KINGFISH

KINGFISH is a 1965 passenger vessel (inspected). The Coast Guard has recorded 101 inspections since 1985, most recently in March 2025, along with 240 deficiencies and 9 operational controls, 1 with no removal date recorded.

Records from 1985 to 2025. Most recent: inspection, 27 March 2025.

Built
1965
Last inspected
27 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDK7381
Flag
UNITED STATES
368083880
Maury page id
psix-45035

Inspections, by type

…with no type recorded23
Years with a record 34 calendar years (1985–2025)
The 101 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.8 ft × 18.1 ft × 7.6 ft
Registered tonnagegross 51 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNOR'WESTER BOAT CO · MARYSVILLE, WA, UNITED STATES · built 1965
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 18 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7381MMSI 368083880 · active · compulsorily equipped · granted 27 March 2019, expires 27 March 2029
WDD2210MMSI 367112350 · expired · compulsorily equipped · granted 6 May 2006, cancelled 9 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCU3255MMSI 366739560 · expired · compulsorily equipped · granted 8 October 1997, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CALIFORNIA DAWN Passenger (Inspected) · MISLE 49125 · 23 November 2008 · activity 3369501GOLDEN EYE 2000 Passenger (Inspected) · MISLE 2992 · 30 January 2007 · activity 2864951KITTY KAT Passenger (Inspected) · MISLE 491213 · 30 January 2007 · activity 2864951

Inspection history · 101

27 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099638
22 April 2024 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899440
2 November 2023 Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7819303
15 March 2023 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7648578
20 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611568
1 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7522088
5 July 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7496907
13 June 2022 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7473721
31 March 2022 Deficiency Check · In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7422398
18 February 2022 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397301
6 December 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7363384
8 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7218326
17 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6927865
4 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6920410
13 November 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6855201
10 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6709824
30 May 2018 Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6429730
13 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6391155
26 October 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6295461
11 April 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6114361
14 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5854583
29 February 2016 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5824173
18 February 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5817409
23 February 2009 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3422590
23 November 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369501
1 October 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3336288
28 August 2008 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3304697
28 August 2008 Type not recorded
No type recorded · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3311505
20 June 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3242523
8 May 2008 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3202166
30 May 2007 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2915990
4 April 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2906900
22 February 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2876098
31 January 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2865594
30 January 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2864951
5 June 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2671336
22 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2655989
13 April 2006 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2622484
9 January 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2563569
3 January 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560110
21 July 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2415762
16 May 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2349263
26 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345955
20 April 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318784
14 April 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2285191
2 February 2004 Deficiency Check · Administrative Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1989985
20 March 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1752226
10 February 2003 Deficiency Check · Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1742480
5 November 2002 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1701225
7 November 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773099
4 October 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1074525
10 September 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772449
29 August 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389460
12 April 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772453
7 March 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1471596
31 August 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821033
30 August 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401307
23 September 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1033169
7 September 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378792
13 August 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1470990
31 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 6477
30 June 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 124500
8 March 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802358
2 September 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 797697
19 December 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 30303
24 September 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364376
17 September 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 782905
3 September 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375103
23 October 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1161320
10 October 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 841725
26 September 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357749
26 October 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 714402
30 September 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 181988
30 September 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 213064
30 September 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 217530
12 September 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377488
4 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843612
15 July 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154068
13 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155344
4 March 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834097
27 February 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948292
5 August 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251008
5 August 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251009
19 June 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917976
2 April 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 915651
4 March 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929801
7 February 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907355
24 May 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917065
3 April 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1215359
29 January 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1226929
8 February 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1033034
1 December 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207799
10 November 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1202441
23 November 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006558
24 July 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342381
4 February 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1316914
7 November 1986 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1321512
24 June 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995509
3 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984197
15 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981060
4 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976660

Deficiency record · 240

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 March 2025 Resolved
The fuel shut off valve must be operable from a safe place outside the space where the valve is installed. MI observed a temporary repair on the fuel shut offs in the Engine Room. 46 CFR 143.260 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 28 May 2025
Resolution: Operator displayed satisfactory actuation of fuel shut offs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 March 2025 Resolved
A hatch exposed to the weather must be watertight. MI observed worn gasket around the watertight seal of the lazarette hatch, compromising the watertight integrity. 46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: Operator provided photo of new gasket (see documents).
