Records from 1984 to 2026. Most recent: inspection, 19 August 2026.
Inspection history · 64
19 August 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8468302
22 April 2026
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8346847
25 July 2025
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8193889
24 April 2024
COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7900544
22 August 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7774401
1 December 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7600698
17 October 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7578584
5 October 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7571942
10 August 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7282243
18 August 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7036397
23 May 2019
DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6691812
25 September 2017
Internal Structural Exam · Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6275409
14 December 2016
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6057314
18 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5945244
19 January 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5799394
20 July 2015
COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5177981
7 October 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5040154
5 November 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3356532
11 December 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3113565
1 October 2007
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3014037
20 July 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3001439
11 October 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2798147
12 October 2005
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2512518
8 November 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2237105
21 October 2003
Periodic Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1932270
1 November 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1699316
6 August 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1657179
10 January 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477125
18 October 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1074915
24 October 2000
Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1055438
1 November 1999
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 795871
14 October 1999
Re-Inspection · Drydock Extension
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126336
27 October 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 804063
31 October 1997
Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 781489
21 May 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1100326
8 July 1996
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1087315
28 May 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 875485
14 May 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1082109
1 June 1995
COI Inspection · Drydock Extension
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917321
23 January 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 177247
29 November 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1183066
17 October 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177188
16 November 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 829311
17 May 1993
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1432693
1 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 539232
18 November 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 826192
8 May 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 912417
8 December 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1230667
15 November 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219469
10 April 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208145
13 February 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1042405
23 January 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208579
10 May 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1039570
2 March 1988
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029340
23 November 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325433
8 December 1986
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023841
13 June 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992123
11 December 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1298072
25 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983541
27 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 980881
12 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978884
12 February 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1284508
3 January 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 976677
14 December 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 976953
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 October 2022
Resolved
TWO STIFFENERS BELOW THE LADDER ON THE PORT SIDE OF THE LAZARETTE HATCH ARE WASTED THROUGH. REPLACE.
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 31 October 2022
Resolution: USCG witnessed satisfactory welds in the lazarette.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 October 2022
Resolved
Vessel missed an annual inspection.
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. The annual inspection date of vessel is 03JUN, the max allowed annual date is 03SEP2022. Vessel must schedule and receive an annual inspection before passengers can be carried.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Vessel satisfactorily completed annual exam.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 August 2021
Resolved
Operation of transmitter of any ship station must be performed by a person holding a commercial radio operatrors licens or permit. Vessels Captain did not have Marine Operators Permit. Vessel is restricted to 1000 ft from shore.
47 CFR 80.159
Action required: 705 - Other - as specified
Due 10 August 2021
Resolved 25 August 2021
Resolution: Recieved picture of operator receipt of ordering Marine Operator [name withheld]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2021
Resolved
Ensure discharge ends of vent pipes are fitted with flame screen. Port side fuel vent pipe flame screen needs to be replace.
46 CFR 182.450
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2021
Resolved 25 August 2021
Resolution: Recieved picture of new flame screen
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 August 2020
Resolved
Vessel must carry charts adequate for intended voyage and shall be up to date. Vessel had two years old charts on board without chart updates.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 28 August 2020
Resolution: provided updated charts.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 August 2020
Resolved
Vessel had expired first aid kit on board. Provide proof of new kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 28 August 2020
Resolution: provided new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 3 June 2019
Resolved
Ensure vessel has 6 total flares onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 5 June 2019
Resolution: Vessel purchased new flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 May 2019
Resolved
Vessel due for examination no later than 14 March 2019. Vessel failed to complete annual inspection by due date. Vessel must complete satisfactory annual inspection prior to carriage of passengers and cargo.
46 CFR 176.500(b)(1)
24 May 2019: Vessel allowed to continue passenger and cargo operations until 07 June 2019.
Action required: 705 - Other - as specified
Due 7 June 2019
Resolved 3 June 2019
Resolution: Conducted successful COI.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 February 2018
Resolved
Replace fuel ine to Detroit Pump Engine with a fuel line that meets SAE J1942 standard.
