resolved
PROVICE EVIDENCE OF COMPLIANCE WITH 33 CFR 130 (CERTIFICATE OF FINANCIAL RESPONSIBILITY) PRIOR TO THE VESSEL ENTERING INTO SERVICE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Documentation
Issued 30 March 1988
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH 46 CFR 67 (VESSEL DOCUMENTATION) PRIOR TO THE VESSEL ENTERING INTO SERVICE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988