THELMA DALE V

THELMA DALE V is a 1976 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1981, most recently in January 2026, along with 178 deficiencies.

Records from 1981 to 2026. Most recent: inspection, 20 January 2026.

Built
1976
Last inspected
20 January 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP2626
Flag
UNITED STATES
367490250
Maury page id
psix-48884

Inspections, by type

…with no type recorded21
Years with a record 39 calendar years (1981–2026)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)96.4 ft × 23.5 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDYNAMIC SHIPBUILDERS INC · CROWN POINT, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLEWES, DE
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2626MMSI 367490250 · active · compulsorily equipped · granted 17 October 2023, expires 17 October 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDF7992MMSI 367490250 · expired · compulsorily equipped · granted 13 May 2011, cancelled 17 July 2021
WDA2028MMSI not assigned · expired · compulsorily equipped · granted 24 August 2000, cancelled 30 October 2010
WRA3879MMSI not assigned · expired · compulsorily equipped · granted 2 May 1994, cancelled 8 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS AVALON Passenger (Inspected) · MISLE 243860 · 29 June 1993 · activity 165467

Inspection history · 92

20 January 2026 Annual Inspection · Administrative Inspection · Vessel Attendance · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8296893
20 August 2025 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8214169
14 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8110078
24 January 2025 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8067084
1 November 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7810106
17 October 2023 Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7809420
10 August 2023 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7771431
1 November 2022 Hull Examination · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7587234
13 October 2020 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7073094
2 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7070283
25 August 2020 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7042066
27 August 2019 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6795849
3 October 2018 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6553379
25 April 2018 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408304
23 August 2017 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6248763
4 May 2017 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6143240
10 May 2016 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5870814
30 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5850190
23 July 2015 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5193059
26 July 2012 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4374101
3 May 2012 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4313918
8 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3261541
19 November 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3157964
27 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2915855
12 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2710134
25 April 2006 COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2627340
13 October 2005 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2513436
29 June 2005 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2405964
4 May 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2348904
26 May 2004 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2078560
7 October 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1934810
6 August 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1863914
2 August 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1655810
10 October 2001 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1395810
22 April 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1064996
26 January 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1378945
16 December 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1412025
2 October 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1349177
25 April 1999 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 807256
6 October 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 801421
16 July 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1460213
15 July 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1451212
18 June 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1435938
15 May 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 664448
25 April 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 141126
6 June 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1392479
7 June 1995 Deficiency Check · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1186304
25 April 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1345143
21 June 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1329831
9 June 1994 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1324268
30 April 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 183398
17 March 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1165043
17 November 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 848104
4 November 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1152719
22 September 1993 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1151149
9 September 1993 Plan Review "T" Boat
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1144546
27 August 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1135855
4 July 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 124937
29 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 165467
29 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 219484
10 June 1993 Deficiency Check · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 833224
26 April 1993 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 836857
4 December 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 171992
29 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 945105
10 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 946523
10 June 1992 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 958228
4 November 1991 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1248902
13 June 1991 COI Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1342891
20 December 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 930721
27 July 1990 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 930532
12 July 1990 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1213832
6 June 1990 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1221365
14 November 1989 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1216379
28 September 1989 Drydock Extension
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1310487
18 July 1989 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 893003
9 June 1989 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1202005
26 July 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1033955
7 June 1988 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 888226
15 March 1988 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1337366
9 June 1987 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1029806
3 April 1987 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1328138
2 July 1986 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 997752
28 March 1986 Credit Drydock
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1305453
25 June 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1292092
25 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 972986
25 January 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1285519
18 December 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 977499
29 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974223
29 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279378
9 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271866
27 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271869
25 September 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966873

Deficiency record · 178

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 January 2026 Resolved
Vessel shall have on board the current COD currently in effect. Vessel's COD is expired. 46CFR67.313
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2026
Resolution: O/O showed proof of payment and application for renewal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2026 Resolved
At each inspection the fire fighting equipment shall be inspected. Portable fire extinguishers exceeded the annual external visual examination requirements in NFPA 10 7.3.1. 46CFR176.25-25
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 March 2026
Resolution: All portable fire extinguishers have been serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 January 2025 Resolved
Machinery fittings and fuel systems for main engines and auxilliary shall be checked. Diesel fuel leak found on the port generator. Operations restricted to the STBD generator until fuel leak secured and inspected by an MI. 46CFR176.25-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2025
Resolution: Diesel leak secured. MI witnessed operational test of the generator with no leaks present.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2025 Resolved
Adequate emergency lighting automaticaly actuated upon failure of the main lighting system shall be fitted along escape route. Emergency lighting crew space was not operational. Ensure crew has flashlight prior to entering these spaces until corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2025
Resolution: O/O replaced batteries in emergency lighting and verified connections sound. MI verified operation of all three emergency lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 January 2025 Resolved
Rails shall consist of spaced courses not greater than 12". Top deck railing course from the mid to upper is greater than 12".