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 March 2025 Resolved
A vessel must carry six hand red flares and six orange smoke flares or 12 red hand flares. There were not flares onboard that were specific to the vessel. 46 CFR 169.553 (c ) (2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: Operator provided photo of new flares (see documents).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 27 March 2025 Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12. There was not a first aid kit onboard that was specific to the vessel. 46 CFR 199.175 (b) (10) (i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 28 May 2025
Resolution: First aid kit was replaced with a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 27 March 2025 Resolved
If a vessel operates on exposed or partially protected waters, it must have at least 100 percent of the freeing port area derived from table 171.150. Vessel was observed having installed custom freeing port grates, reducing drainage requirements, the day prior to the inspection and temporarily removed them prior to the inspection. Replace 04 aft plates permanently back to original design to meet drainage requirements. 46 CFR 171.150
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 April 2025
Resolved 27 March 2025
Resolution: Operator removed the freeing port grates in the presence of the MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2024 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing systems installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Vessel’s port engine was unable to start up after utilizing the override restart device. Vessel must diagnose the issue and repair the system to the satisfaction of the Marine Inspector. 46CFR181.420(b)(3)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2024
Resolution: Vessel operator was able to conduct a full override check of the port engine.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel’s fire detection system was not interconnected. Vessel is reduced to limited coastwise routes until detection system is interconnected. 46CFR181.405(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 April 2024
Resolution: Conducted def check fire detection system was tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024 Resolved
The exhaust pipe cooling water system shall be in accordance with the following provisions: (2) Water for cooling the exhaust pipe, other than a vertical exhaust, shall be injected into the exhaust system as near to the the engine manifold as practicable. The water shall pass through the entire length of the exhaust pipe. Vessel’s port wet exhaust system was found with a leak near the elbow joint. Vessel representative mentioned there was a similar issue on the stbd side. Repair the exhaust system to the satisfaction of the Marine Inspector. 46CFR182.15-15(b)(2) OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 18 July 2024
Resolution: Conducted required sea trial found exhaust repairs all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel was found with two unserviceable child lifejackets. Vessel must replace 2 child life jackets to the satisfaction of the Marine Inspector. 46CFR180.71(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 30 April 2024
Resolution: MI conducted def check found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024 Resolved
A vessel must have one or more ring life buoys as follows: (2) A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel’s life buoy was found deteriorated and cracked. Replace the life buoy to the satisfaction of the Marine Inspector. 46CFR180.70(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 30 April 2024
Resolution: MI conducted def check found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2024 Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Vessel was found with no securing device to the engine room hatch cover to the satisfaction of the Marine Inspector. 46CFR179.360(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Vessel submitted photograph of replaced securing device.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2024 Resolved
A hatch exposed to the weather must be watertight. The hatch leading to the lazarette was found with a worn gasket. Replace gasket to the satisfaction of the Marine Inspector. 46CFR197.360(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Submitted satisfactory photograph of replaced gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2024 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Vessels flares were found in a non-bright color container. Flares must be placed in a portable watertight container that is of bright color to the satisfaction of the Marine Inspector. 46CFR185.614
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 13 June 2024
Resolution: Submitted satisfactory photograph of high visibility flares container.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 22 April 2024 Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include; (2) Padlocking each valve leading to an overboard discharge in the closed position;. Vessel was found with out a securing device to prevent untreated sewage from going overboard. Vessel representative installed a lock on the valve, correcting on the spot. 33CFR159.7(c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 April 2024
Resolved 22 April 2024
Resolution: Corrected on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 March 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was not present. Obtain valid certificate to the satisfaction of the marine inspector. 46 CFR 184.502 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 8 May 2023
Resolution: Obtained certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 March 2023 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Current MIS report was not present onboard. Obtain report and provide to the marine inspector. 46 CFR 16.260(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 22 June 2023
Resolution: Operator provided most recent MIS report.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 March 2023 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Operator could not provide proof of medical certificate. Provide proof to the satisfaction of the marine inspector. 46 CFR 15.401(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 22 June 2023
Resolution: Operator provided proof of compliance with medical certificate requirements
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 February 2023 Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.450, if it is not a ferry, and if it - (2) is operating on a Coastwise or Oceans route. An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed...as meeting UL 217. Satisfactory video and photographs of installation have not been received. Route restricted to Limited Coastwise.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 March 2023
Resolution: Operator installed interconnected fire detectors. Detectors are located in engine room, under the access ladder in the aft corner of the cabin, and the cabin.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 August 2022 Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner, managing operator, or a representative thereof. Vessel was issued an 835 on 31MAR22 to provide repair proposal for structural modifications in lazarette. Discussed 835 details on 21JUN22 with owner and extended due date to 21JUL22. Owner failed to provide any details for structural modification.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2022
Resolved 5 August 2022
Resolution: Received letter from PE for acceptance of structure.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 July 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Light float attached to the ring buoy is inoperable and requires repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 6 July 2022
Resolution: recieved photographic proof of light replacement (see documents)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including inspection of each life jacket, work vest, and marine buoyant device. Kapok life jacket removed from service due to internal damage. Passengers permitted limited to 47 passengers until replacement life jackets are acquired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 July 2022
Resolution: Vessel replaced missing life jackets
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 July 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
Resolution: Line attached and buckets labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI... Vessel completed a full re-power without approval of OCMI. 46 CFR 176.700(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2022
Resolution: Vessel provided required documents and review of install completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2022 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. 46 CFR 176.700(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2022
Resolved 5 August 2022
Resolution: Extended to allow owner to provide structural plans.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every two years. Vessel did not complete required drydock inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
Resolution: Completed required drydock exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 8 June 2021 Resolved
If a vessel operates on exposed or partially protected waters, it must have at least 100 percent of the freeing port area derived from table 171.150. Vessel has installed custom freeing port grates reducing drainage requirements. Replace 04 aft plates back to original design to meet drainage requirements. 46 CFR 171.150
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2021
Resolution: Recieved photo with 04 aft freeing ports returned to orginal design grating.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. First aid kit contained expired burn cream. Replace with new. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2021
Resolution: Operator bought and placed new burn cream in first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2021 Resolved
Cork and balsa wood life jackets previously on board an existing vessel prior to March 11, 1996, may continue to be used to meet the requirements of this section until March 11, 1999, provided the life jackets are maintained in good and serviceable condition. Kapok life jacket not in good or serviceable condition. Removed from vessel, sufficient life jackets on board. 46 CFR 180.71(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Removed from service/destroyed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2021 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant... Retroreflective material missing for 01 life jacket. Removed from vessel. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Removed from service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2019 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every two years. Vessel did not complete required drydock inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: Vessel Completed Credit Dry Dock on 04MAR2020 at Svendsen's Bay Marine.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 June 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Operator failed to have vent closures onboard. Provide a proper means to close the engine room vents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2019
Resolved 13 June 2019
Resolution: Installed removable vent closures for engine room vents.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 June 2019 Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for installation certificates to be issued by the FCC as set forth in 47 CFR Part 80. Operator did not have the safety radio certificate. Provide a copy of the certificate once received.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 9 July 2019
Resolution: Operator provided copy of the FCC safety certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019 Resolved
Each life jacket carried on a vessel on an oceans or coastwise route must have a life jacket light. Three adult and one child life jacket missing light. Attach an approved light on all four life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and installed new lights on all four life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019 Resolved
Placards containing instructions for donning and use of life jackets must be posted in conspicuous places that are readily accessible and visible to crew and passengers. Life jacket placard was missing. Place new placard in a visible location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and mounted new life jacket placard.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 June 2019 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. The placard was missing. Install new placard in the vicinity of the radio equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 13 June 2019
Resolution: Purchased and mounted new emergency broadcast placard.
