MAURY USCG vessel records
← All vessels

CALIFORNIA DAWN

Built
1977
Last inspected
18 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB7239
Flag
UNITED STATES
Maury page id
psix-49125

Documentation record

Registered dimensions (L × B × D)48.7 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 36 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 12 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 78 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

18 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8327658
3 April 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100262
10 February 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8074081
23 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7917728
8 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7683946
21 March 2023 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655018
1 March 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7644063
13 January 2023 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7653833
14 April 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7430614
15 April 2021 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7175997
6 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166965
17 February 2021 Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141786
7 May 2020 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949714
2 March 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6919186
27 February 2019 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6633787
1 February 2019 Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618881
29 September 2018 Administrative Inspection · DAPI Audit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6611295
21 March 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6376260
20 April 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6127767
6 March 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6099487
28 January 2016 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5802818

Deficiency record · 78

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2026 Resolved
A power-driven vessel underway shall exhibit: Sidelights. MI identified loose wiring on starboard sidelight. 33 CFR 83.23(iii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 25 March 2026
Resolution: Received satisfactory photos of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 March 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI identified loose ladder in space under galley. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 25 March 2026
Resolution: Received satisfactory photo of repair.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 March 2026 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. MI identified no fire servicing record available. 46 CFR 176.810(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 13 April 2026
Resolution: Received firefighting equipment service report.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 April 2025 Resolved
A proper certificate issued by the Federal Communications Commission shall be regarded as evidence that the radio installation, if any, is in compliance with the requirements of that agency. Observed that the FCC Communications Safety Radio Telephony Certificate was expired. Replace the expired certificate with a valid certificate to satisfaction of the MI. (46 CFR 184.25-1(b)) [OLD T]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 16 April 2025
Resolution: Received photo of a valid, up-to-date FCC Communications Safety Radio Telephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-end wires found under helm console in bridge space. Remove dead-end wires from the space to satisfaction of the MI. (46 CFR 183.200)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 17 April 2025
Resolution: Received satisfactory photos of clean area under the console in bridge space.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Observed loose (red) wire connection on battery terminal in the engine room's port side, under "BOW" and "GALLEY" plate markings. Rectify loose connection to satisfaction of the MI. (46 CFR 183.350(d))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 3 April 2025
Resolution: Operator was able to securely tighten the loose connection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025 Resolved
Each ring life buoy on a vessel must be readily accessible. Observed life ring had minor tears, cracks, and missing a reflective tape on one corner. Repair or replace to the satisfaction of the MI. (46 CFR 180.70(b)(2))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 17 April 2025
Resolution: Received photo of satisfactory repairs for life ring. Retroreflective tape was added. Final (4th) strip of tape was to be inserted after the photo was sent.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025 Resolved
The water light must be: Attached to the life float or buoyant apparatus by a 12-thread manila or equivalent synthetic lanyard, at least 18 feet in length. Observed that the top lifefloat's water light line was brittle and sun-damaged. Rectify to satisfaction of the MI. (46 CFR 180.15-5 (d)(ii) [OLD T])
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 3 April 2025
Resolution: Operator was able to replace brittle water light line.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 April 2025 Resolved
A proper certificate issued by the Federal Communications Commission shall be regarded as evidence that the radio installation, if any, is in compliance with the requirements of that agency. Observed that the FCC Radio Station Authorization was expired. Deficiency was rectified on the spot. (46 CFR 184.25-1(b) (OLD T))
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: Valid station license provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025 Resolved
A vessel must carry one floating waterlight. Observed waterlight's battery was expired. Deficiency was rectified on the spot. (46 CFR 180.70 (d))
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: New battery installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025 Resolved
