Records from 1982 to 2026. Most recent: inspection, 5 May 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 7 May 2026
No resolution recorded
A vessel of 24 meters (79 feet) in length or more, the keel of which was laid or that was at a similar stage of construction on or after July 21, 1968, and that is on a voyage other than a domestic voyage is subject to load line assignment, certification, and marking under subchapter E (Load Lines) of this chapter. Based on the applicability contained in 46 U.S.C. 5102, vessel engages in voyages between Guam and the Commonwealth of the Northern Marianas Islands, and is required a load line. An International Load Line Certificate is required no later than next due dry-docking, 31Aug2027.
46 CFR 175.122 - 705 c.
Action required: 705 - Other - as specified
Due 31 August 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Observed steam pouring out of port side engine (outboard bank), and exhaust leak on port side engine (outboard bank) past turbo. Replace exhaust manifold gasket and gasket seal as needed.
46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2026
Resolved 17 March 2026
Resolution: Exhaust manifold taken apart, resurfaced and heat cycled to provide propper fit. MI attended after repairs and ran engine at dock after vessel return to dock from 2 hr u/w service. No observed leaks or issues noted. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 December 2025
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed.
The vessel did not complete an annual inspection within the periods specified in § 176.500(b)(1).
46 CFR § 176.502
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2025
Resolved 11 February 2026
Resolution: Completed satisfactory annual inspection. COI endorsed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 November 2024
Resolved
All vessels except non-self propelled vessels shall be
provided with suitable steering apparatus. Rudder angle
indicator linkage disconnected in steering space, rudder
angle indicator unresponsive at the wheelhouse controls.
46 CFR 182.30-1 - 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 20 December 2024
Resolution: Linkage installed and tested at both operating station and lazarette, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 November 2024
Resolved
At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition. Motor controller
switch on stbd side fantail found with dead end wires
and not in use. Remove wiring and or blank casing to
prevent shock or water ingress to satisfaction of Marine
Inspector.
46 CFR 176.830 - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 20 December 2024
Resolution: Switch to fuel transfer pump fit with button switch, no gaps present, tested all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2024
Resolved
All portable fire extinguishers installed on vessels
shall be of an approved type. Fire extinguisher forward
of port main engine in engine room found without pin or
securing seal to prevent accidental discharge.
46 CFR 181.30-5 - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 20 December 2024
Resolution: New pin fitted to prevent accidental discharge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 November 2024
Resolved
Gauges to indicate engine cooling water discharge
temperature and lubricating oil pressure shall be
provided for all propulsion engines and located so as to
be in view of operator. Stbd main engine oil pressure
gauge inoperable at the wheelhouse.
46 CFR 182.20-5 - 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 20 December 2024
Resolution: Verified reading at wheelhouse, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 November 2024
Resolved
Gauges to indicate engine cooling water discharge
temperature and lubricating oil pressure shall be
provided for all propulsion engines and located so as to
be in view of operator. Both F/W temp gauges for port
and stbd main engine found inoperable, both locally and
at the wheelhouse.
46 CFR 182.20-5 - 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 20 December 2024
Resolution: New gauges fitted and reading reflected running condition of main engines, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 November 2024
Resolved
Gauges to indicate engine cooling water discharge
temperature and lubricating oil pressure shall be
provided for all propulsion engines and located so as to
be in view of operator. Both port and stbd reduction
gear gauges for oil pressure found labelled incorrectly
with “oil temp.”
46 CFR 182.20-5 - 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 20 December 2024
Resolution: Gauges relabelled correctly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 November 2024
Resolved
At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition. Emergency lighting
for the port four person berthing found connected with
the bunk light switch. Properly connect emergency
lighting to prevent from being inadvertently turned off.
46 CFR 176.830 - 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 20 December 2024
Resolution: Lighting was re-wired to main switch and not bunk switch. Emergency lighting tested on blackout condition, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 November 2024
Resolved
Each vessel certificated to operate on a coastwise route
in warm water must be provided with life floats of an
aggregate capacity that will accommodate at least 100%
of the total number of persons permitted on board. Both
22 person [name withheld] life floats found faded and cracked
in multiple areas. Repair IAW manufacturers requirements
and or replace prior to next Annual Inspection.
46 CFR 180.204(c) - 705 c.
Action required: 705 - Other - as specified
Resolved 11 February 2026
Resolution: New life floats inspected and installed satisfactorily onboard. Life floats replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 December 2022
Resolved
Prior to carrying overnight passengers and/or operating on an Oceans route, vessel must comply with the SPV Fire Safety regulations in accordance with 46 CFR 175.110. Copy of regulation attached for applicable requirements and effective dates. Pending compliance with the new fire safety regulations, the vessel is prohibited from carrying overnight passengers and operating on an Oceans route.
Action required: 705 - Other - as specified
Resolved 17 August 2023
Resolution: Fire detection system and watchman alert system were installed IAW with approved plans and tested by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 26 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Repair severely wasted drum controller handle and break band on anchor winch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Repair 3 inches crack/tear IWO starboard bow below chock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2022
Resolved
An enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space.
Repair wasted & permanentally rusted in place vent plug for space FWD of collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for protection against fire. Replace two old fire hose with damaged/worn outer hose protection cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 October 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Install missing three lifelines AFT passenger deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 26 October 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Mark fuel shotoff station AFT weather deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2022
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Install two additional hose clamps on port turbo charger oil drain line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Replace loose nut on reduction gear control linkage with proper connecting pin with cutter pin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Install missing valve handle on STBD propulsion engine cooling water system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2023
Resolved 25 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last eamination must undergo a dry dock examination and an internal structural at least once every two years. Vessel is overdue for a dry dock and internal structural exam as of 30JUN2022. Prior to carrying cargo/passengers for hire, the required COI safety exams must be completed to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2022
Resolved
Vessel reported an unexpected shutdown on the stbd ME. Vessel is to conduct permanent repairs to the satisfaction of the atending CG MI prior to carrying passengers/cargo.
Action required: 702 - Prior to embarking on international voyage
Due 28 May 2022
Resolved 17 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 March 2022
Resolved
46 CFR 176.830: Vessel is limited to operating within Outer Apra Harbor pending repairs to A/C. Vessel's A/C for internal accommodation spaces is inoperable resulting in crew having to open all watertight doors during transits beyond three miles offshore while operating commercially: carrying passengers hire and cargo operations.
Action required: 705 - Other - as specified
Resolved 10 March 2022
Resolution: A/C repaired and proved operation to the attending USCG MI.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 October 2021
Resolved
Rigid nonmetallic hoses shall be adequate for its intended service. Install missing hose clamps on nonmetallic hose clamps for gray tank discharge hose
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 October 2021
Resolved
Construction of the vessel shall be such as to minimize fire hazards. Install fire retardant floor tiles in the area around electrical stove in galley.
Action required: 705 - Other - as specified
Due 27 November 2021
Resolved 7 March 2022
Resolution: Electrical stove/oven removed from vessel and will not be carried on board until galley tiles are replaced with USCG approved fire retardant tiles to the satisfaction of USCG.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 October 2021
Resolved
Fixed fire extinguishing system shall be install to protect the machinery space. Remove tape and absorbent pads on CO2 fix fire extinguishing nozzle in E/R.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 27 October 2021
Resolved
Machinery space shall be fitted with adequate ventilators. Repair inoperable starboard E/R ventilation motor.