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2025
Resolution: Additional wire line course placed on upper deck which reduced the course opening to less than 12".
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2025 Resolved
At each inspection the firefighting equipment shall be inspected. 07 portable fire extinguishers are past the 6-year maintenance outlined in table 7.3.1.1.2 in NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2025
Resolution: O/O placed new portable fire extinguishers in service.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 January 2025 Resolved
Life floats shall be furnished with lifeline and pendants. Lifeline and pendants deteriated from the weather and need replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2025
Resolution: New grab lines attached the all six life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2023 Resolved
All vessels shall be provided with satisfactory arrangements for draining watertight compartments. Vessel unable to pump bilge compartment in the galley space. 46CFR182.25-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: O/O tested bilge suction from each space served by the bilge manifold system. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 November 2023 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached. Several life floats were not attached to the float-free link. 46CFR180.130
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Life floats properly hooked up to float free link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2023 Resolved
Fuel shutoff valves at the fuel tank shall be operable from outside the tank compartment. Emergency fuel shutoff valve for port fuel tank is inoperable. 46CFR182.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Port fuel tank emergency shutoff fully operational.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 13 October 2020 Resolved
Aft deck door hinges cracked
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Door hinge replaced
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 October 2020 Resolved
Port, STBD and sft main deck lower passenger exterior is wasted and holed, replace in kind/ provide repair plan for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Doubler aluminum plate welded in base of passenger interior cabin.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 13 October 2020 Resolved
Main deck exterior lighting housings replace and install lens gaurd
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Exterior ighting house and lenses replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 October 2020 Resolved
STBD main deck midship has overflow guard damaged and missing check ball
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Overflow guard placed in good service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 October 2020 Resolved
STBD goose neck vent missing insect screen and clamp
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Gooseneck vent for fuel and potable water had screen and clamp in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2020 Resolved
STBD forward access to pilothouse has 2" cracked weld
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Doubler aluminum plate welded in place, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Top pilothouse electrical box broken for flood light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: New electrical box placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Operating station aft, broken transfer switch
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Transfer switch replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 13 October 2020 Resolved
Forward peak: Capstan hose between 1st and 2nd frame stbd side damaged. Replace with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: New hose placed in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 October 2020 Resolved
Galley: Prove that the windows and hatch are not leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: O/O sealed hatch and windows. MI verified no water leaking with hose saturating area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
[name withheld]/Crew room:Stbd forward outlet cover is missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Outlet covers replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 13 October 2020 Resolved
Rod room/Crew room: Replace all missing pipe hangers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Piper hangers placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 13 October 2020 Resolved
Rod room/Crew room:Ballast piping wasted and holed at aft bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Piping replaced with new pipe.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 October 2020 Resolved
Engine room: Port and STBD fuel vent hoses. Replace in kind and bond correctly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2023
Resolution: F/O tank vent lines replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Engine room: Properly install fire pump remote controller.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Fire pump start hard wired in, remote control has been disconnected.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 October 2020 Resolved
Engine room:Aft stbd light fixture damage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Light fixture replaced and in good condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Engine room:Replace stbd forward outlet for hot start and properly secure stbd aft outlet above battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Outlets secured and good working order.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 October 2020 Resolved
Engine room:Inspect and install missing/loose wasted hose calmps on wet exhaust pipes. (all three engines)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2023
Resolution: New wet exhaust boots and clamps provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 October 2020 Resolved
Engine room:STBD aft bulkhead holed and pitted. Clean and make ready for inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2023
Resolution: Aft engine room bulkhead cropped and renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 October 2020 Resolved
Engine room:Stbd house pump ball valve is damged. Replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Valves in house pump have been replaced and in good servicable condition.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 October 2020 Resolved
Engine room:Clean and make all through hull valves ready for inspection.
