Records from 1982 to 2014. Most recent: inspection, 24 June 2014.
Inspection history · 114
24 June 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4898438
3 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4217876
30 September 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4166722
8 February 2011
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3995544
1 December 2010
COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3897368
24 November 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3907171
5 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3864000
10 February 2010
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3692573
7 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3429209
12 February 2009
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439411
4 June 2008
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3227379
28 February 2008
Annual Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158065
18 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132709
22 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2892768
23 January 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2861135
17 November 2005
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2524023
22 August 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2472278
16 August 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2466248
13 June 2005
Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2388866
19 January 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2277205
11 September 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2220710
1 February 2004
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2001756
23 November 2003
Periodic Inspection · Plan Review (Other than "T") · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1955599
8 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727739
14 January 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1478011
9 November 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1076814
21 March 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1060200
20 February 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058526
30 January 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 825096
21 October 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 204015
15 September 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1054498
28 August 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1053624
25 July 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 819996
19 June 2000
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1389128
4 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 139155
27 April 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 817361
3 April 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1047775
1 March 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1046981
10 January 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1388983
8 October 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1198782
1 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082303
26 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801615
17 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793959
8 January 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809488
8 January 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811440
8 December 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472142
14 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801253
29 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800228
23 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795058
9 July 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421529
8 June 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792189
10 December 1997
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1452352
17 November 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027315
29 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779712
27 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095543
3 March 1997
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1097786
17 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093272
10 December 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413083
31 January 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424177
14 September 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884405
14 August 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417817
21 June 1995
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447461
12 December 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1353676
21 November 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 869316
9 October 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 88416
10 May 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 156777
11 March 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1391971
8 March 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 173413
24 January 1994
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1162717
21 December 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1159877
21 December 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1160017
5 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 124867
23 June 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 843878
9 May 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 115166
30 April 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1149314
11 February 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1144025
17 December 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1138045
6 November 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951123
27 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265051
11 February 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267522
3 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58528
29 October 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250063
16 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940941
19 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919004
18 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231475
21 December 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 997288
13 June 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934929
25 May 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926198
31 January 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924195
28 December 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230159
11 July 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196042
29 December 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207716
30 October 1988
Examination of Repairs · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1201389
24 November 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319818
29 July 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320648
4 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005666
23 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005939
9 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008231
10 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013951
20 December 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001742
12 November 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021484
21 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311736
16 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304913
20 February 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310923
12 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995299
8 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285946
20 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282548
7 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280156
7 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283423
9 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971613
26 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277219
8 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276606
13 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277100
13 July 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271960
Construction/Loadline › Hull › Hull Plating
Issued 4 June 2008
Resolved
Complete Phase II within 90 days or prior to next rig move.
Action required: 705 - Other - as specified
Due 3 September 2008
Resolved 25 February 2009
Resolution: 12 June 09 - Rcvd ABS survey from Ensco supporting completion of Phase II exam.
Fire Fighting › Structural - Horizontal Zones › General
Issued 28 February 2008
Resolved
Install new structural fire protection insulation where old insulation was removed to install new lift supports on the OVHD of generator space.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 February 2008
Resolved
Provide means of closing all exterior vent covers on the exterior of the housing quarters.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 6 March 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 February 2008
Resolved
Provide vent closures for the dryer exhaust.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Electrical › Electric Generation Source (service) › Conductor
Issued 28 February 2008
Resolved
Provide metallic banding straps for the newly installed electrical cables leading to the smoke house A/C.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 February 2008
Resolved
Remove soft patch from lube oil storage tank and lube oil centrifuge discharge piping and properly repair.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 28 February 2008
Resolved
Prove proper operation of the purge alarm for the driller control console or provide documentation that the unit in intrinsically safe.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 6 March 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 February 2008
Resolved
Prove proper operation of the electric supply and exhaust vent louvers for the emergency generator space.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Lifesaving › Launching Appliances › Falls
Issued 28 February 2008
Resolved
Prove proper load test on the port and STBD life raft davits.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 3 March 2008
Electrical › Lighting (service) › Conductor
Issued 28 February 2008
Resolved
Prove proper synchronization of all obstruction lights.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 28 February 2008
Resolved
Prove two hour load test is being conducted monthly on the emergency generator.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Operations/Management › Drills/Instruction › Safety Orientation
Issued 28 February 2008
Resolved
Properly document all training requirements required by 46 CFR 109.213.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 3 March 2008
Lifesaving › Launching Appliances › Falls
Issued 28 February 2008
Resolved
Prove proper load test on #1 lifeboat after falls were renewed.