Engineering › Bilge Water Management System › Interface Detector
Issued 31 May 2018 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The high water level alarm visual indicator for the lazarette did not activate when tested.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 12 June 2018
Resolution: Vessel rep installed a new bilge alarm indicator. Inspectors witnessed satisfactory test.
Engineering › Fuel Oil Service System › Valve
Issued 31 May 2018 Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. The protective shield surrounding the port side fuel tank shut off valve is wasted and the handle is exposed to the rest of the machinery space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 12 June 2018
Resolution: A new protective shield was installed on the vessel.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 31 May 2018 Resolved
An adult life jacket must be provided for each carried on board a vessel. Vessel was missing 3 lifejackets as required by the COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 12 June 2018
Resolution: Vessel rep landed 3 life jackets on the vessel.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 31 May 2018 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Captain did not have MMC on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 12 June 2018
Resolution: Master presented MMC in person during the completion of the COI Inspection
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 May 2018 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery terminals found to be installed with wing nuts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 May 2018
Resolved 31 May 2018
Resolution: Crew removed wing nuts and installed permanent nuts on terminals.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2018 Resolved
Complete annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2018
Resolved 12 June 2018
Resolution: COI Inspection was completed.
Communications › Radio Communications › EPIRB
Issued 11 April 2017 Resolved
Hydrostatic release on EPIRB was found to be expired. Vessel is restricted to less than 3 nautical miles until the hydrostatic release is replaced. - 46 CFR 180.64
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 14 April 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 April 2017 Resolved
Holes were found in the transverse bulkhead between the engine room and lazarette. Seal holes to make the bulkhead vapor tight. - 46 CFR "Old T" 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 27 October 2017
Resolution: Owner patched holes with wood to make space vapor tight.
Lifesaving › Lifefloat › Lifeline
Issued 11 April 2017 Resolved
An attachment point for one life float's lifeline was found to be ripped. Replace attachment point using approved jim buoy repair kit.
Condition: Improper/Lack of Maintenance
Due 11 May 2017
Resolved 31 May 2018
Resolution: During COI Inspection, life floats found in satisfactory condition.
Engineering › Bilge Water Management System › Hose
Issued 14 April 2016 Resolved
Replace Engine Room and Cabin Void electrical submersible bilge pump hoses with proper designed fit of good quality and substantial construction.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 14 April 2016
Resolution: Installed new hose of proper size and design to electrical submersible bilge pumps.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 April 2016 Resolved
Replace Engine Room bilge high level alarm cover at operators station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 15 April 2016
Resolution: Installed appropriate high level alarm cover
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016 Resolved
Provide first aid kit with items listed in Table 160.041-4(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 25 April 2016
Resolution: First Aid Kit purchased and onboard
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 April 2016 Resolved
Label number and size of life jackets in each storage container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 11 April 2017
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 April 2016 Resolved
Replace 03 PFD lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 22 April 2016
Resolution: Replaced 03 PFD lights
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2016 Resolved
Replace Mast and Anchor Nav lights. Limited to Day Time operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 11 April 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 February 2016 Resolved
Center Hatch on weather deck must be made watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Made hatch equivalent to watertight by installing latch, rubber gasket, and a drain in the seal channel to redirect water overboard. Design approved by [name withheld] Note added for future inspector reference.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 29 February 2016 Resolved
Make bulkhead penetrations (2) in Laz - E/R Bulkhead port side watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Penetrations made watertight.
Construction/Loadline › Structures › Superstructure
Issued 29 February 2016 Resolved
Make permanent repairs to port quarter deck rail (FRP) and port amidship rail (Wood).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 14 April 2016
Resolution: Fiberglass repairs made to rails.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 February 2016 Resolved
Vessel shall complete dry dock inspection to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 29 February 2016
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 August 2008 Resolved
Prove proper operation of port fuel shut off valve.
Due 28 August 2008
Resolved 28 August 2008
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 August 2008 Resolved
Provide 3 new adult PFD's.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 August 2008 Resolved
Fix water lights on 7 adult PFD'sand 5 child PFD's.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 August 2008 Resolved
Prove proper operation of forward and aft steering bilge pumps.
Due 28 August 2008
Resolved 28 August 2008
Resolution: Rewired pumps and worked properly while on board.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 August 2008 Resolved
Repair wiring of aft steeering bilge alarm with proper connectors.
Due 28 August 2008
Resolved 28 August 2008
Resolution: Corrected on the spot.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Company policy missing as required by 46 CFR part 16.401.
Due 28 September 2008
Resolved 26 September 2008
Resolution: Company has final draft of their drug and alcohol policy.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Security of records not maintained in accordance with 49 CFR 40.333.
Due 28 September 2008
Resolved 29 August 2008
Resolution: Company''s drug and alcohol records are secured in a lock box.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 August 2008 Resolved
Properly labal bilge alarm panel.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Company did not have records of pre-employments as required by 46 CFR 16.210.
Due 28 September 2008
Resolved 25 September 2008
Resolution: All empoyee''s have records of pre-employment tests.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Evidence of statistically based method not currently being used to determine when random testing takes place as required by 46 CFR part 16.230.
Due 28 September 2008
Resolved 29 August 2008
Resolution: ASTS provided proof of company''s enrollment.