Action required: 705 - Other - as specified
Resolved 14 February 2023
Resolution: All sea valves renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 October 2020 Resolved
Engine room:Center engine shifter bracket loose, properly secure
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Engine shifter brackets have been tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2020 Resolved
Engine room:Replace center engine turbo line as reported
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Turbo line replaced with hard pipe. Ran engine, no leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 October 2020 Resolved
Engine room:Bilge manifold ball valves need to be properly installed and tested for proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Exercised bilge manifold valves. Pumped bilge from fwd compartment, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2020 Resolved
Engine room:Inspect all battery trays and properly tighten.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Battery trays secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2020 Resolved
Generator room: Outboard hydraulic pump wiring is exposed. Properly secure
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2023
Resolution: Wiring secured in generator room.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2020 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessel has not completed a credit drydock examination within two years. 46 CFR 176.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2020
Resolved 13 October 2020
Resolution: Hull examination started by MSD Fort Macon.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 August 2020 Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. Vessel's Radio Safety Certificate expired in June of 2020. Vessel is restricted to a lakes, bays, and sounds route not more than 1000 feet from shore. 47 CFR 80.901
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 26 August 2020
Resolution: Vessel received a valid FCC Safety Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 August 2020 Resolved
The following spaces must be equipped with a fire detecting system of an approved type that is installed in accordance with 76.27 in sub-chapter H of this chapter, Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit in compliance with 46 CFR 181.450 prior to carrying overnight passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 31 August 2020
Resolution: Vessel's crew had replaced two (02) smoke detectors and replaced batteries for one (01). All installed smoke detectors found in satisfactory service.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 August 2020 Resolved
Any vessel on an Oceans route must carry six red flares and six orange smoke flares or alternately twelve red distress flares. Vessel had only eight valid red distress flares. Vessel restricted to a Lakes, Bays, and Sounds route. 46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 26 August 2020
Resolution: 12 valid red flares were placed on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 August 2020 Resolved
Life floats and buoyant apparatus must not be secured to the vessel except by the painter and by lashings which can be easily released or hydraulic releases. Life floats were found tied to the vessel's hand rails and later removed by vessel's crew. 46 CFR 180.20-1 (a)(7)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 25 August 2020
Resolved 25 August 2020
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 25 August 2020 Resolved
Piping for vital systems must be composed of ferrous materials. A soft patch was observed on the discharge side of the vessel's fire main/bilge system. Complete repairs to the satisfaction of the attending marine inspector no later than 1 SEP 2020. 46 CFR 182.710 (c)(1)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 September 2020
Resolved 31 August 2020
Resolution: Vessel's owner and crew had replaced holed section of the bilge/fire discharge. Bilge discharge was satisfactorily tested by pumping water from the galley's bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 25 August 2020 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. The vessel was equipped with three alcohol test strips. Vessel manning requires one master and three crew members. Vessel must have four test strips. Vessel restricted to excursions less than two hours from alcohol testing facilities. 46 CFR 16.240
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 31 August 2020
Resolution: An adequate number of alcohol test strips were placed on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2020 Resolved
All vessels shall be provided with an approved adult and child type life preserver for each person carried. Vessel is missing 11 adult life preservers and three child life preservers. Vessel’s passenger count is reduced to 117 adult passengers and 11 child passengers until replacement is verified by the attending marine inspector. 46 CFR 180.71
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 31 August 2020
Resolution: The correct number of adult and children's lifejackets were placed on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2020 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments under all practical conditions. The vessel was unable to satisfactorily pump the bilge in the galley using the vessel fixed bilge pump. After taking corrective action vessel's crew was able to make repairs and return the system to an operational condition. 46 CFR 182.25-1(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2020
Resolved 25 August 2020
Resolution: Vessel's crew was able to make repairs and return the system to an operational condition
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 August 2020 Resolved
Means shall be to taken ensure the vessel is reasonably safe from fire caused by and or originating in electrical equipment and reasonably safe from electrical shock of personnel. Numerous dead-end wires were located in the engine room, generator room, and galley. Vessel's crew capped and taped the ends of all identified dead end wires.Means shall be to taken ensure the vessel is reasonably safe from fire caused by and or originating in electrical equipment and reasonably safe from electrical shock of personnel. Numerous dead-end wires were located in the engine room, generator room, and galley. Vessel's crew capped and taped the ends of all identified dead end wires. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2019 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment... under all practical conditions. Installed bilge system was unable to drain bilge area under bunk/rod room. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2019
Resolved 28 August 2019
Resolution: Satisfactory temporary repair made to holed section of bilge suction line.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2019 Resolved
At each inspection and reinspection the marine inspector shall examine the bilges... to see that there is no accumulation of oil or other matter which might create a fire hazard. An excessive amount of oil was present in the engine room bilges. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2019
Resolved 28 August 2019
Resolution: Oil was manually removed from engine room bilge by crewmembers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Several of the low-pressure, USCG A1 fuel hoses over 30 inches do not meet SAE J-1942.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 27 September 2019
Resolution: Verified all fuel hose over 30" located in front of main engines near fuel filters is now SAE-J1942 approved hose.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 28 August 2019 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel unless any required alcohol tests can be conducted within 2 hours from the time of occurrence of a serious marine incident.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 27 September 2019
Resolution: Testing devices now provided on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 August 2019 Resolved
Gauges to indicate lubricating oil pressure shall be provided for all propulsion engines. Oil pressure gauges for center and starboard engines are inoperable. 46 CFR 182.50-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2019
Resolved 25 August 2020
Resolution: All oil pressure gauges were in working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2019 Resolved
The intent of this part is to insure that... auxiliary machinery is suitable for the purpose intended. Bilge system was found with hole in bilge suction line from bilge under galley compartment thereby rendering bilge pump ineffective. Temporary repair was installed on holed bilge suction line. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 27 September 2019
Resolution: Verified hard pipe repair made. Witnesed operation of bilge pump through repaired section of piping - SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 August 2019 Resolved
Vessels must underdo/complete an annual inspection within the three months before or after each anniversary date. Vessel has to complete its annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2019
Resolved 28 August 2019
Resolution: Vessel completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2018 Resolved
Per Table 181.500(b), galley spaces are required to contain one 40-B:C (minimum rating) portable fire extinguisher. A properly serviced fire extinguisher is not provided in the galley. 46 CFR 181.500
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 October 2018
Resolved 3 October 2018
Resolution: Proper extinguisher provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2018 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be water jacketed or adequately insulated. Insulating wrap just aft of turbo is falling off on several main engine exhaust pipes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 25 August 2020
Resolution: Exhaust pipes were properly protected.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 3 October 2018 Resolved
A vessel greater than 65 feet must carry a rescue boat unless the cognizant OCMI determines that the vessel is sufficently maneuverable, arranged and equipped with a fully satisfactory rescue platform. During man overboard drill, crew members struggled to maintain control of the rescue platform.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 28 August 2019
Resolution: Verified rescue platform has been reduced in size to limit the amount of ladder hanging in the water. Platform was properly secured in place by crew without incident. Verified during 2019 annual inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 July 2015 Resolved
Replace anchor light lens.