Action required: 705 - Other - as specified
Due 10 March 2008
Resolved 3 March 2008
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 January 2007
Resolved
One of three air bottles in Life boat one low, only 1250 psig, should be min 2500psig.
Condition: Improper/Lack of Maintenance
Due 7 February 2007
Resolved 23 January 2007
Deck/Cargo › Cargo Transfer (solid) › General
Issued 16 August 2005
Resolved
Replace cracked windows in aft port/stbd cranes.
Due 23 August 2005
Resolved 22 August 2005
Resolution: Damaged windows removed and replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 7 June 2005
Resolved
Complete Phase II ( Leg Can Inspection ) to the satisfaction of the attending ABS Surveyor or Coast Guard Inspector no later than 7 September 2005.
Due 7 September 2005
Resolved 7 September 2005
Resolution: Provided reports attesting to completion of phase II.
Documentation › Safety/Response Plans/Programs
Issued 23 November 2003
Resolved
Submit for final review units fire and safety plan to MSSO Brownsville, Texas after ABS final approval. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 1 February 2004
Documentation
Issued 19 June 2000
Resolved
COMPLETE BOTTOM PORTION OF SEILOID PRIOR TO 15AUG00 TO THE SATISFACTION OF THE OCMI AND BEFORE DEPARTURE FROM CORMS ZONE.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 19 June 2000
Resolved
REWELD LOWER CAP END OF SKIMMER TANK LOCATED WITHIN PRELOAD TANK NO. 38.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 19 June 2000
Resolved
REWELD DECK BOX GLAND ON REACH ROD ON PRELOAD TANK NO. 39.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 19 June 2000
Resolved
REMOVE DOUBLER PLATE ON TOP PLATE OF NO. 1 MUD PIT ROOM. RENEW/REPLACE PLATING AS REQUIRED TO CORRECT PITTING IN ADJACENT NO. 19 VOID.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 19 June 2000
Resolved
RENEW BILGE STRAINERS IN PRELOAD TANKS NO. 13, 19, 26, AND VOID AREA UNDER HALLIBURTON MACHINERY.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 19 June 2000
Resolved
DESCALE PRELOAD TANK NO. 38, LADDER, AND SUBWAY GRATING AS INDICATED BY ABSOUTSTANDING RECOMMENDATIONS/CONDITIONS OF CLASS ISSUED 19JUN00.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Accommodation/Occupational Safety
Issued 10 January 2000
Resolved
Secure safety netting on helo pad and secure juction box for light fixtures.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Electrical
Issued 10 January 2000
Resolved
Procure and install push buttons for motor controlers located on 480v PowerDistribution Board.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Electrical
Issued 10 January 2000
Resolved
Repair and prove proper operation of emergency light located in pump room.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Electrical
Issued 10 January 2000
Resolved
Repair broken electrical stand pipe next to top drive controller.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Lifesaving
Issued 10 January 2000
Resolved
Conduct fire and boat drill in presence of Coast Guard inspector.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Lifesaving
Issued 10 January 2000
Resolved
Install new exhaust pipe to stbd life boat. (existing pipe is split down the seam)
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Accommodation/Occupational Safety
Issued 10 January 2000
Resolved
Conduct hydrostatic test of air receiver located on drill floor and prove proper operation of relief valve. I.A.W. 46 CFR 61.10-5(b).
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Lifesaving
Issued 10 January 2000
Resolved
Conduct lifeboat release gear test under load of 1.1 times the total mass of the lifeboat when loaded with its full complement of persons and equipment I.A.W. 46 CFR 109.301(i)(5).
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Lifesaving
Issued 8 December 1998
Resolved
Prove proper operation of fire protection waterspray systems on lifeboats 1and 2._x001C_
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Documentation
Issued 8 December 1998
Resolved
Develop and implement rig instruction and training program that meets the intent of 46 CFR 109.213(g) for required instruction material and recordingof same per 109.213(h).