Paddles shall be lashed on the sides of the life floats to which they belong. Observed paddles weren't attached to life floats. Deficiency was rectified on the spot. (46 CFR 180.15-10 (a) [OLD T])
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: Paddles lashed to life float.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Observed missing light on a child's life jacket. Deficiency was rectified on the spot. (46 CFR 180.75(a))
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: New light installed on life jacket.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Observed switchboard at operating station missing one of its pieces. Deficiency was rectified on the spot. (46 CFR 183.200)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: Breaker blank installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Observed vessel had buckets that were larger than 2.5 gallons. Deficiency was rectified on the spot. (46 CFR 181.610)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 April 2025
Resolution: Holes drilled in buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of operation of the main propulsion machinery both ahead and astern. Vessel's stbd main engine is producing steam exhaust with unknown cause. Vessel operator to provide root cause and fix to the satisfaction of the cognizant OCMI. 46 CFR 176.804 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 29 October 2024
Resolution: Operator corrected deficiency to the satisfaction of MI, operator provided documentation of testing no issues identified.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 May 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected. The vessel's water lift muffler for the vessel's generator was not fully secured for sea. 46 CFR 176.830(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 29 October 2024
Resolution: Operator corrected deficiency to the satisfaction of MI, operator provided pictures of generator beinf properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2024 Resolved
Each ring life buoy must be marked with Type II retroreflective material. Vessel's ringbuoy is missing retroflective material. 46 CFR 185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 29 October 2024
Resolution: Operator corrected deficiency to the satisfaction of MI, operator provided picture of ring buoy tape add to ring buoy onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 May 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The vessel's hydrostatic release for the EPIRB was expired. 46 CFR 185.740 (b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 23 May 2024
Resolution: Operator replaced hydrostatic release for EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors. Fireboy system has been spliced with butt connections that showing exposed conductor. Make proper splice with marine grade connections that include heat shrink to satisfaction of attending Marine Inspector. 46 CFR 183.200(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 6 June 2023
Resolution: Verified new connection made and is not heat shrinked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Excessive amount of oil found in engine room bilge, under generator, on port engine turbo outlet, and on wiring on ceiling above generator. Additionally, fuel found on engine block on port engine inside of fuel filters. Clean engine compartment to satisfaction of the attending Marine Inspector. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 6 June 2023
Resolution: Engine room has been cleaned.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2023 Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Operator could not produce approved Lithium-Ion Battery Charging Plan and Marine Inspector could not confirm adherence to the plan. Make Plan available onboard vessel for inspection by attending Marine Inspector. 46 CFR 185.364
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Operator made new sign to hang on bulkhead.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 May 2023 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. There are two Masters with this Company that could not provide Marine Radio Operator Permits. 46 CFR 184.502: 47 CFR 80.159(e)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Verified readio permits for all masters.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2023 Resolved
Each life jacket carried on a vessel on an oceans route, must have a life jacket light… Each life jacket light must be securely attached to the front shoulder area of the life jacket. Marine Inspector found 16 lifejackets without functioning lights, operator replaced 10 lights, six life jackets remain outstanding. Vessel limited to 20 miles from shore. 46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Vessel now has all lifejackets with working lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspector found 16 lifejackets without serviceable lights and one with damaged kpok, vessel restricted to 35 persons onboard. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Vessel now has all lifejackets with working lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all machinery essential to the routine operation of the vessel. Vessel has a length of hose running internal on starboard side, passing through several bulkheads without a vapor tight barrier, that is unsecured and that owner could not identify. Identify hose and make proper installation to the satisfaction of attending Marine Inspector. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Hose was feering steering gear. Now secured.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 May 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Deck beam at midships on starboard side is showing signs of rot and needs to be repaired prior to credit drydock in 2025. 46 CFR 176.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: MI attended vessel to verify repairs. Vessel used "sistering" method to repair wooden support beam.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 May 2023 Resolved
