Records from 1981 to 2025. Most recent: inspection, 31 July 2025.
Inspection history · 71
31 July 2025
Administrative Inspection · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8173852
3 November 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8028838
16 September 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8003565
25 September 2023
Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7798141
28 October 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7585102
31 August 2022
Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7548302
13 October 2021
Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7331841
17 July 2020
DAPI Audit · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7008647
1 July 2020
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7008151
5 September 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6804478
5 November 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575033
12 July 2018
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6476673
23 October 2017
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293591
23 March 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110194
2 August 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5960141
2 August 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5960148
29 June 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5923676
24 July 2015
DAPI Audit · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5194394
6 October 2014
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4994763
12 August 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4952523
21 March 2014
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 4821070
28 September 2011
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4156190
9 August 2011
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4110553
16 February 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3949771
29 March 2009
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3443221
27 March 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3441607
10 November 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3358296
19 August 2008
Hull Examination · Internal Structural Exam · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3302790
27 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3260278
13 February 2008
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147374
1 September 2006
Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2763379
7 September 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501147
9 September 2004
Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2191024
11 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1901147
4 September 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1670763
10 August 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464409
22 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056646
8 September 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439072
28 September 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1037051
19 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 123443
19 November 1998
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805192
18 September 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461078
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778746
25 August 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460977
22 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385796
22 August 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434295
8 August 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214173
8 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367136
30 July 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391886
2 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447197
26 August 1992
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960798
25 July 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1136038
23 June 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1264236
7 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676837
12 July 1991
COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249109
26 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244335
10 January 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238939
10 August 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901623
6 July 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930785
7 July 1989
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890411
9 June 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890123
25 January 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020032
5 June 1987
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1028184
15 May 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331912
20 May 1986
Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290967
3 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288354
22 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981050
23 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280441
21 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969487
15 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277535
16 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966801
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 July 2025
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. MI observed the public address system to be inoperable.
Cite: 46 CFR 184.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2025
Resolution: Public address system was observed to be operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2024
Resolved
Each vessel must be provided with safe,
readily available and sufficient firefighting
equipment of the type necessary
to extinguish any fires which
are likely to be encountered in normal
operation. Both of the vessels fire hose nozzles were not operating suffienciently for their continued use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel purchased new nozzles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
Propulsion machinery shall be
suitable in type and design for propulsion
requirements of the hull in which
it is installed and capable of operating
at constant marine load under such requirements
without exceeding its designed
limitations. Vessels steering hydraulic hoses were showing signs of chaffing. Vessel must install chaffing gear on all hoses that come into contact with frames or other hoses that may continue to wear down hoses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel installed chaffing gear on hydraulic hoses.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2024
Resolved
At each initial and subsequent inspection
for certification, reinspection
and at every other vessel inspection
the marine inspector shall require that
all observed unsafe practices and hazardous
situations be corrected. Vessels ventilation closure for the generator room would not secure properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: Vessel repaired vent closures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2023
Resolved
All vessels over 65ft. must have two bilge pumps. Vessels main bilge pump failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2023
Resolved 16 October 2023
Resolution: Witnessed sat test of bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 11 October 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear". Vessels emergency escape in aft steering needs to be re-stenciled IAW above.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 25 October 2023
Resolution: Vessel marked escape hatch appropriatly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 October 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears,
machinery, etc. Vessels stbd generator was missing a mach guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 16 October 2023
Resolution: Operator placed guard over moving mach.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Dead end wire found in aft steering near steering ram.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 16 October 2023
Resolution: Dead end wire was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
The alcohol testing of each individual engaged or employed on board the vessel within two hours of a Serious Marine Incident. Alcohol swabs not onboard. Provide sufficient alcohol swabs for maximum crew members. No transit permitted that cannot allow for alcohol testing within 2 hours of an SMI.
