HURRICANE II

HURRICANE II is a 1977 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2025, along with 25 deficiencies, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2012.

Records from 2012 to 2025. Most recent: inspection, 11 April 2025.

Built
1977
Last inspected
11 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 April 2025
Operational controls 1 with no removal date recorded
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA8944
Flag
UNITED STATES
Maury page id
psix-49228

Documentation record

Registered dimensions (L × B × D)109.0 ft × 24.8 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLANTANA BOATYARD INC · LANTANA, FL, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

11 April 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8099348
18 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8091346
6 June 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7916991
23 May 2023 In-Service Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7683421
17 April 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7667318
17 October 2022 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7574967
24 May 2022 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7452663
28 September 2021 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7329032
3 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7214630
6 April 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7170437
10 June 2020 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6977498
16 April 2020 Drydock Extension · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6939971
28 May 2019 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6696221
10 April 2019 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6659258
12 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6538670
29 May 2018 DAPI Audit · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6428100
20 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6394934
23 May 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6152685
18 May 2016 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5880116
16 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5834481

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2024 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. The waste receptacles on board the vessel were constructed of combustible material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 7 June 2024
Resolution: O/O replaced trash receptacles with approved type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Large hole found in bilge line in forepeak. Crop/ren in kind, test to satisfaction of OCMI. 46CFR119.500(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2022
Resolution: Corroded bilge piping was replaced with in kind and test:SAT.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 May 2022 Resolved
Each hydrostatic release unit, other than a disposable unit, must be serviced within 12 months of its manufacture and within 12 months of each subsequent servicing. EPIRB HRU was expired. 46CFR122.740(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2022
Resolution: Replaced with new HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in 46CFR164.018 in subchapter Q of this chapter or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Buoy reflective tape missing on (3) upper deck life ring buoys. 46CFR122.604(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 24 May 2022
Resolution: Added missing retroreflective tape to both life buoys.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit had expired Aspirin. 46CFR121.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: New first aid kit onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 May 2022 Resolved
Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system. Glass bulb light cover missing around light in engine room. 46CFR120.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: Light cover replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 24V panel was found in pilot house with no protective housing. 46CFR120.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: Protective housing installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 May 2022 Resolved
A hatch exposed to the weather must be watertight. Port and Stbd main deck bow windows in galley cannot be properly secured. 46CFR116.1160(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: Verified windows closed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 May 2022 Resolved
The float-free link required by § 117.130(a)(1) must be secured to the painter at one end and to the vessel on the other end. Painter lines were found not connected to either Port and Stbd IBA's. 46CFR117.137(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2022
Resolution: Painter lines connected to both IBA's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 June 2021 Resolved
For alternating-current generators a means for measuring frequency shall also be provided. The frequency meter for the vessel was inoperational. 46CFR183.10-5(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 1 September 2021
Resolution: Operationally tested frequency meter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2021 Resolved
Wires must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations and not used as a means of support. Vessel did not have necessary metal supports.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 1 September 2021
Resolution: Supported cable runs in engine room
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2019 Resolved
Exercises must be conducted at least once each calendar year. Security exercise has not been conducted within last 18 months.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 10 June 2019
Resolution: Vessel conducted security exercise.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
Vsl is not broadcasting a Call Sign, Vsl is broadcasting incorrect Name, Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 October 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Engineering › Bilge Water Management System › Pump
Issued 29 May 2018 Resolved
Replace #2 generator and prime mover for #2 bilge/fire pump by 13JUN18; temp (2) portable bilge pump approved arrangement NLT 13JUN18. 46CFR182.25-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 7 June 2018
Resolution: #2 generator and prime mover replaced, satisfactorily operated #2 bilge/fire pump.
Stability › Watertight Integrity › General
Issued 29 May 2018 Resolved
Seal all bulkhead wire runs and penetrations correctly by 31Mar2019. 46CFR171.070
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 10 April 2019
Resolution: Vessel used a fire retardent putty to fill gaps at wire through runs.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 May 2018 Resolved
Remove all oil/water from engine room bilge prior to carrying passengers. 33CFR151
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2018
Resolved 31 May 2018
Documentation › Logs/Records › Drug Test Records
Issued 29 May 2018 Resolved
Conduct DAPI audit with Coast Guard Inspector. 46CFR16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 4 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 May 2018 Resolved
Provide placards for life jacket donning (02) types of life jackets. 46CFR122.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 4 June 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 29 May 2018 Resolved
Provide catch bucket under leak, make permanent repairs to fuel piping by 31MAR19."46CFR119.435
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 10 April 2019
Resolution: Vessel replaced fittings on the fuel tank discharge line.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2018 Resolved
Enclose or remove dead end wires in mid-void. 46CFR183.05-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 22 June 2018
Resolution: All dead end wires now enclosed in junction box.
Stability › Watertight Integrity › General
Issued 29 May 2018 Resolved
Fix audible alarm on bridge for water tight door status. 46CFR170.255(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 22 June 2018
Resolution: Alarm tested and working properly
Documentation › Logs/Records › Drug Test Records
Issued 29 May 2018 Resolved
DER should have required EAP training and certificate of training by 18JUN18 46CFR16.401.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 22 June 2018
Resolution: DER completed EAP training
Communications › Radio Communications › EPIRB
Issued 23 May 2017 Resolved
Mount and register new EPIRB.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 31 May 2017
Resolution: Vessel rep. mounted and registered EPIRB.
Electrical › Lighting (service) › Conductor
Issued 23 May 2017 Resolved
Terminate dead end cable in a box in sewage tank space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 31 May 2017
Resolution: Vessel rep. placed cable in electrical box and mounted it in the sewage tank space.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 May 2016 Resolved
Renew retro reflective tape on PFD's which are no longer serviceable as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: New retro reflective tape placed on PFD's.

Casualty record · 1

24 July 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4389159
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.