MAURY USCG vessel records
← All vessels

TAHOE STAR

Built
1978
Last inspected
15 May 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2024
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WYH4708
Flag
UNITED STATES
Maury page id
psix-49569

Documentation record

Registered dimensions (L × B × D)53.0 ft × 14.5 ft × 7.4 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJACKSONVILLE, FL, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAKE TAHOE, NV
Endorsements, as the file codes themcw_un
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

15 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909480
18 May 2023 Administrative Inspection · Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681283
9 May 2023 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684749
3 May 2023 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7680344
25 May 2022 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7459260
14 October 2021 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7328626
6 October 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070217
31 August 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7050286
25 July 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6766727
5 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501278
23 May 2018 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417484
29 June 2017 Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6183845
30 May 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160031
2 June 2016 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5895130

Deficiency record · 10

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
Each ring life buoy must be marked with Type II retroreflective material. No retroreflective material on vessel's ring life buoy. 46 CFR 185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 31 May 2024
Resolution: Operator provided photos of ring life buoy with retroreflective material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 May 2023 No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The vessel's generator needs to be approved by MSC to ensure it complies with 46 CFR Subchapter T regulations prior to generator usage with passengers onboard. 46 CFR 182.100
Condition: Invalid
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2023 Resolved
Employers must ensure that they and their crewmembers meet the requirements of 46 CFR 16. The vessel currently does not have a Drug & Alcohol program in place. A complete audit of the vessel's chemical testing program to be conducted prior to carriage of passengers. 46 CFR 16.210(a)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2023
Resolution: Verified drug testing program.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 May 2023 Resolved
Each survival craft should be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The vessel's painter line for the IBA was improperly installed. 46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2023
Resolution: Acquired photo of IBA weaklink.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by table 46 CFR 182.520(a) only on vessels of not more than 65 feet in length carrying not more than 49 passengers, provided that: the pump is listed by an independent laboratory as meeting the requirements in UL 1113. The vessel's submersible electric bilge pump for the vessel's forward compartment was inoperable and needs to be replaced. 46 CFR 182.520(e)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2023
Resolution: Received photo.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 19 May 2023 Resolved
A vessel with more than one passenger deck must have the public address system operable from the operating station. The vessel is missing a public address system. 46 CFR 184.610(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2023
Resolution: Received video.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first-aid kit onboard the vessel has expired. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2023
Resolution: Received photo.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. The vessel's remote fuel shutoff valve is not labeled. 46 CFR 185.608
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2023
Resolution: Verified labeling of fuel shutoff valve.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 May 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The number and size of lifejacket containers were missing on the upper deck of the vessel. 46 CFR 185.604(f)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2023
Resolution: Received photo.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023 Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least three 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. The vessel's fire buckets were missing lanyards. 46 CFR 181.610
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2023
Resolution: Verified lanyards.

Ownership record