Action required: 705 - Other - as specified
Resolved 11 November 2022
Resolution: Photo provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
Marine Employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the ramdom chemical testing program. Updated list of crewmembers enrolled in Consortium was unavailable. Provide updated list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 October 2022
Resolved
A vessel must carry one floating waterlight. Floating waterlight battery is expired. Provide evidence of valid battery in waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: New light purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 October 2022
Resolved
Each vessel must have adequate emergency lighting. Emergency lighting was replaced. Remove old “emergency lighting stickers” from non-working lights. Provide photo evidence.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 15 November 2022
Resolution: Photo received.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 October 2022
Resolved
A berth must be provided for each passenger authorized to be carried in overnight accommodation spaces. Vessel is not authorized to carry overnight passengers. Remove mattresses from bunk rooms or request to add overnight accommodations to the vessel’s COI and comply with additional overnight regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 15 November 2022
Resolution: Photo received see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
The marine inspector must check the settings of the safety or relief valves on all pressure vessels annually. Relief valves dated back to 2020. Provide servicing report for both relief valves or provide proof of new purchase.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: All relief valved replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
Fuel shutoff valves must be fitted in fuel supply line to stop fuel flow. Weatherdeck shutoff does not indicate direction to stop fuel flow. Label shutoff direction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
All machinery and equipment must be maintained and installed in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Located machinery missing inspection cover and jacket water line making contact with shaft. Replace inspection cover and make changes as to prevent line contact with shafts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2022
Resolved 11 November 2022
Resolution: Photo provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Corroded fuel vent: Each fuel tank shall be fitted with a vent pipe. Vent is completely corroded. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Exhaust Piping: shall be properly supported by non-combustible hangers or blocks. Replace hanger.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2021
Resolved
Generator Mount bolt missing: Aux machinery shall be suitable in type and design for the purpose intended. Replace missing bolt.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Bolt replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
Fuel filter mount: Shall be suitable in type and design for the purpose intended. Filter is loose. Secure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Filter secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 October 2021
Resolved
Engine room Water Tight Door: Each opeining in a watertight bulhead must have a means to close it watertight. Fix dogs on water tight door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Dogs tightened.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 20 October 2021
Resolved
Pin Hole Crack: Penetrations in wateright bulkhead must have means to make them watertight
46CFR171.114(a)(2)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: penetrations made watertight.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 October 2021
Resolved
Cracked Weld on Steering Ram: Main steering gear must have adequate strength and capable of steering the vessel at all speeds. Repair steering bracket.
46CFR182.610
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2021
Resolved 25 October 2021
Resolution: Steering bracket repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
Oil Pressure Gauge: All machinery is to be installed and maintained in such a manner as to afford adquate protection against fire, explosion, machinery failure and personnel injury. Oil pressure guage is leaking Oil. Repair or replace gauge.
46CFR182.01-05
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Gauge replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 20 October 2021
Resolved
Bulkhead Penetrations: Penetrations in wateright bulkhead must have means to make them watertight. Wires going through bulkhead are not watertight. Seal penetrations.
46CFR171.114
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Penetrations sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 October 2021
Resolved
Gauges to indicate engine cooling water discharge temp and lubricating oil pressure shall be provided for all propulsion engines. The wiring for the jacket water temperature gauge is exposed. Repair or replace wiring for gauge.
46CFR182.20-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 26 October 2021
Resolution: Wiring replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2021
Resolved
The stability letter must be posted under glass, or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. The stability letter is not posted. Post the must up to date stability letter.
46CFR176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Stability letter posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2021
Resolved
A vessel must carry one floating waterlight. The battery in the floating waterlight is expired. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Waterlight battery replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. A dead end wire was found in the battery box in the generator room. Remove dead ended wire.
46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Dead ended wire removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Generator Light Bracket broken: All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Repair or replace bracket.
46CFR183.01-15
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Bracket replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Electrical equipment used in machinery spaces must be drip proof. The battery charger in the generator space has no drip proof cover. Install a drip proof cover for the battery charger.
46CFR183.210
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Drip proof cover installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
Outlet in head is broken: Electrical installations and equipment is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Replace electrical outlet.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Electrical outlet replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. The power available indicator light on the power distribution panel is extinguished. Repair/replace light.