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Accommodation/Occupational Safety
Issued 8 December 1998
Resolved
Develop proper ventilation pressure differential between mud pit room (Class I Div 2) and adjacent mud pump room and sack room (both unclassifiedspaces). Pit room loss-of-ventilation alarm must indicate loss of relative negative pressure in mud pit room, not just loss of mechanical ventilation.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Construction/Loadline
Issued 29 September 1998
Resolved
COMPLETE REPAIRS AS REQUIRED BY ABS REPORT MC8960, LAST DATE OF VISIT 08SEP98, REPORT DATED 10SEP98.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Construction/Loadline
Issued 23 July 1998
Resolved
Complete outstanding recommendations noted on ABS survey report BT 5160.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 9 July 1998
Resolved
RENEW BILGE STRAINERS IN PRELOAD TANKS NO. 6, 12, 26, 38, AND 40.
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Construction/Loadline
Issued 9 July 1998
Resolved
GAUGE BOTTOM SHELL AND LONGITUDINAL STIFFENERS IN PRELOAD TANK NO.40, AS INDICATED BY ATTENDING ABS SURVEYOR.
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Electrical
Issued 10 December 1996
Resolved
REPAIR ELECTRICAL GROUND ON SHALE SHAKER MOTOR.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Unknown
Issued 10 December 1996
Resolved
CROP AND RENEW WASTED PIPING ON BILGE / EDUCTOR SYSTEM.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Accommodation/Occupational Safety
Issued 10 December 1996
Resolved
PLACE 100 PSI SAFETY RELIEF VALVES ON HOT WATER HEATERS.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996
Resolved
REPLACE 36 LIFE PRESERVERS. CREW LIMITED TO 49 TOTAL PERSONS ONBOARD UNTIL REPLACEMENTS ARRIVE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 10 December 1996
Resolved
INSTALL DOOR LATCHES IN ALL STAIR TOWER DOORS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 10 December 1996
Resolved
HAVE OUTDATED INFLATABLE LIFERAFT SERVICED. CREW LIMITED TO 61 TOTAL PERSONS ONBOARD UNTIL LIFERAFT IS SERVICED OR REPLACED.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996
Resolved
RENEW BOTH LIFEBOAT DAVIT FALLS & BOTH INFLATABLE LIFERAFT DAVIT FALLS. CONDUCT WEIGHT TEST IN THE PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Documentation
Issued 14 August 1995
Resolved
SUBMIT FINAL NDT REPORT AND VIDEO TO [name withheld] FOR REVIEW.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Construction/Loadline
Issued 21 June 1995
Resolved
CONDUCT UNDERWATER PORTION OF SPECIAL EXAMINATION IN LIEU OF DRYDOCK IN ACCORDANCE WITH APPROVED PLAN DATED 06JUN95.
Condition: Unknown
Due 21 June 1995
Resolved 21 June 1995
Accommodation/Occupational Safety
Issued 24 January 1994
Resolved
Free up sanitary tank relief valve.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Restencil all PFDs with current name of vessel.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 24 January 1994
Resolved
Replace the gaskets on all watertight and weather tight doors, ajust all doors to close properly.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Electrical
Issued 24 January 1994
Resolved
Renew A.C. voltmeter on standby generator switch board.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 24 January 1994
Resolved
Renew wasted fuel line on #2 service generator.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Conduct a drilling ops emergency shut down.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Documentation
Issued 24 January 1994
Resolved
Provide a Waste Management Plan.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 24 January 1994
Resolved
