Records from 1999 to 2025. Most recent: inspection, 21 January 2025.
Inspection history · 37
21 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8071210
15 September 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8002687
30 August 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7992454
12 August 2024
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7985884
20 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7915602
17 May 2024
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7914316
12 June 2023
Examination of Repairs · MTSA/ISPS Verification · Construction Oversight · Inclining Experiment · ACP Handover Survey · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7712923
30 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6013176
5 October 2015
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5739705
6 August 2014
Drydock Exam
Physical examination · Activities Europe · Activity 4928992
2 May 2014
MARPOL Annex V Examination · MTSA/ISPS Verification · DAPI Audit · MARPOL Annex VI Survey · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 4856238
3 June 2012
Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 4279494
21 May 2012
DAPI Audit · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Activities Europe · Activity 4301752
21 May 2012
Type not recorded
No type recorded · Activities Europe · Activity 4317591
12 September 2011
DAPI Audit · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 4125577
10 November 2010
Deficiency Check
Physical examination · Activities Europe · Activity 3892961
3 July 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3226117
2 July 2007
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 2957939
27 September 2006
Annual Inspection
Physical examination · Activities Europe · Activity 2709050
14 February 2006
Administrative Inspection
Administrative · Activities Europe · Activity 2449752
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571459
5 May 2005
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2344905
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303652
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290173
3 February 2005
Damage Survey · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2285821
14 January 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2275164
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232610
28 June 2004
COI Inspection · Hull Examination · MTSA/ISPS Verification · Internal Structural Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2109488
4 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950216
29 August 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894490
18 August 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1880143
30 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1787649
9 July 2002
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1638239
3 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366447
18 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412140
21 October 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1132045
2 July 1999
Hull Examination · COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1423236
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 August 2024
Resolved
PAM # CG 1240083 has been modified fromoriginal approval by adding a FRP to the outside covering the vents. This covering is some type of fire retardent but it covers the automatic fire damper.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 12 August 2024
Resolved
Vessel has installed 3 PAM's on board, must have ABS certify tonage change and provide letter to CGMI.
705C - 7 days
Action required: 705 - Other - as specified
Due 27 August 2024
Resolved 19 August 2024
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 August 2014
No resolution recorded
The attending Marine Inspector should review that the new Fire & Safety Plan is correct. After review, the attending inspector should place CG stamp and date on the plan.
Condition: Invalid
Due 1 October 2016 — due date passed with no resolution recorded
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 2 May 2014
Resolved
MAKE PERMANENT REPAIRS, HOLES IN BOTTOM, TO THE RESCUE BOAT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: Received email showing the repairs were made and rescue boat report from shore side facility
Lifesaving › Rescue Boat Equipment › Bellows/Pump (inflated rescue boat)
Issued 2 May 2014
Resolved
ENSURE RESCUE BOAT HAS A FUNCTIONAL PUMP IN THAT HOSE FITTINGS ATTACHED TO THE FILL BLADDER IS CORRECT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: Received email with the rescue boat report from shore side facility
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 2 May 2014
Resolved
MAKE REPAIRS TO ENGINE MOUNT TO THE RESCUE BOAT IN THAT PREVENTIVE MEASURES ARE USED TO PREVENT GALVANIC CORROSION
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: Received email showing the repairs were made .
