MAURY USCG vessel records Sign in
← All vessels

TITAN TIDE

TITAN TIDE is a 1975 offshore supply vessel. The Coast Guard has recorded 63 inspections since 1982, most recently in April 2005, along with 36 deficiencies — 1 with no resolution recorded — and 4 casualty investigations between 2002 and 2005.

Records from 1982 to 2005. Most recent: inspection, 6 April 2005.

Built
1975
Last inspected
6 April 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7427673 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB3674
Flag
UNITED STATES
366188000, 366761220 (licence lapsed)
Maury page id
psix-48553

Inspections, by type

…with no type recorded27
…past their stated due date1
Years with a record 20 calendar years (1982–2005)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it462 - Regulatory (Subpart C or D), Gross Ton
1200 - Convention (Subpart B), Gross Ton
314 - Regulatory (Subpart C or D), Net Ton
360 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3674MMSI 366188000 · cancelled · compulsorily equipped · granted 17 April 2003, cancelled 6 February 2013
WUV4165MMSI 366761220 · expired · compulsorily equipped · granted 1 February 1999, cancelled 10 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HERCULES 2500 Mobile Offshore Drilling Unit · MISLE 52699 · 19 January 2005 · activity 2277578OCEAN SARATOGA Mobile Offshore Drilling Unit · MISLE 48838 · 22 August 2004 · activity 2190320SMIT CURACAO Towing Vessel · MISLE 274868 · 13 January 1998 · activity 82433MR. HARLAN, JR. Offshore Supply Vessel · MISLE 50447 · 17 December 1993 · activity 153201

Inspection history · 63

6 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327641
19 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2277578
26 October 2004 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2228378
22 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2190320
30 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2116211
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971013
1 October 2003 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1961466
14 July 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1846232
7 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1838080
26 February 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1753680
5 July 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1647095
17 May 2002 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1616537
13 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067890
21 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064928
4 October 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454827
19 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805882
16 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459422
13 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 82433
4 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783943
23 May 1997 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364286
16 May 1997 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392668
21 April 1997 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404285
9 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758604
2 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 195257
2 February 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357487
8 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 654615
19 July 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878292
22 April 1995 Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 868302
8 February 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 654612
7 February 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 15353
7 February 1995 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 838353
2 February 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467856
17 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 153201
4 May 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395925
2 March 1992 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 961745
5 February 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952631
11 April 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 930678
5 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906247
16 August 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904503
27 March 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 917985
21 February 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901595
21 February 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 905069
6 July 1989 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338128
14 June 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208264
13 June 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1034648
12 June 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203442
8 June 1989 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199519
21 March 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 455127
13 February 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 452021
20 January 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 328021
6 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 529190
5 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481347
3 January 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041150
19 December 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 454593
2 December 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 480856
7 November 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 890398
26 October 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 889716
20 October 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197052
20 October 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197062
23 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893509
30 March 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013449
21 October 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314638
17 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298135

