MAURY USCG vessel records Sign in
← All vessels

ZORRA

ZORRA is a 1976 towing vessel. The Coast Guard has recorded 49 inspections since 1984, most recently in November 1995, along with 43 deficiencies and 1 casualty investigation in 1995.

Records from 1984 to 1995. Most recent: inspection, 22 November 1995.

Built
1976
Last inspected
22 November 1995
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7391123 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WYH7202
Flag
UNITED STATES
—
Maury page id
psix-48970

Inspections, by type

…with no type recorded29
Years with a record 9 calendar years (1984–1995)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)141.4 ft × 54.0 ft × 22.5 ft
Registered tonnagegross 1,597 / net 1,086
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARYLAND SHPBLDG DRYDK CO · SLIDELL, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGUAYNABO, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 19 May 1994
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1597 - Regulatory (Subpart C or D), Gross Ton
1086 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WNJVMMSI not assigned · expired · compulsorily equipped · granted 6 November 1986, cancelled 6 November 1991 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ZORRA Freight Barge · MISLE 48904 · 9 July 1994 · activity 46045ZORRA Freight Barge · MISLE 48904 · 15 March 1994 · activity 57521PROASSIST II Towing Vessel · MISLE 65023 · 15 March 1994 · activity 57521PROASSIST I Towing Vessel · MISLE 65075 · 15 March 1994 · activity 57521

Inspection history · 49

22 November 1995 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1189696
1 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 681900
3 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 681901
24 April 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 73970
23 January 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 862031
14 July 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1177120
9 July 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 46045
11 May 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 701080
10 May 1994 Inclining Experiment · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1423924
15 March 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 57521
9 March 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 854330
4 March 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356544
3 March 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1164765
6 January 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851485
28 December 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 851519
4 November 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1153282
26 October 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 681897
5 October 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 681898
30 September 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366912
27 September 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 8072
27 September 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153459
22 September 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 165828
21 September 1993 Hull Examination · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1366894
13 September 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843858
9 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844598
2 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153805
30 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154481
8 June 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154476
8 June 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156632
29 December 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1231517
19 February 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1313771
2 February 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1025396
19 October 1987 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1019358
10 July 1987 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1325276
7 July 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1320485
2 July 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014672
1 July 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1321583
1 July 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1333253
4 August 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 999981
11 June 1986 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1310964
23 May 1986 Credit Drydock · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 998425
3 December 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 457621
22 November 1985 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294402
25 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977727
22 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 493066
1 February 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979047
14 January 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1284254
28 July 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 972757
18 June 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972748

