C - PROMOTER

C - PROMOTER is a 1999 offshore supply vessel. The Coast Guard has recorded 24 inspections since 1999, most recently in May 2016, along with 29 deficiencies and 2 casualty investigations between 2006 and 2012.

Records from 1999 to 2016. Most recent: inspection, 13 May 2016.

Built
1999
Last inspected
13 May 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9220249 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ5472
495590
Flag
UNITED STATES
338630000 (licence lapsed)
Maury page id
psix-495590

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (1999–2016)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 728
ITC dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 728
BuilderN AMERICAN SHIPBLDG LLC · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1595 - Displacement, Ton
3258 - Dead Weight, Ton
2092 - Convention (Subpart B), Gross Ton
728 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ5472MMSI 338630000 · expired · compulsorily equipped · granted 7 October 2009, cancelled 28 December 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FRONT RUNNER SPAR Industrial Vessel · MISLE 636491 · 22 May 2006 · activity 2673953

Inspection history · 24

13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876300
14 May 2012 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4299708
23 December 2010 MTSA/ISPS Verification · Administrative Inspection · ACP Handover Survey · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3915325
26 October 2010 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3887283
23 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349989
24 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213564
13 November 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3128774
16 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3081219
30 May 2007 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3016646
1 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919988
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750067
22 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2673953
24 October 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2520701
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501699
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294005
13 December 2004 Examination of Repairs · Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2258070
20 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2048225
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979596
18 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1758859
18 June 2002 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1632389
19 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494624
26 March 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462211
6 January 2000 Deadweight Survey · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372895
13 May 1999 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795740