Action required: 705 - Other - as specified
Resolved 24 July 2015
Resolution: Anchor light lens replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 July 2015 Resolved
Repair/test bilge alarms.
Action required: 705 - Other - as specified
Resolved 24 July 2015
Resolution: Tested bilge alarms satisfactorily.
Fire Fighting › Fire Pumps › Pressure
Issued 26 July 2012 Resolved
Provide fire pump that provides 60 PSI and 50 GPM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Tested fire pump satisfactorily.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2012 Resolved
Provide bilge pump at 50GPM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Tested bilge pump satisfactorily.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 July 2012 Resolved
Provide E/R high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: E/R high water alarm provided. Tested satisfactorily.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2012 Resolved
Test bilge system by pumping al compartments except E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Tested bilge pumpming system by pumping out crew quarters and galley compartments. All sat.
Lifesaving › Lifefloat › Markings
Issued 26 July 2012 Resolved
Stencil lifefloats and life rings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Lifefloats and liferings have been stenciled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 July 2012 Resolved
Replace line on lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Lifering line replaced. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2012 Resolved
Repair/replace shore-tie.
Action required: 705 - Other - as specified
Resolved 27 July 2012
Resolution: Shore-tie repaired. All sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 July 2012 Resolved
Provide "blanks" for circuit breaker panels in galley and aft main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Blanks provided for breaker panels.. All sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 July 2012 Resolved
Repair emergency light in crew quarters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Emergency light in crew quarters repaired. Tested sat.
Communications › Alarms/Indicators › Fire Alarm
Issued 26 July 2012 Resolved
Repair smoke detector in crew quarters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Smoke detector repaired. Tested sat.
Electrical › Electric Generation Source (service) › Panelboard
Issued 26 July 2012 Resolved
Label service generator panel.
Due 2 August 2012
Resolved 27 July 2012
Resolution: Generator panel labeled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 July 2012 Resolved
Provide storage for batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2012
Resolution: Batteries removed from vessel. All sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 July 2012 Resolved
Repair/replace electrical outlets in E/R.
Due 13 August 2012
Resolved 20 August 2012
Resolution: Outlets replaced in E/R.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 July 2012 Resolved
Provide EAP placard.
Due 2 August 2012
Resolved 27 July 2012
Resolution: EAP placard provided and displayed in main deck accommodations.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 July 2012 Resolved
Repair/replace florescent light fixture in E/R.
Due 13 August 2012
Resolved 20 August 2012
Resolution: Florescent light replaced. All sat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 May 2012 Resolved
Permanently affix draft marks to hull.
Action required: 705 - Other - as specified
Resolved 1 April 2014
Resolution: Vessel permanently affixed draft marks.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 July 2008 Resolved
numerous electrical wires not properly retained nav bridge.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 14 October 2008
Resolution: wire retention greatly improved.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 July 2008 Resolved
ring buoy float light line exceeds 6 ft.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 24 October 2008
Resolution: ring buoy float light now approximately 40 inches.
Lifesaving › Rocket Parachute Flares › General
Issued 8 July 2008 Resolved
flares are expired
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 14 October 2008
Resolution: new flares acquired.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 8 July 2008 Resolved
no stencils are employed specifically for fuel shut off valves and emergency exits
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 24 October 2008
Resolution: proper stencils are now present.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 July 2008 Resolved
safety radiotelephony certificate expired.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 14 October 2008
Resolution: proper certificates retained on board.