Action required: 705 - Other - as specified
Due 27 November 2021
Resolved 7 March 2022
Resolution: Inoperable engine room electrical exhausts replaced with new as original and tested to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 October 2021
Resolved
Rigid nonmetallic hoses shall be adequate for its intended service. Replace all identified damaged nonmetallic hoses on fixed fire extinguisher system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2021
Resolved
Auxiliary machinery shall be design for the purpose intended. Repair wasted and holed expansion tank on prime mover for port generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2021
Resolved
Auxiliary machinery shall be design for the purpose intended. Install missing bolt/fastener on oil cooler on prime mover for port generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2021
Resolved
Rigid nonmetallic hoses shall be adequate for its intended service. Replace damaged nonmetallic hose on port air compressor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2021
Resolved
Auxiliary machinery shall be design for the purpose intended. Repair exhaust leak on starboard generator prime mover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2021
Resolved
Rigid nonmetallic hoses shall be adequate for its intended service. Install missing hose clamps on nonmetallic hose for starboard generator prime mover cooling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2021
Resolved
Auxiliary machinery shall be in proper operating condition and fit for service intended. Clean or replace dirty/ clogged air filter on starboard generator prime mover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021
Resolved
An ammeter must be readily visible shall be include in the battery charger circuit. Repair damaged ammeter on LaMarche battery charger.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2021
Resolved
Relief valve on unfired pressure vessel shall be check. Replace seized pressure relief valve on port air receiver.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2021
Resolved
Main propulsion machinery shall be in proper operating condition and fit for service intended. Repair wasted and holed water-cooling pipe on starboard propulsion engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 October 2021
Resolved
Electrical installation shall be to the satisfaction of the OCMI rep. Repair burnout engine room ceiling lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2021
Resolved
Nonmetallic pipe (hose) shall have protective cover or chafing cover for protection from mechanical damage. Install shield or chafing protection on nonmetallic fuel line for middle propulsion engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021
Resolved
Electrical panel shall be shield to prevent accidental contact by a person with energized circuit. Install missing breaker or install blank cover on missing breaker in electrical panel FWD E/R.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 27 October 2021
Resolved
Rigid nonmetallic hoses shall be adequate for its intended service. Replace deteriorated nonmetallic hose on discharge side on bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 October 2021
Resolved
Bilge high-level alarm shall be satisfactory condition and fit for service intended. Repair inoperable bilge high level alarm for crew accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 October 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Prove proper operation of anchor and navigational lights. Repair top mast light and prove operation. Screen for aft stern light must be repainted matte black. Ensure all screens are painted matte black in accordance with Navigation Rules.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Replace missing operable portable battery lights to be maintained onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2021
Resolved
Replace deteriorated/sun damaged starboard side ring buoy with new in accordance with vessels COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 27 October 2021
Resolved
Electrical equipment and installations must be suitable for the roll, pitch and vibration of the vessel underway. Properly secure motors/pumps in forward crew cabin and stove in galley to the satisfaction of the USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021
Resolved
(1) Bridge electrical panel must be marked to identify each equipment and amperage. (2) Properly tag out electrical switch and equipment not in use. Inspected forward crew cabin electrical panel with switches taped over.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 October 2021
Resolved
Each survival craft on a vessel must be inspected monthly using the manufacturer’s instructions to make sure it is complete and in good order. Vessel to conduct monthly inspections of IBAs and log in vessel’s official logbook.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 14 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 October 2021
Resolved
Each survival craft (IBAs, liferafts, etc.) must be visually inspected on a weekly basis to ensure its readiness for use. Vessel to conduct weekly inspection of IBAs including liferaft when installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2021
Resolved
The emergency lighting required per cite must automatically actuate upon failure of the main lighting system. Forward crew cabin emergency light is also connected to the main circuit that supplies power to the overhead lighting fixture. Repair and prove proper operation of the forward crew cabin E-light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Properly connect wires to Public Address system in galley and prove proper operation.
Action required: 705 - Other - as specified
Resolved 10 March 2022
Resolution: New PA installed and tested to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 October 2021
Resolved
All escape hatches and other emergency exists used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR”. Remark escape hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2021
Resolved
Independent modular smoke detecting unit must meet UL 217 and contain an independent power source and alarm on low power. Prove operation of smoke detector in shower room. Ensure smoke detectors are properly secured to the overhead to prevent from damage and meet UL217.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 October 2021
Resolved
Verify vessel’s correct official call sign and update FCC Certificates, NOAA EPIRB registration and emergency placard at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 29 November 2021
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 27 October 2021
Resolved
General housekeeping must be maintained at all times. Crew and passenger cabins must be kept clean and free of trash, vessel stores/equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 October 2021
Resolved
Visibly post number of adult/children life jackets with arrows showing location where stowed. Visibly mark locations to show where additional lifejackets are located in a cabin below the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 27 October 2021
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Prove operation of adequate emergency located below the main deck, visibly post luminescent arrows in lower passenger/crew accommodations to emergency egress, and prove emergency lighting at operating station provides adequate lighting for emergency egress.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2021
Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Replace non-combustible receptacles with new and maintain on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 27 October 2021
Resolved
All toilets and washbasins provided shall be fitted with adequate plumbing. Facilities for men and women shall be in separate compartments. Prove operation of toilets and washbasins.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 14 January 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 October 2021
Resolved
Replace expired and missing eyewash solution in galley with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 October 2021
Resolved
Captains and deckhands employed on the vessel conduct another fire, man overboard and abandon ship drill and log in the vessel’s official logbook. Contact USCG MI to schedule another visit to witness drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 October 2021
Resolved
Prior to carrying overnight passengers, operator to provide in writing procedures for Emergency Drills General in Small Passenger Vessel T-Boat Checklist, CVC-FM-021(1) to be provided to the crew for familiarization and verification by the attending USCG MI.
Action required: 705 - Other - as specified
Due 27 November 2021
Resolved 14 January 2022
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 October 2021
Resolved
(1) Post emergency instructions at operating station with emergency instructions per cite. (2) Emergency instructions listed in 46 CFR 185.512 must be designed to address the particular equipment, arrangement, and operation of each individual vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 2 December 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 27 October 2021
Resolved
A station bill that set forth the special duties and duty station of each crew member for various emergencies must be posted by the master on a vessel of more than 65 feet in length having a COI requiring more than four crewmembers at any one time, including the master and must be posted at the operating station. Provide proof of a station bill for USCG review. Vessel is required to have an additional crew when on voyages more than 12 hours within a 24 hour period and/or when carrying overnight passengers for hire. Vessel is limited to carrying no more than 6 overnight passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 7 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2021
Resolved
Repair leak to port side exhaust to the satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2021
Resolution: Repairs completed; ran port engine with rpm increased and observed no leaks to outboard exhuast bank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2021
Resolved
Port and starboard expansion tanks missing cap or gooseneck vent. Repair to the satisfaction of MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2021
Resolution: Gooseneck vent installed to prevent expansion of hot water from escaping rapidly from tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2021
Resolved
Replace wasted bolts on forward anchor winch drum with new and prove operation of winch drum to the satisfaction of the attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 September 2021
Resolved
All electrical circuits must be marked and identified. Missing list of equipment and amps.
