Records from 2001 to 2014. Most recent: inspection, 1 October 2014.
Inspection history · 21
1 October 2014
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4996450
12 January 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4223419
12 January 2012
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4223600
11 January 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4224456
17 February 2011
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3941828
12 August 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3295658
5 May 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3199335
20 July 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3001439
5 July 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2984321
21 June 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2968815
20 June 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2968793
17 May 2006
Ballast Water Examination · ILO-147 Exam · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2651734
15 May 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2650266
16 March 2005
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2311468
13 March 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2309005
8 March 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2306317
6 November 2004
NPV Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2234595
23 July 2004
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2141660
8 October 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1924224
2 September 2003
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1888191
12 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294653
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 12 January 2012
Resolved
1410 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Ships main engine failed to maintain ordered RPM, resulting in reduction of available power. Ship had to anchor by order of the River Pilot. 74SOLAS(2001 cons), CH.1, R.11 17a/c issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2012
Resolution: Received class survey attesting to proper repairs of the main engine.
Lifesaving › Launching Appliances › Davit
Issued 17 February 2011
Resolved
0635 - Launch arrangt. for rescue boats - Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. PSCO observed that the lifeboat used as the rescue boat was capable of being lowered to embarkation deck, but could not be immediately raised to its stowed position. -SOLAS 74a III/16
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 19 February 2011
Resolution: Received, reviewed, and accepted class report from NKK stating the deficiency was rectified. The limit switch was found to be sticking. The switch was removed, overhauled, lubricated, and remounted. The lifeboat was successfully raised/lowered.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 17 February 2011
Resolved
0735 - Personal equipment - fire fighting - The equipment used during drills shall be immediately be brought back to its fully operational condition. PSCO observed that the air bottles used by the firemen during the fire drill were empty.
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 19 February 2011
Resolution: Received, reviewed, and accepted class report from NKK stating the deficiency was rectified. The two air bottles were put ashore for refilling and returned to the vessel.
Navigation › Piloting/Steering › Gyro Compass
Issued 17 February 2011
Resolved
1540 - Gyrocompass - The equipment required by 33 CFR 164.35 must be maintained in operable condition. Vessel was granted an LOD to enter and operate on the LMR with an inoperable gyro compass. - 33 CFR 164.11(r)
Action required: 705 - Other - as specified
Due 21 February 2011
Resolved 17 February 2011
Resolution: Received, reviewed, and accepted tech report from Electro-Tech, Inc. stating that the deficiency was rectified. Vsl received and installed new gyro and associated parts then conducted operational test with satisfactory results.
Deck/Cargo › Holds/Tanks › Hatch
Issued 12 August 2008
Resolved
Several Hydraulic Leaks were found on several rams for cargo hold hatch covers. Class to attest to repair and operation of all rams.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: Recieved class report stating hatchcovers are outstanding conditions of class. They scheduled to be repaired NLT 13 November 2008.
Fire Fighting › Fire Hoses › Condition
Issued 12 August 2008
Resolved
Several fire hoses have rusted host clamps attached near couplings at each end, crew needs to replace hoses or attest that all hoses can hold fireman pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: Witnessed satisfactory testing of all Port and Starboard side exterior hoses.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 12 August 2008
Resolved
Vessel has wood plugs for drains with one wasted. Vessel needs to have plugs that close via mechanical means. Prior to next bunkering in US.
Action required: 705 - Other - as specified
Due 26 August 2008
Resolved 14 August 2008
Resolution: reinspected all of the vessels transfer station containment drain plugs, all were mechanical and in satisfactory order.
Personnel › Training › Fire Fighting Basic
Issued 12 August 2008
Resolved
Crew's performance in fire drill was not adequate. Fire fighters entered space with out Breathing apparatus on their face with oxygen on. Crew did not take drill seriously. Crew will also have to re-do abandon ship drill because a muster was not done prior to lowering life boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Witnessed satisfactory Fire and Abandon ship drill.
Engineering › Gasoline Engine (auxiliary) › Radiator (4 cycle)
Issued 12 August 2008
Resolved
Radiator cap on emergency generator needs to be replaced because of jacket water that leaks by. Class to attest to repair of radiator cap.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: Received class report stating that Emergency Generator cap has been replaced, and class attested to proper operation of Emergency Generator.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 June 2007
Resolved
The top of the sewage holding tank has severe wastage around the chlorine treatment tubes. One of the tubes is wasted/rusted all the way through & is being held on by a thin piece of metal. The surrounding area of the tubes is severely corroded as well. This poses a severe health/safety hazard to the crew from a possible sewage leak/spill.
Action required: 705 - Other - as specified
Due 22 July 2007
Resolved 5 July 2007
Resolution: Received class report from NKK satisfying requirement.
Documentation › Logs/Records
Issued 2 September 2003
Resolved
Commence making entries into the oil record book as per the instructions found in Appendix III of Annex I of MARPOL 73/78 where the C-11, C-12.2, and C-12.3 entries have been combined and the quantity of contents retained is missing. LEGACY COMPONENT DESC: Oil Record Book
Due 2 September 2003
Resolved 2 September 2003
Documentation › Certificates/Documents
Issued 2 September 2003
Resolved
Include the W.O. Tank Capacity .49m3 in block 3.3.2.3 of the IOPP. MARPOL 73/78, I/17. Complete to the satisfaction of class. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2003