Deficiency record · 43

Fire Fighting
Issued 14 July 1994 Resolved
Provide electrical diagrams for the newly installed 24 volt fire detection system to the local Officer in Charge Marine Inspection for approval.
Condition: Unknown
Due 21 September 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 10 May 1994 Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION SHOWING THE CURRENT OWNER.
Condition: Unknown
Due 15 May 1994
Resolved 16 August 1994
Lifesaving
Issued 10 May 1994 Resolved
Provide 16 additional ring buoys to bring total of ring buoys on board to 24 in accordance with 46 C.F.R. Subchapter I.
Condition: Unknown
Due 10 May 1994
Resolved 16 August 1994
Fire Fighting
Issued 10 May 1994 Resolved
Provide 4 additional B-II fire extinguishers to comply with the requirements of the COI.
Condition: Unknown
Due 10 June 1994
Resolved 16 August 1994
Engineering
Issued 30 September 1993 Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURES AND DEMONSTRATE OPERATION OF EQUIPMENT AS REQUIRED ON PAGES 9, 10, AND 11.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Accommodation/Occupational Safety
Issued 27 September 1993 Resolved
PROVIDE POTABLE WATER FOR VESSEL PRIOR TO DEPARTING SACRAMENTO.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Navigation
Issued 27 September 1993 Resolved
REPAIR HAND STEERING FUNCTION FOR STEERING GEAR, VESSEL NOT TO DEPART SACRAMENTO UNTIL SYSTEM IS CORRECTED AND TESTED BEFORE A MARINE INSPECTOR._x001C_
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Fire Fighting
Issued 21 September 1993 Resolved
Properly label all general alarms.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Engineering
Issued 21 September 1993 Resolved
Demonstrate operation of deadman alarm.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Engineering
Issued 21 September 1993 Resolved
Demonstrate operation of vital alarms in [name withheld] office._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Engineering
Issued 21 September 1993 Resolved
Provide Coast Guard approved Automation Test Procedures and demonstrate operation of equipment as required on pages 9,10 and 11.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Lifesaving
Issued 21 September 1993 Resolved
Provide a second oxygen/explosive meter for the fireman's outfit.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Lifesaving
Issued 21 September 1993 Resolved
Provide ring bouys capable of quick release from the bridge in accordance with 46 CFR 94.43-10(c).
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Documentation
Issued 21 September 1993 Resolved
Conduct stability test and provide revised trim and stability book, prior to the tug operating independently beyond the boundary line. _x001C_ ***SEE MINS ENTRY DATED 27SEP93 UNDER THIS CASE***
Condition: Unknown
Due 2 June 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 21 September 1993 Resolved
Demonstrate high exhaust temperature alarm.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Lifesaving
Issued 21 September 1993 Resolved
Properly label all liferaft stations.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Documentation
Issued 21 September 1993 Resolved
Provide Oil Transfer Procedures in accordance with 33 CFR 155.750.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Navigation
Issued 21 September 1993 Resolved
Provide compass deviation card.
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Construction/Loadline
Issued 30 July 1993 Resolved
PROVIDE MARINE SAFETY OFFICE SAN FRANCISCO BAY WITH FINAL, SMOOTH COPIES OFALL GAUGING REPORTS, STEEL SPECIFICATIONS, AND DIAGRAMS OF STEEL REPLACED DURING THE INTERNAL EXAMINATION COMPLETED 30 JULY 1993._x001C_ _x001C_
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Construction/Loadline
Issued 30 July 1993 Resolved
CLEAN DEBRIS FROM AROUND SUCTION BELLS IN #3 TANKS. TEST BILGE SUCTIONS.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Construction/Loadline
Issued 30 July 1993 Resolved
CLEAN ALL OIL FROM ENGINE ROOM BILGES AND MAKE AVAILABLE FOR EXAMINATION.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Lifesaving
Issued 30 July 1993 Resolved
REMOVE ALL WASTE OIL #3 STARBOARD BALLAST TANK. FLUSH TANK. DETERMINE WHERE OIL ENTERED TANK.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Construction/Loadline
Issued 30 July 1993 Resolved
FREE UP FOREPEAK BILGE LINE VALVE. RECONNECT REACH ROD AND PROVE PROPER OPERATION OF THIS SYSTEM.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Construction/Loadline