46CFR183.01-15
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Light replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 October 2021
Resolved
Cracked Welds in steering room and engine room: hazardous situations must be corrected. Repair Welds
46CFR176.830
46CFR176.802
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2021
Resolved 25 October 2021
Resolution: Welds repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2020
Resolved
Vessel must have onboard required number of distress signals. Found 03 orange smokes expired. Replace smokes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Provided 3 new CG approved orange smokes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
Piping must be installed to prevent leaking or flooding. Found washing machine drain piping (PVC) joints not secured. Secure joints by acceptable means. Washing machine shall not be operated until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 September 2020
Resolution: Completed proper installation of washing machine discharge piping by using appropriate pvc glue/sealant.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2020
Resolved
Passenger vessels must have functioning emergency escape lighting from crew and passenger accomodation spaces. Found all installed emergency lighting inoperable. Repair emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2020
Resolution: Replaced blown fuse and defective electrical contact.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
Pressure vessel relief valves must be tested/calibrated annually. Found no servicing records for either pressure relief valves. Replace/test pressure relief valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Installed new and calibrated pressure relief valves on starobard and port ship service air pressure vessels.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Temporary clamps are not permitted on boattery connections. Make permanent connection on batteries in operating station and for generators.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Provided permanent type connections on battery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2019
Resolved
Watertight bulkhead penetration under accomodation space missing. Provide watertight fitting.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Installed watertight fitting on bulkhead penetration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 September 2019
Resolved
Holes present in weather deck. Weather deck must be watertight to prevent water entry
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Installed watertight bolt and washers to prevent water entry.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 September 2019
Resolved
High water alarm must have audio and visual indication. Vessel represetative corrected issue during the exam.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Dead end wire found under operating station and under galley space. Wire be removed or end in a junction box.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Ended dead wire ended in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Receptical outlet in aft engine room contains a broken groudning pole. Replace outlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Outlet replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2018
Resolved
Two bottom masthead lights were extinguished. Provide a complete set of working navigation lights IAW 46 CFR 183.420.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2018
Resolved 13 November 2018
Resolution: Vessel representatives provided photos of the functioning masthead lights. The photos have been uploaded in the documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
Fuel return piping was not properly secured for port and starboard main engines. Ensure fuel return piping is properly secured IAW 46 CFR 182.20-40(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
Flexible hose on fuel return system on port and starboard main engines was frayed and worn. Ensure the nonmetallic fuel piping is in good condition IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2018
Resolved
Engine room escape hatch was not properly secured to teh hatch coming. Provide an adequate means to keep hatch in place IAW 46 CFR 171.124(b)(2) [Old S].
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2018
Resolved
Lazarette escape hatch was not properly secured to the coaming and one of the hatch dogs was missing. Ensure that hatch is complete set of dogs and is secured to the coming IAW 46 CFR 171.124(b) [Old S].
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2018
Resolved
Multiple items in ship's first aid kit were expired. Provide in date replacements for expired items IAW 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 6 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2018
Resolved
Ring life buoy labeling was faded and unreadable. Provide appropriate labels on all ring life buoys IAW 46 CFR 185.30-5(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2018
Resolved
Grab lines on ring life buoys were worn and degraded. Provide new grab lines IAW 46 CFR 180.70(b)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 November 2018
Resolved
Smoke detectors throughout accomodation spaces were expired. Provide serviceable approved smoke detectors IAW 46 CFR 181.05-5(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 November 2018
Resolved
Emergency lighting in galley space was inoperable. Provide adequate emergency lighting in the galley space IAW 46 CFR 184.30-5(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 November 2018
Resolved
Port side railing lower two courses were missing and broken. Provide serviceable railings on the port side IAW 46 CFR 177.35-1(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2018
Resolved
FCC Radio safety and bridge-to-bridge certificates were expired. Provide renewed radio safety and bridge-to-bridge radio certificates IAW 46 CFR 184.502.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 27 November 2018
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 November 2017
Resolved
Wires are loose and held up with zip ties, replace with metal supports in engine room and aft steering.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Cover was installed and metal ties were installed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 November 2017
Resolved
Electrical junction box, in the middle of the engine room, is missing its cover; replace cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Cover was reinstalled.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 2 November 2017
Resolved
Lagging is missing on starboard engine; replace missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 8 November 2017
Resolution: Lagging was reinstalled on exhaust manifold.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 November 2017
Resolved
Line is holding up generator exhaust, repair/replace with metallic supports
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Broken exhaust supports were cut out and replaced with chain supports.