Action required: 705 - Other - as specified
Due 27 November 2021
Resolved 7 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 September 2021
Resolved
Repair port main engine water temperature gage and prove operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 September 2021
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspections. No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspections. Repair steering gear system to as original and prove operation IAW 46 CFR 182.610 to the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2021
Resolution: Replaced missing pin on port clevis.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 September 2021
Resolved
Annual inspection-Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel's annual inspection is overdue as of 09AUG2021. Annual must be completed prior to carrying passengers for hire to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2021
Resolution: See MISLE Activity: 7311786 for result of annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 September 2021
Resolved
Each launching appliance and each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Replace deteriorated and weathered port side bouyant apparatus with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2021
Resolved
A vessel equipped with pilothouse control must have a fixed means of two-way communications from the operating station to the location where the means of controlling the propulsion machinery, required by 46 CFR 184.620(a) of this part, is located. Prove operation of onboard two-way communications from the operating station to propulsion machinery space to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2021
Resolution: Fixed existing two-way communication fixed and tested to the satisfaction of the attending MI. Vessel will include use of portable radios as back up and secondary means.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 June 2021
Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Remove all oily waste from the bilges and determine cause of oil leaks from all three main propulsion engines. Effect repairs in accordance with manufacturer's procedures and tests to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
Make repairs to the water leaks at the port and starboard raw water sea chest supplies for the main diesel engines.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2020
Resolution: Leaks resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 October 2020
Resolved
Prove the proper operation of the remote shutdown for the main diesel engines (03ea) from the main pilothouse control station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2020
Resolution: Remote main engine shutdowns operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2020
Resolved
Properly readjust loose drive belt on air compressor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 7 July 2020
Resolved
Re-seal leaking deck hatch cover over generator compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 July 2020
Resolved
Replace rusted / wasted pipe on fixed CO2 system with in-kind pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 July 2020
Resolved
Show proper operations of the alarm panel port bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 27 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2020
Resolved
Repair fuel leak on secondary fuel filter port propulsion engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 July 2020
Resolved
Replace/repair inoperable engine temperature gauge for port propulsion engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2020
Resolved
Replace expired eye wash solution in galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2019
Resolved
A VESSEL MUST BE PROVIDED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGHT COMPARTMENT, UNDER ALL PRACTICABLE CONDITIONS. VESSEL IS UNABLE TO DEMONSTRATE PROPER OPERATION OF THE FIXED BILGE DEWATERING SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2019
Resolved
ON A VESSEL MORE THAN 65 FEET AND CARRYING MORE THAN 49 PASSENGERS, THE MINIMUM CAPACITY OF THE FIRE PUMP MUST BE 50 GALLONS PER MINUTE AT A PRESSURE NOT LESS THAN 60 PSI AT THE PUMP OUTLET. FIRE MAIN SYSTEM UNABLE TO PROVIDE ADEQUATE PRESSURE. #1 FIRE PUMP WAS PUMPING AT 20 PSI AND #2 FIRE PUMP WAS 45 PSI.
Amended 11OCT2019: Replace temporary portable fire pump with permanently installed fire pump IAW ships design.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 September 2019
Resolved
WHEN A DECK SCUTTLE SERVES AS A MEANS OF ESCAPE, IT MUST NOT BE LESS THAN 18 INCHES IN DIAMETER AND MUST BE FITTED WITH A QUICK ACTING RELEASE AND A HOLD BACK DEVICE TO HOLD THE SCUTTLE IN AN OPEN POSITION. THE EMERGENCY ESCAPE SCUTTLE FROM THE ACCOMODATION SPACE IS NOT FITTED WITH A HOLD BACK DEVICE. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS BELOW THE MAIN DECK.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 September 2019
Resolved
A HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT, EXCEPT THAT THE FOLLOWING HATCHES MUST BE WEATHERTIGHT. THE QUICK ACTING CLOSING DEVISE FOR THE EMERGENCY ESCAPE HATCH DOES NOT FULLY SECURE AS DESIGNED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 September 2019
Resolved
EACH VESSEL MUST HAVE ADEQUATE EMERGENCY LIGHTING FITTED ALONG THE LINE OF ESCAPE TO THE MAIN DECK FROM ALL PASSENGER AND CREW ACCOMMODATION SPACES BELOW THE MAIN DECK. THE VOID AND LADDER BELOW THE WHEELHOUSE FOR THE EMERGENCY ESCAPE ROUTE IS NOT EQUIPPED WITH EMERGENCY LIGHTING. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS BELOW THE MAIN DECK
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 September 2019
Resolved
ALL VESSELS WITH OVERNIGHT ACCOMMODATIONS MUST BE EQUIPPED WITH A GENERAL ALARM SYSTEM. THE GENERAL ALARM BELL LOCATED IN THE ACCOMODATION SPACE PASSAGEWAY IS INOPERABLE. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS BELOW THE MAIN DECK.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 September 2019
Resolved
ON A VESSEL MORE THAN 65 FEET, THE PUBLIC ADDRESS SYSTEM MUST BE A FIXED INSTALLATION AND BE AUDIBLE DURING NORMAL OPERATING CONDITIONS THROUGHOUT THE ACCOMMODATION SPACES AND ALL OTHER SPACES NORMALLY MANNED BY CREW MEMBERS. THE ENGINE ROOM'S PUBLIC ADDRESS SYSTEM IS NOT FUNCTIONING AS REQUIRED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 September 2019
Resolved
A HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT. THE HATCH FROM THE ENGINE ROOM AND LAZARETTE IS LEAKING WATER.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2019
Resolved
A HINGED WATERTIGHT BULKHEAD DOOR MUST BE FITTED WITH A QUICK ACTION CLOSING DEVISE OPERABLE FROM BOTH SIDES OF THE DOOR AND INDICATOR LIGHTS AT THE OPERATING STATION SHOWING WHETHER THE DOOR IS OPEN OR CLOSED. THE INDICATOR LIGHTS FOR THE ACCOMMODATION SPACE AND ENGINE ROOM WATERTIGHT DOORS ARE NOT OPERATING AS DESIGNED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2019
Resolved
VITAL SYSTEMS ARE THOSE SYSTEMS THAT ARE VITAL TO A VESSEL'S SURVIVALBILITY AND SAFETY. THE VESSEL IS LEAKING AIR FROM THE AIR SYSTEM AND PREVENTING THE AIR COMPRESSOR FROM SHUTTING OFF AS DESIGNED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2019
Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION THE BILGES AND OTHER SPACES MAY BE EXAMINED TO SEE THAT THERE IS NO EXCESSIVE ACCUMULATION OF OIL, TRASH, DEBRIS, OR OTHER MATTER THAT MIGHT CREATE A FIRE HAZARD, CLOG BILGE PUMPING SYSTEMS. THE ENGINE ROOM'S BILGE CONTAINS EXCESSIVE AMOUNT OF OIL AND WATER.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2019
Resolved
COMPLETE BUT SIMPLE INSTRUCTIONS FOR THE OPERATION OF A FIXED GAS FIRE EXTINGUISHING SYSTEM MUST BE LOCATED IN A CONSPICIOUS PLACE AT OR NEAR EACH PULL BOX AND STOP VALVE CONTROL AND IN THE SPACE WHERE THE EXTINGUISHING AGENT CYLINDERS ARE STORED. THE FIXED FIREFIGHTINING SYSTEM FOR THE ENGINE ROOM IS MISSING INSTRUCTIONS FOR OPERATIONS AT THE LOCAL CONTROL.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2019
Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, AND OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS, INCLUDING FIRE, CAUSED BY OR ORIGINATING IN ELECTRICAL EQUIPMENT. MULTIPLE DEAD END WIRES FOUND IN A/C DUCT SPACE BELOW OPERATING STATION.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2019
Resolved
EACH CONNECTION TO A CONDUCTOR OR TERMINAL PART OF A CONDUCTOR MUST BE MADE WITHIN A ENCLOSURE AND HAVE EITHER A PRESSURE TYPE CONNECTOR, A SOLDER LUG, A SPLICE MADE WITH A PRESSURE TYPE CONNECTOR TO A FLEXIBLE LEAD OR A SPLICE THAT IS SOLDERED, BRAZED, OR WELDED TO A FLEXIBLE LEAD OR CONDUCTOR. MULTIPLE EQUIPMENTS POWER SOURCE BELOW THE OPERATION STATION ARE TEMPORARY AND NOT IN A PERMANENT ENCLOSURE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2019
Resolved
ALL ELECTRICAL EQUIPMENT AND CIRCUITS MUST BE CLEARLY MARKED AND IDENTIFIED. THE CIRCUIT BREAKERS IN THE ELECTRICAL PANEL FOR THE OPERATING STATION AND ENGINE ROOM SECONDARY PANEL ARE NOT CLEARLY MARKED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2019
