Records from 2004 to 2025. Most recent: inspection, 4 August 2025.
Inspection history · 53
4 August 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8375561
8 May 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7908945
29 July 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7519492
21 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482789
3 November 2021
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7344672
9 September 2021
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7309053
23 June 2021
Administrative Inspection · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7288660
12 September 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7065057
23 July 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7018061
8 July 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7001300
24 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6760894
7 May 2019
In-Service Inspection · COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6670842
2 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6675165
23 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6674498
23 March 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6654958
25 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628884
11 April 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6390951
11 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6429047
16 October 2017
Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6288790
19 August 2017
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6245291
11 July 2017
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6206552
2 March 2017
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6098490
28 July 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5956895
5 October 2015
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5736376
16 June 2014
Administrative Inspection · Hull Examination · COI Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4872670
29 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4873723
19 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4388216
14 February 2012
Administrative Inspection · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4312079
20 September 2011
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4212182
6 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4080178
20 September 2010
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3879833
10 February 2010
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3678921
20 January 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3667347
23 December 2009
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3654540
14 July 2009
Internal Structural Exam · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3534064
2 July 2009
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3529548
25 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439712
27 October 2008
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439321
8 November 2007
In-Service Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3095334
23 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2948527
12 September 2006
Re-Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2778263
22 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2673953
10 April 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2621341
21 March 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2615444
9 March 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2612901
23 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2577019
5 December 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2556895
21 October 2005
Re-Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2519490
21 January 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2278755
21 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2262987
27 November 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2249559
2 August 2004
Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2149526
6 February 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2001630
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 July 2020
Resolved
While performing a deck walk on the side of the cellar deck (float cell), CG observed wasted decking with BELZONA repairs. Make permanent repairs to be free from recognized hazards.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2022
Resolution: Received pictures of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 8 July 2020
Resolved
Hand railings in the location of helo fueling station and the west helo stairwll was found deteriored and wasted. Make permanent repairs to remove recognized hazardous.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2022
Resolution: Received pictures of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 July 2020
Resolved
Launching of lifeboats was lasted performed on 25NOV2019. Company has been in communication with D8 OCS OCMI for alternative procedures. Until alternative procedures are approved or agreed upon, launches must be performed quarterly.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2022
Resolution: Received video and logs of launching life boats.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 7 May 2019
Resolved
Portable or fixed eyewash equipment providing emergency relief must be immediately available near where there is a reasonably probability that eye injury may occur. The eyewash station near the glycol skid produces orange/rust water that is inadequate for flushing eyes. Make repairs/replacement the remedy issue.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
Resolution: The potable water has been secured that supplies the deficient eyewash station, and a portable has been installed in its place.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 11 April 2018
Resolved
During inspection of galley, marine inspectors observed approximately a 2" gap on bottom of galley door. In addiiton, MIs tested galley shutters. Galley shutters would not close when weak link was disconnected. In addition, during inspection of laundry room door, a 2" gap was found on bottom of the door. Make appropriate repairs to satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 30 April 2018
Resolution: recieved email from HSE supervisor that def was cleared.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 11 April 2018
Resolved
MIs found several Roxbox installations and vertical/horizontal wiring penetrations improperly installed throughout. In addition, several grounds were found to be disconnected or busted throughout. Make appropriate repairs to satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 11 May 2018
Resolution: Unit HSE Rep provided email attesting to the correction of the Def.
Electrical › Electric Supply System (service) › Cable
Issued 11 April 2018
Resolved
MIs observed several portable cables in galley and crew mess. Make all connections permanent type to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 11 May 2018
Resolution: Unit HSE Rep provided email attesting the correction of
Fire Fighting › Fire Pumps › Arrangement
Issued 11 April 2018
Resolved
During testing of the two (2) independently driven fire pumps, MIs observed the following:
a. Evidence of exhaust leaks at the turbo.
b. welder cables at battery box
c. wasted fuel bracket/fuel rail
d. air hoses supplying lube oil/fuel
Make appropriate repairs to both fire pumps to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 9 July 2018
Lifesaving › Lifebuoys › Serviceable
Issued 11 April 2018
Resolved
MIs found 01 ring buoy with wasted plug. Replace to satisfaction of attending USCG MI.
Due 11 April 2018
Resolved 11 April 2018
Resolution: Corrected on the spot
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 11 April 2018
Resolved
During examination of FM200 system, MIs found several bottles either overcharged or below the required pressure. Present a 3rd party report attesting to the proper pressure of the FM200 system on board to the satisfaction of the attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 11 May 2018
Resolution: Unit HSE rep provided email attesting to clearence of def.