Renew wasted and unapproved flex fuel line on standby generator.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Renew eductor piping in way of soft patch on #2 evap.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Electrical
Issued 24 January 1994
Resolved
Remove wire nuts on #2 evap motor connection box, and reinstall conduit.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Make permanent repairs to leaking brine pump piping on the #1 & #2 evaporators.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Documentation
Issued 24 January 1994
Resolved
Provide documentation that crane 5 yr inspections have been conducted.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 23 June 1993
Resolved
PRESENT FOR COAST GUARD INSPECTION ALL SPUD CANS AND CRITICAL CONNECITONS.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Construction/Loadline
Issued 23 June 1993
Resolved
OPEN AND PRESENT FOR COAST GUARD INSPECTION THE MUD PIT MASTER DUMP VALVE.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Lifesaving
Issued 17 December 1992
Resolved
LOWER AND OPERATE BOTH LIFEBOATS IN THE WATER PROVIDE COPY OF LOG ENTRY TO COGNIZANT OCMI.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
OPEN AND PRESENT FOR CG INSP. OR CONDUCT HYDROSTATIC TEST OF DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Lifesaving
Issued 11 February 1992
Resolved
PROVIDE ADEQUATE WATER FOR #1 MLB (EQUAL TO CAPACITY OF BOAT)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Navigation
Issued 11 February 1992
Resolved
REPLACE BROKEN OBSTRUCITON LIGHT LENSES FOR FWD AND PORT LEG.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Navigation
Issued 11 February 1992
Resolved
REPLACE WHILE LENSES ON HELO DECK WITH AMBER LINSES AND ENSURE ALTERNATINGBLUE/AMBER.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
PROVIDE HYDRO RELEASING DEVICE HAVING CURRENT TEST DATE FOR DAVIT LAUNCHED INFLATABLE LIFERAFTS #1 AND #2.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
PROVIDE SAFETY CHAIN FOR OPENING AFT OF #1 DLR.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
REPAIR OF REPLACE WINCH CONTROL SWITCH FOR #2 L/B.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
PROVE PROPER OPERATION OF #1 AND #2 L/B WINCHES - BRAKE COUNTER WEIGHT CAUSES WINCH TO DISENGAGE DURING RECOVERY.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Electrical
Issued 11 February 1992
Resolved
MAKE REPAIRS TO LEAKING WATER PUMP ON #1 GENERATOR ENGINE.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Construction/Loadline
Issued 11 February 1992
Resolved
REPAIR PORT DOOR TO MUDPIT RM AND ENXTURE PROPER CLOSING.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Fire Fighting
Issued 11 February 1992
Resolved
MAKE REPAIRS TO RIRE MAIN IN PORT P-TANK ROOM WTHER PAD WELDED, TO F/M WHERE LEAKING IN HALLIBURTON RM, AND TO PIPING AT DISCHARGE OF #2 FIRE PUMPWHERE LEAKING.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
INSTALL RELIEF VALVES ST AT NOT MORE THAN 100 PSI ON BOTH SANITARY WATER TANKS OF MAKE AVIALABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Fire Fighting
Issued 11 February 1992
Resolved
INSTALKL PROPER BRACKETS FOR FIRE EXTINGUISHERS AT BOTH 48H STATION IN SCR ROOM AND STATION 54H IN ENGINE ROOM.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Electrical
Issued 11 February 1992
Resolved
INSTALL EYS FITTINGS ON H2S ALARM LIGHT IN MUDPIT RM.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Accommodation/Occupational Safety
Issued 11 February 1992
Resolved
REPLACE RELIEF VALVES ON P-TANKS #1 AND #2; TEST NEW RELIEF VALVES IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
PROVE PROPER OPERATION OF #2 L/B WATER CURTIAN.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Navigation
Issued 11 February 1992
Resolved
LEVEL PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
PROVIDE 1 PROJECTILE AND 1 SERVICE LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Deck/Cargo