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 August 2008 Resolved
Properly labal emergency fuel shut off valves
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 28 August 2008 Resolved
Secure light fixture in engine room overhear.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
No evidence of testing spread equally throughout the year as required by 46 CFR 16.230
Due 28 September 2008
Resolved 29 August 2008
Resolution: ASTS provided proof of company''s enrollment.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240.
Due 28 September 2008
Resolved 25 September 2008
Resolution: Arrangement for post-casualty testing were made. Company''s consortium provide information for a mobile collection sight within the area.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Due 28 September 2008
Resolved 25 September 2008
Resolution: Company''s consortium provide testing devices.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 28 September 2008
Resolved 26 September 2008
Resolution: Company posted EAP program statement.
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 28 September 2008
Resolved 25 September 2008
Resolution: EAP hotline phone number posted for all employees.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 August 2008 Resolved
Double hose clamp hoses in engine room.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Documentation › Logs/Records › Drug Test Records
Issued 28 August 2008 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 28 September 2008
Resolved 29 August 2008
Resolution: ASTS submitted MIS report on behalf of the company.
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2008 Resolved
Tighten wire connected to starter on port engine.
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Conductor
Issued 28 August 2008 Resolved
Provide nuts to secure port side battery connections.
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 August 2008 Resolved
Remove deadend wires inengine room (for bilge alarm)
Due 28 August 2008
Resolved 28 August 2008
Resolution: Pulled old wires from engine room, corrected on the spot.
Personnel › Training › Ship's Business
Issued 28 August 2008 Resolved
Provide training, Man Overboard/Fire/EPIRB log.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 28 August 2008 Resolved
Provide locking mechanism for overboard MSD valve.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Construction/Loadline › Penetrations › Gasket
Issued 28 August 2008 Resolved
Properly fix hole between engine room and fwd compartment.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Lifesaving › Lifefloat › Paddle
Issued 28 August 2008 Resolved
Provide 2 paddles for stbd life float.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 29 August 2008
Resolution: Verified two new paddles on board.
Lifesaving › Lifefloat › Paddle
Issued 28 August 2008 Resolved
Properly secure paddles in life float.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 29 August 2008
Resolution: Verified both paddles are tied in life float.
Lifesaving › Lifefloat › Paddle
Issued 28 August 2008 Resolved
Mark vessels name on paddles. 46 CFR 185.604 (a)
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 29 August 2008
Resolution: Verified name on vsl on paddles.
Lifesaving › Lifefloat › Float-free Link
Issued 28 August 2008 Resolved
Provide weak link for portside life float.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 29 August 2008
Resolution: Verified new weak link of proper size for life float.
Lifesaving › Line-Throwing Appliances › Lines
Issued 28 August 2008 Resolved
Replace line on port side life ring light.
Due 28 August 2008
Resolved 28 August 2008
Lifesaving › Hand Flares › Storage
Issued 28 August 2008 Resolved
Provide proper stowage container for flares. 46 CFR 180.68 & 46 CFR 185.614
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Lifesaving › Emergency Outfit › Flashlight
Issued 28 August 2008 Resolved
Provide proper portable lighting. 46 CFR 183.430
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 August 2008 Resolved
Properly post emergency instruction list. 46 CFR 185.510
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 August 2008 Resolved
Prove proper operation of navigational lights.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 August 2008 Resolved
Remove dead ended wire beneath radar.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 28 August 2008 Resolved
Prove proper operation of compass light.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 August 2008 Resolved
Secure dead ended wires under bridge console.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 28 August 2008 Resolved
Remove "GOLDEN EYE" name from serial number sticker on EPIRB.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 August 2008 Resolved
Properly label PFD stowage.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 28 August 2008 Resolved
Secure aft flood lights.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Fire Fighting › Fire Bucket › Quantity
Issued 28 August 2008 Resolved
Provide 3 2.5 gallon fire buckets properly labeled.
Due 28 August 2008
Resolved 28 August 2008
Resolution: Corrected on the spot.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 August 2008 Resolved
Install chaffing gear on both raw water inlet hoses for both main engines.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 2 October 2008
Resolution: Corrected
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 June 2008 Resolved
Submit plans for re-power IAW 46 CFR 177.202
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2008
Stability › Severe Wind/Roll › General
Issued 20 June 2008 Resolved
Perform new Stability Test IAW 46 CFR 185.315.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 June 2008 Resolved
Prior to carrying passengers for hire complete a satisfactory Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2008
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
Repair locking mechanism in way of watertight hatch leading to engine room so it can properly secure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 September 2007 Resolved
Properly support wiring in engine room.
Due 6 October 2007
Resolved 2 October 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Pump
Issued 6 September 2007 Resolved
Bilge pump in forward compartment needs to be properly secured.
Due 6 October 2007
Resolved 2 October 2008
Resolution: Corrected
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 8 August 2007 Resolved
Vessel is restricted from carrying passengers for hire until the following items are satisfied: a. Complete COI exam. b. Submit plans for review/approval regarding new main engine installations and all associated vital systems, and include calculations on total vessel weight change. If total vessel weight change is greater than 2%, complete a new stability test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 February 2007 Resolved
Prove EAP training requirements are met for chemical testing program in way of crewmember training and supervisor's 1 hour EAP training.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 4 April 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 January 2007 Resolved
Provide proof of current enrollment with a drug testing consortium prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2007
Resolved 22 February 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2006 Resolved
Owner did not have the FCC Station License or FCC Safety Certificate readily available. Owner found the documents and faxed the documentation to Domestic Inspections office.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 3 May 2006 Resolved
Provide 11 lifejackets with required water lights.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Lifesaving › Lifefloat › Paddle
Issued 3 May 2006 Resolved
Provide to paddles required for life float.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Lifesaving › Lifefloat › Paddle
Issued 3 May 2006 Resolved
Properly label all four paddles required for life floats.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2006 Resolved
Replace batteries in all 3 water lights to ensure proper flotation.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2006 Resolved
Properly display an emergency broadcast placard on the bridge.