Construction/Loadline › Penetrations › Gasket
Issued 2 November 2017
Resolved
Cable runs above fuel tank are missing packing; replace/renew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Old caulking was removed and replaced with new caulk.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2017
Resolved
Provide drug and alcohol paperwork with employees names
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: Company provided documentation with all employees listed.
Lifesaving › Lifefloat › Serviceable
Issued 2 November 2017
Resolved
Life floats retro tape is worn and lines are deteriorated
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: New lines and reto-reflective tape was installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 November 2017
Resolved
Bilges have excess build up of corrosion, cleaned and make available for re-inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 8 November 2017
Resolution: Bilges were cleaned for inspection, UT shots were taken to identify level of deterioration.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 November 2017
Resolved
Emergency lighting was not working or lights were burnt out; replace bulbs or make operable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 6 November 2017
Resolution: New emergency lighting was installed and inspected satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 16 August 2016
Resolved
Starboard fire hose has two puncture holes. Replace fire hose with new hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Resolution: Owner replaced wasted hose with new.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 August 2016
Resolved
Distribution panel circuit breaker has broken toggle and missing labels. Replace toggle and label.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: Replaced broken breaaker and properly labeled panel.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 August 2016
Resolved
Port side switch board has broken indicator light. Replace with new light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 8 September 2016
Resolution: Replaced broken light.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 10 August 2015
Resolved
Life float weak link installed wrong, IAW 46CFR180.130
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Installed correctly.
Lifesaving › Lifebuoys › Approval
Issued 24 July 2015
Resolved
Two life bouys were worn and need replaced, IAW 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 24 July 2015
Resolved
Charts need updated or replaced, IAW 46CFR184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 July 2015
Resolved
Epirb monthly checks need to be logged, IAW 46CFR185.728
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Engineering › Fuel Oil Service System › Valve
Issued 24 July 2015
Resolved
F/O shut off valve for stbd tank needs replaced, IAW 46CFR182.20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Engineering › Steering Gear System › Motor
Issued 24 July 2015
Resolved
Steering pump guards need tightened, both are loose. IAW 46CFR182.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 24 July 2015
Resolved
Seating on below deck has a loose seat, needs repaired IAW 46CFR177.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Engineering › Feedwater/Condensate Water System › Valve
Issued 24 July 2015
Resolved
Water heater needs 100 psi safety valve installed, IAW 46CFR182.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Engineering › Lubricating Oil Service System › Gauge
Issued 24 July 2015
Resolved
Lube oil gauge for stbd gen needs replaced, IAW 46CFR182.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 July 2015
Resolved
Battery post need nuts and lock washers, also cleaned. IAW 46CFR183.350
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 July 2015
Resolved
Receptacle box in engine room needs replaced, IAW 46CFR183.340
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 July 2015
Resolved
Ventilation in engine room needs cleaned, IAW 46CFR182.20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 July 2015
Resolved
Emergency instructions not posted at helm, IAW 46CFR185.510
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 24 August 2015
Resolution: Deficiency corrected to the satisfaction of the Marine Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 6 October 2014
Resolved
Repair oil leak on #2 generator. Correct to 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2014
Resolution: Replaced oil psi sending unit.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 6 October 2014
Resolved
Repair hydraulic oil leak on #2 MDE. Correct to 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2014
Resolution: Repaired hydraulic oil leak.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 October 2014
Resolved
Bracket for electric water light behind operating station is loose. This must be secured in compliance with 46 CFR 161.010 per 46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 24 October 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2014
Resolved
Required first-aid kit contains expired aspirin and eye wash. This must be replaced in compliance with 46 CFR 160.041 per 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 24 October 2014
Resolution: Replaced expired meds.
Engineering › Pressure Vessel › Relief Valve
Issued 6 October 2014
Resolved
The pressure relief valve was set to 150 psi. This must be set to 100 psi or lower to be exempt from Subchapter F inspection per 46 CFR 182.320(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 24 October 2014
Resolution: Replaced with relief valve set at 100 psi.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2014
Resolved
Wiring to hydraulic motor is frayed and has improper connectors. This must be corrected to meet 46 CFR 183.10-20(a) and 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 24 October 2014
Resolution: Replaced with armored cable and correct connectors.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 9 August 2011
Resolved
Service or Renew top two lifefloats and the maximum total person allowed is reduced to 30
Due 23 September 2011
Resolved 29 August 2011
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 August 2011
Resolved
Poperly stencil all lifejackers w/ vessel name
Due 23 September 2011
Resolved 29 August 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 August 2011
Resolved
Properly label lifejacket stowage
Due 23 September 2011
Resolved 29 August 2011
Lifesaving › Lifefloat › Painter
Issued 9 August 2011
Resolved
Repair painter line spools for lifefloats
Due 23 September 2011
Resolved 29 August 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 August 2011
Resolved
Replace broken light mounting brackets as discussed
Due 23 September 2011
Resolved 29 August 2011
Fire Fighting › Fire Main › Condition
Issued 9 August 2011
Resolved
Repair valve handle & cap valve opening behind fire station # 10.
