Records from 2009 to 2025. Most recent: inspection, 31 July 2025.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 July 2025
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. MI observed the public address system to be inoperable.
Cite: 46 CFR 184.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2025
Resolution: Public address system was observed to be operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2024
Resolved
Each vessel must be provided with safe,
readily available and sufficient firefighting
equipment of the type necessary
to extinguish any fires which
are likely to be encountered in normal
operation. Both of the vessels fire hose nozzles were not operating suffienciently for their continued use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel purchased new nozzles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
Propulsion machinery shall be
suitable in type and design for propulsion
requirements of the hull in which
it is installed and capable of operating
at constant marine load under such requirements
without exceeding its designed
limitations. Vessels steering hydraulic hoses were showing signs of chaffing. Vessel must install chaffing gear on all hoses that come into contact with frames or other hoses that may continue to wear down hoses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel installed chaffing gear on hydraulic hoses.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2024
Resolved
At each initial and subsequent inspection
for certification, reinspection
and at every other vessel inspection
the marine inspector shall require that
all observed unsafe practices and hazardous
situations be corrected. Vessels ventilation closure for the generator room would not secure properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel repaired vent closures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2023
Resolved
All vessels over 65ft. must have two bilge pumps. Vessels main bilge pump failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2023
Resolved 16 October 2023
Resolution: Witnessed sat test of bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 11 October 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear". Vessels emergency escape in aft steering needs to be re-stenciled IAW above.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 25 October 2023
Resolution: Vessel marked escape hatch appropriatly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 October 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears,
machinery, etc. Vessels stbd generator was missing a mach guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 16 October 2023
Resolution: Operator placed guard over moving mach.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Dead end wire found in aft steering near steering ram.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 16 October 2023
Resolution: Dead end wire was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
The alcohol testing of each individual engaged or employed on board the vessel within two hours of a Serious Marine Incident. Alcohol swabs not onboard. Provide sufficient alcohol swabs for maximum crew members. No transit permitted that cannot allow for alcohol testing within 2 hours of an SMI.
Action required: 705 - Other - as specified
Resolved 11 November 2022
Resolution: Photo provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
Marine Employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the ramdom chemical testing program. Updated list of crewmembers enrolled in Consortium was unavailable. Provide updated list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 October 2022
Resolved
A vessel must carry one floating waterlight. Floating waterlight battery is expired. Provide evidence of valid battery in waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: New light purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 October 2022
Resolved
Each vessel must have adequate emergency lighting. Emergency lighting was replaced. Remove old “emergency lighting stickers” from non-working lights. Provide photo evidence.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 15 November 2022
Resolution: Photo received.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 October 2022
Resolved
A berth must be provided for each passenger authorized to be carried in overnight accommodation spaces. Vessel is not authorized to carry overnight passengers. Remove mattresses from bunk rooms or request to add overnight accommodations to the vessel’s COI and comply with additional overnight regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 15 November 2022
Resolution: Photo received see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
The marine inspector must check the settings of the safety or relief valves on all pressure vessels annually. Relief valves dated back to 2020. Provide servicing report for both relief valves or provide proof of new purchase.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: All relief valved replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
Fuel shutoff valves must be fitted in fuel supply line to stop fuel flow. Weatherdeck shutoff does not indicate direction to stop fuel flow. Label shutoff direction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
All machinery and equipment must be maintained and installed in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Located machinery missing inspection cover and jacket water line making contact with shaft. Replace inspection cover and make changes as to prevent line contact with shafts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Corroded fuel vent: Each fuel tank shall be fitted with a vent pipe. Vent is completely corroded. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Exhaust Piping: shall be properly supported by non-combustible hangers or blocks. Replace hanger.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Generator Mount bolt missing: Aux machinery shall be suitable in type and design for the purpose intended. Replace missing bolt.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Bolt replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
Fuel filter mount: Shall be suitable in type and design for the purpose intended. Filter is loose. Secure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Filter secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 October 2021
Resolved
Engine room Water Tight Door: Each opeining in a watertight bulhead must have a means to close it watertight. Fix dogs on water tight door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Dogs tightened.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 20 October 2021
Resolved
Pin Hole Crack: Penetrations in wateright bulkhead must have means to make them watertight
46CFR171.114(a)(2)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: penetrations made watertight.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 October 2021
Resolved
Cracked Weld on Steering Ram: Main steering gear must have adequate strength and capable of steering the vessel at all speeds. Repair steering bracket.