Resolved
EACH OVERNIGHT ACCOMMODATION SPACE ON A VESSEL WITH OVERNIGHT ACCOMMODATIONS FOR PASSENGERS MUST BE FITTED WITH AN INDEPENDANT MODULAR SMOKE DETECTION AND ALARM UNIT. THE SMOKE ALARM N THE ACCOMMODATION SPACE BATHROOM IS NOT PROPERLY MOUNTED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 September 2019
Resolved
A VESSEL IS INSPECTED FOR COMPLIANCE WITH THE STANDARDS REQUIRED BY THIS SUBCHAPTER. MACHINERY, EQUIPMENT, MATERIALS, AND ARRANGEMENTS NOT COVERED BY STANDARDS IN THIS SUBCHAPTER MAY BE INSPECTED IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO THE COGNIZANT OCMI AS GOOD MARINE PRACTICE. THE FORWARD ACCOMMODATION DECK FRAMING NEEDS TO BE SECURED TO PREVENT PASSENGERS FROM TRIPPING OR FALLING THROUGH. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS BELOW THE MAIN DECK.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 September 2019
Resolved
EACH BATTERY USED IN AN ITEM OF LIFESAVING EQUIPMENT, EXCEPT INFLATABLE SURVIVAL CRAFT EQUIPMENT, MUST BE REPLACED DURING THE ANNUAL INSPECTION IF THE EXPIRATION OF THE BATTERY HAS PASSED. THE BATTERIES ON BOTH LIFE FLOATS ARE NOT THE APPROVED TYPE. THE VESSEL IS RESTRICTED TO DAY TIME OPERATIONS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2019
Resolved
EACH SURVIVAL CRAFT MUST BE PROVIDED WITH MEANS TO PREVENT FROM SHIFTING. THE PLATFORM BRACKET FOR BOTH LIFE FLOATS ARE CRACKED.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 September 2019
Resolved
THE EMERGENCY LIGHTING MUST AUTOMATICALLY ACTUATE UPON FAILURE OF THE MAIN LIGHTING SYSTEM. THE EMERGENCY LIGHTING THROUGHOUT THE ACCOMMODATION SPACES AND ENGINE ROOM FAILED TO ILLUMINATE UPON LOSS OF POWER. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS BELOW THE MAIN DECK.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 January 2019
Resolved
Hoses on Fixed fire extinguisher system (CO2) is not in satisfactory conditions. Found two nonmetallic hose with 90 deg bent and frayed outer protective layer. Realigned and replace damaged hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 15 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 27 January 2019
Resolved
Install missing air duct panel in port engine room ventilation duct.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2019
Resolved
Make proper wire connection in fuse panel forward engine room build head.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2019
Resolved
Install missing gauge and cover on #1 generator gauge panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Repair salt water leaks on salt water pumps for #1 , #2 & #3 propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 January 2019
Resolved
Repair all identified inoperable lights in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 January 2019
Resolved
Post operation instruction and diagram for fixed fire extinguisher system by activation station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Replace damaged breather hose on starboard propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 January 2019
Resolved
Install missing cover for overhead light outboard of port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install missing lagging on Propulsion engine exhaust pipe and turbo charger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2019
Resolved
Prepare (02) pressure vessel (star air accumulation tanks) for internal exams.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install missing cooling water (salt water) flow alarm on starboard engine and install cover for the same alarm on middle engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install proper cutter pin on reduction gear control cables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Realign flexible hose on port engine air booster inlet pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Repair and show proper operation of engine control for middle engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2019
Resolved 15 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install missing flywheel housing cover on starboard engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install support bracket for starboard engine cooling pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Replace deteriorated hose on starboard engine breather.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Replace deteriorated lube oil hose on middle engine turbocharger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Install chafing gear on lube oil hose middle engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2019
Resolved
Replace frayed electric wire for engine room forward bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Reconnect remote reach rod for starboard fuel shut off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2019
Resolved
Replace deteriorated hose on starboard engine cooling pipe to keel cooler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2019
Resolved
Install missing push buttons on all identified equipment control boxes located engine room forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2019
Resolved
Make proper wire connection and remove all dead end wire in control box starboard engine forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 27 January 2019
Resolved
Locate and repair oil leaks from machineries and remove standing oil in the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 27 January 2019
Resolved
Found disconnected ventilation supply and exhaust ducts to forward berthing. Install ventilation ducts and show proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 27 January 2019
Resolved
Repair and install sewage macerator pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 January 2019
Resolved
Repair and show proper operations on (03) water tight doors alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 27 January 2019
Resolved
Cooking appliance shall be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 27 January 2019
Resolved
Install missing ventilation covers in accommodation spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 January 2019
Resolved
Show proper operations for PA system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 January 2019
Resolved
Repair and show proper operation for all smoke detector alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2019
Resolved
Emergency instruction must be mounted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 January 2019
Resolved
Show proper operation for single side band radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 6 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2018
Resolved
Certificate of Inspection expired on 25JUL2018. Vessel is prohibited from carrying passengers and cargo for hire until COI is completed to the satisfaction of an attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2019
Construction/Loadline › Structures › End Bulkhead
Issued 28 August 2016
Resolved
Passenger accommodations must be arranged and equipped to provide for the safety of the passenger as required by 46 CFR 177.800. Install missing ceiling and wall linings in forward most accommodation.
Due 5 September 2016
Resolved 3 September 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 August 2016
Resolved
Flexible nonmetallic hose must meet SAE J-1942 and SAE J-1475 as required by 46 CFR 182.720(e). Replace all identified rusted hydraulic hose fittings found in port galley.
Due 5 September 2016
Resolved 26 April 2019
Engineering › Fuel Oil Service System › Filter
Issued 28 August 2016
Resolved
Remove garden hose valve attached to fuel filter and install manufacture recommended metal plug. Unsafe practice as required by 46 CFR 176.830.
Due 5 September 2016
Resolved 3 September 2016
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 28 August 2016
Resolved
Engine must be water- jacket cooled as required by 46 CFR 182.420. Replace deteriorated hose.
Due 5 September 2016
Resolved 3 September 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 August 2016
Resolved
Electrical equipments must be install to maintained to minimized accidental personal contact with energized parts as required by 46 CFR 183.200. Install missing portable water pump or replace with in-kind pump. Mean time pump motor must be properly tag-out.
Due 30 September 2016
Resolved 26 April 2019
Engineering › Fuel Oil Service System › Hose
Issued 28 August 2016
Resolved
Flexible nonmetallic hose used on vital system must meet SAE J-1942 and SAE J-1475 as required by 46 CFR 182.710. Remove metal fitting installed on #2 generator fuel line and install hose that meet SAE J-1942 and SAE J-1475 standards.
Due 5 September 2016
Resolved 3 September 2016
Electrical › Electric Generation Source (service) › Generator
Issued 28 August 2016
Resolved
Each motor must have a nameplate attached to it containing the information required by article 430 of NFPA 70 as required by 46 CFR 183.320(e). Attached appropriate name plate to each motors.