Issued 11 February 1992
Resolved
REPAIR MASTER VALVE FOR DRILL FLOOR RAW WATER OVERBOARD - STEM BENT.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 11 February 1992
Resolved
PAINT DAVIT, FALL AND WINCH CONTROL FOR DLR IAW OPERATING INSTRUCTIONS.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Fire Fighting
Issued 11 February 1992
Resolved
TIGHTEN ALL CYL HEADS FOR CO2 BOTTLES (PAINT LOCKER)
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Unknown
Issued 11 February 1992
Resolved
PROVIDE 30X30 MESH FOR PAINT LOCKER VENT OPENING.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Electrical
Issued 11 February 1992
Resolved
CORRECT ELECTRICAL BOX STBD AFT, WIRING CONVER PLATE. MAIN STBD OB OF DRAW-WORKS.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 19 April 1991
Resolved
COMPLETE INSTALLATION OF DAVIT LAUNCHED LIFE RAFTS PRIOR TO 30 JUNE 91. INSTALLATION TO BE INSPECTED BY AND WEIGHT TESTED IN PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Electrical
Issued 20 December 1986
Resolved
REPAIR LOLLOWING EMERGENCY LIGHTS: STBD SIDE DOOR ON HOUSE ABOVE LIFEBOAT #1, EXP. MESS, MVD PUMP ROOM. 46 CFR 112
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Accommodation/Occupational Safety
Issued 20 December 1986
Resolved
PROVIDE AT LEAST 12 1" ADHESIVE COMPRESSED FOR RIG'S FIRST AID KIT. 46 CFR 108.707
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Accommodation/Occupational Safety
Issued 20 December 1986
Resolved
REPAIR OR REPLACE TWO (2) P-TANK RELIEF VALVES (#5 BAYRITE TANK AND #4 CEMENT TANK). 46 CFR 61.10.5
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Deck/Cargo
Issued 20 December 1986
Resolved
REPAIR INOPERATIVE METERS AT REMOTE CONTROL STATIONS FOR CRANES: STBD CRANE-LOAD ANGLE INDICATOR METER (I.E.,CAPACITY METER)+ LOAD METER, PORT AFT-LOAD METER, PORT FWD-LOAD METER. 46 CFR 107.259
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Accommodation/Occupational Safety
Issued 20 December 1986
Resolved
REPAIR VENTILATION SHUTDOWN SYSTEM FOR QUARTERS. SYSTEM IS TO OPERATE IN ACCORDANCE WITH. 46 CFR 108.181
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 20 December 1986
Resolved
REPLACE FALLS CABLE ON BOTH LIFEBOATS OR SUBMIT EVIDENCE THAT CABLES ARE LESS THAN NINE YEARS OLD. SEE SPEC. INSTRUCTIONS BELOW. BOTH BOATS TO BE WT. TESTED IN PRESENCE OF CG INSPECTOR AFTER CABLES ARE RENEWED. 46 CFR 108.500
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 20 December 1986
Resolved
RENEW DOOR GASKETS ON THE INBOARD SIDE HATCHES OF BOTH LIFEBOATS (I.E., PORT SIDE OF LIFEBOAT NO.1 AND STBD SIDE OF LIFEBOAT NO.2). 46 CFR 109.217
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 20 December 1986
Resolved
LOW PRESSURED AIR BOTTLES IN LIFEBOAT NO.2 TO BE REFILLED. 46 CFR 109.217
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Electrical
Issued 20 December 1986
Resolved
PROPERLY SUPPORT HIGH VOLTAGE ELECTRICAL CABLE ON DRILL FLOOR NEAR DRILLER'S CONSOLE. CABLE RUNS UP DERRICK LEG. 46 CFR 111.60-80
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 20 December 1986
Resolved
BOTH LIFEBOATS TO BE OPERATED IN THE WATER. 46 CFR 109.217
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 21 August 1986
Resolved
PROVIDE STUFFING TUBES OF THE PROPER SIZE FOR THE TWO NON-STANDARD PENETRATIONS OR REMOVE AND PLUG, ELECTRICAL TRUNK - PORT SIDE AFT.
Condition: Unknown
Due 21 August 1986
Resolved 21 August 1986
Construction/Loadline
Issued 21 August 1986
Resolved
REPAIR THE HARTCHES TO THE SACK STORAGE ROOM AND THE MACH. ROOM. REPAIR THE DOGS ON THE HATCH, BULK STORAGE & HALIBURTON ROOM.
Condition: Unknown
Due 21 August 1986
Resolved 21 August 1986
Construction/Loadline
Issued 21 August 1986
Resolved
MAKE OPERATIONAL THE CHECK VALVES IN PRE-LOAD TANKS P-27, 1-A & 1B.