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 May 2014
Resolved
ENSURE YEARLY INSPECTION FOR THE RESCUE BOAT IS CONDUCTED
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: Received email with a rescue boat report from shore side facility
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 May 2014
Resolved
ENSURE CO2 INSTRUCTIONS FOR THE REMOTE PULLS ON THE BACK DECK NEAR THE GALLEY ENTRANCE HAS DIRECTIONS THAT MEET THE SYSTEM INSTALLED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: remote pulls found to meet the system installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 May 2014
Resolved
SHOW THAT THE CO2 SYSTEMS CAN FUNCTION WITHOUT DISCHARGING THE ENTIRE BANK OF BOTTLES TO EITHER THE BOW THRUSTER ROOM OR ENGINE ROOM WHEN ACTIVATED AND THE SYSTEM IS STILL ABLE TO FUNCTION FOR THE REMAINING PROTECTED SPACE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: The as been cleared pending ENG-4 input.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 May 2014
Resolved
UPDATE OR RENEW FIRE SAFETY PLAN TO REFLECT EQUIPMENT INSTALLED AND THAT THE GRAPHIC SYMBOLS MEET IMO RESOLUTION A.952(23). PLANS MUST BE REVIEWED AND APPROVED BY ABS OR THE COAST GUARD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 1 October 2014
Resolution: Plans have been submitted to ABS. New 835 entered into MISLE for following annual to inspect the Plan.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 2 May 2014
Resolved
ENSURE ALL EEBD'S ARE CHARGED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: EEBDs found to be properly charged.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2014
Resolved
ENSURE THAT THE MUSTER STATION HAS ILLUMINATION UNDER EMERGENCY POWER.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: Illumination for the muster stations has been placed under emergency power.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2014
Resolved
ENSURE THAT THERE IS SUFFICIENT ILLUMINATION THAT IS CONNECTED TO EMERGENCY POWER FOR THE RESCUE BOAT AND THE EMBARKATION AREA FOR THE LIFE RAFTS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: Sufficient illumination connected to the emergency power bus has been provided.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2014
Resolved
REPLACE LIFE RINGS THAT HAVE PLUGS THAT HAVE BEEN OPEN AND EXPOSED THE FOAM CORE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: Life rings noted above have been replaced
Communications › Radio Communications › Satellite Communications Capability
Issued 2 May 2014
Resolved
ENSURE GMDSS IS OPERATIONAL. UNTIL OPERATIONAL, THE VESSEL IS RESTRICTED TO VOYAGES LESS THAN 200 MILES FROM SHORE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: The GMDSS has been properly serviced by an approved FCC repair technician.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 May 2014
Resolved
ENSURE PRIMARY GYRO IS OPERATIONAL
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: Primary Gyro unit was replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 May 2014
Resolved
ENSURE THE OILY WATER SEPARATOR OIL CONTENT METER CAN BE CHECKED TO ENSURE THE SYSTEM WILL ALARM AND ACTIVATE AT 15PPM
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: The oily water separator content meter was found to be operational.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 May 2014
Resolved
ENSURE BATTERY FOR AIR COMPRESSOR IN THE CO2 ROOM IS PROPERLY MOUNTED IN A BATTERY BOX.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: The battery box was being manufactured at the shipyard and is scheduled to be installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2014
Resolved
ENSURE ALL EMERGENCY LIGHTS ARE PROPERLY IDENTIFIED WITH AN RED E
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: All emergency lights have been properly marked.
Fire Fighting › Fire Hoses › Condition
Issued 2 May 2014
Resolved
ENSURE ALL FIRE HOSES ARE PRESSURE TESTED TO 100 PSI
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: All fire hoses were removed from the vessel and tested at the shipyard to 100 psi.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 2 May 2014
Resolved
ENSURE SMOKE DETECTION SYSTEM IS TESTED
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 6 August 2014
Resolution: Smoke detection system was tested and found operational.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 21 May 2012
Resolved
Provide service report for #3 generator over-speed trip, low oil, low lube oil shutdown, high lube oil temperature and high jacket water temperature alarms after repairs have been facilitated.
Due 21 June 2012
Resolved 23 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Documentation › Logs/Records › Drug Test Records
Issued 21 May 2012
Resolved
Provide completed copy of DAPI audit.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 May 2012
Resolved
Complete annual thorough examination of the rescue boat to include in depth examination of the failing STBD sponson. If repairs are made, they shall be to the satisfaction of the manufacturer of the rescue boat.