Action required: 705 - Other - as specified
Resolved 3 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 January 2006 Resolved
Complete Certificate of Inspection (COI) exam prior to carrying passengers for hire. COI de-activated 26 January, 2006.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 25 January 2006 Resolved
Renew Safety Radio Telephone Certificate.
Due 25 February 2006
Resolved 3 May 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 16 May 2005 Resolved
Provide proof that 50% of the crew has completed a CPR course.
Due 16 June 2005
Resolved 10 January 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 May 2005 Resolved
Provide proof that crew is enrolled in a random drug testing program.
Due 16 June 2005
Resolved 22 July 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 16 May 2005 Resolved
Post the emergency broadcast placard.
Due 16 June 2005
Resolved 10 January 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2005 Resolved
Provide proof of operation of the forward mast light. Vessel is restricted to day time operations.
Due 16 June 2005
Resolved 10 January 2006
Communications › Radio Communications › EPIRB
Issued 16 May 2005 Resolved
Provide proof of current EPIRB registration. Vessel is restricted to 3 NM from shore.
Due 16 June 2005
Resolved 10 January 2006
Communications › Radio Communications › EPIRB
Issued 16 May 2005 Resolved
Renew the EPIRB battery.
Due 16 June 2005
Resolved 10 January 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2005 Resolved
Install insulation on the exhaust piping for the port main diesel engine.
Due 16 June 2005
Resolved 21 July 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 16 May 2005 Resolved
Lubricate both emergency fuel shutoff valve cover.
Due 16 June 2005
Resolved 21 July 2005
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 16 May 2005 Resolved
Provide proof of FCC Marine Radio Operator Permit.
Due 16 June 2005
Resolved 21 July 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 May 2005 Resolved
Provide a service report for the fixed fire fighting system
Due 23 May 2005
Resolved 10 January 2006
Lifesaving › Lifefloat › Paddle
Issued 16 May 2005 Resolved
Label the paddles on the life floats.
Due 16 June 2005
Resolved 16 May 2005
Lifesaving › Lifefloat › Markings
Issued 16 May 2005 Resolved
Label the vessel's name and max capacity for the life float.
Due 16 June 2005
Resolved 16 May 2005
Fire Fighting › Fire Bucket › Quantity
Issued 16 May 2005 Resolved
Provide 3 fire buckets with lanyard and label each bucket "Fire Bucket"
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 16 May 2005
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 16 May 2005 Resolved
Provide proof of a senior deckhand letter IAW NVIC 1-91.
Due 16 June 2005
Resolved 16 May 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 16 May 2005 Resolved
Provide proof of operation of the engineroom bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2005
Resolved 16 May 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 April 2005 Resolved
Renew the cutlass bearing for both struts and the port forward support.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 26 April 2005
Construction/Loadline › Hull › Keel
Issued 20 April 2005 Resolved
Submit a repair proposal for the keel repair IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 26 April 2005
Construction/Loadline › Hull › Keel
Issued 20 April 2005 Resolved
Renew damage keel area IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 2 May 2005
Engineering › Steering Gear System › Linkage
Issued 20 April 2005 Resolved
Renew and align the steering linkages.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 16 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 April 2005 Resolved
Reseal the port exterior exhaust penetration.
Due 20 May 2005
Resolved 16 May 2005
Engineering › Bilge Water Management System › Valve
Issued 20 April 2005 Resolved
Install a metallic positive shutoff valve near the hull penetration for the electrical submersible pumps IAW 46CFR182.520(e)(7)
Due 25 January 2006
Resolved 25 January 2006
Construction/Loadline › Structures › Superstructure
Issued 20 April 2005 Resolved
Renew the FRP under the steering gear hydraulic ram.
Due 20 May 2005
Resolved 16 May 2005
Construction/Loadline › Structures › Superstructure
Issued 20 April 2005 Resolved
Submit a repair proposal for repair of FRP under the steering gear hydraulic ram.
Due 20 May 2005
Resolved 16 May 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 20 April 2005 Resolved
Renew the electrical connectors for the bilge pump and the bilge float switch.
Due 20 May 2005
Resolved 16 May 2005
Engineering › Steering Gear System › Bracket/Clamp
Issued 20 April 2005 Resolved
Properly secure the hydraulic hose for the steering system in the lazarette.
Due 20 May 2005
Resolved 22 July 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 April 2005 Resolved
Renew the port and starboard exhaust piping supports in the lazarette.
Due 20 May 2005
Resolved 10 January 2006
Construction/Loadline › Structures › Superstructure
Issued 20 April 2005 Resolved
Remove the furring in the engine room, void under the passenger accommodation space, and the void under the pilot house.
Due 20 May 2005
Resolved 21 July 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 April 2005 Resolved
Remove the welding cable and renew electrical conductors IAW 46CFR183.340.
Due 24 January 2006
Resolved 25 January 2006
Construction/Loadline › Structures › Superstructure
Issued 20 April 2005 Resolved
Properly secure the deck support IVO the port engine.
Due 20 May 2005
Resolved 26 April 2005
Stability › Watertight Integrity › General
Issued 20 April 2005 Resolved
Reseal the thru-hull fitting for the starboard exhaust drain.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 16 May 2005
Stability › Watertight Integrity › General
Issued 20 April 2005 Resolved
Properly cap the sea valve in the engine room on the port side.
Due 20 May 2005
Resolved 26 April 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 April 2005 Resolved
Repair the starboard exhaust leak. Remove the duck tape from the exhaust piping.
Due 20 May 2005
Resolved 2 May 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 20 April 2005 Resolved
Properly secured the fixed fire fighting piping located aft of the starboard engine.
