Records from 1999 to 2016. Most recent: inspection, 13 May 2016.
Inspection history · 24
13 May 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876300
14 May 2012
Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4299708
23 December 2010
MTSA/ISPS Verification · Administrative Inspection · ACP Handover Survey · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3915325
26 October 2010
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3887283
23 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349989
24 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213564
13 November 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3128774
16 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3081219
30 May 2007
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3016646
1 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919988
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750067
22 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2673953
24 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2520701
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501699
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294005
13 December 2004
Examination of Repairs · Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2258070
20 April 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2048225
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979596
18 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1758859
18 June 2002
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1632389
19 March 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494624
26 March 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462211
6 January 2000
Deadweight Survey · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372895
13 May 1999
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795740
Fire Fighting › Fire Hoses › Connections
Issued 14 May 2012
Resolved
Replace fire hoses with UL approved hoses and connections.
Due 14 June 2012
Resolved 26 June 2012
Communications › Alarms/Indicators › Fire Alarm
Issued 14 May 2012
Resolved
Replace fire alarm indicator light in engine room.
Due 14 June 2012
Resolved 20 June 2012
Stability › Watertight Integrity › General
Issued 14 May 2012
Resolved
Adjust watertight door on main deck to engine room.
Due 25 June 2012
Resolved 26 June 2012
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 May 2012
Resolved
Provide cover for local poistion indicator for port z-drive.
Due 14 June 2012
Resolved 26 June 2012
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 9 March 2011
Resolved
Provide approval letters for the remaining plans that were submitted to MSC. See attached "Drawing Submittal Tracking" document in MISLE. As per 46 CFR 127.120.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 25 January 2013
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 March 2011
Resolved
Conduct an operational launch and recovery test of the rescue boat. As per 74 SOLAS (09Cons) III/17
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: conducted
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 9 March 2011
Resolved
Provide a conformance test report for the vessel's LRIT. As per 74 SOLAS (09Cons) V/19-1
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Engineering › Bilge Water Management System › Piping
Issued 9 March 2011
Resolved
Make repairs and prove operation of the bilge system, in way of the center cargo area as per 46 CFR 128.440. Vessel is authorized to sail from Gulfport, MS to Fourchon, LA to make repairs to the satisfaction of the attending Coast Guard Inspector, prior to sailing from Fourchon, LA. The carriage of cargo and offshore workers are prohibited for this voyage.
Action required: 705 - Other - as specified
Resolved 11 March 2011
Resolution: Prior to leaving Gulfport, MS the Captain was able to prove successful operation of the vessel''s entire bilge system.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 9 March 2011
Resolved
Provide a current copy o fthe Tidal Current Tables as per 46 CFR 130.330.
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 March 2011
Resolved
Provide and place approved IMO symbols as required by SOLAS and teh approved Fire/Safety Plan as per 74 SOLAS (09 Cons) II-2/15.2.4 and IMO Resolution A.952(23)
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 26 October 2010
Resolved
Renew stbd Genset 75% overspeed module and test for MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2010
Deck/Cargo › Cargo Stowage › General
Issued 24 October 2005
Resolved
Show that repairs to #1 Dry Bulk tank meets requirement of the ASME code priro to 24 Nov 05, or make repairs to tank IAW ASME code prior to 24 Nov 05.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 29 November 2005
Resolution: Naval Arch. inspected area of concern, found that area was adequate for intended service. Vsl was built by ATV in Alabama, ECO has had repeated problems with getting drawings from this company.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 October 2005
Resolved
Provide fixed containment for Emerg Generator fuel vent at next Dry Dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 13 November 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 April 2004
Resolved
Make repairs to Oily Water Seperator and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 1 July 2004
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 20 April 2004
Resolved
Make modifications to Operating Station Gyro-Compass Repeater and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 1 July 2004
Lifesaving › Launching Appliances › Falls
Issued 20 April 2004
Resolved
Renew cable for crane and log all maintenance for the same.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 10 May 2004
Communications › Radio Communications
Issued 18 March 2003
Resolved
RENEW OR REPAIR ONE SART. LEGACY COMPONENT DESC: SART
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2003
Resolved 19 March 2003
Electrical › Electrical Distribution System (emergency)
Issued 18 March 2003
Resolved
PROVIDE PROPER LOCATION FOR STORAGE AND CHARGING OF BATTERIES LOCATED IN THE 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERIES
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2004
Resolution: Batteries relocated to the 01 deck storage space with adequate ventilation.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 18 March 2003
Resolved
REPAIR GROUND ON MAIN SWITCH BOARD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 19 March 2003
Engineering › Non-conventional Propulsion/Steering
Issued 18 March 2003
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON Z-DRIVE FLEXIBLE HOSES. LEGACY COMPONENT DESC: Flexible Hose (z-drive)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 18 March 2003
Fire Fighting › Fire Pumps
Issued 19 March 2002
Resolved
PRIOR TO SAILING DEMONSTRATE PROPER OPERATION OF THE EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: EMERGENCY FIRE PUMP
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2002
Resolved 19 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 March 2002
Resolved
INSTALL DIRT TRAP IN PAINT LOCKER FIXED CO2 PIPING BRANCH LINE.
Condition: Improper Installation
Due 19 April 2002
Resolved 19 March 2002
Construction/Loadline › Structures › Ventilators
Issued 19 March 2002
Resolved
INSTALL FLAME SCREENS IN ALL 4 LIQUID MUD TANK VENTS PRIOR TO TRANSFERING FLAMMABLE OR COMBUSTIBLE LIQUID MUD.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 19 March 2002
Construction/Loadline › Structures › Door
Issued 19 March 2002
Resolved
PROPERLY ADJUST ALL WATERTIGHT DOORS ON THE MAIN DECK AND BELOW.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2002
Resolved 19 March 2002
Documentation › Certificates/Documents
Issued 19 March 2002
Resolved
PROVIDE PROOF OF USER FEES PAYMENT LEGACY COMPONENT DESC: USER FEES PAYMENT
Due 19 March 2002
Resolved 19 March 2002
Resolution: SIGHTED PROOF OF USER FEES PAYMENT DATED 01/19/02
Documentation
Issued 26 March 2001
Resolved
PROVIDE PROOOF OF GMDSS MAINTENENCE WITHIN THE LAST TWELVE (12) MONTHS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 April 2001
Resolved 19 March 2002
Resolution: SIGHTED
Documentation
Issued 26 March 2001
Resolved
DEMONSTRATE PROPER OPERATION OF CONTINUOUSLY RECORDING DEPTH SOUNDER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 April 2001
Resolved 19 March 2002
Resolution: SIGHTED PROPER OPERATING DEPTH RECORDER
Lifesaving
Issued 6 January 2000
Resolved
Conduct man overboar drill (wx 5ft seas on trials) unsafe conditions.
Condition: Unknown
Due 17 January 2000
Resolved 22 January 2000
Deck/Cargo
Issued 6 January 2000
Resolved
Prior to loading Grade E Liquid mud in #2 S liquid mud tank prove proper operation of fill/suction valve.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000