Records from 1981 to 2019. Most recent: inspection, 15 November 2019.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 74
15 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6917142
22 August 2013
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4758017
18 July 2012
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4382933
21 May 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4400534
7 July 2011
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4072962
24 May 2010
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3794412
2 March 2010
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3689844
29 January 2010
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3672187
20 July 2009
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3540599
29 October 2008
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3353725
25 July 2008
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3278506
4 April 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3177365
20 February 2007
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2874457
10 January 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2864672
27 December 2006
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2847198
12 December 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2838854
26 October 2006
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2808700
14 October 2006
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2801087
27 January 2006
Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2574731
27 January 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2589911
13 January 2005
Periodic Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2287803
3 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2026707
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1986886
4 December 2003
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1959054
31 March 2003
Hull Examination · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1742265
20 December 2002
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1721053
18 October 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1075834
4 October 2001
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426676
26 January 2001
Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1056767
8 January 2001
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1057493
6 January 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 22473
31 October 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823008
14 February 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1049111
14 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 810105
14 October 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399201
18 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 776751
5 March 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 135046
5 March 1999
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 801008
29 October 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 803305
1 October 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 801630
22 September 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402711
5 February 1998
Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1383766
3 November 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1110918
27 October 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406202
14 November 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453287
15 September 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 106614
2 November 1995
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1181986
9 November 1994
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860592
9 November 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 848353
27 September 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 454767
28 January 1993
COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1139301
26 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 67536
13 December 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260832
15 November 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932200
4 April 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 488523
25 January 1991
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1231805
25 January 1991
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1234705
21 November 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1222142
15 October 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 453525
13 February 1990
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 921984
19 October 1989
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1204591
10 November 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895572
19 February 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 483165
28 October 1987
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1019137
15 July 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 467446
19 March 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 539266
9 December 1986
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1331955
31 October 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991409
8 August 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 476206
17 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982703
27 November 1984
Type not recorded
No type recorded · MSO CINCINNATI · Activity 540652
6 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977340
23 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274764
1 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967446
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2012
Resolved
Barge sustained a hole to the Portside bow corner...O/O determined to place a 40" x 60" insert.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 July 2012
Resolution: Examined final repair and witnessed air test - All SAT. Discrepancy cleared.
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2012
Resolved
Barge developed an approximate 6" fracture to the bilge knuckle IWO of the #2 starboard side wing void. O/O to repair with a 32" x 39" insert.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 July 2012
Resolution: Examined final repair and witnessed air test - All SAT. Discrepancy cleared.
Construction/Loadline › Hull › Double Hull
Issued 18 July 2012
Resolved
Barge developed an approximate 6" hairline fracture to the starboard side corner bow of the transverse lap plate weld. O/O to repair by gouge and fillet weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 July 2012
Resolution: Exained final repair and witnessed air test - All SAT. Discrepancy cleared.
Engineering › Steam Boiler (auxiliary/waste heat) › Uptake
Issued 7 July 2011
Resolved
Renew exhaust stack of thermal fluid heater due to wastage.
Action required: 705 - Other - as specified
Due 7 August 2011
Resolved 8 July 2011
Resolution: Replaced stack.
Electrical › Lighting (service) › Conductor
Issued 7 July 2011
Resolved
Repair or remove damaged deck floodlight and enclose exposed wiring.
Action required: 705 - Other - as specified
Due 7 August 2011
Resolved 8 July 2011
Resolution: Capped junction box.
Construction/Loadline › Hull › Bottom Plating
Issued 29 January 2010
Resolved
PINHOLE IN #4 PORT WING TANK, WHERE KNUCKLE & BOTTOM PLATE MEET IN WELD SEAM, 15' AFT OF FWD BULKHEAD. INSTALLED EPOXY PATCH.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 11 March 2010
Resolution: Area where pinhole leak encompasses the new 41''x 2'' section of bottom plate. All sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 April 2008
Resolved
Vessel issued 835 . Vessel is in route from Port Arthur. Vessel required to head to Channel View South West ship yard to counduct gas freeing and ISE, COI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 30 July 2008
Resolution: Completed ISE and COI
Stability › Unintentional Flooding › General
Issued 15 October 2006
Resolved
#4 wing void, port side: 1/2" crack approx. 12' forward from aft bulkhead in the bottom of bilge knuckle.
Action required: 705 - Other - as specified
Resolved 25 October 2006
Resolution: MSU Chicago witnessed temporary repair; issued PTP; removed COI (See activity 2808700).