The owner or managing operator shall make sure that maintenance is carried out in accordance with the instructions required under paragraph (a) of this section. One of the life floats has deteriorated beyond repair and is showing signs of cracking and waterlogging. Replace to satisfaction of attending Marine Inspector by 08JUL2023 or sooner. 46 CFR 185.702(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2023
Resolved 18 July 2023
Resolution: Inspected new life float installed on vessel. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not had drydock examination and has lapsed. Resolve prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2023
Resolution: Completed drydock examination.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with the manufacturer's instructions. Fireboy pressure is outside of proper operating parameters.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2022
Resolution: Verified fireboy servicing and pressure.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 April 2022 Resolved
A provision must be made for closing all supply duct cowls or scoops for a space protected by fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel had installed rubber flaps that were not effective in closing air supply from outside space. Submit plans for ventilation covers before making modifications or alterations.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2022
Resolution: Verified suitable vent closures onboard.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 14 April 2022 Resolved
Each collision bulkhead must extend to the weather deck. Collision bulkhead required by 171.040(b)(2) "Old T" is missing a watertight hatch, has multiple undressed penetrations, and does not extend up to the deck at port and starboard hull to deck joint.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 15 April 2022
Resolution: Verified corrections/closure to collision bulkhead.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 April 2022 Resolved
Each hatch cover must have securing devices. Engine room hatch does not have a way to secure it closed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 15 April 2022
Resolution: Verified securing hatch installed on engine room hatch.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 14 April 2022 Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80. Vessel has DSC capable radios that are incorrectly installed. Radios are not connect to GPS and are not loaded with MMSI. Make all radios capable of DSC operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 15 April 2022
Resolution: Verified MMSI number and radio capabilities.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 April 2022 Resolved
Each vessel that operates on the high seas (Outside 3nm) must have on board a FCC Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The hydrostatic release on EPIRB is expired. Restricted to voyages within 3 NM.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 15 April 2022
Resolution: Verified new hydro release installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 April 2022 Resolved
A weather tight door with permanent watertight coamings that comply with height requirements in Table 171.124 must be provided for each opening located in a deck house or companionway that gives access to the hull and is located in a well. Vessel has a vent for head that leads to an opening on outside of house that does not meet coaming height for route. Vessel is authorized a temporary plugging of opening. Permanent modification due prior to credit drydock. Submit plans before making alterations.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 21 March 2023
Resolution: Verified by attending Marine Inspector to meet height requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2022 Resolved
Each well deck on a vessel must be watertight. Vessel removed anchor windlass and has exposed bolt holes allowing water intrusion below the deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Holes on deck sealed with epoxy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition from flammable vapors. Lighting fixture over port engine is not properly secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Verified light fixture secured.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2022 Resolved
The marine employer must have sufficient number of alcohol testing strips readily accessible on board the vessel. Alcohol strips on board are expired.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Verified alcohol strips.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2022 Resolved
A vessel must carry a first-aid kit approved under approval series 160.41 or a kit with equivalent content and instructions. Vessel has several first-aid kits of which has expired medications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Verified contents of new first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Connections must be made to battery terminals with permanent type connectors. Temporary type clamps are prohibited. Vessel has wingnuts on most battery installations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Verified replacement of wingnuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2022 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy not less than 24 inches in diameter. Vessel has 20 inch life buoy. Replace with orange 24 inch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 15 April 2022
Resolution: Verified 24" buoy in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Each battery must be protected to protect against shifting with roll and pitch of the vessel. Plywood support structure under house batteries in the midships compartment are rotting. Repair prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2023
Resolution: Verified by attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2021 Resolved
A vessel on an oceans route must carry six red and six orange hand flares. 04 expired flares.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Operator replaced expired flares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2021 Resolved