Due 23 September 2011
Resolved 29 August 2011
Fire Fighting › Nozzles › Condition
Issued 9 August 2011
Resolved
Replace chain for cap on navy all purpose nozzle at fire station # 9
Due 23 September 2011
Resolved 29 August 2011
Documentation › Certificates/Documents › FCC SSL
Issued 9 August 2011
Resolved
Provide current safety radio and bridge to bridge certificate IAW 47 CFR par 80
Due 23 September 2011
Resolved 7 September 2011
Communications › Radio Communications › EPIRB
Issued 9 August 2011
Resolved
Replace expired hydrostatic release for EPIRB
Due 23 September 2011
Resolved 29 August 2011
Communications › Radio Communications › EPIRB
Issued 9 August 2011
Resolved
Provide proof of registration for EPIRB
Due 23 September 2011
Resolved 29 August 2011
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 9 August 2011
Resolved
Remove all oil and oily rags from the bilge in the generator room
Due 23 September 2011
Resolved 29 August 2011
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 9 August 2011
Resolved
Replace wing nuts of sea strainer caps at stb and center engines
Due 23 September 2011
Resolved 29 August 2011
Engineering › Steering Gear System › Ram
Issued 9 August 2011
Resolved
Make repairs to steering mount and bed in lazarette
Due 23 September 2011
Resolved 29 August 2011
Electrical › Electric Generation Source (service) › Conductor
Issued 9 August 2011
Resolved
Properly support cabling in generator room
Due 23 September 2011
Resolved 29 August 2011
Construction/Loadline › Structures › Scuttle
Issued 19 August 2008
Resolved
Insure proper operations of water tight hatches in engine room and generator room and cabin watertight door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2008
Resolution: Hatches and doors adjusted to operate properly.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 August 2008
Resolved
Move existing smoke detector closer to berthing or place smoke detector in berthing area
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2016
Resolved 29 June 2016
Resolution: New smoke detector purchased and installed in berthing.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 August 2008
Resolved
Replace port side life ring light
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2016
Resolved 29 June 2016
Resolution: New float light purchased and installed on life ring.
Documentation › Logs/Records › Logbook (official)
Issued 19 August 2008
Resolved
Insure proper log entries made in accordance with 46 CFR
Due 21 August 2009
Resolved 7 August 2009
Resolution: Proper log entries maintained.
Communications › Public Address System › Loudspeaker
Issued 19 August 2008
Resolved
Add additional speakers to all manned spaces
Due 22 September 2008
Resolved 21 August 2008
Resolution: Speakers purchased and installed.
Documentation › Markings/Placards › Official Number (US)
Issued 19 August 2008
Resolved
Place hailing port on stern
Due 22 September 2008
Resolved 21 August 2008
Resolution: Name painted on stern
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 August 2008
Resolved
Install emergency lighting in generator room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2008
Resolution: New light was purchased and installed
Operations/Management › Drills/Instruction › Fire
Issued 19 August 2008
Resolved
Conduct fire drill upon arrival of crewmembers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2008
Resolution: Inspector conducted fire drill with all crewmembers present after examination of repairs.
Engineering › Fuel Oil Service System › Piping
Issued 7 September 2005
Resolved
Fuel leaks from the amidships and starboard main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2005
Resolution: Corrected.
Construction/Loadline › Structures › Door
Issued 7 September 2005
Resolved
Watertight door's gasket leading into engine room needs to be renewed/replaced.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2005
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Generator
Issued 7 September 2005
Resolved
Starboard service generator's armature saturated with oil and grime and in need of professional cleaning.