Due 21 June 2012
Resolved 23 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 May 2012
Resolved
Provide EAP supervisor training for the master.
Due 21 June 2012
Resolved 20 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 May 2012
Resolved
Provide annual review of the SOPEP to the required USCG office iaw approval letter.
Due 21 June 2012
Resolved 24 May 2012
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 May 2012
Resolved
Provide report of periodic testing by a third party of the rescue boat davit and rescue boat hook. Ensure they are in accordance with the MFGR's tech manual using approved spare parts. Ensure that worn control cable is replaced.
Due 21 June 2012
Resolved 24 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 May 2012
Resolved
Provide annual proof of the USCG approved automation test procedure. Procedure on board has MSC letter but has never been verified by USCG OCMI with stamp for actual approval. Repair elements of the plan on hand are not able to be completed as written according to [name withheld] that load sharing failures void the conditions of Class DP1 annotation.
Due 21 June 2012
Resolved 12 July 2012
Resolution: Cleared during DD attendance by [name withheld].
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 21 May 2012
Resolved
Provide annual hydrostatic testing for fuel hoses
Due 21 June 2012
Resolved 12 July 2012
Resolution: Compleded during DD.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2012
Resolved
Provide emergency illumination for life raft and rescue boat plackards.
Due 21 June 2012
Resolved 15 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 21 May 2012
Resolved
Provide paint locker constructed of steel or be wholly lined with steel.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 May 2012
Resolved
Repair broken 9GHz port radar and troubleshoot backup 9GHz stbd radar.
Due 21 June 2012
Resolved 11 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 21 May 2012
Resolved
Repair gyro compass repeater.
Due 21 June 2012
Resolved 6 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Navigation › Piloting/Steering › Swing Meter
Issued 21 May 2012
Resolved
Repair failed port side rudder angle indicator for Z-drive.
Due 21 June 2012
Resolved 5 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 21 May 2012
Resolved
Repair bridge fire pump gauge.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Communications › Audible Communications › SPD (Other)
Issued 21 May 2012
Resolved
Repair loud hailer for aft deck.
Due 21 June 2012
Resolved 5 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 May 2012
Resolved
Provide service report for fire system maintenance and prove fixed alarms for installed CO2 system in the presence of a USCG Marine Inspector.
Due 21 June 2012
Resolved 12 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 21 May 2012
Resolved
Provide emergency lighting for egress from accommodations.
Due 21 June 2012
Resolved 15 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2012
Resolved
Install emergency illumination water light for liferafts.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Vessel Master provided email with proof to clear this item.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 September 2011
Resolved
Provide new hydrostatic release for EPIRB and install release properly.
Due 12 October 2011
Resolved 14 December 2011
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 September 2011
Resolved
Replace engine on the rescue boat with a Coast Guard approved rescue boat engine.
Due 12 October 2011
Resolved 14 December 2011
Lifesaving › Rescue Boat › Lifeline (becketed)
Issued 12 September 2011
Resolved
Repair hold ropes on the stbd side of the rescue boat that have been pulled free.
Due 12 October 2011
Resolved 6 October 2011
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 September 2011
Resolved
Provide proof that the annual automation tests are conducted in accordance with the approved autimation test procedures.
Due 12 October 2011
Resolved 12 October 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 September 2011
Resolved
Replace three (3) emergency backup betteries in the engine room
Due 12 October 2011
Resolved 6 October 2011
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 12 September 2011
Resolved
Provide lifesaving signals and helo recovery placard.
Due 12 October 2011
Resolved 12 October 2011
Communications › Visual Communication › Signalling Lamp
Issued 12 September 2011
Resolved
Provide a battery for the daylight signaling lamp on the bridge.
Due 12 October 2011
Resolved 30 October 2011
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 September 2011
Resolved
Provide a steel or steel lined paint locker prior to the completion of the next drydock.