Due 6 September 2016
Resolved 3 September 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 June 2014
Resolved
Provide break glass enclosure for the remote control for the fixed gas fire extinguishing system. 46 CFR 181.410 (b)(4).
Due 27 July 2014
Resolved 9 July 2014
Resolution: New break glass enclosure installed outside of engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2014
Resolved
Properly secure the electric outlet box in the forward berthing compartment.
Due 27 July 2014
Resolved 9 July 2014
Navigation › Piloting/Steering › Marine Charts
Issued 27 June 2014
Resolved
Provide up-to-date corrected charts. 46 CFR 184.420
Due 27 July 2014
Resolved 9 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2014
Resolved
Remove or properly secure dead end wire on Starboard generator.
Due 27 July 2014
Resolved 9 July 2014
Communications › Radio Communications › EPIRB
Issued 27 June 2014
Resolved
Update and maintain monthly EPIRB testing logs IAW 46 CFR 185.728(c)
Due 27 June 2014
Resolved 27 June 2014
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2012
Resolved
Make forward pilot house deck watertight as original. Vessel restricted to operation on protected waters until completed and approved.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2013
Resolution: Forward pilot house deck re-installed as original.
Construction/Loadline › Structures › Scuttle
Issued 13 July 2012
Resolved
Provide watertight emergency escape hatch from pilot house, leading into accommodation space. Vessel restricted to operation on protected waters until completed and approved.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2013
Resolution: Hatch tested and appears to be installed properly as required.
Lifesaving › Lifebuoys › Approval
Issued 13 July 2012
Resolved
Provide USCG approved ring buoys. Current buoys are SOLAS type.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 19 July 2012
Resolution: Replaced ring buoys with USCG approved type.
Fire Fighting › Fire Hoses › Condition
Issued 13 July 2012
Resolved
Replace worn fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2012
Resolution: Replaced fire hose.
Engineering › Bilge Water Management System › Valve
Issued 13 July 2012
Resolved
Provide bilge piping diagram and instructions for operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2013
Resolution: Bilge piping diagram provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 July 2012
Resolved
Provide safety guard for main steering pump shaft.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 19 July 2012
Resolution: Fabricated and installed safety guard for main steering pump shaft.
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 July 2012
Resolved
Label fuel shutoff reach rods, and label direction to close.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2012
Resolution: Labeled and demonstrated use of fuel shutoff reach rods and valves.
Engineering › Lubricating Oil Service System › Gauge
Issued 13 July 2012
Resolved
Conduct main engines' overspeed, high temp, and low lube oil pressure tests.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2013
Resolution: Overspeed trips tested satisfactory.
Stability › Watertight Integrity › General
Issued 10 July 2012
Resolved
Class 1 WTD's, one going into engine room and the other going into the fwd accommodation space, must be quick acting to be allowed for coastwise service out to 20 Nautical miles from shore.
Action required: 705 - Other - as specified
Due 10 August 2012
Resolved 18 January 2013
Resolution: Class 1 WTD installed and tested satisfactorily.
Construction/Loadline › Structures › Scuttle
Issued 9 July 2012
Resolved
Prove watertight integrity of lazarette and fore peak scuttles.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Replaced gaskets for watertight scuttles. Additionally, welded a bracket that aligns the dogging bar so that it doesn''''t spin when tightened, allowing the scuttle to be secured.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 July 2012
Resolved
Provide bridge to bridge safety radio certificate.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 8 January 2013
Resolution: Provided proof of bridge to bridge safety radio certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 July 2012
Resolved
Demonstrate proper operation of single side ban radio.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 18 January 2013
Resolution: New SSB radio installed.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 9 July 2012
Resolved
Provide updated rules of the road.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 11 July 2012
Resolution: Purchased copy of Rules of the Road.
Lifesaving › Hand Flares › Quantity
Issued 9 July 2012
Resolved
Provide 1 orange smoke or red flare distress signal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Provided additional flare.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 July 2012
Resolved
Replace navigation light bulbs with approved type, prior to night-time operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2012
Resolution: Replaced navigation light fixtures with approved type.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 July 2012
Resolved
Replace mast head light fixture.
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 19 July 2012
Resolution: Replaced mast head light fixture.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 July 2012
Resolved
Provide aspirin for first aid kit.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 11 July 2012
Resolution: Provided asprin for first aid kit.
Construction/Loadline › Structures › Door
Issued 9 July 2012
Resolved
Repair engine room WTD indicator switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Proved proper operation of engine room WDT indicator switch
Navigation › Piloting/Steering › Swing Meter
Issued 9 July 2012
Resolved
Repair rudder angle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Proved proper operation of rudder angle indicator.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 9 July 2012
Resolved
Provide lights for all child PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Installed lights on all child PFDs.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 July 2012
Resolved
Provide pins for engine vent covers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Provided bolts to hold engine room ventilation covers closed. Proved closure of the ventilation ducts.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 July 2012
Resolved
Properly bundle ring buoy life line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Ring buoy life line arranged to allow the line to pay out when thrown.
Engineering › Bilge Water Management System › Not Operational
Issued 9 July 2012
Resolved
Prove proper operation of bilge main.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2013
Resolution: Bilge system tested and proper operation observed.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 July 2012
Resolved
Replace cracked and broken light fixtures in engine room.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 8 January 2013
Resolution: Cracked and broken light fixtures were repaired or replaced as required.
Engineering › Bilge Water Management System › Strainer
Issued 9 July 2012
Resolved
Provide proper strainer for E/R bilge suction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2012
Resolution: Fabricated, installed, and satisfactorily tested properly sized E/R bilge suction foot.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 July 2012
Resolved
Make proper repairs to electrical cable splices and remove dead ended cables from engine room.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 19 July 2012
Resolution: Proper repairs made, dead ended cables removed from engine room.
Stability › Watertight Integrity › General
Issued 9 July 2012
Resolved
Remove old copper tubing from forward E/R bulkhead stbd side and seal opening watertight.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 19 July 2012
Resolution: Removed unused copper tubing from forward E/R bulkhead, and sealed.
Stability › Watertight Integrity › General
Issued 9 July 2012
Resolved
Prove watertight integrity of both watertight doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Made adjustments to dogs on watertight doors, and proved seal with chalk test.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 9 July 2012
Resolved
Prove proper operation of all smoke detectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Provided batteries for smoke detectors and proved operation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 July 2012
Resolved
Secure engine room deck plating.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 19 July 2012
Resolution: E/R deck plating secured.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 July 2012
Resolved
Provide adequate emergency lighting for below deck accommodation spaces and engine room.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 18 January 2013
Resolution: Emergency lighting batteries replaced and tested satisfactorily.
Fire Fighting › Nozzles › Number
Issued 9 July 2012
Resolved
Provide nozzle for stbd fire station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2012
Resolution: Provided nozzle for second fire hose and proved operation.
Lifesaving › Lifefloat › Serviceable
Issued 9 July 2012
Resolved
Renew survival craft with new life float or inflatable life raft.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 20 August 2013
Resolution: New survival craft were installed onboard vessel.
Stability › Watertight Integrity › General
Issued 9 July 2012
Resolved
Provide "Door to remain closed while underway" signs on WTD's
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 11 July 2012
Resolution: Provided proper signs for watertight doors.
Engineering › Reduction Gearing/Clutches › Pinion
Issued 12 December 2011
Resolved
Vessel suffered broken piston spring on transmission control valve.