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 12 September 2005
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Fans
Issued 7 September 2005
Resolved
Engine room exhaust fan saturated with oil and grime and in need of professional cleaning.
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 12 September 2005
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 7 September 2005
Resolved
Port main diesel engine exhaust water cooling piping leaking at the exhaust connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2005
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2005
Resolved
Amidships main diesel engine exhaust water cooling piping leaking at the exhaust connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2005
Resolution: Corrected.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 September 2005
Resolved
Label generator room emergency escape scuttle.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 12 September 2005
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Switch
Issued 7 September 2005
Resolved
Label fuel and rig water controllers.
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 12 September 2005
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 September 2005
Resolved
Renew / replace starboard generator overspeed device.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2005
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 9 September 2004
Resolved
Renew one fuel line on port generator which was worn due to chafing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: New fuel hose installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 September 2004
Resolved
None of the emergency lights were labelled as such.
Action required: 705 - Other - as specified
Due 10 October 2004
Resolved 10 September 2004
Resolution: All emergency lights labelled.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 September 2004
Resolved
An emergency light in the rudder room did not have a cover.
Action required: 705 - Other - as specified
Due 10 October 2004
Resolved 10 September 2004
Resolution: Cover provided.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 9 September 2004
Resolved
Overspeed device on the port generator did not operate properly, it needs adjusting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Overspeed adjusted correctly.
Stability › Unintentional Flooding › General
Issued 9 September 2004
Resolved
The rudder room/engine room watertight bulkhead had a small hole in it where a box used to be installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Hole plugged and sealed with a bolt.
Lifesaving › Lifebuoys
Issued 11 September 2003
Resolved
Renew retro reflective tape on forward life ring. LEGACY COMPONENT DESC: Retro reflective Tape
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2003
Resolved 11 September 2003
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 September 2003
Resolved
Renew 05 lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2003
Resolved 11 September 2003
Electrical › Electric Generation Source (service)
Issued 11 September 2003
Resolved
Show proper operation of over speed device on starboard generator. LEGACY COMPONENT DESC: Over speed
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2003
Resolved 11 September 2003
Navigation › Piloting/Steering
Issued 4 September 2002
Resolved
Provide U.S. Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2002
Resolved 16 September 2002
Operations/Management › Drills/Instruction
Issued 4 September 2002
Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 4 September 2002
Resolved 16 September 2002
Communications › Alarms/Indicators
Issued 4 September 2002
Resolved
Repair tachometer in pilothouse for center main engine. LEGACY COMPONENT DESC: Tachometer
Action required: 705 - Other - as specified
Due 4 September 2002
Resolved 16 September 2002
Pollution Prevention/Response › Prevention Equipment
Issued 4 September 2002
Resolved
Provide proof of proper operation of oily water seperator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 4 September 2002
Resolved 16 September 2002
Engineering › Steering Gear System
Issued 4 September 2002
Resolved
Replace deteriorated hose. LEGACY COMPONENT DESC: Hydraulic Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2002
Resolved 16 September 2002
Engineering › Compressed Air System (start air)
Issued 4 September 2002
Resolved
Replace deteriorated hose to starter on stbd. main engine. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2002
Resolved 16 September 2002
Documentation › Certificates/Documents
Issued 4 September 2002
Resolved
Provide a FCC Safety Radio Certificate. LEGACY COMPONENT DESC: FCC Safety Radio Certificate
Action required: 705 - Other - as specified
Due 4 September 2002
Resolved 11 September 2003
Fire Fighting
Issued 8 September 2000
Resolved
DEMONSTRATE CREW DRILLS FOR FIREFIGHTING, MAN OVERBOARD, AND ABANDON SHIP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Engineering
Issued 19 November 1998
Resolved
MAKE STARBOARD SIDE FUEL TANK AVAILABLE FOR INSPECTION FOR POSSIBLE WASTAGEAND CORROSION IN WAY FRONT BOTTOM. ACCESS TO FUEL TANK SHOULD BE MADE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1998
Resolved 23 November 1998
Engineering
Issued 19 November 1998
Resolved
PROCEED TO SUPERIOR SHIPYARD, GOLDEN MEADOW, LOUISIANA TO MAKE PERMANENT REPAIRS TO PORT SIDE FUEL TANK FRONT BOTTOM.
