07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 March 2025
Resolved
The fuel shut off valve must be operable from a safe place outside the space where the valve is installed. MI observed a temporary repair on the fuel shut offs in the Engine Room. 46 CFR 143.260 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 28 May 2025
Resolution: Operator displayed satisfactory actuation of fuel shut offs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 March 2025
Resolved
A hatch exposed to the weather must be watertight. MI observed worn gasket around the watertight seal of the lazarette hatch, compromising the watertight integrity.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: Operator provided photo of new gasket (see documents).
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 March 2025
Resolved
A vessel must carry six hand red flares and six orange smoke flares or 12 red hand flares. There were not flares onboard that were specific to the vessel. 46 CFR 169.553 (c ) (2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: Operator provided photo of new flares (see documents).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 27 March 2025
Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12. There was not a first aid kit onboard that was specific to the vessel. 46 CFR 199.175 (b) (10) (i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 28 May 2025
Resolution: First aid kit was replaced with a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 27 March 2025
Resolved
If a vessel operates on exposed or partially protected waters, it must have at least 100 percent of the freeing port area derived from table 171.150. Vessel was observed having installed custom freeing port grates, reducing drainage requirements, the day prior to the inspection and temporarily removed them prior to the inspection. Replace 04 aft plates permanently back to original design to meet drainage requirements.
46 CFR 171.150
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 April 2025
Resolved 27 March 2025
Resolution: Operator removed the freeing port grates in the presence of the MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2024
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing systems installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Vessel’s port engine was unable to start up after utilizing the override restart device. Vessel must diagnose the issue and repair the system to the satisfaction of the Marine Inspector.
46CFR181.420(b)(3)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2024
Resolution: Vessel operator was able to conduct a full override check of the port engine.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel’s fire detection system was not interconnected. Vessel is reduced to limited coastwise routes until detection system is interconnected.
46CFR181.405(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 April 2024
Resolution: Conducted def check fire detection system was tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024
Resolved
The exhaust pipe cooling water system shall be in accordance with the following provisions: (2) Water for cooling the exhaust pipe, other than a vertical exhaust, shall be injected into the exhaust system as near to the the engine manifold as practicable. The water shall pass through the entire length of the exhaust pipe. Vessel’s port wet exhaust system was found with a leak near the elbow joint. Vessel representative mentioned there was a similar issue on the stbd side. Repair the exhaust system to the satisfaction of the Marine Inspector.
46CFR182.15-15(b)(2) OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 18 July 2024
Resolution: Conducted required sea trial found exhaust repairs all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel was found with two unserviceable child lifejackets. Vessel must replace 2 child life jackets to the satisfaction of the Marine Inspector.
46CFR180.71(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 30 April 2024
Resolution: MI conducted def check found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
A vessel must have one or more ring life buoys as follows: (2) A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel’s life buoy was found deteriorated and cracked. Replace the life buoy to the satisfaction of the Marine Inspector.
46CFR180.70(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 30 April 2024
Resolution: MI conducted def check found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2024
Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Vessel was found with no securing device to the engine room hatch cover to the satisfaction of the Marine Inspector.
46CFR179.360(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Vessel submitted photograph of replaced securing device.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2024
Resolved
A hatch exposed to the weather must be watertight. The hatch leading to the lazarette was found with a worn gasket. Replace gasket to the satisfaction of the Marine Inspector.
46CFR197.360(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Submitted satisfactory photograph of replaced gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2024
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Vessels flares were found in a non-bright color container. Flares must be placed in a portable watertight container that is of bright color to the satisfaction of the Marine Inspector.
46CFR185.614
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Submitted satisfactory photograph of high visibility flares container.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 22 April 2024
Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include; (2) Padlocking each valve leading to an overboard discharge in the closed position;. Vessel was found with out a securing device to prevent untreated sewage from going overboard. Vessel representative installed a lock on the valve, correcting on the spot.