Lifesaving › Launching Appliances › Winch
Issued 11 July 2017
Resolved
Winch CG approvals contradict the replacement of the winch for lifeboat "A" as stated on the servicing report. Provide documents from Alexander/Ryan attesting to the replacement of falls, replacement of winch on lifeboat "A" and a completed load test that occurred on/around January 13, 2016.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: A revised load test report was provided (attached).
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 11 July 2017
Resolved
Rescue boats are required to be lowered monthly. At the time of inspection the Fast Rescue Craft was being lowered once every three months. Lower as soon as practicable and log accordingly.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: On 2AUG2017 recieved notice that the rescue boat was lowered, function tested, and logged accordingly on 7/20/2017.
Lifesaving › Lifeboat › Fire Protection (general)
Issued 11 July 2017
Resolved
The self-contained air supply bottle for lifeboat "A" has blow-by. Provide a technitian report attesting to proper operation.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: Lifeboat air supply was re-tested with ABS ([name withheld]) and tested satisfactory. It was noted that the valve on the #4 bottle was difficult to close which is the root cause for the “blow-by”. Replacement bottles are ordered for Q3 2017 install.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 July 2017
Resolved
Lifeboat "C" has been removed from the unit. The Emergency Evacuation Plan (EEP) however has never been amended to reflect the removal of the lifeboat. Subbmit an updated EEP to the D8 OCS OCMI for review/approval.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 19 August 2017
Resolution: Reviewed and approved revised EEP.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 July 2017
Resolved
Electrical Room's fire detection system lacks a serviceable Time Delay Bottle. Replace the Time Delay Bottle.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: Updated EEP was received. Preliminary approval completed. Approval letter in drafted.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 11 July 2017
Resolved
It was discovered that the unit did not have a ISIP approval letter on board nor did the plan bear a USCG approval stamp. A review of the plan revealed that the plan lacked any schedule, that the schedule provided was an incomplete internal document, and the unit seemed to be relying solely on ABS consulting to provide the schedule and list of tanks to enter and inspect. Furthermore there was dis
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: An approved ISIP (attached) was provided.
Electrical › Electrical Distribution System (service) › Conductor
Issued 11 July 2017
Resolved
It was discovered that the battery wiring from battery box to starter was utilizing Welding Cable and by passing the conduit. Vessel was directed to replace welding cable runs in use at both fire pumpsrewire and w/ marine cable.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: Firewater pump battery cables were rewired per OEM specification.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 March 2017
Resolved
Galley door entering messdeck does not latch. Fire door is a A-15 fire boundary. Restore door to original condition.
Due 9 March 2017
Resolved 7 March 2017
Resolution: Received email from OIM stating latch was repaired.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 2 March 2017
Resolved
Station Bill does not accurately describe duties and responsiblities of personnel onboard. Update Station Bill.
Due 9 March 2017
Resolved 21 March 2017
Lifesaving › Lifebuoys › Serviceable
Issued 28 July 2016
Resolved
Lifebuoys were not properly spliced to line/light/smoke. Resplice. 46CFR108.580(2)(d) & 46CFR109.301(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 29 July 2016
Resolution: Recieved call from vsl rep that lifebuoys had been propely respliced.
Lifesaving › Launching Appliances › Winch
Issued 8 October 2015
Resolved
The winch cable on Lifeboat B's outter drum is not spooled on winch drum correctly. Respool cable on winch so as cable spools correctly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2015
Resolved 12 November 2015
Resolution: [name withheld] respooled fall cable on drum. Pictures submitted. Front Runner had been approved a 14-day extensions by [name withheld] b/c of weather delay and limited berthing for third parties.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 October 2015
Resolved
The HIMA panel on the production deck near MCC is a general enclosure in a hazardous location. The components inside general use enclosure were not readily apparent to be approved to be in a hazardous location. Provide documentation that the individual components in the panel meet the Class I Div 2 approval standards.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 November 2015
Resolved 6 November 2015
Deck/Cargo › Cargo Transfer (solid) › General
Issued 8 October 2015
Resolved
Top window on 1100 crane cab was broken. Replace window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 November 2015
Resolved 6 November 2015
Resolution: Replaced window. Pictures submitted.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 May 2014
Resolved
Multiple non self closing fire doors throughout living quarters and temporary living quarters. Replace/repair as per original manufacturer
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 8 August 2014
Resolution: Received report from [name withheld] stating that all fire doors throughout facility had been adjusted and now are properly closing.