Condition: Unknown
Due 13 December 1998
Resolved 23 November 1998
Electrical
Issued 30 July 1993
Resolved
PROVIDE ON BOARD AND PROPERLY INSTALL PROPER ENCLOSURE FOR CIRCUIT BREAKER/DISTRIBUTION PANEL LOCATED ON STBD SIDE FWD BHD OF GENERATOR ROOM, WITH PROPER LABELING AND PROVE PROPER OPERATION OF ALL CIRCUIT BREAKERS TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 17 August 1993
Resolved 17 August 1993
Documentation
Issued 26 April 1991
Resolved
PROVIDE ON BOARD A VALID DOCUMENTATION CERTIFICATE SHOWING THE PROPER OWNEROF THE VESSEL. [46CFR 67.23-3]
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Navigation
Issued 6 July 1990
Resolved
INSTALL PROPER BULBS IN NAVIGATION LIGHTS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Documentation
Issued 6 July 1990
Resolved
POST EMERGENCY CHECK-OFF LIST AS PER 46 CFR 185.25.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Deck/Cargo
Issued 9 June 1988
Resolved
REPAIR BROKEN/INOPERABLE PORT AND STBD FUEL OIL TANK VENTS.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Fire Fighting
Issued 9 June 1988
Resolved
REPLACE PRESSURE GAUGE ON ELECTRIC FIRE PUMP.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Deck/Cargo
Issued 9 June 1988
Resolved
LABEL BILGE SUCTION LINES AT MANIFOLD.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Lifesaving
Issued 9 June 1988
Resolved
NUMBER OF PASSENGERS PERMITTED IS REDUCED TO 52 (FIFTY-TWO) UNTIL A SUFFICIENT AMOUNT OF LIFEFLOATS ARE PROVIDED.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Navigation
Issued 9 June 1988
Resolved
MAKE REPAIRS TO PORT RUDDER QUADRANT SO THAT FREE MOVEMENT IS OBTAINED, ALSO ENSURE COTTER PINS ARE ATTACHED TO RETAINING BOLTS.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Electrical
Issued 9 June 1988
Resolved
SECURE ELECTRICAL CABLE AROUND AFT HATCHWAY (GOING FROM GEN RM TO ER) WITH 1/2 INCH METAL STRAPS.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Engineering
Issued 9 June 1988
Resolved
RENEW ALL BROKEN RETAINING BRACKETS ON L. O. TANK.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Construction/Loadline
Issued 25 January 1988
Resolved
GOUGE OUT AND RE-WELD CRACKS AT THE FOLLOWING; (1) THE 2ND & 3RD GUSSETS FROM THE BOTTOM ON STARBOARD STERN FRAME, AND (2) SECONDARY LONGITUDIAL FOREMERGENCY EXIT AT STERN. ALL CRACKS TO BE DRILLED TO PREVENT FURTHER PROPAGATION BEFORE REPAIRS CAN BE AFFECTED.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Accommodation/Occupational Safety
Issued 22 April 1985
Resolved
REPLACE VENT BALL CHECKS ON PORT AND STARBOARD
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Fire Fighting
Issued 22 April 1985
Resolved
REPLACE 50 FT. FIRE HOSE WITH ALUMINUM FITTINGS WITH APPROVED 1 1/2 INCH HOSE WITH BRONZE FITTINGS.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Engineering
Issued 22 April 1985
Resolved
REPLACE FLAME SCREENS ON PORT FWD F.O. TANK VENT AND STBD AFT F.O. TANK VENT.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Electrical
Issued 22 April 1985
Resolved
PROPERLY MOUNT FREQUENCY METER ON MAIN SWITCHBOARD.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Electrical
Issued 22 April 1985
Resolved
REPLACE SHORE POWER AVAILABLE LIGHT ON MAIN SWITCHBOARD.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Electrical
Issued 22 April 1985
Resolved
REPAIR/REPLACE BATTERY BOX FOR #2 SS GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Fire Fighting
Issued 22 April 1985
Resolved
REPLACE MULTIPLE ORIFICE HIGH VELOCITY FOG NOZZLE TIPS WITH APPROVED SINGLEORIFICE TIPS IN ACCORDANCE WITH 46 CFR 181.15-10(D)(2)
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985