A vessel not required to have a power driven fire pump must have three 2.5 gallon buckets labeled "FIRE BUCKET". Vessel has three 5 gallon buckets.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Operator punctured holes in bucket at the 2.5 gallon mark to allow egress of water if bucket is filled over 2.5 gallons.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 May 2020 Resolved
Vapor barriers must be provided where insulation of flammable and combustible liquids are present. The engine room had an unsealed penetration not allowing a sufficient vapor barrier. 46 CFR 177.405(e)
Action required: 10 - Deficiency Rectified
Due 7 May 2020
Resolved 7 May 2020
Resolution: The operator restored the vapor barrier with fire-retardent foam.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 March 2020 Resolved
Every vessel nsubject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installationh by an FCC-licensed technician every five years. U.S. vessels are exempt from provisions of title III, part III of the Communications Act that are less than 50 gross tons and navigated not more than 300 meters from the nearest land. Vessel's FFC documentation expired. Restricted to operations less than 300m (1,000ft) from shore. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2020
Resolved 7 May 2020
Resolution: Verified FCC Radio Safety Certificate is on board and valid.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. Bilge high level alarms have no audible sound. 46 CFR 182.530(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 March 2020
Resolved 7 May 2020
Resolution: Tested audible and visual bilge high level alarms to the satisfaction of the MI.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 2 March 2020 Resolved
Every vessel must have a detailed inspection of the radio installation by an FCC-licensed technician every five years. U.S. vessels are exempt from provisions of title III, part III of the Communications Act that are less than 50 gross tons and navigated not more than 300 meters from the nearest land. Vessel's FFC documentation expired. Restricted to operations less than 300m (1,000ft) from shore until rectified. 46 CFR 80.903 & 47 CFR 80.933
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 March 2020
Resolved 7 May 2020
Resolution: Verified current FCC Radio Safety Certificate onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 February 2019 Resolved
46 CFR 176.25-50 - At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. The Marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. The vessel had an excessive amount of oil in the engine room. The engine room bilge showed a large accumulation of oil and indications that the oil level was recently very much higher. The starboard engine showed excessive amounts of oil spatter and accumulation to indicate a leak or leaks are present. Vessel operator must determine causative factors for excessive oil in engine room and demonstrate to the satisfaction of the attending MI the vessel can operate without unsafe conditions or any hazardous situations onboard prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 February 2019
Resolved 8 April 2019
Resolution: Operator rectified the source of the oil leak in engine (dipstick unseating and causing backflow). Sea trial completed successfully, no visible leaks or concerns.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2019 Resolved
The Marine Inspector may conduct any such tests or inspections he or she deems necessary to be assured of the vessel's seaworthyness. During the inspection of potential oil pollution, MI identified numberous hazardous conditions that need to be evaluated in further detail. Vessel must undergo an annual inspection prior to the carriage of passengers for hire. 46 CFR 176.500
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2019
Resolved 8 April 2019
Resolution: Vessel completed sea trial with no deficiencies or issues witnessed.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 March 2018 Resolved
01 licensed member of crew not included on covered employees list IAW 46 CFR 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 21 March 2018
Resolution: Operator contact consortium representative and added crewmember to list IAW 46 CFR 16.
Engineering › Fuel Oil Service System › Filter
Issued 21 March 2018 Resolved
Starboard engine fuel filter requires shatterproof strainer bowl IAW 46 CFR 182.455(b)(6).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 21 March 2018
Resolution: Operator purchased and installed fuel filter strainer bowl IAW 46 CFR 182.455(b)(6).
Lifesaving › Hand Flares › Expired
Issued 21 March 2018 Resolved
02 hand flares expired and required IAW 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 21 March 2018
Resolution: Operator purchased 02 distress flares and installed onboard IAW 46 CFR 180.68.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 March 2018 Resolved
01 child-size PFD identified as unsatisfactory and required onboard IAW 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 21 March 2018
Resolution: Operator purchased new PFD and installed onboard IAW 46 CFR 180.71.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2017 Resolved
Provide proof of enrollment in a chemical testing program meeting DOT standards. 46 CFR 16.203
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 26 April 2017
Resolution: Vessel enrolled with ASTS with exp. date of 31DEC2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 April 2017 Resolved
Renew retro-reflective tape on vessel life floats. 46 CFR 160.027
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 26 April 2017
Resolution: Retro renewed
Engineering › Bilge Water Management System › Strainer
Issued 20 April 2017 Resolved
Clean strainer on bilge suction in hold immediately aft of the forepeak 46 CFR 185.25-1 "Old T"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 26 April 2017
Resolution: Pipe with pinhole slowed suction of system. Pipe renewed and system tested satisfactorily.