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 19 March 2018
Resolution: New parker hoses installed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 July 2015
Resolved
JE02 - Repair port shaft seal to prevent excessive leakage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 July 2015
Resolution: Shaft packing was tightened to prevent excessive leakage during the inspection. Def corrected on the spot and cleared
Lifesaving › Lifefloat › Serviceable
Issued 20 July 2015
Resolved
JE01- Repair life float according to manufacture recommendations to prevent water intrusion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 5 November 2015
Resolution: Repaired lifefloat to satisfactory condition.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 November 2008
Resolved
Communications Act Safety Radiotelephony Certificate expired.
Due 1 December 2008
Resolved 14 December 2008
Resolution: Rcvd Fax copy of cert.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 December 2007
Resolved
Battery covers for the engine and generator batteries were missing.
Condition: Unknown
Due 11 January 2008
Resolved 23 January 2008
Resolution: A new cover was fabricated and installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 December 2007
Resolved
Anchor light was inoperable.
Condition: Unknown
Due 19 December 2007
Resolved 23 January 2008
Resolution: A new fixture and lamp were installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 December 2007
Resolved
Compass light inoperable.
Condition: Unknown
Due 19 December 2007
Resolved 23 January 2008
Resolution: New compass light installed.
Construction/Loadline › Structures › Superstructure
Issued 11 October 2006
Resolved
Vessels rail height does not meet current SDB policy. Informed owner that he had 1 year or until next drydock to bring rail height into compliance.
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 23 January 2008
Resolution: New, removable, rail installed and tested. 39.5"
Lifesaving › Lifefloat › Paddle
Issued 12 October 2005
Resolved
Provide and properly label one paddle for the L/F
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Engineering › Bilge Water Management System › Manifold
Issued 12 October 2005
Resolved
Properly label the bilge manifold system.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 12 October 2005
Resolved
Properly repair/replace the keel cooler hose that is chaffing on the stbd main engine.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Engineering › Bilge Water Management System › Valve
Issued 12 October 2005
Resolved
Properly repair/replace the check valve coming from the fwd compartment.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 October 2005
Resolved
Properly post a L/J donning placard.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Engineering › Compressed Air System (control) › Compressor
Issued 12 October 2005
Resolved
Properly mount the compressor.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 27 October 2005
Lifesaving › Lifefloat › Lifeline
Issued 8 November 2004
Resolved
Properly replace all tag lines on the 15 man Lifefloat. Requirement extended one week, due to the line being ordered. Extended the requirement to 6 Dec due to the line being ordered.
Action required: 705 - Other - as specified
Due 6 December 2004
Resolved 6 December 2004
Resolution: Replaced all tag lines.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 November 2004
Resolved
Properly replace the tag lines on all waterlights. Requirement extended one week, due to the line being ordered. Extended the requirement to 6 Dec due to the line being ordered.
Action required: 705 - Other - as specified
Due 6 December 2004
Resolved 6 December 2004
Resolution: Properly replaced all tag lines.
Lifesaving › Lifefloat › Paddle
Issued 8 November 2004
Resolved
Properly label all paddles and place one paddle in the 8 man lifefloat.
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 22 November 2004
Resolution: Received phone call from [name withheld] stating that the deficiency was corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 8 November 2004
Resolved
Properly label the cargo pump emergency shut down.
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 22 November 2004
Resolution: Recieved phone call from [name withheld] stating that descrepency was corrected.
Documentation › Certificates/Documents › FCC SSL
Issued 21 October 2003
Resolved
Renew the VHF safety telephony certificate.
Condition: Improper/Lack of Maintenance
Due 21 November 2003
Resolved 25 November 2003
Resolution: New five yr cert. onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 21 October 2003
Resolved
Provide a navigation chart for the Chesapeake bay as per COI route authorization.
Condition: Improper/Lack of Maintenance
Due 21 November 2003
Resolved 25 November 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 October 2003
Resolved
Renew the expired medications in the first aid kit.