33CFR159.7(c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 April 2024
Resolved 22 April 2024
Resolution: Corrected on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 March 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was not present. Obtain valid certificate to the satisfaction of the marine inspector. 46 CFR 184.502
47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 8 May 2023
Resolution: Obtained certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 March 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Current MIS report was not present onboard. Obtain report and provide to the marine inspector. 46 CFR 16.260(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 22 June 2023
Resolution: Operator provided most recent MIS report.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 March 2023
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Operator could not provide proof of medical certificate. Provide proof to the satisfaction of the marine inspector. 46 CFR 15.401(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 22 June 2023
Resolution: Operator provided proof of compliance with medical certificate requirements
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 February 2023
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.450, if it is not a ferry, and if it - (2) is operating on a Coastwise or Oceans route. An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed...as meeting UL 217. Satisfactory video and photographs of installation have not been received. Route restricted to Limited Coastwise.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 March 2023
Resolution: Operator installed interconnected fire detectors. Detectors are located in engine room, under the access ladder in the aft corner of the cabin, and the cabin.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 August 2022
Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner, managing operator, or a representative thereof. Vessel was issued an 835 on 31MAR22 to provide repair proposal for structural modifications in lazarette. Discussed 835 details on 21JUN22 with owner and extended due date to 21JUL22. Owner failed to provide any details for structural modification.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2022
Resolved 5 August 2022
Resolution: Received letter from PE for acceptance of structure.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 July 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Light float attached to the ring buoy is inoperable and requires repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 6 July 2022
Resolution: recieved photographic proof of light replacement (see documents)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including inspection of each life jacket, work vest, and marine buoyant device. Kapok life jacket removed from service due to internal damage. Passengers permitted limited to 47 passengers until replacement life jackets are acquired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 July 2022
Resolution: Vessel replaced missing life jackets
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 July 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
Resolution: Line attached and buckets labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI... Vessel completed a full re-power without approval of OCMI. 46 CFR 176.700(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2022
Resolution: Vessel provided required documents and review of install completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2022
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. 46 CFR 176.700(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2022
Resolved 5 August 2022
Resolution: Extended to allow owner to provide structural plans.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every two years. Vessel did not complete required drydock inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
Resolution: Completed required drydock exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 8 June 2021
Resolved
If a vessel operates on exposed or partially protected waters, it must have at least 100 percent of the freeing port area derived from table 171.150. Vessel has installed custom freeing port grates reducing drainage requirements. Replace 04 aft plates back to original design to meet drainage requirements. 46 CFR 171.150
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2021
Resolution: Recieved photo with 04 aft freeing ports returned to orginal design grating.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. First aid kit contained expired burn cream. Replace with new.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2021
Resolution: Operator bought and placed new burn cream in first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2021
Resolved
Cork and balsa wood life jackets previously on board an existing vessel prior to March 11, 1996, may continue to be used to meet the requirements of this section until March 11, 1999, provided the life jackets are maintained in good and serviceable condition. Kapok life jacket not in good or serviceable condition. Removed from vessel, sufficient life jackets on board. 46 CFR 180.71(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Removed from service/destroyed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2021
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant... Retroreflective material missing for 01 life jacket. Removed from vessel.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Removed from service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2019
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every two years. Vessel did not complete required drydock inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: Vessel Completed Credit Dry Dock on 04MAR2020 at Svendsen's Bay Marine.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 June 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Operator failed to have vent closures onboard. Provide a proper means to close the engine room vents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2019
Resolved 13 June 2019
Resolution: Installed removable vent closures for engine room vents.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 June 2019
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for installation certificates to be issued by the FCC as set forth in 47 CFR Part 80. Operator did not have the safety radio certificate. Provide a copy of the certificate once received.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 9 July 2019
Resolution: Operator provided copy of the FCC safety certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019
Resolved
Each life jacket carried on a vessel on an oceans or coastwise route must have a life jacket light. Three adult and one child life jacket missing light. Attach
an approved light on all four life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and installed new lights on all four life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019
Resolved
Placards containing instructions for donning and use of
life jackets must be posted in conspicuous places that
are readily accessible and visible to crew and passengers. Life jacket placard was missing. Place new placard in a visible location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and mounted new life jacket placard.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 June 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. The placard was missing. Install new placard in the vicinity of the radio equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and mounted new emergency broadcast placard.