Construction/Loadline › Hull › Weld
Issued 19 November 2007 Resolved
Cracked Welds in various places. Required cracks be ground out and rewelded.
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Confirmed all cracked welds had been ground out and rewelded satisfactorily
Lifesaving › Lifefloat › Serviceable
Issued 26 April 2007 Resolved
Repair starboard center 22 man lifefloat. Oceans route temporarily reduced to 106 passengers, 10 total persons until repaired.
Condition: Improper/Lack of Maintenance
Due 17 May 2007
Resolved 6 November 2007
Resolution: Repaired
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 25 April 2006 Resolved
Provide a proper mounting cabinet for the new center main diesel engine gauge console at the operating station.
Due 25 May 2006
Resolved 12 July 2006
Resolution: Gage mounted.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 April 2006 Resolved
Repair battle lantern below deck that points to aft crew space egress ladder.
Due 25 May 2006
Resolved 12 July 2006
Resolution: Light repaired.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 April 2006 Resolved
Repair and reposition the below deck battle lantern to shine on the forward egress ladder of the crew space.
Due 25 May 2006
Resolved 12 July 2006
Resolution: Light moved.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 25 April 2006 Resolved
Install blanks in the open spaces in the galley electrical distribution panel.
Due 25 May 2006
Resolved 12 July 2006
Resolution: Blanks installed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 April 2006 Resolved
Provide both air receivers for inspection no later than 30 June 2006
Due 30 June 2006
Resolved 12 July 2006
Resolution: Inspected both recievers. Port reciever to be replaced prior to 1 Nov 2006.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 April 2006 Resolved
Remove all excess oil from engine room bilges.
Due 25 May 2006
Resolved 12 July 2006
Resolution: Oil Removed.
Engineering › Fuel Oil Service System › Hose
Issued 1 November 2005 Resolved
New engine installation fuel hose was not found on SAE list of qualified hoses.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 12 July 2006
Resolution: Hose replaced.
Engineering › Fuel Oil Service System › Hose
Issued 13 October 2005 Resolved
Stbd generator fuel hose found chaffed on engine foundation.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 25 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 May 2005 Resolved
Prior to carrying passengers, degrease all main engines, properly attach all exaust lagging and ensure all oil is removed from the engine room bilges.
Condition: Improper/Lack of Maintenance
Due 4 May 2005
Resolved 6 May 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 May 2005 Resolved
Install new glass in the starboard pilothouse window.
Condition: Damaged By Earlier Event
Due 4 June 2005
Resolved 29 June 2005
Lifesaving › Lifefloat › Serviceable
Issued 4 May 2005 Resolved
Repair paint coating cracks on five lifefloats with the manufacturer's approved repair compound.
Condition: Improper/Lack of Maintenance
Due 4 June 2005
Resolved 10 November 2005
Lifesaving › Lifefloat › Pendant
Issued 4 May 2005 Resolved
Provide new pendants and grab lines on the port center lifefloat.
Condition: Improper/Lack of Maintenance
Due 4 June 2005
Resolved 29 June 2005
Lifesaving › Lifefloat › Paddle
Issued 4 May 2005 Resolved
Stencil all lifefloat paddles with the vessel's name.
Condition: Improper/Lack of Maintenance
Due 4 June 2005
Resolved 10 November 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 May 2005 Resolved
Repair all high water bilge alarms, label all indicating lights at the operating station and provide for testing to a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 4 June 2005
Resolved 29 June 2005
Resolution: Tested all, sat.
Stability › Watertight Integrity › General
Issued 4 May 2005 Resolved
Repair the watertight door indicator light at the operating station for the galley and crew's room watertight door.
Condition: Improper/Lack of Maintenance
Due 4 June 2005
Resolved 29 June 2005
Resolution: Tested sat.
Construction/Loadline › Penetrations
Issued 7 October 2003 Resolved
Install doubler plate on STBD side of engine room.
Condition: Improper/Lack of Maintenance
Due 7 November 2003
Resolved 2 June 2004
Construction/Loadline › Structures
Issued 7 October 2003 Resolved
Replace cracked welds port side rod room 4th frame from the aft in overhead.
Condition: Improper/Lack of Maintenance
Due 7 November 2003
Resolved 2 June 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 7 October 2003 Resolved
Clean and prepare for inspection the engine room and genertor bilges.