Due 20 May 2005
Resolved 22 July 2005
Stability › Unintentional Flooding › General
Issued 20 April 2005 Resolved
Properly cap off the water tank located in the void under the passenger accommodation space.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 26 April 2005
Construction/Loadline › Structures › Superstructure
Issued 20 April 2005 Resolved
Properly secure the overhead deck support in the forepeak void.
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 26 April 2005
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 April 2005 Resolved
Make the port propeller key way ready for inspection.
Due 20 May 2005
Resolved 20 April 2005
Documentation › Certificates/Documents
Issued 2 February 2004 Resolved
Provide valid Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Documentation › Certificates/Documents
Issued 2 February 2004 Resolved
Provide valid radio Station License with new owner name.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Resolution: FCC will not issue a new station license since the existing license is currently valid. Requirement removed.
Documentation › Certificates/Documents › FCC SSL
Issued 2 February 2004 Resolved
Provide valid Radio Telephone Certificate with new owner name.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 21 July 2005
Stability
Issued 2 February 2004 Resolved
Post Stability Letter on board vessel.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Documentation › Certificates/Documents › Document of Compliance (dangerous goods)
Issued 2 February 2004 Resolved
Provide proof of updated Drug and Alcohol Audit and proof of random testing and company policy and EAP program. Proof of drug testing provided on 4/16/04. (KFK) Proof of EAP pending.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 May 2005
Lifesaving › Hand Flares
Issued 2 February 2004 Resolved
Provide applicable storage container for distress signals and label container "DISTRESS SIGNALS" LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Documentation › Logs/Records
Issued 2 February 2004 Resolved
Provide on board and show proof of updates and documentation of the following: Lifesaving Inspection Log, Drill & Crew Training Log, EPIRB Log.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Communications › Radio Communications
Issued 2 February 2004 Resolved
Renew expired hydrostatic release for EPIRB. Vessel is limited to within 3 miles from shore until requirement is completed. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Communications › Radio Communications
Issued 2 February 2004 Resolved
Show proof that EPIRB is properly registered. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 2 February 2004 Resolved
Replace one adult lifejacket and redo retro-tape on one child and one adult lifejacket. The passenger count is reduced to 42 adult and 4 child passengers until this requirement is completed.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 2 February 2004 Resolved
Show proof of proper operation of upper masthead light and forward masthead light. Proof of forward mast head light operation was witnessed on 3/25/04 RTW. Upper masthead light pends.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 May 2005
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 2 February 2004 Resolved
Provide on board: Updated Charts, Local notice to mariners.
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 10 January 2006
Navigation › Piloting/Steering
Issued 2 February 2004 Resolved
Provide on board: Updated Light list. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 February 2004 Resolved
Install a light for compass. Vessel is limited to daylight operations until this requirement is completed. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 February 2004 Resolved
Permanently attach fire extinguisher to the vessel or secure steps so the steps will not move when vessel is U/W. (the accomodation space extinguisher is attached to removeable steps) LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Engineering
Issued 2 February 2004 Resolved
Remove abandoned bait tank piping in way of port side engineroom.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Electrical
Issued 2 February 2004 Resolved
Remove abandoned wire in way of fwd bulkhead portside engineroom. (8" below overhead approximately 4"inboard)
Due 6 March 2004
Resolved 25 March 2004
Engineering
Issued 2 February 2004 Resolved
Double clamp bait tank pump discharge hose in way of fwd engineroom bilge.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Engineering
Issued 2 February 2004 Resolved
Remove abandoned piping and pump in way of port side engineroom fwd of port engine. Cap off valve.
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 25 March 2004
Engineering › Fuel Oil Service System
Issued 2 February 2004 Resolved
Label port and starboard emergency fuel cutoff remote handles. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Engineering › Bilge Water Management System
Issued 2 February 2004 Resolved
Repair / replace as original the lazarette bilge alarm. Restricted from carrying passengers until requirement is completed.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 16 April 2004
Engineering
Issued 2 February 2004 Resolved
Remove all oil from engineroom bilge. Restricted from carrying passengers until this requirement is completed.
Action required: 705 - Other - as specified
Due 6 March 2004
Resolved 25 March 2004
Engineering › Shafting/Propeller Arrangements
Issued 20 March 2003 Resolved
Replace forward and aft strut bearings on stbd propeller shaft, prior to credit for drydock. LEGACY COMPONENT DESC: Bearing
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 24 March 2003
Construction/Loadline › Hull
Issued 20 March 2003 Resolved
Reconnect port rub rail forward end , and seal up hull opening in aft end.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Construction/Loadline › Structures
Issued 20 March 2003 Resolved
Provide connecting device for flush deck hatch over lazarette. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 20 March 2003 Resolved
Reconnect aft muffler support bracket for port side exhaust in way of lazarette.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 March 2003 Resolved
Permanantly mount bilge alarm float switch in way of lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Construction/Loadline › Structures › Superstructure
Issued 20 March 2003 Resolved
Seal up forward and aft bulkheads of engineroom (vapor tight). LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 16 May 2005
Construction/Loadline › Structures
Issued 20 March 2003 Resolved
Treat furring wood in engine room overhead center line and forward of stbd engine overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 March 2003 Resolved
Provide covers for main engine starting batteries in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 21 July 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2003 Resolved
Clean up dead end wires and resupport all loose and dangling wires in cabin void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Construction/Loadline › Structures › End Bulkhead
Issued 20 March 2003 Resolved
Seal up holes in collision bulkhead in fwd peak (water tight).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Construction/Loadline › Structures › Scuttle
Issued 20 March 2003 Resolved
Replace gaskets on flush deck hatches for forward peak and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 24 March 2003
Stability
Issued 5 November 2002 Resolved
Conduct stability test and measurement for subdivision for upgrade to Oceans Route. LEGACY COMPONENT DESC: Stability Test
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Conducted simplified stability test. Vessel does not meet subdivision. Length in engine space exceeds 1/3 length of vessel.