Engineering › Bilge Water Management System › Interface Detector
Issued 31 May 2018
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The high water level alarm visual indicator for the lazarette did not activate when tested.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 12 June 2018
Resolution: Vessel rep installed a new bilge alarm indicator. Inspectors witnessed satisfactory test.
Engineering › Fuel Oil Service System › Valve
Issued 31 May 2018
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. The protective shield surrounding the port side fuel tank shut off valve is wasted and the handle is exposed to the rest of the machinery space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 12 June 2018
Resolution: A new protective shield was installed on the vessel.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 31 May 2018
Resolved
An adult life jacket must be provided for each carried on board a vessel. Vessel was missing 3 lifejackets as required by the COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 12 June 2018
Resolution: Vessel rep landed 3 life jackets on the vessel.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 31 May 2018
Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Captain did not have MMC on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 12 June 2018
Resolution: Master presented MMC in person during the completion of the COI Inspection
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 May 2018
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery terminals found to be installed with wing nuts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 May 2018
Resolved 31 May 2018
Resolution: Crew removed wing nuts and installed permanent nuts on terminals.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018
Resolved
Complete annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2018
Resolved 12 June 2018
Resolution: COI Inspection was completed.
Communications › Radio Communications › EPIRB
Issued 11 April 2017
Resolved
Hydrostatic release on EPIRB was found to be expired. Vessel is restricted to less than 3 nautical miles until the hydrostatic release is replaced. - 46 CFR 180.64
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 14 April 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 April 2017
Resolved
Holes were found in the transverse bulkhead between the engine room and lazarette. Seal holes to make the bulkhead vapor tight. - 46 CFR "Old T" 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 27 October 2017
Resolution: Owner patched holes with wood to make space vapor tight.
Lifesaving › Lifefloat › Lifeline
Issued 11 April 2017
Resolved
An attachment point for one life float's lifeline was found to be ripped. Replace attachment point using approved jim buoy repair kit.
Condition: Improper/Lack of Maintenance
Due 11 May 2017
Resolved 31 May 2018
Resolution: During COI Inspection, life floats found in satisfactory condition.
Engineering › Bilge Water Management System › Hose
Issued 14 April 2016
Resolved
Replace Engine Room and Cabin Void electrical submersible bilge pump hoses with proper designed fit of good quality and substantial construction.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 14 April 2016
Resolution: Installed new hose of proper size and design to electrical submersible bilge pumps.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 April 2016
Resolved
Replace Engine Room bilge high level alarm cover at operators station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 15 April 2016
Resolution: Installed appropriate high level alarm cover
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016
Resolved
Provide first aid kit with items listed in Table 160.041-4(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 25 April 2016
Resolution: First Aid Kit purchased and onboard
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 April 2016
Resolved
Label number and size of life jackets in each storage container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 11 April 2017
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 April 2016
Resolved
Replace 03 PFD lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 22 April 2016
Resolution: Replaced 03 PFD lights
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2016
Resolved
Replace Mast and Anchor Nav lights. Limited to Day Time operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 11 April 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 February 2016
Resolved
Center Hatch on weather deck must be made watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Made hatch equivalent to watertight by installing latch, rubber gasket, and a drain in the seal channel to redirect water overboard. Design approved by [name withheld] Note added for future inspector reference.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 29 February 2016
Resolved
Make bulkhead penetrations (2) in Laz - E/R Bulkhead port side watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Penetrations made watertight.
Construction/Loadline › Structures › Superstructure
Issued 29 February 2016
Resolved
Make permanent repairs to port quarter deck rail (FRP) and port amidship rail (Wood).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Fiberglass repairs made to rails.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 February 2016
Resolved
Vessel shall complete dry dock inspection to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 29 February 2016