Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOREAUVILLE, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFALMOUTH, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton 19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 24 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 10 March 2026No resolution recorded
This part applies to passenger vessels inspected under Subchapter T or H of this chapter. Watertight integrity above the margin line in a vessel less than 100 gross tons: Each hatch exposed to the weather must be watertight, except that the following hatches may be weather tight: Each hatch on a watertight trunk that extends at least 12 inches above the weather deck, Each hatch on a cabin top, or each hatch on a vessel that operates only on protected waters. The vessel's engine room hatches are not watertight, and are not on a 12" trunk or cabin top. The vessel operates on a partially protected route. Provide a written plan to make the vessel's engine room hatches watertight to the attending/reviewing marine inspector, then upon approval to proceed, make the hatches watertight as required.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 September 2026
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 June 2025Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in ...The vessels midship hold is missing a required high water alarm, audible and visual. Provide to the satisfaction of the attending USCG MI.
46CFR 182.530
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 11 July 2025
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel to create separate log that clearly identifies the required drills and EPIRB testing to be presented to the attending USCG MI.
46CFR 185.728.c.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 31 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 June 2024Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Provide mechanical plug to the bottom of the f/o filer/water separator of the MDE to the satisfaction of the reviewing USCG MI.
46CFR 182.20-45.b.7. OLD T
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 15 July 2024
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 6 August 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2024Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Vessel is missing the required flame screen on the F/O tank vent. Install IAW with regulation.
46CFR 182.450.e.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 15 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 24 June 2024Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. The vessel's Man Overboard recovery procedures have the crew attending the stern platform. Provide a tethering system to the crew member that is laying beyond the vessels installed railing.
46CFR 177.900.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 31 July 2024
The vessel grounded near Oak Bluffs and caused damage to the hull and engine. The vessel must be hauled for further inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2021
Resolved 9 March 2021
Resolution: No dmg was observed during out of water inspection.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 April 2016Resolved
Post a lifejacket donning placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: Placard has been updated
Engineering › Bilge Water Management System › Pump
Issued 20 April 2016Resolved
Prove proper operation of electrical bilge pump (Aux) located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: Tesets proper operation of electrical bilge pump (Aux) located in the engine room. Test Sat
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2016Resolved
Provide new updated charts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: New charst with corrections has been purchased.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 April 2016Resolved
Remove or replace corroded electrical outlet located in the pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: Outlet box has been removed.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 20 April 2016Resolved
Prove proper operation of the starboard side exhaust system water alarm (high temp).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: tested proper operation of the starboard side exhaust system water alarm (high temp).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.