CAPT. JOHN & SON

CAPT. JOHN & SON is a 1977 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in March 2026, along with 17 deficiencies and 3 casualty investigations between 2008 and 2023.

Records from 2008 to 2026. Most recent: inspection, 12 March 2026.

Built
1977
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF4293
Flag
UNITED STATES
Maury page id
psix-49279

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)76.9 ft × 22.2 ft × 7.6 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPLYMOUTH, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 20 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EASTERLY Research Vessel · MISLE 1060098 · 25 July 2022 · activity 7516473

Inspection history · 26

12 March 2026 Vessel Attendance · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8325654
22 May 2025 Deficiency Check · Annual Inspection · Vessel Attendance
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8128828
7 January 2025 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8059872
17 May 2024 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7902744
18 January 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7845689
15 July 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7743627
15 July 2023 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7745468
17 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7690419
12 May 2023 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668813
29 July 2022 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7672160
25 July 2022 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516427
25 July 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516473
13 April 2022 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7414163
14 March 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7404506
20 September 2021 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7311195
10 May 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7193589
26 May 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6960686
20 February 2020 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6907844
7 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6679764
13 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6539443
15 May 2018 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6411132
12 February 2018 Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6350470
27 November 2017 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6318782
4 April 2017 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6112893
28 March 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6112824
12 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5852176

Deficiency record · 17

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Winch used for lowering and raising anchor was severely wasted. Replace unit to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Anchor winch was replaced and operates satisfactorily.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 May 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel was missing the emergency broadcast instructions placard. O/O is to install at the radio installation area to satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 28 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 May 2024 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. For each alternating current generator, a means for measuring frequency must also be provided. Vessel's voltmeter on the Northern Lights generator was not functioning properly as it was showing voltage even with generator off. O/O is to provide a properly functioning voltmeter to the satisfaction on attending marine inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 28 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2022 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel suffered fire damage to port maine engine and electical wiring. Overhaul damages and affect proper repairs to the satisfaction of the attending marine inspection prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Attending MI inspected vessel and all associated with past fire. All:SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Pin holw in bilge line at Void #3. Crop/ren in kind, test to satisfaction of OCMI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
Resolution: Inspected repairs, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 April 2022 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. all weathertight doors are missing gaskets. make all doors weather tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 21 April 2022
Resolution: Inspected all new gaskets, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019 Resolved
An adult life jacket must be provided for each person carried on board. 08 life jackets missing. Max person allowed reduced to 141 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 23 May 2019
Resolution: 20 life jackets purchased. added missing life jackets and replaced an additional 12 KAPOK on board.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 October 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Construction/Loadline › Penetrations › Gasket
Issued 15 May 2018 Resolved
Make engine room and lazzarette scuttles watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 21 May 2018
Resolution: Made watertight.
Fire Fighting › Means of Escape › Blocked
Issued 15 May 2018 Resolved
Supply room means of escape scuttle is missing handle in space. Repair or replace scuttle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 21 May 2018
Resolution: Scuttle repaired.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 February 2018 Resolved
Replace port cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2018
Resolved 28 March 2018
Resolution: New cutlass bearing installed.
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2018 Resolved
Repair wasted hull plating IWO stbd engine room outboard of shaft thru hull approx 2ft x 3ft.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2018
Resolved 19 March 2018
Resolution: Plate replacement completed.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 30 March 2017 Resolved
Two IBAs were past service date. Complete annual servicing and reinstall IBAs to the satisfaction of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 21 April 2017
Resolution: Annual service complete and reinstalled on vessel.
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 March 2017 Resolved
Fresh water tank located in the laz had a soft patch and was leaking. Issued requirement to repair at next drydock.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 21 April 2017
Resolution: Welded seam on H2O tank, tank tested / inspected for leaks, all sat.
Engineering › Bilge Water Management System › Piping
Issued 12 April 2016 Resolved
Laz bilge suction line was wasted and holed in ER IVO of ladder. Repair/renew prior to carrying pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Bilge suction line repaired.
Engineering › Bilge Water Management System › Piping
Issued 12 April 2016 Resolved
Aft ER bilge suction line was wasted and holed in ER IVO of ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 13 April 2016
Resolution: Bilge suction line repaired.
Construction/Loadline › Hull › Weld
Issued 12 April 2016 Resolved
Identified 05 cracked welds (04 on deck and 01 in #1 voild, stbd side). Repair.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 13 April 2016
Resolution: Inspected repaired welds.

Casualty record · 3

14 July 2008Routine · role: Involved in a Marine Casualty · activity 3267958
25 July 2022Routine · role: Involved in a Marine Casualty · activity 7516473
15 July 2023Routine · role: Involved in a Marine Casualty · activity 7743627
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.