Condition: Improper/Lack of Maintenance
Due 7 November 2003
Resolved 2 June 2004
Electrical › Lighting (emergency)
Issued 1 August 2003 Resolved
PROVIDE AUTOMATIC EMERGENCY LIGHTS FOR 3 LOWER COMPARTMENTS LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 2 June 2004
Engineering › Bilge Water Management System › Pump
Issued 1 August 2003 Resolved
RECONNECT M/E BILGE PUMP.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2003
Resolved 7 August 2003
Construction/Loadline › Hull
Issued 1 August 2003 Resolved
AT NEXT DRYDOCK BUT NO LATER THAN 30OCT2003 WELD DOUBLERS ON 3 THRU HULL PENETRATIONS IN ENGINE ROOM LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 7 October 2003
Resolution: Installed doublers.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 August 2003 Resolved
STENCIL "EMERGENCY EXIT, KEEP CLEAR. LEGACY COMPONENT DESC: Safety notice
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 2 June 2004
Lifesaving › Buoyant Apparatus
Issued 2 August 2002 Resolved
RENEW TO ORGINAL ALL LIFE/GRAB LINE ON LIFE FLOATS PRIOR TO CARRING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2002
Resolved 7 August 2002
Lifesaving › Buoyant Apparatus
Issued 2 August 2002 Resolved
PROVIDE WATERLIGHT BRACKET FOR PORT SIDE LIFEFLOAT WATER LIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2002
Resolved 7 August 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 2 August 2002 Resolved
PROVIDE GRAB RAIL, SEA RAIL, AND LOCKING DEVICE FOR STOVE PRIOR TO USE.
Action required: 705 - Other - as specified
Due 13 August 2002
Resolved 7 August 2002
Construction/Loadline
Issued 16 July 1998 Resolved
PROVE PROPER OPERATION OF THE BILGE SYSTEM UTILIZING THE FIRE PUMP.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Construction/Loadline
Issued 16 July 1998 Resolved
REPAIR OR REPLACE TWO FLUSH DECK HATCHES AFT AND PROVE PROPER OPERATION OF THE DOGGING MECHANISMS.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Electrical
Issued 15 July 1997 Resolved
PROVIDE PROPER COVER FOR ELECTRICAL JUNCTION BOX ON FWD BKHD IN STEERING SPACE.
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Electrical
Issued 15 July 1997 Resolved
REPLACE ELECTRICAL DISTRIBUTION PANEL FACE PLATE AND DOOR. PANEL IN AFT MAIN CABIN.
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Electrical
Issued 6 June 1996 Resolved
PROVIDE PROPERLY WIRED OVERHEAD LIGHTING FIXTURES IN LOWER DECK MIDSHIPS AND FWD HEADS, AND IN PORT AND STBD LOWER CABINS.
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Engineering
Issued 6 June 1996 Resolved
IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR, PROVE ADEQUATE HYDROSTATIC TEST AT 125% MAWP FOR BOTH MDE AIR RECIEVERS.
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 6 June 1996 Resolved
REMOVE DECK MOUNTED FILL CAP FOR UNUSED OIL STORAGE TANK IN STERN COMPT, AND PROPERLY WELD INSERT TO MATCH EXISTING DECK STRUCTURE.
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Accommodation/Occupational Safety
Issued 6 June 1996 Resolved
REPLACE FRACTURED DECK AND TRANSVERSE DECK FRAME AT BASE OF EMERGENCY ESCAPE LADDER AT AFT END OF LOWER CABIN.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Construction/Loadline
Issued 6 June 1996 Resolved
PROVIDE PROPER STUFFING TUBE FOR FATHOMETER CABLE AT BILGE LEVEL OF SUBDIVISION BKHD AT FWD END OF CREWS QTRS.
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Unknown
Issued 6 June 1996 Resolved
PROPERLY MARK HULL PER 46 CFR 185.602 (NEW T).
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Engineering
Issued 6 June 1996 Resolved
PROVIDE PROPER PRESSURE GAUGES FOR BOTH AIR RECIEVERS.
Condition: Unknown
Due 19 June 1996
Resolved 20 June 1996
Engineering
Issued 7 June 1995 Resolved
REPLACE WORN PORT RED GEAR LUBE OIL SUPPLY HOSE PRIOR TO 21JUN95.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Fire Fighting
Issued 7 June 1995 Resolved
PROVIDE A FIRE PUMP, ADEQUATE TO MEET THE REQUIREMENTS OF 46 CFR 181.10-1 PRIOR TO VESSEL OPERATION.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Lifesaving
Issued 7 June 1995 Resolved
PROVE OPERATION OF BOTH AIR RECEIVER RELIEF VALVES IAW 46 CFR 176.25-32 PRIOR TO 21JUN95.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Engineering
Issued 9 June 1994 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY SHOP TEST OF BOTH AIR RECEIVER RELIEFVALVES.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Construction/Loadline
Issued 9 June 1994 Resolved
INSTALL ONE ADDITIONAL POWER BILGE PUMP WITH A CAPACITY OF 50 GPM AS PER 46CFR 182.25-10 (a).
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Fire Fighting
Issued 9 June 1994 Resolved
PROVIDE ONE, B-II PORTABLE EXTINGUISHER PRIOR TO OPERATION OF THE VESSEL.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 9 June 1994 Resolved
RENEW BOTH FUEL LINES TO PORT GENERATOR WITH CG TYPE A HOSE.