Condition: Improper/Lack of Maintenance
Due 21 November 2003
Resolved 25 November 2003
Lifesaving › Buoyant Apparatus
Issued 21 October 2003
Resolved
Repair or renew the 7 person BA. Exterior foam and coating damage noted and misc. nylon webbing frayed.
Condition: Improper/Lack of Maintenance
Due 21 November 2003
Resolved 25 November 2003
Resolution: Owner elected to replace the BA with a 8 person Life float.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 October 2003
Resolved
Operator directed to properly support the misc. wires hanging unsupported in the engine room.
Condition: Improper/Lack of Maintenance
Due 21 November 2003
Resolved 25 November 2003
Engineering › Diesel Engine (auxiliary)
Issued 1 November 2002
Resolved
STBD GENERATOR DRY EXHAUST MISSING PROTECTIVE LAGGING. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 26 November 2002
Resolution: Installed protective covering.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 November 2002
Resolved
STBD GENERATOR MISSING BELT/PULLEY GUARD. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 26 November 2002
Resolution: INstalled belt guard.
Construction/Loadline › Structures
Issued 1 November 2002
Resolved
MANHOLE HATCH COVER FOR BALLAST TANK SPACE MISSING RETAINING LANYARD. LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 26 November 2002
Resolution: Installed new retaining lanyard.
Electrical
Issued 18 October 2001
Resolved
SUBMIT A ONE LINE ELECTRICAL DRAWING SHOWING THE ELECTRICAL INSTALLATION FOR THE VENTILATION FAN MOTORS IN THE BALLAST TANK AND STEERING COMPARTMENT.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Resolution: DRAWING SUBMITTED, REVIEWED AND PART OF VESSEL FILE
Lifesaving
Issued 18 October 2001
Resolved
REPLACE RETRO-REFLECTIVE TAPE BOTH LIFE FLOATS.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Engineering
Issued 18 October 2001
Resolved
REPAIR STBD MAIN DIESEL ENGINE TACHOMETER.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Navigation
Issued 18 October 2001
Resolved
PROCURE AN UPDATED DELAWARE BAY CHART.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Electrical
Issued 18 October 2001
Resolved
HARDWIRE ELECTRICAL WIRING ON RUDDER POST HEATERS.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Lifesaving
Issued 18 October 2001
Resolved
RE-RIG SEA PAINTER ON LIFE FLOAT.
Condition: Unknown
Due 18 November 2001
Resolved 10 January 2002
Electrical
Issued 24 October 2000
Resolved
REPLACE PLASTIC WIRE TIE SUPPORTS WITH PROPER METAL CABLE SUPPORTS.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Lifesaving
Issued 24 October 2000
Resolved
RELINE AND STENCIL WHEEL HOUSE LIFE RING.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 24 October 2000
Resolved
REPLACE BOTH THE PORT AND STBD ENGINE ROOM HATCH COVER GASKETS.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Lifesaving
Issued 24 October 2000
Resolved
STENCIL HOME PORT ON WHEELHOUSE RING BUOY.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Engineering
Issued 24 October 2000
Resolved
REPAIR EXHAUST LEAK ON 15KW GENSET.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 24 October 2000
Resolved
SUBMIT REPAIR PROPOSAL FOR LONGITUDINAL FRAME IN BALLAST TANK.
Condition: Unknown
Due 24 November 2000
Resolved 27 November 2000
Electrical
Issued 24 October 2000
Resolved
RENEW ELECTRICAL WIRING ON BOTH PROPULSION ENGINES TO ELIMINATE POSSIBLE ELECTRICAL DAMAGE AND HAZZARD TO PERSONNEL.
Condition: Unknown
Due 22 January 2001
Resolved 2 February 2001
Fire Fighting
Issued 14 October 1999
Resolved
FABRICATE AND INSTALL A PROTECTIVE GUARD OVER THE FIRE PUMP DRIVE SHAFT.