Condition: Unknown
Due 21 August 1986
Resolved 21 August 1986
Documentation
Issued 12 February 1986
Resolved
PROVIDE ONE ADDITIONAL LIFEBOATMEN ONBOARD AND REQUEST IN WRITING TO THE OCMI, TO HAVE REDUCED MANNING WHEN IN THE STACKED MODE. COMPLIANCE DATE IS19FEB86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Documentation
Issued 12 February 1986
Resolved
PROVIDE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Navigation
Issued 12 February 1986
Resolved
REPAINT RUNNING LIGHT SCREENS. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Navigation
Issued 12 February 1986
Resolved
PROVIDE EVIDENCE OF THE DATE WHEN THE LIFEBOAT FALLS WERE LAST RENEWED. COMPLIANCE DATE IS 12MAR86. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
PROVIDE TOOL KIT FOR #2 LIFEBOAT. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
REMOVE THE NON-APPROVED TYPE, WOODEN JACOBS LADDERS AND 2 KNOTTED MANROPES INSTALLED BETA LIFERAFT STATIONS ON THE PORT/STBD SIDES. COMPLIANCE DATE IS 19FEB86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
PROVIDE 17 ADDITIONAL TRIANGULAR BANDAGES FOR THE FIRST AID KIT. COMPLIANCE DATE IS 12FEB86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
PROVIDE PROPER ATTACHMENT OF RETROREFLECTIVE MATERIAL ON LIFE PRESERVERS. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Deck/Cargo
Issued 12 February 1986
Resolved
PROVIDE CAPS ON GRAVITY DRAINS FROM FUEL AND LUBE OIL TANKS. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Electrical
Issued 12 February 1986
Resolved
REINSTALL ELECTRICAL PROTECTIVE MATS IN GENERATOR/SCR ROOM. COMPLIANCE DATE IS 19FEB86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Construction/Loadline
Issued 12 February 1986
Resolved
ADJUST ALL WATERTIGHT DOORS SO THAT DOORS CLOSES PROPERLY. COMPLIANCE DATEIS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Electrical
Issued 12 February 1986
Resolved
PROVIDE EMERGENCY LIGHTING IN THE ELECTRICIAN'S SHOP. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Construction/Loadline
Issued 12 February 1986
Resolved
PROVIDE REMOTE SHUTOFF FOR AIR OPERATED LUBE OIL PUMP. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Deck/Cargo
Issued 12 February 1986
Resolved
PLUG SMALL SECONDARY FUEL VENT INSIDE STANDBY GENERATOR COMPARTMENT. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Deck/Cargo
Issued 12 February 1986
Resolved
REINSTALL VENTILATION FANS TO MUD PIT ROOM AND PROVE PROPER OPERATION PRIORTO PLACING THE RIG BACK IN SERVICE. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
DRAIN BILGES/PERMANENTLY SECURE BOAT PLUG IN #2 LIFEBOAT. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 12 February 1986
Resolved
PROVIDE 3 ADDITIONAL PARACHUTE FLARES. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Engineering
Issued 12 February 1986
Resolved
PROVE PROPER OPERATION OF THE LUBE OIL LOW PRESSURE ALARMS ON THE MAIN GENERATORS. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Deck/Cargo
Issued 12 February 1986
Resolved
INSTALL RELIEF VALVES ON HOT WATER TANKS TO RELIEVE LESS THAN 100 PSIG OR MAKE AVAILABLE FOR INTERNAL INSPECTION. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Deck/Cargo
Issued 12 February 1986
Resolved
INSTALL HEAT RESISTANT SIGHT GLASS AND GUARDS ON LUBE OIL TANK IN MUD PUMP ROOM. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Lifesaving
Issued 8 December 1984
Resolved
PROVIDE A USCG APPROVED FIRST AID KIT FOR THE PORT LIFEBOAT, 46CFR108-503.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Lifesaving
Issued 8 December 1984
Resolved
PROVIDE A COMPASS LIGHT FOR THE LIFEBOAT COMPASS IN THE #1 AND #2 LIFEBOAT REF NVC 4-78 & 46CFR108.503(D) 46CFR108.503.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Deck/Cargo
Issued 8 December 1984
Resolved
PROVIDE EVIDENCE THAT THE MPT TANKS FOR LPG GAS ARE BUILT IN ACCORDANCE WITH 46CFR64. IF NOT BUILT UNDER PART 64 REMOVE THEM FROM THE RIG. 46CFR64.7
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Accommodation/Occupational Safety
Issued 8 December 1984
Resolved
MAKE PERMANENT REPAIRS TO THE WASTE AND LEAKING WATER MAKER OVERBOARD DISCHARGE PIPING LOCATED IN THE OVERHEAD OF THE EMD ROOM. 46CFR56-50-95.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Lifesaving
Issued 8 December 1984
Resolved
PROVIDE NEW GASKETS FOR THE DOORS ON THE PORT LIFEBOAT. 46CFR160.035
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Lifesaving
Issued 8 December 1984
Resolved
PROVIDE NEW COVER OR REPAIR PRESENT COVER ON THE LIFEJACKET BOX IN WAY OF THE STBD LIFEBOAT LANDING, NVC 4-78 & 46CFR108.514.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Unknown
Issued 8 December 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO PENROD 82, DN 602912.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984
Unknown
Issued 7 December 1983
Resolved
PROVIDE A PORTABLE 5 GALLON GAS CAN, OR LESS WITH A SELF CLOSING SPOUT FOR REFUELING FORKLIFT. NVC 4-78 (46 CFR 109.537).