Condition: Unknown
Due 17 June 1994
Resolved 21 June 1994
Navigation
Issued 9 June 1994 Resolved
INSTALL HEADED PINS IN STEERING RAM CONNECTION TO HULL MOUNTING.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 9 June 1994 Resolved
INSTALL 30X30 MESH FLAME SCREEN IN BOTH FUEL TANK VENTS.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Accommodation/Occupational Safety
Issued 9 June 1994 Resolved
INSTALL 30X30 MESH FLAME SCREEN IN MSD VENT AND RELOCATE VENT TERMINATION TO THE WEATHER DECK.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Lifesaving
Issued 9 June 1994 Resolved
REPAIR/REPLACE FOUR, 22 PERSON LIFE FLOATS. GRAB LINE STRAPS ROTTEN.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Lifesaving
Issued 9 June 1994 Resolved
PROVIDE ONE 30 INCH LIFE RING W/LINE PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 9 September 1993 Resolved
REPLACE 150 AMP GENERATOR BREAKER WITH UL LISTED 125 AMP BREAKER IN MAIN DISTRIBUTION PANEL.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Electrical
Issued 9 September 1993 Resolved
REINSTALL PROPERLY RATED (125 AMP) GENERATOR SELECTOR SWITCH IN MAIN ELECTRICAL PANEL.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Construction/Loadline
Issued 9 September 1993 Resolved
REMOVE ALL OIL FROM FORWARD VOID SPACE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Electrical
Issued 9 September 1993 Resolved
REMOVE ALL WIRING IN NEW INSTALLATION ON STERN AND SECOND DECK AREA AND SUBMITT PLANS FOR APPROVAL.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Electrical
Issued 9 September 1993 Resolved
CORRECT ALL OPEN RECEPTICLES AND PROPERLY DEAD END ALL WIRES.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Electrical
Issued 9 September 1993 Resolved
INSTALL DRIP PROOF COVERS ON BOTH ELECTRICAL PANELS IN THE AFT COMPARTMENT.
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Engineering
Issued 10 June 1993 Resolved
TIGHTEN SHAFT TO ENGINE COUPLING ON THE PORT MAIN ENGINE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 10 June 1993 Resolved
PROVIDE A SUITABLE RESCUE PLATFORM.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 10 June 1993 Resolved
BOTH PRESSURE VESSELS TO BE HYDROSTATICALLY TESTED TO 150 PERCENT OF THE MAWP IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 10 June 1993 Resolved
MAKE OPERABLE PILOT HOUSE CONTROL FOR STARTING AND STOPPING ALL MAIN ENG.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 10 June 1993 Resolved
INSTALL PROPER SIZE BOLT AND TIGHTEN ALL FOUNDATION BOLTS ON CENTER MAIN ENGINE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 29 June 1992 Resolved
STROBE LIGHTS SHALL NOT BE TURNED ON UNDERWAY. TO BE REMOVED FROM VESSEL.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Electrical
Issued 29 June 1992 Resolved
DECK LIGHTS FORWARD SHALL NOT BE ENERGIZED WHILE UNDERWAY.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Electrical
Issued 29 June 1992 Resolved
REMOVE ALL PORTABLE ELECTRICAL CORDS. ALL WIRING TO BE PERMANENTLY INSTALLED WITH SEPERATE BREAKERS IN AN APPROVED ELECTRICAL PANEL.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Lifesaving
Issued 10 June 1992 Resolved
REPLACE CLASS "A" EPIRB WITH FCC APPROVED CATAGORY I EPIRB PRIOR TO 01 JAN 1993.
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Fire Fighting
Issued 10 June 1992 Resolved
PROVIDE DOCUMENTATION FOR 6 YEAR SERVICE ON THREE DRY CHEMICAL EXTINGUISHERS.
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992
Lifesaving
Issued 10 June 1992 Resolved
REPLACE CLASS "A" EPIRB WITH FCC APPROVED CATAGORY I EPIRB PRIOR TO 01 JAN 1992.