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 20 December 2011
Resolution: VSL crew replaced reduction gear control valve spring with new spring assembly (Part# XA2707BU). Conducted satisfactory underway operational test.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 July 2011
Resolved
Vessel lost starboard engine due to leak on salt water cooling system which caused engine to overheat. Repair cooling water system and conduct operational test on STBD engine witness by MI.
Action required: 705 - Other - as specified
Resolved 21 November 2011
Lifesaving › Hand Flares › Expired
Issued 4 February 2011
Resolved
Found expired six red flares ( 20JAN11). Replace all expired red flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 February 2011
Resolved
Found damaged gaskets on FWD watertight hatch to FWD peak, weather tight door to passenger cabin and watertight hatch to steering space. Replace all indicated gaskets.
Due 19 February 2011
Resolved 17 February 2011
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 4 February 2011
Resolved
Found discharge pressure gauge on #1 Fuel transfer pump missing protective face cover, exposing internal mechanism. Replace damaged pressure gauge.
Due 19 February 2011
Resolved 17 February 2011
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 February 2011
Resolved
Found two through holes bottom of the watertight bulkhead FWD of Captain's cabin. Make permanent plug/seal on openning.
Due 19 February 2011
Resolved 17 February 2011
Communications › Public Address System › Amplifier
Issued 4 February 2011
Resolved
Found inoperable PA system. Repair vessel's PA system.
Due 19 February 2011
Resolved 17 February 2011
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 4 February 2011
Resolved
Found vessel with no current notices to mariners. Provide current copies of local notices to mariners.
Due 19 February 2011
Resolved 17 February 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 February 2011
Resolved
Found main battery storage box containing liquid substances. Remove liquid substance and clean battery storage box.
Due 19 February 2011
Resolved 17 February 2011
Communications › Alarms/Indicators › General Alarm
Issued 4 February 2011
Resolved
Found inoperable smoke alarm in port berthing. Repair smoke alarm.
Due 19 February 2011
Resolved 17 February 2011
Communications › Alarms/Indicators › General Alarm
Issued 4 February 2011
Resolved
Found inoperable audible general alarm in engine room. Repair alarm
Due 19 February 2011
Resolved 17 February 2011
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 4 February 2011
Resolved
Found rudder angle indicator mechanically disconnected. Conduct repairs as original.
Due 19 February 2011
Resolved 17 February 2011
Lifesaving › Lifefloat › Lifeline
Issued 17 February 2010
Resolved
Found temporary repairs on lifeline retainer attached to life float. Repair or replace lifeline retainer IAW [name withheld] recommendation.
Due 31 March 2010
Resolved 26 February 2010
Communications › Radio Communications › EPIRB
Issued 17 February 2010
Resolved
Found EPIRB location with obstruction that will prevent EPIRB from free float. Relocate EPIRB to have free float ability.
Due 3 March 2010
Resolved 26 March 2010
Construction/Loadline › Structures › End Bulkhead
Issued 17 February 2010
Resolved
Found a 3"x2" hole upper port to passenger entrance watertight door. Repair hole on the bulkhead.
Due 3 March 2010
Resolved 26 February 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 17 February 2010
Resolved
Found missing locking nut on governor control link. Install locking nut.
Due 3 March 2010
Resolved 26 February 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 February 2010
Resolved
Found a chafed exhaust cooling non metallic hose on starboard engine. Install chafing gear on exhaust cooling hose.
Due 3 March 2010
Resolved 26 February 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 February 2010
Resolved
Found missing guard protection on port air compressor wheel and drive belt. Install guard for rotating mechanism.
Due 3 March 2010
Resolved 26 February 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 February 2010
Resolved
Found a 40 watt house hold light buld installed in port side running nav light. Install nav light the meet UL 1104 standard.
Due 3 March 2010
Resolved 26 February 2010
Construction/Loadline › Hull › Side Shell
Issued 25 January 2010
Resolved
Insert port side shell in away of berthing area. Insert will be minimun of 18" x 18". Insert to cross one frame space and have radius corners.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Hull › Side Shell
Issued 25 January 2010
Resolved
Insert port shell engine room outboard of port engine. Insert will be at minimun 18" x 18", cross one frame space with radius corners. IAW NVIC 7-53.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2010
Resolved
Repair cracked weld on port upper aft corner in lazarette.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Hull › Weld
Issued 25 January 2010
Resolved
Repair cracked weld on steering ram mount support.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Structures › Scuttle
Issued 25 January 2010
Resolved
Replace gasket and install captive device on hatch to lazarette.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Structures › Scuttle
Issued 25 January 2010
Resolved
Install captive device on hatch to forepeak.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 25 January 2010
Resolved
Repair cracked weld upper port engine room mid section.
Due 8 February 2010
Resolved 5 February 2010
Construction/Loadline › Hull › Weld
Issued 25 January 2010
Resolved
Repair cracked weld on center engine mount below reduction gear.
Due 8 February 2010
Resolved 2 February 2010
Construction/Loadline › Structures › Door
Issued 25 January 2010
Resolved
Replace gasket on water tight door to passenger seating area.
Due 8 February 2010
Resolved 2 February 2010
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 25 January 2010
Resolved
Replace non metallic hose on keel cool system to port engine.
Due 8 February 2010
Resolved 2 February 2010
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 February 2009
Resolved
Prepare port and stbd air receivers for internal visual inspection including test of pressure relief valve.
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 5 March 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 18 February 2009
Resolved
Renew coating on one B-II fire extinguisher where rusted. NFPA 10.
Due 18 March 2009
Resolved 5 March 2009
Engineering › Bilge Water Management System › Piping
Issued 18 February 2009
Resolved
Prove proper operation of valve at forepeak bilge suction pipe.
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 5 March 2009
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 18 February 2009
Resolved
Renew breather hose at port engine where temp repair exists.
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 5 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 9 October 2007
Resolved
Make permanent repairs to aft bulkhead in steering gear room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Permanent repairs made.
Engineering › Fuel Oil Service System › Piping
Issued 9 October 2007
Resolved
Install brackets on fuel oil piping for both generators.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Brackets installed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 October 2007
Resolved
Install brackets on jacket water piping for both generators.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Brackets installed.
Electrical › Electric Supply System (service) › Cable
Issued 9 October 2007
Resolved
Install junction box for wire splice inside starboard exhaust vent.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Wires properly installed in junction box.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 9 October 2007
Resolved
Replace broken sight glass for aft fuel oil tank.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: New sightglass installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 October 2007
Resolved
Install missing bolts in access cover for steering gear/ generator room.
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: Bolt holes were tapped so no nut or washer are required.
Construction/Loadline › Hull › Stringer
Issued 9 October 2007
Resolved
Back gouge and reweld several fractured welds port and starboard side of engine room.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All fractures repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 October 2007
Resolved
Repair jacket water leak from starboard main engine outboard exhaust manifold.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Cracks found in manifold were welded and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 9 October 2007
Resolved
Replace leaking lube oil hose to starboard main engine turbocharger.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All hoses were replaced.
Engineering › Lubricating Oil Service System › Gauge
Issued 9 October 2007
Resolved
Install brackets for gauge lines on port & stbd main diesel engines.
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: Brackets installed on both main engines.
Electrical › Electric Supply System (service) › Cable
Issued 9 October 2007
Resolved
Reroute and properly mount wire for fresh water pump.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Wire is porperly routed and mounted.
Electrical › Electric Supply System (service) › Cable
Issued 9 October 2007
Resolved
Install proper bulkhead penetrations through watertight bulkheads.
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: All bulkhead penetration were repaired or replaced with proper fittings.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 October 2007
Resolved
Install proper bulkhead penetrations for air and hydraulic piping runnuing through watertight bulkheads.