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Unknown
Issued 7 December 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 82 DN602912.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
IN SCR ROOM PROVIDE NON-CONDUCTIVE MATTING BEHIND THE ENTIRE LENGTH OF THE REAR SWITCHBOARD AND BREAKER PANELS. NVC 4-78 (46 CFR 111.30-1(C)).
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Unknown
Issued 7 December 1983
Resolved
DEMONSTRATE OPERATION OF HIGH BILGE ALARM.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
REPLACE WATER FOUNTAIN COVER PLATE IN MUD PUMPROOM.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
IN PORT SACK STORAGE ROOM PROPERLY MOUNT CONTROLLER FOR VENT FAN.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
IN PORT HOOPER ROOM PERMANENTLY MOUNT CONTROLLER TO VENT FAN.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
LABEL MOTOR CONTROLLERS THROUGHOUT RIG AS TO WHICH MOTOR EACH CONTROLS. NVC 4-78 (46 CFR 111.70-200)
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Lifesaving
Issued 7 December 1983
Resolved
RELOCATE RETROREFLECTIVE TAPE ON LIFE PRESERVERS IN THE UPPER QUADRANT IN ACCORDANCE WITH 46 CFR 108.514.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
PROPERLY MARK VENT SHUTDOWN SWITCHES LOCATED ON DRILL FLOOR AND OUTSIDE THELOWER QUARTERS TO INCLUDE "FUEL OIL PUMP SHUTDOWN" 46 CFR 58.01-25.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Fire Fighting
Issued 7 December 1983
Resolved
PROVIDE RUBBER (OR OTHER ELECTRICALLY NON-CONDUCTIVE MATERIAL) GLOVES FOR THE FIREMON'S OUTFIT LOCATED IN THE ENGINE ROOM SPACE. 46 CFR 108.497.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Navigation
Issued 7 December 1983
Resolved
PROVIDE 2 ADDITIONAL BLACK BALL DAY SHAPES 72 COLREGS.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
REPLACE GENERAL ALARM HORNS WITH BELLS (46 CFR 113.25-5)
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
ON DRILL FLOOR, PROVIDE LOSS OF PURGE AIR ALARM FOR THE GAS DETECTOR AND THE FLOW METER. NVC 4-78.3D(10).
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Electrical
Issued 7 December 1983
Resolved
IN SHAKER HOUSE, MAKE THE LOUDS REAKER SUITABLE FOR USE IN A CLASSIFIED LOCATION. NVC 4-78 (46 CFR 108.170) (46 CFR 111.80-5).