Issued 30 July 1993 Resolved
GAUGE ALL AREAS OF ENGINE ROOM AND NUMBER 3 TANKS UNDERNEATH THE PIG IRON. SUBMIT RESULTS OF THOSE GAUGINGS TO THIS OFFICE.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Engineering
Issued 19 February 1988 Resolved
PROVIDE SATISFACTORY OPERATION OF #12 VIDEO CAMERA AT ENGINEERS CONTROL.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Engineering
Issued 19 February 1988 Resolved
BYPASS GENISSIS FUEL METER UNTIL; A. PLANS ARE SUBMITTED TO THE USCG AND APPROVED, THE SYSTEM IS FUEL TIGHT AND FREE OF LEAKS, AND THE INSTALLATION TESING IS COMPLETE.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Fire Fighting
Issued 19 February 1988 Resolved
REPAIR OR REPLACE WEEPING DRESSER COUPLINGS ON BARGES FIRE MAIN, BY 3 NOV. 87 OR NEXT U.S. PORT WHICHEVER COMES FIRST
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Lifesaving
Issued 2 July 1987 Resolved
CONDUCT A BOAT DRILL USING THE PORT LIFEBOAT INVOLVING LOWERING THE BOAT TO THE WATER, RELEASING IT, OPERATING THE MOTOR, RETRIEVING AND RESTOWING THE BOAT.
Condition: Unknown
Due 2 July 1987
Resolved 2 July 1987
Engineering
Issued 1 July 1987 Resolved
MAKE OPERATIONAL THE HIGH BILGE LEVEL ENGINEROOM ALARM.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Engineering
Issued 1 July 1987 Resolved
MAKE OPERATIONAL ENGINEROOM RELAY CAMERAS FOR POSITIONS 4, 8, 9 & 11.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Engineering
Issued 1 July 1987 Resolved
MAKE OPERATIONAL THE PORT AND STARBOARD THROTTLE/ CLUTCH BRIDGE CONTROL AND RELATED GAUGES.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Engineering
Issued 1 July 1987 Resolved
THE HEAVY FUEL OIL GAUGES LOCATED ON THE CONSOLE AT THE LOWER LEVEL OF THE ENGINEROOM BETWEEN THE MAIN PROPULSION ENGINES MUST BE RENEWED AS ORIGINAL.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Unknown
Issued 1 July 1987 Resolved
ALL COMPRESSED GAS CYLINDERS UTILIZED FOR WELDING THAT ARE BEYOND THEIR FIVE TEAR HYDROSTATIC TEST DATE AS REQUIRED BY 46 CFR 147.04-1 MUST BE RENEWED
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Engineering
Issued 1 July 1987 Resolved
MAKE OPERATIONAL THE MAIN ENGINE EMERGENCY STOP AUTOMATION SIGNAL LIGHTS, I.E., AUTOMATION CONTROL CONSOLE YELLOW LIGHTS AND ROTATIONAL LIGHTS AND AUDIBLE ALARMS MUST ACTIVATE ACCORDING TO THE AUTOMATED TEST AND INSPECTIONPROCEDURES.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Documentation
Issued 1 July 1987 Resolved
ACQUIRE AND MAINTAIN ON THE BRIDGE A VESSEL INSPECTION RECORD CARD.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Accommodation/Occupational Safety
Issued 1 July 1987 Resolved
RESTOCK WITH NEW AS ORIGINAL THE VESSEL'S FIRST AID KIT.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Unknown
Issued 1 July 1987 Resolved
CLEAN DEBRIS AND RESTOW EQUIPMENT IN PROPER LOCATION, I.E., PAINT LOCKER, ALL GEAR IN THE PASSAGE WAY LOCATED BETWEEN THE STEERING GEAR ROOM AND THE MAIN ENGINEROOM.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Construction/Loadline
Issued 23 May 1986 Resolved
PRESENT PORT AND STARBOARD SEWAGE TANKS FOR INSPECTION AND PERFORM PERMANENT REPAIRS TO THE WASTED INTERNALS.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Construction/Loadline
Issued 23 May 1986 Resolved
PRESENT # 9 PORT BALLAST TANK FOR INSPECTION AND PERFORM PERMANENT REPAIRS TO THE WASTED INTERNALS
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Construction/Loadline
Issued 23 May 1986 Resolved
PRESENT # 9 STARBOARD BALLAST TANK FOR INSPECTION AND PERFORM PERMANENT REPAIRS TO THE WASTED INTERNALS.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Construction/Loadline
Issued 23 May 1986 Resolved
PRESENT # 10 PORT BALLAST TANK FOR INSPECTION AND PERFORM PERMANENT REPAIRSTO THE WASTED INTERNALS.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Construction/Loadline
Issued 23 May 1986 Resolved
PRESENT # 10 STARBOARD BALLAST TANK FOR INSPECTION AND PERFORM PERMANENT REPAIRS TO THE WASTED INTERNALS.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Documentation
Issued 14 January 1985 Resolved
PROVIDE A DUPLICATE SET OF FIRE CONTROL PLANS, STORED IN A PROMINENTLY MARKED WEATHERTIGHT ENCLOSURE OUTSIDE THE DECKHOUSE
Condition: Unknown
Due 14 January 1985
Resolved 14 January 1985

Casualty record · 1

24 April 1995Major Marine Casualty · role: Involved in a Marine Casualty · 1 injured · activity 73970
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record