46CFR182.610
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Steering bracket repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
Oil Pressure Gauge: All machinery is to be installed and maintained in such a manner as to afford adquate protection against fire, explosion, machinery failure and personnel injury. Oil pressure guage is leaking Oil. Repair or replace gauge.
46CFR182.01-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Gauge replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 20 October 2021
Resolved
Bulkhead Penetrations: Penetrations in wateright bulkhead must have means to make them watertight. Wires going through bulkhead are not watertight. Seal penetrations.
46CFR171.114
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Penetrations sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 October 2021
Resolved
Gauges to indicate engine cooling water discharge temp and lubricating oil pressure shall be provided for all propulsion engines. The wiring for the jacket water temperature gauge is exposed. Repair or replace wiring for gauge.
46CFR182.20-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 26 October 2021
Resolution: Wiring replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2021
Resolved
The stability letter must be posted under glass, or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. The stability letter is not posted. Post the must up to date stability letter.
46CFR176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Stability letter posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2021
Resolved
A vessel must carry one floating waterlight. The battery in the floating waterlight is expired. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Waterlight battery replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. A dead end wire was found in the battery box in the generator room. Remove dead ended wire.
46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Dead ended wire removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Generator Light Bracket broken: All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Repair or replace bracket.
46CFR183.01-15
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Bracket replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Electrical equipment used in machinery spaces must be drip proof. The battery charger in the generator space has no drip proof cover. Install a drip proof cover for the battery charger.
46CFR183.210
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Drip proof cover installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Outlet in head is broken: Electrical installations and equipment is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Replace electrical outlet.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Electrical outlet replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. The power available indicator light on the power distribution panel is extinguished. Repair/replace light.
46CFR183.01-15
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Light replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 October 2021
Resolved
Cracked Welds in steering room and engine room: hazardous situations must be corrected. Repair Welds
46CFR176.830
46CFR176.802
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Welds repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2020
Resolved
Vessel must have onboard required number of distress signals. Found 03 orange smokes expired. Replace smokes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Provided 3 new CG approved orange smokes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
Piping must be installed to prevent leaking or flooding. Found washing machine drain piping (PVC) joints not secured. Secure joints by acceptable means. Washing machine shall not be operated until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 September 2020
Resolution: Completed proper installation of washing machine discharge piping by using appropriate pvc glue/sealant.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2020
Resolved
Passenger vessels must have functioning emergency escape lighting from crew and passenger accomodation spaces. Found all installed emergency lighting inoperable. Repair emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2020
Resolution: Replaced blown fuse and defective electrical contact.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
Pressure vessel relief valves must be tested/calibrated annually. Found no servicing records for either pressure relief valves. Replace/test pressure relief valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Installed new and calibrated pressure relief valves on starobard and port ship service air pressure vessels.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Temporary clamps are not permitted on boattery connections. Make permanent connection on batteries in operating station and for generators.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Provided permanent type connections on battery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2019
Resolved
Watertight bulkhead penetration under accomodation space missing. Provide watertight fitting.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Installed watertight fitting on bulkhead penetration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 September 2019
Resolved
Holes present in weather deck. Weather deck must be watertight to prevent water entry
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Installed watertight bolt and washers to prevent water entry.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 September 2019
Resolved
High water alarm must have audio and visual indication. Vessel represetative corrected issue during the exam.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Dead end wire found under operating station and under galley space. Wire be removed or end in a junction box.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Ended dead wire ended in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Receptical outlet in aft engine room contains a broken groudning pole. Replace outlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Outlet replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2018
Resolved
Two bottom masthead lights were extinguished. Provide a complete set of working navigation lights IAW 46 CFR 183.420.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2018
Resolved 13 November 2018
Resolution: Vessel representatives provided photos of the functioning masthead lights. The photos have been uploaded in the documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
Fuel return piping was not properly secured for port and starboard main engines. Ensure fuel return piping is properly secured IAW 46 CFR 182.20-40(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
Flexible hose on fuel return system on port and starboard main engines was frayed and worn. Ensure the nonmetallic fuel piping is in good condition IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2018
Resolved
Engine room escape hatch was not properly secured to teh hatch coming. Provide an adequate means to keep hatch in place IAW 46 CFR 171.124(b)(2) [Old S].