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Construction/Loadline
Issued 7 December 1983
Resolved
PORT MUD PIT DOOR; REPAIR AUTOMATIC CLOSER AND ADJUST DOOR TO CLOSE TIGHT.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983
Documentation
Issued 8 December 1982
Resolved
PROVIDE CONSTRUCTION PORTFOLIO ABOARD RIG.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
PROVIDE SIX PARACHUTE FLARES.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
PROVIDE EYS SEAL TO TOP OF MOTOR CONTROLLLER OUTSIDE OF SHALE SHAKER ROOM AND REPAIR/REPLACE EYS SEAL TO BOTTOM OF CONTROLLER.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Fire Fighting
Issued 8 December 1982
Resolved
PROVIDE ADDITIONAL FIRE STATION AT HELICOPTER DECK ACCESS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
FLOOR: REPLACE CRIMPED WIRE TO PLUG BOX IN DRILLER'S SHACK. PROPERLY SUSPENSUSPEND ALL WIRING WITH METAL BANDING. PROVIDE EYS SEAL ON JUNCTION BOX TO
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
TO BUG BLOWER. REPAIR CIRCUIT BREAKER ON MAIN PANEL FOR FLOOR LIGHTING.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Unknown
Issued 8 December 1982
Resolved
REPAIR ALARM INDICATORS ON PANEL FOR HIGH BILGE ALARMS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
REPLACE GUARDS ON MUD PIT VENT FANS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
REPLACE MISSING BULBS IN GROUND FAULT INDICATOR OR LIGHTS FOR SECONDARY FEEDER PANEL.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
PROPERLY FILL EYS SEAL ON HORN AT MIX HOPPER.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
REPLACE GUARD ON EXCITATION GENERATOR COUPLING ON NO. 1 S/S GENERATOR.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
REPAIR GENERAL ALARM HORNS IN: MUD PUMP ROOMS, SCR ROOM, SHAKER AND DRILL FLOOR. PROVIDE GENERAL ALARM BELL IN MUD PITS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
CORRECT THE FOLLOWING DISCREPANCIES IN HAZARDOUS LOCATIONS: (A) MUD PITS: PROVIDE EYS SEAL ON JUNCTION BOX ON BEAM ABOVE NO. 2 MUD PITS. (B) SHAKER:
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Documentation
Issued 8 December 1982
Resolved
PROVIDE CURRENT MARINE DOCUMENT ABOARD THE RIG.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
PROPERLY SUSPEND AND ROUTE WIRING IN AREA OUTSIDE CONTROL ROOM.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Navigation
Issued 8 December 1982
Resolved
PROVIDE ALTERNATE BLUE AND AMBER LIGHTS ON PERIMETER OF HELICOPTER DECK.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
PROVIDE FOUR MONKEY FISTS ATTACHED TO FOUR HEAVING LINES (TWO PER LIFEBOAT).
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
PROVIDE ONE AUXILIARY LINE THROWING DEVICE.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
PROVIDE TOW ELECTRICAL PANEL SWITCH BLANKS TO ELECTRICAL PANEL LC12 IN THIRD DECK QUARTER'S CORRIDORS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Electrical
Issued 8 December 1982
Resolved
REPAIR EMERGENCY LIGHTS LOCATED IN QUARTER'S SECOND DECK CORRIDOR, STARBOARD GALLEY, AND MUD PIT ROOM.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Construction/Loadline
Issued 8 December 1982
Resolved
ADJUST/REPAIR WATERTIGHT DOOR FROM QUARTERS TO PIPEDECK ON VESSEL CENTERLINE TO MAKE ALL DOGS CONTACT AND DOOR TIGHT.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Construction/Loadline
Issued 8 December 1982
Resolved
REPLACE DOG ON WATERIGHT DOOR FROM SACK ROOM TO BULK TANK ROOM.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Construction/Loadline
Issued 8 December 1982
Resolved
ADJUST/REPAIR PORT WATERTIGHT DOOR FROM PIPE DECK TO QUARTERS TO MAKE TIGHT.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
PROVIDE FOLLOWING EQUIPMENT TO LIFEBOAT NO.1 (STBD) (A) TWO BUCKETS (B) ONEHATCHET (C) INTERIOR LIGHT OR TWO MOUNTED BATTERY LIGHTS WITH SPARE
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
BATTERIES. (D) ONE HAMMER. (E) ONE ADJUSTABLE WRENCH. (F) ONE SCREWDRIVER. (G) ONE ORANGE SMOKE SIGNAL (H) TWELVE HANDHELD FLARES (I) 396 CANS OF
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
WATER.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
PROVIDE FOLLOWING EQUIPMENT TO BOAT NO. 2 (PORT): (A) TWO BUCKETS. (B) INTERIOR LIGHT OR TWO MOUNTED BATTERY LIGHTS WITH SPARE BATTERIES. (C) TWO
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Lifesaving
Issued 8 December 1982
Resolved
HATCHETS. (D) TWELVE HAND HELD FLARES. (E) ONE ADJUSTABLE WRENCH. (F) 396 CANS OF WATER. (G) ONE WHISTLE. (H) ONE TABLE OF LIFESAVING SIGNALS.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982
Fire Fighting
Issued 8 December 1982
Resolved
MAKE PERMANENT REPAIRS TO SUCTION LINE ON NO. 2 FIRE PUMP.
Condition: Unknown
Due 8 December 1982
Resolved 8 December 1982