Condition: Unknown
Due 14 November 1999
Resolved 21 October 1999
Lifesaving
Issued 14 October 1999
Resolved
PROVIDE UPDATED EYE WASH FOR FIRST AID KIT.
Condition: Unknown
Due 14 November 1999
Resolved 21 October 1999
Navigation
Issued 27 October 1998
Resolved
PROVIDE A CURRENT EDITION OF CHART #12304.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Documentation
Issued 27 October 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Lifesaving
Issued 27 October 1998
Resolved
PROVIDE BRACKET FOR RINGBUOY WATERLIGHT.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Lifesaving
Issued 27 October 1998
Resolved
REPLACE THE PAINTER FOR THE BUOYANT APPARATUS.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 27 October 1998
Resolved
REPAIR STRAINER FOR BILGE SUCTION IN VOID #4.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Lifesaving
Issued 27 October 1998
Resolved
PROVIDE DONNING INSTRUCTIONS FOR PFDs.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Accommodation/Occupational Safety
Issued 27 October 1998
Resolved
REPAIR PORT BRIDGE WINDOW.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Engineering
Issued 27 October 1998
Resolved
REPAIR/REPLACE THE TACHOMETER FOR THE STBD MDE IN THE PILOTHOUSE.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Navigation
Issued 31 October 1997
Resolved
PROVIDE MASTHEAD LIGHT IAW RULE 23 OF THE INLAND RULES.
Condition: Unknown
Due 7 November 1997
Resolved 14 November 1997
Construction/Loadline
Issued 31 October 1997
Resolved
INSTALL BILGE STRAINER IN COMPANIONWAY.
Condition: Unknown
Due 7 November 1997
Resolved 14 November 1997
Navigation
Issued 31 October 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD IAW 46 CFR 184.506.
Condition: Unknown
Due 7 November 1997
Resolved 14 November 1997
Lifesaving
Issued 31 October 1997
Resolved
PROVIDE CG APPROVED FIRST AID KIT.
Condition: Unknown
Due 7 November 1997
Resolved 14 November 1997
Lifesaving
Issued 31 October 1997
Resolved
PROVIDE CG APPROVED WATERLIGHTS FOR BOTH B/As AND THE RING BUOY.
Condition: Unknown
Due 7 November 1997
Resolved 14 November 1997
Documentation
Issued 28 May 1996
Resolved
PROVIDE A SCIENTIFICALLY VALID METHOD FOR RANDOM DRUG TESTING, IN ACCORDANCE WITH 46 CFR 16.230 (c).
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996
Resolved
PROVIDE DOCUMENTATION THAT 20 PERSON BUOYANT APPARATUS IS A USCG APPROVED B/A.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 17 October 1994
Resolved
THE VESSEL IS RESTRICTED TO 44 PASSENGER TILL FIVE (5) ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 18 November 1994
Resolved 18 October 1994
Engineering
Issued 17 October 1994
Resolved
REPAIR OR REPLACE THE WHEELHOUSE TACHOMETERS FOR THE PORT AND STBD ENGINES.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Electrical
Issued 17 May 1993
Resolved
REWIRE ELECTRIC HOT WATER HEATER IN AFT. VOID.
Condition: Unknown
Due 28 May 1993
Resolved 11 June 1993
Navigation
Issued 17 May 1993
Resolved
REFASTEN/REBOLT FOUNDATION FOR STEERING GEAR.
Condition: Unknown
Due 28 May 1993
Resolved 11 June 1993
Electrical
Issued 15 November 1989
Resolved
REPLACE BATTERY CABLE FROM MAIN BATTERIES TO PORT GENERATOR.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Electrical
Issued 15 November 1989
Resolved
REPLACE GLOBE ON LIGHT PORT SIDE AFT ENGINE ROOM.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Electrical
Issued 15 November 1989
Resolved
REPLACE GLOBE AND GUARD ON LIGHT STBD SIDE AFT ENGINE ROOM.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Engineering
Issued 13 February 1989
Resolved
REPAIR AND DEMONSTRATE OPERATION OF BOTH PORT AND STARBOARD MAIN ENGINE OILPRESSURE GAUGES IN PILOT HOUSE.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Electrical
Issued 13 February 1989
Resolved
PROVIDE AMP, VOLT AND FREQUENCY METERS FOR SHIP SERVICE GENERATORS AS PER 46 CFR 183.10-5(G).