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: Proper bulkhead penetrations were installed.
Engineering › Fuel Oil Service System › Hose
Issued 9 October 2007
Resolved
Properly install fuel oil hose for port main engine filter.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: A new hose and proper fitting were installed.
Fire Fighting › Fire Main › Condition
Issued 9 October 2007
Resolved
Properly mount priming hose between bilge and fire pump.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Hose is properly installed with proper backets.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 October 2007
Resolved
Install metal brackets for wire runs on both port and starboard sides of vessel.
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: All wire runs have proper metal brackets installed.
Engineering › Lubricating Oil Service System › Hose
Issued 9 October 2007
Resolved
Replace all vital system hoses over 60 inches long with piping and shorter hoses.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Piping was installed to shorten hose runs to 60 inches. All fuel and oil hoses in the engine room were replaced.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 October 2007
Resolved
Install brackets on center main engine keel cooler piping.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: Brackets installed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 9 October 2007
Resolved
Properly deadend wires throughout vessel; either by removing or place in junction box.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All dead end wires were removed.
Engineering › Feedwater/Condensate Water System › Piping
Issued 9 October 2007
Resolved
Remove unused piping and hoses.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: All unused piping and hoses were removed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 October 2007
Resolved
Replace floating line attached to stbd aft lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 30 April 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 October 2007
Resolved
Perform test and record deviation beween compass and GPS, place deviation table onboard near compass.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 30 April 2008
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 9 October 2007
Resolved
Repair minor oil leak on center main engine reduction gear valve.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 30 April 2008
Lifesaving › Buoyant Apparatus › Marking
Issued 9 October 2007
Resolved
Permanently mark paddle for buoyant apparatus with vessel name.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 9 October 2007
Personnel › Training › First Aid/CPR
Issued 15 March 2007
Resolved
Found 50% of the crew not current with first aid and CPR training. Prove 50% of the crew has current training.
Due 15 April 2007
Resolved 24 April 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 March 2007
Resolved
Found magnetic compass broken. Replace magnetic compass and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Communications › Visual Communication › Warning Sign (gangway)
Issued 15 March 2007
Resolved
Found emergency exit sign posted on hatch leading to compartment below pilot house. Remove emergency exit sign.
Due 15 April 2007
Resolved 19 March 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2007
Resolved
Found VHF radio in aft pilot house not in serviceable condition. Repair or remove VHF radio.
Due 15 April 2007
Resolved 24 April 2007
Communications › Internal Communications System › Engine Order Telegraph System
Issued 15 March 2007
Resolved
Found engine room communications system not operational. Prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Communications › Public Address System › Announcing Station
Issued 15 March 2007
Resolved
Found vessels public address system not operational. Prove proper operation of system.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 19 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found wiring for whip antenna not secured. Properly secure wiring.
Due 15 April 2007
Resolved 19 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 15 March 2007
Resolved
Found the 24 volt flood lights not operational. Prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 15 March 2007
Resolved
Found mast head lighting suffing tube not weather tight. Make stuffing tube weather tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Construction/Loadline › Structures › Superstructure
Issued 15 March 2007
Resolved
Found 1.5" hole in the aft bulkhead of the superstructure. Make weather tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 15 March 2007
Resolved
Found wiring ran through the engine room ventilation onto faintail. Remove wiring and prove proper operation of ventilation closure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Communications › Alarms/Indicators › General Alarm
Issued 15 March 2007
Resolved
Found general alarm not operational. Prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Lifesaving › Lifefloat › Markings
Issued 15 March 2007
Resolved
Found starboard lifefloat with faded markings. Re-stencil markings on lifefloat.
Due 15 April 2007
Resolved 19 March 2007
Construction/Loadline › Structures › Door
Issued 15 March 2007
Resolved
Found watertight door indicators in pilot house not operational. Prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2007
Resolved
Found port fantail life buoy without a grabline. Repair or replace life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2007
Resolved
Found grabline for starboard fantail life buoy dry rotted. Repair or replace life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2007
Resolved
Found water light lanyard without a corrosion resistant clip. Install a corrosion resistant clip.
Due 15 April 2007
Resolved 19 March 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2007
Resolved
Found life buoy waterlight not properly mounted. Properly mount waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 March 2007
Resolved
Found expired items in first aid kit. Remove and replace all expired items.
Due 15 April 2007
Resolved 19 March 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 March 2007
Resolved
Found 4 B-II portable CO2 extinguishers not serviced. Prove servicing of all portable extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 15 March 2007
Resolved
Found portable heater installed in forward berthing causing a possible fire hazzard. Remove portable heater.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Communications › Alarms/Indicators › Fire Alarm
Issued 15 March 2007
Resolved
Found all smoke alarms not operational. Prove proper operation of all smoke alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found light for stove not hard wired. Hard wire with marine grade wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Fire Fighting › Grease Extraction Hood › General
Issued 15 March 2007
Resolved
Found no grease filter on stove ventilation system causing a possible fire hazzard. Install grease filter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2007
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 15 March 2007
Resolved
Found non fire resistant countertops within 3 feet of a medium heat cooking appliance. Prove countertops meet EMSE 184 standards for fire protection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 March 2007
Resolved
Found a 1/2" hole in way of forward upper water tight bulkhead on the starboard side of the engine room. Prove bulkhead is water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 15 March 2007
Resolved
Found a lube oil leak in starboard main engine box breather hose. Repair or replace hose.
Due 15 April 2007
Resolved 24 April 2007
Engineering › Fuel Oil Service System › Hose
Issued 15 March 2007
Resolved
Found fuel system for main engines with flexble hose over 42" in length. Hard pipe fuel system except where SAE J-1942 hose is needed.
Due 30 March 2007
Resolved 24 April 2007
Engineering › Steering Gear System › Piping
Issued 15 March 2007
Resolved
Found Steering system piping under pilot station leaking oil. Repair piping.
Due 15 April 2007
Resolved 19 March 2007
Construction/Loadline › Structures › Deck Plating
Issued 15 March 2007
Resolved
Found deck in below deck storage room damage and being supported with 2 by 4 lumber. Make permanent repairs to decking.
Due 15 April 2007
Resolved 24 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 March 2007
Resolved
Found holes in water tight bulkhead for below deck storage room. Make permanent repairs to water tight bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Construction/Loadline › Structures › Door
Issued 15 March 2007
Resolved
Found all water tight doors not operational. Prove proper operation of all water tight doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 15 March 2007
Resolved
Found leaking piping under the sinking in the berthing area restroom. Repair piping.
Due 15 April 2007
Resolved 19 March 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 March 2007
Resolved
Found valve handle missing from sea chest for main generators. Repair valve handle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found dead end wires in way of generators. Remove dead end wires or end and label both ends in a junction box.
Due 15 April 2007
Resolved 24 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found dead end wires in way of starboard and center main engines. Remove dead end wires or end and label both ends in a junction box.
Due 15 April 2007
Resolved 24 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found wiring harness in way of port main engine flywheel not secured. Properly secure wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found wiring in way of engine room overhead not secured. Properly secure wiring.
Due 15 April 2007
Resolved 24 April 2007
Fire Fighting › Fire Pumps › Suction Valve
Issued 15 March 2007
Resolved
Found fire pump sea water suction piping flange missing bolts. Replace all missing bolts in flange.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 15 March 2007
Resolved
Found lighting fixture in way of starboard engine room with a broken cover. Replace lighting fixture cove.