Deficiency record · 29

Fire Fighting › Fire Hoses › Connections
Issued 14 May 2012 Resolved
Replace fire hoses with UL approved hoses and connections.
Due 14 June 2012
Resolved 26 June 2012
Communications › Alarms/Indicators › Fire Alarm
Issued 14 May 2012 Resolved
Replace fire alarm indicator light in engine room.
Due 14 June 2012
Resolved 20 June 2012
Stability › Watertight Integrity › General
Issued 14 May 2012 Resolved
Adjust watertight door on main deck to engine room.
Due 25 June 2012
Resolved 26 June 2012
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 May 2012 Resolved
Provide cover for local poistion indicator for port z-drive.
Due 14 June 2012
Resolved 26 June 2012
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 9 March 2011 Resolved
Provide approval letters for the remaining plans that were submitted to MSC. See attached "Drawing Submittal Tracking" document in MISLE. As per 46 CFR 127.120.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 25 January 2013
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 March 2011 Resolved
Conduct an operational launch and recovery test of the rescue boat. As per 74 SOLAS (09Cons) III/17
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: conducted
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 9 March 2011 Resolved
Provide a conformance test report for the vessel's LRIT. As per 74 SOLAS (09Cons) V/19-1
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Engineering › Bilge Water Management System › Piping
Issued 9 March 2011 Resolved
Make repairs and prove operation of the bilge system, in way of the center cargo area as per 46 CFR 128.440. Vessel is authorized to sail from Gulfport, MS to Fourchon, LA to make repairs to the satisfaction of the attending Coast Guard Inspector, prior to sailing from Fourchon, LA. The carriage of cargo and offshore workers are prohibited for this voyage.
Action required: 705 - Other - as specified
Resolved 11 March 2011
Resolution: Prior to leaving Gulfport, MS the Captain was able to prove successful operation of the vessel''s entire bilge system.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 9 March 2011 Resolved
Provide a current copy o fthe Tidal Current Tables as per 46 CFR 130.330.
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 March 2011 Resolved
Provide and place approved IMO symbols as required by SOLAS and teh approved Fire/Safety Plan as per 74 SOLAS (09 Cons) II-2/15.2.4 and IMO Resolution A.952(23)
Action required: 705 - Other - as specified
Resolved 18 March 2011
Resolution: provided
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 26 October 2010 Resolved
Renew stbd Genset 75% overspeed module and test for MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2010
Deck/Cargo › Cargo Stowage › General
Issued 24 October 2005 Resolved
Show that repairs to #1 Dry Bulk tank meets requirement of the ASME code priro to 24 Nov 05, or make repairs to tank IAW ASME code prior to 24 Nov 05.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 29 November 2005
Resolution: Naval Arch. inspected area of concern, found that area was adequate for intended service. Vsl was built by ATV in Alabama, ECO has had repeated problems with getting drawings from this company.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 October 2005 Resolved
Provide fixed containment for Emerg Generator fuel vent at next Dry Dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 13 November 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 April 2004 Resolved
Make repairs to Oily Water Seperator and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 1 July 2004
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 20 April 2004 Resolved
Make modifications to Operating Station Gyro-Compass Repeater and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 1 July 2004
Lifesaving › Launching Appliances › Falls
Issued 20 April 2004 Resolved
Renew cable for crane and log all maintenance for the same.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 10 May 2004
Communications › Radio Communications
Issued 18 March 2003 Resolved
RENEW OR REPAIR ONE SART. LEGACY COMPONENT DESC: SART
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2003
Resolved 19 March 2003
Electrical › Electrical Distribution System (emergency)
Issued 18 March 2003 Resolved
PROVIDE PROPER LOCATION FOR STORAGE AND CHARGING OF BATTERIES LOCATED IN THE 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERIES
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2004
Resolution: Batteries relocated to the 01 deck storage space with adequate ventilation.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 18 March 2003 Resolved
REPAIR GROUND ON MAIN SWITCH BOARD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 19 March 2003
Engineering › Non-conventional Propulsion/Steering
Issued 18 March 2003 Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON Z-DRIVE FLEXIBLE HOSES. LEGACY COMPONENT DESC: Flexible Hose (z-drive)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 18 March 2003
Fire Fighting › Fire Pumps
Issued 19 March 2002 Resolved
PRIOR TO SAILING DEMONSTRATE PROPER OPERATION OF THE EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: EMERGENCY FIRE PUMP
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2002
Resolved 19 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 March 2002 Resolved
INSTALL DIRT TRAP IN PAINT LOCKER FIXED CO2 PIPING BRANCH LINE.
Condition: Improper Installation
Due 19 April 2002
Resolved 19 March 2002
Construction/Loadline › Structures › Ventilators
Issued 19 March 2002 Resolved
INSTALL FLAME SCREENS IN ALL 4 LIQUID MUD TANK VENTS PRIOR TO TRANSFERING FLAMMABLE OR COMBUSTIBLE LIQUID MUD.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 19 March 2002
Construction/Loadline › Structures › Door
Issued 19 March 2002 Resolved
PROPERLY ADJUST ALL WATERTIGHT DOORS ON THE MAIN DECK AND BELOW.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2002
Resolved 19 March 2002
Documentation › Certificates/Documents
Issued 19 March 2002 Resolved
PROVIDE PROOF OF USER FEES PAYMENT LEGACY COMPONENT DESC: USER FEES PAYMENT
Due 19 March 2002
Resolved 19 March 2002
Resolution: SIGHTED PROOF OF USER FEES PAYMENT DATED 01/19/02
Documentation
Issued 26 March 2001 Resolved
PROVIDE PROOOF OF GMDSS MAINTENENCE WITHIN THE LAST TWELVE (12) MONTHS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 April 2001
Resolved 19 March 2002
Resolution: SIGHTED
Documentation
Issued 26 March 2001 Resolved
DEMONSTRATE PROPER OPERATION OF CONTINUOUSLY RECORDING DEPTH SOUNDER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 April 2001
Resolved 19 March 2002
Resolution: SIGHTED PROPER OPERATING DEPTH RECORDER
Lifesaving
Issued 6 January 2000 Resolved
Conduct man overboar drill (wx 5ft seas on trials) unsafe conditions.
Condition: Unknown
Due 17 January 2000
Resolved 22 January 2000
Deck/Cargo
Issued 6 January 2000 Resolved
Prior to loading Grade E Liquid mud in #2 S liquid mud tank prove proper operation of fill/suction valve.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000

Casualty record · 2

22 May 2006Routine · role: Involved in a Marine Casualty · activity 2673953
24 October 2012Routine · role: Involved in a Marine Casualty · activity 4474989
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.