Deficiency record · 36

Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 July 2003 Resolved
Make repairs to SSB.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Fuel Oil Service System › Filter
Issued 7 July 2003 Resolved
Provide metallic plug and bowl for port generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 7 July 2003 Resolved
Renew 2 fuel hoses on starboard generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2003 Resolved
Provide eyewash bottle for enginerrom eye wash station.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Bilge Water Management System › Manifold
Issued 7 July 2003 Resolved
Label all valves on bilge manifold.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 July 2003 Resolved
Calibrate rudder angle indicators.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Stability › Watertight Integrity
Issued 7 July 2003 Resolved
Renew gasket on engineroom/rudder room watertight door. LEGACY COMPONENT DESC: Watertight door gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 July 2003 Resolved
Properly secure shark jaw batteries located on cat walk in aft engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2003 No resolution recorded
Provide new fire safety control plan for approval.
Action required: 705 - Other - as specified
Due 7 August 2003 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 May 2002 Resolved
Rudder angle indicator in aft steering room disconnected.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 July 2002
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 May 2002 Resolved
Make permanent repairs to small hole, stbd side aft steering gear room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2002
Deck/Cargo › Mooring/Anchoring
Issued 17 May 2002 Resolved
Repair leak on Shark Jaw Box. LEGACY COMPONENT DESC: Shark Jaw Box
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 July 2002
Construction/Loadline
Issued 16 June 1998 Resolved
EFFECT PERMANENT REPAIRS TO LEAK IN PORT WRAP AROUND HULL TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO SAILING.
Condition: Unknown
Due 16 June 1998
Resolved 29 June 1998
Fire Fighting
Issued 23 May 1997 Resolved
PROVIDE FIRE SAFETY PLAN FOR REVIEW AND APPROVAL TO OCMI.
Condition: Unknown
Due 30 June 1997
Resolved 5 September 1997
Engineering
Issued 23 May 1997 Resolved
PROVIDE AUTOMATION TEST PROCEDURE FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 30 June 1997
Resolved 5 September 1997
Electrical
Issued 22 April 1995 Resolved
LABEL ALL CIRCUIT BOXES AND COLOR INSIDE OF PANEL DOOR TO INDICATE DOOR IS OPEN, PRIOR TO 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 22 April 1995 Resolved
DEMONSTRATE PROPER OPERATION AND MARKING OF "GENERAL ALARM LIGHT" TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Construction/Loadline
Issued 22 April 1995 Resolved
DEMONSTRATE PROPER CLOSURE AND FIT OF ALL WATER-TIGHT DOORS TO THE SATISFACTION OF ATTENDING INSPECTOR NLT 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995 Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, REPLACE #5 FIRE EXTINGUISHER.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Documentation
Issued 22 April 1995 Resolved
SUBMIT OIL POLLUTION PREVENTION EMERGENCY PLAN(SOPPEP) TO G-MEP AND PROVIDEAPPROVED PLAN ON BOARD NOTIFY LOCAL [name withheld] AS APPROVAL FOR SOPEP IS RECEIVED.
Condition: Unknown
Due 22 April 1995
Resolved 22 April 1995
Documentation
Issued 22 April 1995 Resolved
PROVIDE SHIP'S LOGBOOK FOR INSPECTION AND PROVIDE PROOF THAT THE DRILLS , INSPECTIONS, AND ACTIONS REQUIRED TO BE LOGGED ARE BEING CARRIED OUT PER 46CFR 97.35-5.
Condition: Unknown
Due 22 April 1995
Resolved 22 April 1995
Construction/Loadline
Issued 22 April 1995 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR TO THE SATISFACTION OFLOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995 Resolved
CORRECTIONS TO FIRE CONTROL SAFETY PLAN TO INDICATE LOCATION OF ALL FIRE STATIONS AND LOCATION OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995 Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, DEMONSTRATE AND PERFORM PRESSURE TEST CHARGING OF FIRE HOSES AND PERFORM SATISFACTORY "FIRE DRILL" TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Fire Fighting
Issued 22 April 1995 Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, MAKE SATISFACTORY PERMANENT REPAIRS TO BREAK/LEAK IN FIRE MAIN.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Lifesaving
Issued 22 April 1995 Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, PROVIDE SUITABLE USCG APPROVED JACOB'S LADDER/EMBARKATION LADDER.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Electrical
Issued 22 April 1995 Resolved
REPLACE ALL GLOBES AND GUARDS MISSING ON LIGHTS IN ENGINEERING SPACES TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Electrical
Issued 22 April 1995 Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY SHUT DOWN ON SHIP SERVICE GENERATORS TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Unknown
Issued 22 April 1995 Resolved
DEMONSTRATE THE LABELING OF ALL PUMPS AND VALVES THROUGHOUT ENGINEERING SPACES TO THE SATISFACTION OF LOCAL [name withheld] 21MAY95.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Construction/Loadline
Issued 7 February 1995 Resolved
VESSEL SUSTAINED A 2" FRACTURE TO STARBOARD SIDESHELL MIDSHIPS ADJACENT TO STARBOARD MIDSHIPS FUEL TANK. ISSUED CG-835 TO EFFECT TEMPORARY REPAIRS. TEMPORARY REPAIRS CONSIST OF WELDING 20"x20" DOUBLER PLATE OVER DAMAGED_x001C_ AREA AND PRESSURE TESTING. PERMANENT REPAIRS TO BE EFFECTED UPON DRYDOCK.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Engineering
Issued 21 February 1990 Resolved
INSTALL A FUEL OIL DAY TANK HIGH LEVEL ALARM AS REQUIRED BY NVIC 1-78 PARA 2(H)(6).
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Navigation
Issued 21 February 1990 Resolved
INSTALL A COMMUNICATION SYSTEM AS REQUIRED BY NVIC 1-78 PARA 1(D)
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Engineering
Issued 20 October 1988 Resolved
PROVIDE USCG APPROVED AUTOMATION PROCEDURES IN ACCORDANCE WITH NVIC 1-78
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Lifesaving
Issued 30 March 1988 Resolved
SUBMIT REVISED VESSEL FIR AND SAFETY PLAN FOR APPROVAL, INDICATING BERTHINGFOR SIXTEEN PERSONS. (46 CFR 97.36-1)
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Documentation
Issued 30 March 1988 Resolved
PROVICE EVIDENCE OF COMPLIANCE WITH 33 CFR 130 (CERTIFICATE OF FINANCIAL RESPONSIBILITY) PRIOR TO THE VESSEL ENTERING INTO SERVICE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Documentation
Issued 30 March 1988 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH 46 CFR 67 (VESSEL DOCUMENTATION) PRIOR TO THE VESSEL ENTERING INTO SERVICE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988

Casualty record · 4

5 July 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1647095
26 February 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1753680
22 August 2004Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2190320
19 January 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2277578
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ENSCO TITAN (2002–2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.