Due 15 April 2007
Resolved 19 March 2007
Electrical › Electric Supply System (service) › Battery Charger
Issued 15 March 2007
Resolved
Found battery charger in way of pilot station with unapproved wiring. Hard wire battery charger with marine grade wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Construction/Loadline › Structures › Superstructure
Issued 15 March 2007
Resolved
Found aft bridge window cracked. Replace cracked window.
Due 15 April 2007
Resolved 24 April 2007
Construction/Loadline › Structures › Deck Plating
Issued 15 March 2007
Resolved
Found hole in way of starboard bridge deck. Make permanent repairs to deck.
Due 15 April 2007
Resolved 24 April 2007
Construction/Loadline › Structures › Superstructure
Issued 15 March 2007
Resolved
Found stuffing tubes not weather tight in way of aft bridge bulkhead. Make stuffing tubes weather tight.
Due 15 April 2007
Resolved 24 April 2007
Operations/Management › Drills/Instruction › Fire
Issued 15 March 2007
Resolved
Found crew unable to communicate properly during drills. Prove crew can properly communicte during an emergency situation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2007
Resolved
Found multiple dead end wires in way of pilot station. Remove dead end wires or end and label both ends in a junction box.
Due 15 April 2007
Resolved 24 April 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 15 March 2007
Resolved
Found lube oil pressure guage at pilot station for center main engen not operational. Prove proper operation of guage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Engineering › Compressed Air System (start air) › Compressor
Issued 15 March 2007
Resolved
Found reserve air pressure guage at pilot station for starboard main engine not operational. Prove proper operation of guage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 15 March 2007
Resolved
Found water temperature guage at pilot station for port main engine not operational. Prove proper operation of guage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 15 March 2007
Resolved
Found transmission oil guages for all main engine transmissions not properly operating. Prove proper operation of all guages.
Due 15 April 2007
Resolved 19 March 2007
Electrical › Lighting (service) › Conductor
Issued 28 March 2006
Resolved
Found non-approved wire connection to life float flood lights. Prove proper wire connection to flood lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 28 March 2006
Resolved
Found dead end wires throughout vessel including under operators control panel. Remove dead end wire throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 28 March 2006
Resolved
Found non-approved wire installed throughout the vessel. Replace all non-approved wire and cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Engineering › Compressed Air System (control) › Valve
Issued 28 March 2006
Resolved
Found both air compressor safety valves not operational. Repair or replace safety valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 25 May 2006
Engineering › Lubricating Oil Service System › Gauge
Issued 28 March 2006
Resolved
Found engine oil temperature probe not installed. Repair or replace oil temperature probe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 28 March 2006
Resolved
Found electric hot water heater safety not operational. Repair or remove hot water heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 March 2006
Resolved
Found threw bulkhead penetration not water tight. Repair all water tight threw bulkhead penetrations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 25 May 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 March 2005
Resolved
Radar Antenna not operating at reduced capacity. Vessel is limited from operating beyond three miles or with more than 49 passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 May 2005
Resolution: Winessed proper operation of Radar during Apriil visit to vessel. Vessel required to have operational radar when operating with over 49 passengers or overnight with one or more passengers.
Construction/Loadline › Hull
Issued 20 February 2004
Resolved
INSERT PORT SIDE SHELL, REPAIR CRACKED WELD AND INSUFFICIENT WELD IWO FOREPEAK. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 15 March 2004
Resolution: Completed
Construction/Loadline › Structures
Issued 20 February 2004
Resolved
INSERT PORT AFT CORNER IWO LAZARETTE. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 15 March 2004
Resolution: Completed
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 February 2004
Resolved
REPAIR CRACKED WELD ON STBD OUTBOOARD AFT MDE MOUNT. LEGACY COMPONENT DESC: Bedplate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 8 March 2004
Resolution: Completed
Construction/Loadline › Structures
Issued 20 February 2004
Resolved
HATCH/SCUTTLE COVERS, PROVIDE TETHERS FOR ALL HATCH OPENINGS AND SCUTTLES. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 8 March 2004
Resolution: Completed
Engineering › Fuel Oil Service System › Hose
Issued 20 February 2004
Resolved
REPLACE ALL DIESEL FUEL HOSES WITH SAE J-1942 APPROVED HOSES DESIGNED FOR FUEL OIL SERVICE WHICH MEET APPLICABLE FIRE STRESS GUIDELINES. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 23 December 2004
Resolution: COMPLETED.
Engineering › Fuel Oil Service System › Piping
Issued 20 February 2004
Resolved
REMOVE FUEL OIL SERVICE LINE PENETRATING WATERTIGHT BULKHEAD IWO PORT/STBD SSDG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 18 January 2006
Resolution: Verified from vessel rep that fuel oil service lines had been removed and plugged.
Engineering › Pressure Vessel
Issued 20 February 2004
Resolved
INSTALL INSERTS IWO DOUBLERS OVER REMOVED PIPING PENETRATIONS ON PORT AND STBD AIR START AIR RECEIVERS. REPAIRS MUST BE COMPLETED USING SPECIAL WELDING PROCEDURES BY A QUALIFIED WELDER CERTIFIED IN THE USE OF THOSE PROCEDURES TO COMPLETE REPAIRS. LEGACY COMPONENT DESC: Shell Plate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 15 March 2004
Resolution: Deleted. Area of built up corrosion was place of original plarard.
Unknown
Issued 10 May 1999
Resolved
Maintain a training log in accordance with 46 CFR 185.420
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 10 May 1999
Resolved
Post an emergency broadcast placard in accordance with 46 CFR 184.506
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 10 May 1999
Resolved
Remove dead end wires under bridge control console.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
Install bilge alarms in accordance with 46 CFR 182.530
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
Crop and renew a/c overboard discharge pipe.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
Vee and weld cracked weld on bracket to potable water tank located in the lazarette.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 10 May 1999
Resolved
Install a loss of cooling water alarm on engine exhausts in accordance with46 CFR 182.430
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 12 February 1992
Resolved
PROVE PROPER OPERATION OF VESSEL'S INSTALLED FIRE MONITOR TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 March 1992
Resolved 13 March 1992
Unknown
Issued 28 February 1991
Resolved
Provide onboard a FCC Radio Equipment waiver to operate over 100 NM from land.
Condition: Unknown
Due 28 February 1991
Resolved 28 February 1991
Accommodation/Occupational Safety
Issued 11 April 1989
Resolved
INSTALL EXHAUST VENTILATION LINE FROM THE MACHINERY SPACES BILGES TO THE OUTSIDE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Unknown
Issued 14 April 1987
Resolved
REPLACE THREE BROKEN WINDOWS AROUND THE PASSENGER COMPARTMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
INSTALL A MEANS TO PROPERLY SECURE THE BOW ANCHOR.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
REPLACE THE MISSING DECK PLATES IN THE ENGINE ROOM OVER THE CENTER AND PORTSHAFTS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 31 August 1984
Resolved
D1- REMOVE EXPOXY PATCH ON UPPER SEAM OF FORWARD FUEL TANK PORT SIDE AND MAKE FUEL TANK AVAILABLE FOR AIR TEST DURING NEXT SCHEDULED CREDIT DRYDOCK EXAM.
Condition: Unknown
Due 31 August 1984
Resolved 31 August 1984
Engineering
Issued 24 August 1984
Resolved
REMOVE EPOXY PATCH ON FOREWARD FUEL TANK UPPER SEAM AND CONDUCT A AIR TEST AT NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 24 August 1984
Resolved 24 August 1984
Unknown
Issued 24 August 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL BUSTER THOMPSON O.N. 590463, AND ARE TO BE COMPLIED BY 24SEP84.
Condition: Unknown
Due 24 August 1984
Resolved 24 August 1984