Due 1 June 2012
Resolved 12 July 2012
Resolution: Cleared during annual Exam.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 September 2011
Resolved
Provide annual review letter for the Shipboard Marine Pollution Emargency Plan.
Due 12 October 2011
Resolved 19 September 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 September 2011
Resolved
Provide proof of ventilation closure and shutdown and sefvice report for next fixed fire extinguishing system service due in Oct 11.
Due 30 October 2011
Resolved 21 October 2011
Operations/Management › Drills/Instruction › Using Visual Distress Signals
Issued 12 September 2011
Resolved
Place general alarm placard "gereral alarm - when emergency alarm signal rings go to your station" in engine room at or near flashing lights.
Due 12 October 2011
Resolved 12 October 2011
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 September 2011
Resolved
Provide SOLAS eqress symbols 18 inches above the deck level throughout the vessel.
Due 12 October 2011
Resolved 12 October 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 July 2008
Resolved
Make permanent repairs to S/W leak on Z drive cooling pump suction piping.
Condition: Unknown
Due 19 August 2008
Resolved 23 August 2008
Engineering › Lubricating Oil Service System › Piping
Issued 3 July 2008
Resolved
Make proper repairs to L/O leak on main diesel engine water pump plates.
Condition: Improper/Lack of Maintenance
Due 19 August 2008
Resolved 23 August 2008
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 3 July 2008
Resolved
Make permanent repairs to jacket water cooling outlet piping on center main diesel engine.
Condition: Improper/Lack of Maintenance
Due 19 August 2008
Resolved 23 August 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 July 2008
Resolved
Make permanent repairs to salt water leak on stbd. zdrive cooling pump discharge piping.
Condition: Improper/Lack of Maintenance
Due 19 August 2008
Resolved 23 August 2008
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 3 July 2008
Resolved
Replace z drive room cooling duct in overhead where wasted.
Condition: Improper/Lack of Maintenance
Due 19 August 2008
Resolved 24 June 2009
Resolution: Cooling duct was satisfactorily repaired during 2009 dry-dock.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 3 July 2008
Resolved
Provide proof of annual servicing of the Rescue boat davit.
Due 19 August 2008
Resolved 23 August 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 August 2007
Resolved
Post operating instructions for manual release in the CO2 storage room (NFPA 12; 6-2.2.1). Reported as corrected by the vessel's captain by e-mail on August 9, 2007. Extended due date for complaince to October 1, 2008 (last day of anniversary window) so the next attending MI can verify.
Due 1 October 2008
Resolved 19 July 2008
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 4 August 2007
Resolved
Demonstrate proper operation of the prime movers over-speed, high jacket water and low lube oil safety devices. Reported as corrected by the vessel's captain by e-mail on August 9, 2007. Extended due date for complaince to October 1, 2008 (last day of anniversary window) so the next attending MI can verify.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2008
Resolved 19 July 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 July 2007
Resolved
Provide and maintain a CO2 fire extinguishing Instruction and Maintenance manual that includes a full sequence of operation, and a full set of accurate drawings (NFPA 12; 1-7.2.6). Reported as corrected by the vessel's captain by e-mail on August 9, 2007. Extended due date for complaince to October 1, 2008 (last day of anniversary window) so the next attending MI can verify.
Due 1 October 2008
Resolved 19 July 2008
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 2 July 2007
Resolved
Provide new compass deviation table. Reported as corrected by the vessel's captain by e-mail on August 23, 2007. Extended due date for complaince to October 1, 2008 (last day of anniversary window) so the next attending MI can verify.
Due 1 October 2008
Resolved 19 July 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 July 2007
Resolved
Demonstrate the proper operation of all fire dampers. Reported as corrected by the vessel's captain by e-mail on August 9, 2007. Extended due date for complaince to October 1, 2008 (last day of anniversary window) so the next attending MI can verify.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2008
Resolved 19 July 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 27 September 2006
Resolved
Provide evidence from manufacturer's service representative of proper test of main diesel engine, generator, and emergency generator safety tests: overspeed, low lube oil pressure, high H2O temperature alarms and shutdowns.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 3 November 2006
Resolution: Rcvd test report from Caterpillar; all sat.