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Navigation
Issued 13 June 1991 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Construction/Loadline
Issued 13 June 1991 Resolved
INSTALL RETAINING DEVICES ON ALL DECK HATCHES.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Electrical
Issued 13 June 1991 Resolved
REPLACE LAGGING ON STARBOARD GENERATOR EXHAUST.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Engineering
Issued 13 June 1991 Resolved
REPAIR FRACTURED WELD IN STBD, CENTER MUFFLER AT SIDE SHELL.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Accommodation/Occupational Safety
Issued 13 June 1991 Resolved
REMOVE OR PEPAIR THE AIR CONDITIONING UNIT AND HOT WATER HEATER IN THE GALLEY VOID SPACE.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Accommodation/Occupational Safety
Issued 13 June 1991 Resolved
INSTALL SOLID BULWARK OR EQUIVALENT ON ENTIRE UPPER DECK FROM THE DECK LEVEL TO THE UPPER RAIL COURSE.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Electrical
Issued 13 June 1991 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED SHUT DOWNS FOR BOTH S/S GENERATORS AND REPAIR AMMETER AND CYCLE METER IN SWITCHBOARD.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Electrical
Issued 13 June 1991 Resolved
RENEW ALL UPPER DECK 110VAC LIGHTING FIXTURES WITH UNITS APPROVED FOR MARINE SERVICE OR MEETING UL STANDARD 595.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Engineering
Issued 13 June 1991 Resolved
RENEW/PEPAIR RELIEF VALVES FOR BOTH AIR RECEIVERS AND PROVE PROPER OPERATION AT A PRESSURE BELOW THE MAWP OF 200 PSI. BENCH TEST CERTIFICATIONWILL BE ACCEPTED.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Navigation
Issued 20 December 1990 Resolved
REINSTALL SSB RADIO AND PROVE SATISFACTORY OPERATIONAL TEST PRIOR TO OPERATING WITH PASSENGERS MORE THAN 20 MILES FROM SHORE.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Engineering
Issued 6 June 1990 Resolved
REPLACE OR BLANK OFF HOLED FUEL TANK FILL PIPES IN ENGINE ROOM FOR THE AFTER MOST FUEL TANKS, PORT AND STARBOARD.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Navigation
Issued 6 June 1990 Resolved
WELD CRACKED AFT MOUNTING BRACKET FOR THE STEERING RAM, PORT SIDE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
REPAIR EXHAUST COOLING WATER LEAK AT FLEX HOSE FOR THE CENTER PIPE ON THE PORT SIDE IN THE ENGINE ROOM.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
REPAIR ENGINE OIL LEAK IN GAUGE LINE TO CENTER MAIN DIESEL ENGINE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Deck/Cargo
Issued 6 June 1990 Resolved
REPAIR LEAKING HYDRAULIC LINE TO BOW ANCHOR WINDLESS AND REMOVE OIL FROM FORWARD CREW SPACE AND FORE PEAK BILGES.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 6 June 1990 Resolved
INSTALL 30X30 MESH FLAME SCREEN ON MSD HOLDING TANK VENT, PORT SIDE FWD.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Navigation
Issued 6 June 1990 Resolved
BUILD-UP AND MACHINE OR RENEW THE BADLY WORN CLEVIS PIN IN THE PORT RUDDER ARM.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Electrical
Issued 6 June 1990 Resolved
REPAIR THE GENERATOR TRANSFER SWITCH ON THE MAIN SWITCHBOARD TO ALLOW MANAUL SELECTION OF S/S GENERATORS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Documentation
Issued 6 June 1990 Resolved
PROVIDE CURRENT FCC RADIOTELEPHONEY CERTIFICATE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Navigation
Issued 6 June 1990 Resolved
CORRECT SINGLE SIDE BAND RADIO TO OPERATE PROPERLY, VSL RESTRICTED TO NOT MORE THAN 20 MILES FROM SHORE UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Electrical
Issued 9 June 1989 Resolved
MAKE PROPER REPIAR TO BROKEN AIR START SOLINOID WIRE FOR STARBOARD MDE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 9 June 1989 Resolved
RENEW FLOAT FREE LINKS FOR ALL LIFE FLOATS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
REPLACE MISSING COVER FOR THE FIRE PUMP MOTOR CONTROLLER IN THE ENGINEROOM.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
REPAIR LEAK IN EXHAUST PIPE FOR S/S GENERATOR IN LAZARETTE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 9 June 1989 Resolved
V AND WELD CRACKS IN DECK HOUSE IN WAY OF STEPS TO WHEELHOUSE ON PORT AND STARBOARD SIDES.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
PROPERLY IDENTIFY ALL CIRCUIT BREAKERS IN ALL DISTRIBUTION PANELS THROUGH- OUT THE VESSEL.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
PROVIDE BLANK COVER FOR MISSING BREAKER IN POWER PANEL IN LAZARETTE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
REMOVE OR PROPERLY DEAD END ALL UNUSED WIRING IN BELOW DECK SPACES.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Engineering
Issued 9 June 1989 Resolved
INSTALL PROPER 30X30 MESH FLAME SCREEN ON STARBOARD FUEL TANK VENT.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Navigation
Issued 9 June 1989 Resolved
PROVE PROPER OPERATION OF INSTALLED SSB RADIO.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Accommodation/Occupational Safety
Issued 26 July 1988 Resolved
REMOVE RED AND GREEN SPOTLIGHTS FROM MAST.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Navigation
Issued 26 July 1988 Resolved
REPAIR STERN LIGHT. VESSEL RESTRICTED TO DAYLIGHT OPERATION TILL COMPLETED.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.