Construction/Loadline
Issued 10 February 2003
Resolved
Provide midship section modulus calculations as per 46CFR32.59-1(c). These calculations must apply current rulea of the American Bureau of Shipping as per 46CFR32.59-1 (a). The calculations should not apply the 1971 ABS Rules as shown on the engineering analysis prepared on Dec 18, 2002.
Action required: 705 - Other - as specified
Resolved 4 April 2003
Resolution: See letter from [name withheld] scanned to file
Construction/Loadline
Issued 10 February 2003
Resolved
Propose structural repairs and/or modifications that will bring vsl up to the required strength standards as per 46 CFR 31.10-21a (d) (2) (ii). The vessel does not meet the required plate thickness described in 46 CFR 32.59-1 (e) (3).
Action required: 705 - Other - as specified
Resolved 4 April 2003
Resolution: See letter from [name withheld] scanned to file
Deck/Cargo › Cargo Heating
Issued 20 December 2002
Resolved
Prior to loading next heated cargo, but no later than 28 January 2003, conduct operational test of vessels Thermal Fluid Heater alarms and shutdowns in the presence of a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Thermal Fluid Heater
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2003
Resolved 4 April 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 December 2002
Resolved
Prior to loading next cargo, prove proper operation of port side cargo pump, emergency shut-down. LEGACY COMPONENT DESC: Cargo Pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 December 2002
Resolved
Prior to loading next cargo, conduct hydrostatic tests on vessels cargo piping. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2003
Deck/Cargo
Issued 4 October 2001
Resolved
OWNERS REP DIDN'T FEEL COMFORTABLE CONDUCTING STANDARD TESTS FOR THERMAL FLUID HEATER. TEST TO BE CONDUCTED IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Deck/Cargo
Issued 4 October 2001
Resolved
DEMONSTRATE CLEANLINESS OF ALL PRESSURE RELIEF VALVE SEATS TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Deck/Cargo
Issued 4 October 2001
Resolved
CORRECT STICKING ON NUMBER 12 HIGH LEVEL INDICATOR PRIOR TO LOADING CARGO IN THE TANK.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Construction/Loadline
Issued 8 January 2001
Resolved
Determine cause of flooding into #5 void prior to loading cargo.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Construction/Loadline
Issued 8 January 2001
Resolved
Monitor #5 void for leakage every hour. Dewater as necessary.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Deck/Cargo
Issued 31 October 2000
Resolved
INSTALL VALVE POSITION INDICATORS ON ALL CARGO TANK PIPING NO LATER THAN NEXT CARGO TANK INTERNAL EXAM.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 14 November 1999
Resolved
Install rising stick indicators for cargo tanks 11 & 12 in a location to bevisible to tankerman.
Condition: Unknown
Due 14 November 1999
Resolved 14 November 1999
Deck/Cargo
Issued 14 October 1999
Resolved
Install rising stick indicators for cargo tanks 11 and 12 in a location to be visible to tankerman.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Construction/Loadline
Issued 5 March 1999
Resolved
AFTER OFFLOADING AND PRIOR TO LOADING DETERMINE LOCATION OF LEAK IN THE BOWVOID AND MAKE PERMANANT REPAIRS TO LEAK, POSSIBLY NEAR DOCKING PINS.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 1 October 1998
Resolved
Prove proper operation of owner installed auxiliary alarms for thermal fluid heater.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Electrical
Issued 1 October 1998
Resolved
Prove proper operation of frequency meter and amp meter at generator switchboard.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Electrical
Issued 1 October 1998
Resolved
Repair oil leak on generator prime mover.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Engineering
Issued 22 September 1998
Resolved
Prior to using thermal fluid heater, prove proper operation of audible and visual alarms to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Engineering
Issued 27 October 1997
Resolved
PROVE PROPER OPERATION OF ALARM ANNUNCIATOR PANEL FOR THERMAL FLUID HEATER.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Deck/Cargo
Issued 15 November 1991
Resolved
CONDUCT AND PROVIDE RECORD OF CARGO LINE ANNUAL HYDRO IN ACCORDANCE WITH 33CFR156.170 AND 155.820.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Fire Fighting
Issued 15 November 1991
Resolved
CONDUCT AND PROVIDE RECORD OF ANNUAL SERVICING AND TEST OF FIXED CO2 SYSTEMAT THERMAL FLUID HEATER IN ACCORDANCE WITH 46CFR31.10-19.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Engineering
Issued 15 November 1991
Resolved
EFFECT REPAIRS AS NECESSARY AND PROVE OPERATION OF THERMAL FLUID HEATER IN ACCORDANCE WITH 46CFR31.10-17.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991