Lifesaving › Buoyant Smoke Signals › General
Issued 27 September 2006
Resolved
Provide Coast Guard approved smoke signals on bridge wings. Item reported cleared via E-mail dated 13FEB07 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 4 August 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 September 2006
Resolved
Provide proof that all crewmembers are enrolled in a Drug & Alcohol testing program. 14FEB07: Extended the requirement becuase the company is negotiating a contract with International SOS.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 19 July 2008
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 27 September 2006
Resolved
Provide alcohol tester for testing within 2 hours of any marine incident.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 23 October 2006
Resolution: Rcvd email with copy of label from box of disposable testers.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 27 September 2006
Resolved
Prove proper operation of mimic control system; cargo and fuel level indicators are inaccurate. 14FEB07: Extended the requirement to give more time to determine the best course of action.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 19 July 2008
Stability › Watertight Integrity › General
Issued 27 September 2006
Resolved
Enable all watertight door indicators, and test to ensure accurate open/closed status in the pilot house. Do not allow indicators to be disabled. 23OCT06: Rcvd email from master - all indicators enabled and tested. Extended the due date to the end of the next annual window, so an inspector may verify that the indicators are not disabled at the next inspection.
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 4 August 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 27 September 2006
Resolved
Provide proper operation of Generator #1 auto mode. Item reported cleared via E-mail dated 14FEB07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 4 August 2007
Engineering › Bilge Water Management System › Piping
Issued 27 September 2006
Resolved
Provide documentation that the non-metallic piping in vital systems meets CG approval.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 23 October 2006
Resolution: Rcvd ABS type approval via email.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 27 September 2006
Resolved
Prove proper operation of aft Isis control station. 11JAN07: Received email from the master, via the port captain, stating that CG-835 #10 is complete. Extended the due date to the end of the next annual window, so an inspector may verify proper operation of the Isis system at the next inspection.
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 4 August 2007
Documentation
Issued 2 July 1999
Resolved
Provide on board for Coast Guard review, a valid ABS approved/issued Cargo Ship Safety Construction Certificate prior to engaging in International voyages.
Condition: Unknown
Due 2 August 1999
Resolved 14 March 2000
Documentation
Issued 2 July 1999
Resolved
Provide Technical/structural plan review w/ CG approval for the carriage ofNLS prior to engaging in International voyages.
Condition: Unknown
Due 2 August 1999
Resolved 22 September 1999
Documentation
Issued 2 July 1999
Resolved
Provide approval letter from MSC for the carriage of NLS Cargoes & provide a CG issued NLS Certificate.
Condition: Unknown
Due 2 August 1999
Resolved 22 September 1999
Documentation
Issued 2 July 1999
Resolved
Provide for CG review, an ABS approved Cargo Securing Manual in accordance w/ SOLAS 74(Amended) VI/5, prior to engaging in International Voyages.
Condition: Unknown
Due 2 August 1999
Resolved 22 September 1999
Documentation
Issued 2 July 1999
Resolved
Provide on board, an approved periodic test procedures operation manual forCG review.
Condition: Unknown
Due 2 August 1999
Resolved 14 March 2000
Documentation
Issued 2 July 1999
Resolved
Provide on board, a cargo record book, prior to engaging in International Voyages with NLS cargos IAW 46 CFR 125.120.
Condition: Unknown
Due 2 August 1999
Resolved 22 September 1999
Documentation
Issued 2 July 1999
Resolved
Provide training manual/aids on board for Coast Guard review IAW 46 CFR 131.530 and SOLAS (Amended) III, Reg 51.
Condition: Unknown
Due 2 August 1999
Resolved 14 March 2000