Lifesaving › Lifejacket/PFD (General)
Issued 5 November 2002 Resolved
Provide waterlights for all lifejackets for upgrade to Oceans or Coastwise Route. LEGACY COMPONENT DESC: Lights
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Provided lights.
Lifesaving › Lifejacket/PFD (General)
Issued 5 November 2002 Resolved
Properly label lifejacket stowage with number of lifejackets. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 31 January 2003
Personnel › Manning/Qualifications
Issued 5 November 2002 Resolved
Provide current CPR/First Aid card for 50% of crew. Proof may be faxed. LEGACY COMPONENT DESC: First Aid Certified Personnel
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Provided current CPR/First Aid cards.
Documentation › Logs/Records
Issued 5 November 2002 Resolved
Provide proof of bridge log, training log, lifesaving equipment maintenance log. Proof may be faxed. LEGACY COMPONENT DESC: Logbook (official)
Due 5 February 2003
Resolved 31 January 2003
Navigation › Piloting/Steering
Issued 5 November 2002 Resolved
Provide proof of current coast pilot and light list for applicable areas. Proof may be faxed. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Provided current navigation publication.
Navigation › Piloting/Steering
Issued 5 November 2002 Resolved
Install light on magnetic compass prior to operating with passengers at night. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Installed light.
Communications › Radio Communications
Issued 5 November 2002 Resolved
Renew NOAA registration w/ new name. Proof may be faxed. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Proved current registration with NOAA.
Lifesaving › Lifebuoys
Issued 5 November 2002 Resolved
Repair as new orange ring life buoy.
Action required: 705 - Other - as specified
Due 5 February 2003
Resolved 24 February 2003
Resolution: Repaired life ring.
Construction/Loadline
Issued 10 September 2001 Resolved
SUBMIT PLANS FOR MAIN DECK REBUILD TO THE MARINE SAFETY OFFICE FOR REVIEW. IN ADDITION, MAKE THE EXISTING ENGINE ROOM HATCH WATERTIGHT AND CAPABLE OF BEING SECURED UNTIL PERMANENT WATERTIGHT REPAIR OR REPLACEMENT IS MADE.
Condition: Unknown
Due 28 November 2001
Resolved 31 January 2003
Resolution: Cleared previousely, but not documented.
Fire Fighting
Issued 29 August 2001 Resolved
NOT LATER THAN 28 SEP 2001, SERVICE ALL FIXED AND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Lifesaving
Issued 29 August 2001 Resolved
NOT LATER THAN 28 SEP 2001, REPLACE THE EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Lifesaving
Issued 29 August 2001 Resolved
UNTIL CLIPS ARE REPLACED ON THE TWO ADULT PFD's REJECTED AT THE INSPECTION FOR CERTIFICATION, THE MAXIMUM PERSONS ALLOWED ON BOARD IS LIMITED TO 42.
Condition: Unknown
Due 31 October 2001
Resolved 31 January 2003
Resolution: Cleared previously but not documented.
Construction/Loadline
Issued 29 August 2001 Resolved
NOT LATER THAN 28 NOV 2001, MAKE THE ENGINE ROOM HATCH WATERTIGHT AND CAPABLE OF BEING SECURED (46 CFR 179.360). UNTIL PERMANENT REPAIRS ARE MADE TO THE CENTERLINE ENGINE ROOM HATCH, TEMPORARY MEANS MUST BE PROVIDED FOR SECURING THE HATCH WHEN PASSENGERS ARE EMBARKED.
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Lifesaving
Issued 7 March 2001 Resolved
Total persons allowed reduced to twenty one after 11-Mar-01 until 100% lifefloats are provided and installed to the satisfaction of USCG Marine Inspector.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 30 August 2000 Resolved
REPLACE VALVE HANDLE ON SUCTION FOR BAIT TANK IN ACCORDANCE WITH 46 CFR 179.350(c).
Condition: Unknown
Due 30 September 2000
Resolved 6 September 2000
Navigation
Issued 30 August 2000 Resolved
POST EMERGENCY BROADCAST PLACARD IN ACCORDANCE WITH 46 CFR 184.506.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Fire Fighting
Issued 30 August 2000 Resolved
SERVICE FIXED CO2 FIRE EXTINGUISHING SYSTEM IN ACCORDANCE WITH 46 CFR 176.810(b)(2).
Condition: Unknown
Due 30 September 2000
Resolved 6 September 2000
Construction/Loadline
Issued 30 August 2000 Resolved
REPLACE GASKET ON HATCH LEADING TO STEERING COMPARTMENT IN ACCORDANCE WITH 46 CFR 179.360.
Condition: Unknown
Due 30 September 2000
Resolved 6 September 2000
Engineering
Issued 30 August 2000 Resolved
INSTALL RAYCOR FLAME IMPINGEMENT BOWL, PORT SIDE.
Condition: Unknown
Due 30 September 2000
Resolved 6 September 2000
Lifesaving
Issued 7 September 1999 Resolved
REPAIR/REPLACE RING BUOY WATER LIGHT.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Lifesaving
Issued 7 September 1999 Resolved
PROVIDE AND INSTALL A CATEGORY 1, 406 MHZ EPIRB. VESSEL IS RESTRICTED FROMOPERATING MORE THAN 3 NM FROM SHORE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Fire Fighting
Issued 7 September 1999 Resolved
PROVIDE MEANS FOR CLOSING ENGINE ROOM VENTS.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Construction/Loadline
Issued 13 August 1999 Resolved
Port rudder post pushed housing up into the FRP hull.