Engineering › Bilge Water Management System › Valve
Issued 20 April 2017 Resolved
Install valve handle on bilge system valve at collision bulkhead. Make valve easier to access.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 April 2017
Resolution: Valve replaced with new gate valve. hole cut in decking to allow easy access.
Construction/Loadline › Structures › Deck Plating
Issued 20 April 2017 Resolved
Repair/ Renew deck above aft starboard corner of engine room. Water noted beneath fiberglass deck. Check plywood deck for wood rot. 46 CFR 177.01-5 "Old T"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 26 April 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 April 2017 Resolved
Renew Retroreflective material on PFDs. Corrected on the Spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Corrected on the Spot
Lifesaving › Lifefloat › Float Free
Issued 20 April 2017 Resolved
Line connecting Lifefloat and weak link tangled enough to prevent deployment. Corrected on the spot.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Corrected on the Spot
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 27 March 2017 Resolved
Remove (1) B-II portable fire extinguisher from inside the engine room and mount outside of the respective space so as to be convenient to fight fire in the space protected.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Extinguisher moved to closet above Engine Room
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 23 March 2017 Resolved
Permanently mount sea strainers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: Sea strainers mounted
Engineering › Fuel Oil Service System › Hose
Issued 23 March 2017 Resolved
Remove non-type approved return fuel line to generator. Install type approved fuel line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: Replaced fuel hose with USCG Type A1 approved.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 March 2017 Resolved
Remove wing nuts from all battery terminals and install permanent type connectors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: Installed permanent fastener nuts
Engineering › Bilge Water Management System › Pump
Issued 23 March 2017 Resolved
Repair/replace bilge pump mounting bracket on port engine accessory drive belt and prove proper alignment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: Mounting bracket realigned and witnessed pulley operation with engine running.
Engineering › Bilge Water Management System › Not Operational
Issued 23 March 2017 Resolved
Prove proper operation of the fixed bilge system from all spaces
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 March 2017 Resolved
Inspect fire fighting systems and equipment by a certified inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: Fire systems and equipment serviced by licensed technician. Witnessed proper operation of Fir Boy shut downs and resets.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 March 2017 Resolved
Install a securing device to engine room hatch and prove water tightness.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: hatch secruing device installed
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 23 March 2017 Resolved
Perform sea trials to prove proper operation of newly installed engines
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Resolution: Sea trials conducted, full throttle 1800 rpm ahead and astern.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2017 Resolved
Remove or Terminate Dead End Wires in Engine Room.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Dead End Wires Removed
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 March 2017 Resolved
Install Hose Clamps on port engine sea water cooling hose at thru hull valve connection.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Hose clamps installed
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 23 March 2017 Resolved
Make bulkhead penetrations in engine room vapor tight to prevent escape of fire fighting system agent.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Penetrations made vapor tight
Electrical › Lighting (service) › Lighting Fixture
Issued 23 March 2017 Resolved
Remove engine room lighting fixtures and clean oil and dirt residue from inside ficture covers.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Light fixture covers cleaned and reinstalled
Construction/Loadline › Structures › Deck Plating
Issued 23 March 2017 Resolved
Remove rotted plywood covering main deck frames above main engines. (non-structural)
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Removed
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 23 March 2017 Resolved
Instal battery covers with ventilation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Covers installed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2017 Resolved
Remove or secure tool box on shelf located forward bulkhead directly above sea water cooling thru hull valves and engine accessroy drive belts.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Tool box removed
Engineering › Bilge Water Management System › Not Operational
Issued 23 March 2017 Resolved
Remove standing water and debris from all bilges and prove proper operation.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Debris and standing water removed. Bilges operated satisfactory

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.