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Lifesaving
Issued 23 January 1989
Resolved
PROVIDE ONE (1) ADULT AND ONE (1) CHILD'S TYPE I PFD. VESSEL IS RESTRICTEDTO 51 TOTAL PERSONS UNTIL COMPLETED.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989
Resolved
PROVIDE DAY AND NIGHT DISTRESS SIGNALS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989
Resolved
RENEW GRABLINES AND PENDANTS ON THE 7 MAN BUOYANT APPARATUS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989
Resolved
DEMONSTRATE OPERATION OF THE TACHOMETERS AND OIL PRESSURE GUAGES FOR THE PORT AND STARBOARD MAIN ENGINES IN THE ENGINE ROOM AND ON THE BRIDGE.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989
Resolved
PROVIDE LAGGING FOR THE STARBOARD EXHAUST ELBOW, BETWEEN THE MANIFOLD AND FLEX CONNECTION, ON THE STARBOARD ENGINE.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Electrical
Issued 23 January 1989
Resolved
PROVIDE A VALVE HANDWHEEL FOR THE PORT GENERATOR RAW WATER SUCTION VALVE.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989
Resolved
DEMONSTRATE OPERATION OF THE STARBOARD EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989
Resolved
DEMONSTRATE OPERATION OF THE PORT AND STARBOARD FIRE/BILGE ENGINE DRIVEN PUMPS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Engineering
Issued 23 January 1989
Resolved
PROVIDE A FLAME SCREEN OF 30 X 30 MESH FOR THE PORT AND STARBOARD FUEL OIL VENTS.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 2 March 1988
Resolved
REPLACE NYLON STRAPS ON THE 7 MAN BUOYANT APPARATUS. NUMBER OF PERSONS ALLOWED ONBOARD REDUCED FROM 52 TO 40 UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Deck/Cargo
Issued 12 February 1985
Resolved
INSTALL A RELIEF DEVICE ON BACKUP CARGO PUMP PRIOR TO PLACING IT INTO OPERATION. (46 CFR 64.91)
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Accommodation/Occupational Safety
Issued 12 February 1985
Resolved
RENEW RAIL ON STERN TO 42" PRIOR TO CARRYING PASSENGERS. IF NOT RENEWED INKIND, SUBMIT PROPOSAL TO OCMI FOR REVIEW. (46 CFR 177.35-1(C)).
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Electrical
Issued 3 January 1985
Resolved
PROVIDE NEW FIBERGLASS OR LEAD LINING FOR MAIN BATTERY TRAY.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Lifesaving
Issued 3 January 1985
Resolved
PROVIDE ONE ADDITIONAL ORANGE DISTRESS FLARE (46 CFR 180.35-5(A)(1)) PRIOR TO VESSEL GETTING UNDERWAY.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Fire Fighting
Issued 3 January 1985
Resolved
LOCATE AND REMOVE SOURCE OF BLOCKAGE TO STARBOARD FIRE STATION FIRE MAIN LINE PRIOR TO VESSEL GETTING UNDERWAY.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Fire Fighting
Issued 3 January 1985
Resolved
REPAIR EXISTING MOTOR DRIVEN FIRE/BILGE PUMP PRIOR TO VESSEL GETTING UNDERWAY.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Electrical
Issued 3 January 1985
Resolved
RENEW GLOBE GUARD FOR ENGINE ROOM LIGHT STARBOARD SIDE ABOVE ENGINE EXHAUST.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Electrical
Issued 3 January 1985
Resolved
REMOVE ELECTRICAL RECEPTICAL AND DEAD END WIRE ON MAIN DECK AT STERN AMIDSHIPS.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985