Condition: Unknown
Due 13 August 1999
Resolved 19 August 1999
Engineering
Issued 13 August 1999 Resolved
Port propellor was bent.
Condition: Unknown
Due 13 August 1999
Resolved 19 August 1999
Lifesaving
Issued 26 September 1996 Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Navigation
Issued 26 September 1996 Resolved
TIGHTEN BOTH RUDDER POST PACKINGS AND DEMONSTRATE WATERTIGHT INTEGRITY UNDERWAY.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Navigation
Issued 26 September 1996 Resolved
PROVIDE COPY OF LIGHT LIST.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Navigation
Issued 26 September 1996 Resolved
PROVIDE EMERGENCY RADIO BROADCAST PLACARD.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Construction/Loadline
Issued 26 September 1996 Resolved
RE-SEAL GASKET ON FOREPEAK HATCH.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Documentation
Issued 26 September 1996 Resolved
PROVIDE COPY OF OPERATOR'S FCC PERMIT.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Unknown
Issued 26 September 1996 Resolved
INCLUDE NAME AND ADDRESS OF MEDICAL REVIEWING OFFICER IN DRUG PROGRAM PACKAGE AS WELL AS TYPES OF DRUGS TESTED FOR.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Electrical
Issued 26 September 1996 Resolved
REPLACE BATTERIES IN LARGE FLASHLIGHT.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Lifesaving
Issued 12 September 1995 Resolved
PROVIDE ADEQUATE RESCUE EQUIPMENT (I.E. LIFELINES) IN EVENT OF PERSON OVERBOARD.
Condition: Unknown
Due 22 September 1995
Resolved 19 October 1995
Construction/Loadline
Issued 4 March 1991 Resolved
PROVIDE SECURING DEVICE FOR FLUSH DECK ENGINE ROOM HATCH.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
PROVIDE FLAME ARRESTERS FOR EMERGENCY FUEL SHUTOFFS AND MARK THE SHUTOFFS_x001C_ AS SUCH.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
REPLACE/REPAIR MECHANICAL BILGE PUMP.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
PROVIDE 2 FLAME SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Fire Fighting
Issued 4 March 1991 Resolved
PROVIDE EXTRA HOSE FOR SUCTION SIDE OF HAND FIRE PUMP. HOSE SHOULD REACH THE WATER LINE FROM ANY PART OF THE VESSEL.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Construction/Loadline
Issued 4 March 1991 Resolved
PROVIDE KEEPER CHAINS AND SECURING DEVICES FOR ENGINE ROOM HATCH COVERS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
PROVIDE MOUNTING FOR FUEL SHUTOFF COVERS IN WAY OF SAME.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Fire Fighting
Issued 4 March 1991 Resolved
SERVICE 1 BII AND 2 BI FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 29 January 1990 Resolved
SUBMIT PROPOSAL FOR FUEL TANK REPAIRS BY 12FEB90. COMPLETE REPAIRS TO FUEL TANK BY 28FEB90. HOLE IN TANK IS CURRENTLY COVERED WITH BONDO, AND THE BACKOF THE TANK APPEARS TO BE HEAVILY RUSTED, BUT WAS UNABLE TO INSPECT BECAUSEOF ITS LOCATION IN THE SPACE.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Engineering
Issued 29 January 1990 Resolved
REPAIR EXHAUST LEAK IN THE UPPER STARBOARD STACK AND REPAIR LAGGING THAT ISFALLING ON THE MAIN ENGINE AND INTO THE BILGES.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Engineering
Issued 29 January 1990 Resolved
TIE UP THROTTLE AND SHIFTING CABLES THAT ARE CURRENTLY LAYING IN THE BILGESAND LAYING ACROSS THE FRAMES.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Documentation
Issued 29 January 1990 Resolved
PROVIDE CURRENT COPY OF THE VESSELS DOCUMENT.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Construction/Loadline
Issued 1 December 1988 Resolved
MAKE WATER TIGHT, BOTH FORWARD AND AFT BULKHEADS IN WAY OF ENGINE ROOM.
Condition: Unknown
Due 1 December 1988
Resolved 1 December 1988
Construction/Loadline
Issued 1 December 1988 Resolved
INSTALL VALVES IN THROUGH HULL KEEL COOLER LINES.
Condition: Unknown
Due 1 December 1988
Resolved 1 December 1988
Engineering
Issued 24 July 1987 Resolved
PROVIDE FLAME PROTECTION FOR EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Engineering
Issued 24 July 1987 Resolved
REPAIR FUEL LEAK IN ENGINE ROOM PORT-SIDE.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Construction/Loadline
Issued 24 July 1987 Resolved
REMOVE FURRING IN ENGINE ROOM IN AREA OF BATTERY SELECTOR SWITCHES.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Documentation
Issued 4 February 1987 Resolved
HAVE FCC INSPECT & RENEW RADIO TELEPHONY & RADIO STATION LICENSE.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Construction/Loadline
Issued 4 February 1987 Resolved
REPLACE UPPER WOODEN SUPPORTS THAT ARE DRY ROTTED FOR PORT & STBD STACKS.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Navigation
Issued 4 February 1987 Resolved
REPLACE BOTH HYDRAULIC LINES & FITTINGS FOR STEERING SYSTEM IN LAZARETTE.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Construction/Loadline
Issued 4 February 1987 Resolved
REPAIR CRACKED TRANSVERSE FRAME IN VOID BENEATH CABIN LOCATED PORT SIDE MIDWAY.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Accommodation/Occupational Safety
Issued 4 February 1987 Resolved
REPLACE BOTH PORT & STBD 3" MSD OVERBOARD VALVES.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Documentation
Issued 24 June 1986 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Construction/Loadline
Issued 15 May 1985 Resolved
PROVIDE SUPPORT BLOCK FOR STBD SIDE FRAME IN LAZERETTE.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985

Ownership record