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2018
Resolved
Lazarette escape hatch was not properly secured to the coaming and one of the hatch dogs was missing. Ensure that hatch is complete set of dogs and is secured to the coming IAW 46 CFR 171.124(b) [Old S].
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2018
Resolved
Multiple items in ship's first aid kit were expired. Provide in date replacements for expired items IAW 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 6 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2018
Resolved
Ring life buoy labeling was faded and unreadable. Provide appropriate labels on all ring life buoys IAW 46 CFR 185.30-5(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2018
Resolved
Grab lines on ring life buoys were worn and degraded. Provide new grab lines IAW 46 CFR 180.70(b)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 November 2018
Resolved
Smoke detectors throughout accomodation spaces were expired. Provide serviceable approved smoke detectors IAW 46 CFR 181.05-5(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 November 2018
Resolved
Emergency lighting in galley space was inoperable. Provide adequate emergency lighting in the galley space IAW 46 CFR 184.30-5(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 November 2018
Resolved
Port side railing lower two courses were missing and broken. Provide serviceable railings on the port side IAW 46 CFR 177.35-1(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2018
Resolved
FCC Radio safety and bridge-to-bridge certificates were expired. Provide renewed radio safety and bridge-to-bridge radio certificates IAW 46 CFR 184.502.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 November 2017
Resolved
Wires are loose and held up with zip ties, replace with metal supports in engine room and aft steering.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Cover was installed and metal ties were installed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 November 2017
Resolved
Electrical junction box, in the middle of the engine room, is missing its cover; replace cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Cover was reinstalled.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 2 November 2017
Resolved
Lagging is missing on starboard engine; replace missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 8 November 2017
Resolution: Lagging was reinstalled on exhaust manifold.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 November 2017
Resolved
Line is holding up generator exhaust, repair/replace with metallic supports
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Broken exhaust supports were cut out and replaced with chain supports.
Construction/Loadline › Penetrations › Gasket
Issued 2 November 2017
Resolved
Cable runs above fuel tank are missing packing; replace/renew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Old caulking was removed and replaced with new caulk.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2017
Resolved
Provide drug and alcohol paperwork with employees names
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Company provided documentation with all employees listed.
Lifesaving › Lifefloat › Serviceable
Issued 2 November 2017
Resolved
Life floats retro tape is worn and lines are deteriorated
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: New lines and reto-reflective tape was installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 November 2017
Resolved
Bilges have excess build up of corrosion, cleaned and make available for re-inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 8 November 2017
Resolution: Bilges were cleaned for inspection, UT shots were taken to identify level of deterioration.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 November 2017
Resolved
Emergency lighting was not working or lights were burnt out; replace bulbs or make operable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: New emergency lighting was installed and inspected satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 16 August 2016
Resolved
Starboard fire hose has two puncture holes. Replace fire hose with new hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Resolution: Owner replaced wasted hose with new.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 August 2016
Resolved
Distribution panel circuit breaker has broken toggle and missing labels. Replace toggle and label.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: Replaced broken breaaker and properly labeled panel.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 August 2016
Resolved
Port side switch board has broken indicator light. Replace with new light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: Replaced broken light.