Records from 1999 to 2017. Most recent: inspection, 21 August 2017.
Documentation record
Registered dimensions (L × B × D)224.0 ft × 56.0 ft × 18.0 ft
Registered tonnagegross 1,809 / net 555
ITC dimensions (L × B × D)224.0 ft × 56.0 ft × 18.0 ft
ITC tonnagegross 1,809 / net 555
BuilderHALTER MARINE GROUP INC · MOSS POINT, MS, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it555 - Convention (Subpart B), Net Ton
1158 - Displacement, Ton
1809 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
21 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6247690
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6143433
7 August 2015
Annual Inspection · SIP Inspection/Audit · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5212530
22 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4962345
3 June 2014
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4878630
24 November 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3907171
14 September 2010
SIP Inspection/Audit
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3849725
14 July 2009
SIP Inspection/Audit · MTSA/ISPS Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3533463
10 October 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3342011
4 April 2008
SIP Initial Entry · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3177542
25 July 2007
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3015281
11 July 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2710791
26 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2692173
15 February 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2585563
21 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2523389
13 July 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2425307
20 December 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2262644
14 July 2004
Cargo Tank Internal · Re-Inspection · MTSA/ISPS Verification · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2132926
30 June 2004
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2116585
19 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2047432
2 January 2004
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1973408
30 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1861400
13 August 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1660662
27 December 2001
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1602811
23 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070453
23 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1071182
26 July 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425168
26 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063227
25 September 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361717
9 February 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815525
3 August 1999
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460353
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 October 2008
Resolved
Adjust Auto Closing door for Class A machinery space iaw SOLAs requirements
Due 10 November 2008
Resolved 6 November 2008
Documentation › Markings/Placards › Warning Signs
Issued 10 October 2008
Resolved
Update and post Emergency steering procedures, Chief Engineer was unable to switch to emergency steering for about 30 minutes. Location of remote switch needs to specific.
Due 10 November 2008
Resolved 6 November 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 October 2008
Resolved
Show proper operation of OWS and have training for engineers on proper operation.
Due 10 November 2008
Resolved 6 November 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 10 October 2008
Resolved
Fire Alarm system showed trouble for Engine Room. Repair and show proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Lifesaving › Rescue Boat › Propulsion Engine
Issued 10 October 2008
Resolved
Show proper operation of Rescue Boat. Engine did not run properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Lifesaving › Launching Appliances › Davit
Issued 10 October 2008
Resolved
Manual Release cables were not operable. Show proper operation of davit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Personnel › Certificates/Documents/Licenses › Certificate, Radar Observer
Issued 11 July 2006
Resolved
Master onboard during inspection did not have radar endorsement, nor completion of radar obersver course.
Condition: Unknown
Due 11 July 2006
Resolved 11 July 2006
Resolution: Master was offgoing, relief master and mate both had proper endorsements authorizing service on vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 21 October 2005
Resolved
Provide required spare portable fire extinguishers IAW SOLAS regulations.
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 21 October 2005
Resolution: Spare fire extinguishers added to available inventory.
Communications › Radio Communications › EPIRB
Issued 30 July 2003
Resolved
Provide registration for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2003
Resolved 30 July 2003
Communications › Internal Communications System
Issued 30 July 2003
Resolved
Repair engine room sound powered phone. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2003
Resolved 30 July 2003
Communications › Visual Communication
Issued 30 July 2003
Resolved
Provide and post emergency instructions. LEGACY COMPONENT DESC: Emergency Instructions
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2003
Resolved 30 July 2003
Lifesaving › Lifebuoys
Issued 30 July 2003
Resolved
Properly arrange both port and starboard bridge wing smoke/buoys. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 2 January 2004
Lifesaving › Rescue Boat › Markings
Issued 13 August 2002
Resolved
RESCUE BOAT NOT PROPERLY STENCILED.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2002
Resolved 13 August 2002
Construction/Loadline › Markings
Issued 13 August 2002
Resolved
NO IDENTIFICATION MARKINGS ON DECK VENTS. LEGACY COMPONENT DESC: DECK VENTS
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2002
Resolved 13 August 2002
Lifesaving › Lifebuoys › Stowage
Issued 13 August 2002
Resolved
LIFERINGS ON FAINTAIL NOT ARRANGED FOR QUICK RELEASE.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2002
Resolved 13 August 2002
Documentation › Markings/Placards
Issued 13 August 2002
Resolved
PROPER IMO SYMBOLS NOT POSTED THROUGHOUT VESSEL IN ACCORDANCE WITH FIRE SAFETY PLAN. LEGACY COMPONENT DESC: IMO SYMBOLS
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 30 July 2003
Engineering
Issued 26 July 2001
Resolved
SUBMIT SOPEP FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 26 August 2001
Resolved 31 July 2001
Navigation
Issued 26 July 2001
Resolved
FIX HYDRAULIC LEAKS OFF OF THE PIPING TO THE STEERING IN RUDDER ROOM.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Engineering
Issued 26 July 2001
Resolved
INSTALL REMOTE FUEL SHUT OFF VALVES FOR THE EMERGENCY DIESEL GENERATOR DAY TANK OUTSIDE OF SPACE IAW 46 CFR 56.50-60 (d)(1).
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Fire Fighting
Issued 26 July 2001
Resolved
INSTALL FIRE EXTINGUISHING SYSTEM IN EMERGENCY DIESEL GENERATOR ROOM IAW SOLAS CH. II-2, REG. 7.2.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Construction/Loadline
Issued 25 September 2000
Resolved
Remove captive devices from all watertight doors.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Documentation
Issued 3 August 1999
Resolved
PROVIDE AN ABS APPROVED CARGO SECURING MANUAL IN ACCORDANCE W/ SOLAS 74 (AMENDED VI/5, PRIOR TO ENGAGING IN INTERNATIONAL VOYAGES.
Condition: Unknown
Due 3 September 1999
Resolved 6 December 1999
Documentation
Issued 3 August 1999
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION WITH CURRENT OWNER'S NAME PIORTO EMPLOYMENT OF VESSEL OFFSHORE.
Condition: Unknown
Due 3 September 1999
Resolved 6 December 1999