Records from 1991 to 2025. Most recent: inspection, 12 May 2025.
Inspection history · 51
12 May 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130575
9 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909462
9 May 2023
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684813
26 May 2022
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7454906
15 March 2022
Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7417570
27 April 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179562
19 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6987078
28 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6720203
3 July 2018
Examination of Repairs · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6465361
10 May 2017
Internal Structural Exam · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138314
14 April 2017
Drydock Exam · Administrative Inspection · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6122402
29 June 2016
Internal Structural Exam · Annual Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5922476
3 September 2015
DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5238320
14 June 2012
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4444855
14 May 2012
Simplified Stability Test · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4311030
22 July 2011
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4101877
4 May 2009
Examination of Repairs · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3464008
16 June 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3325904
10 April 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3176943
20 March 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2883326
30 August 2006
Type not recorded
No type recorded · Station Lake Tahoe · USCG Southwest District (CGD-SW) · Activity 2766122
27 August 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2767259
5 June 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2383833
4 May 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353832
24 June 2004
Type not recorded
No type recorded · Station Lake Tahoe · USCG Southwest District (CGD-SW) · Activity 2119367
10 May 2004
Annual Inspection · Internal Structural Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064297
12 March 2004
In-Service Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2022722
28 October 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1937148
8 May 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1789146
20 August 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1662371
2 October 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362467
1 May 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1401527
31 October 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379219
18 August 2000
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456880
29 September 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365391
22 July 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441551
1 April 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1461960
29 September 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418404
14 October 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416571
8 April 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413149
21 March 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1103901
2 October 1996
Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1453274
25 April 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355201
5 April 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1153264
9 March 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1450969
21 February 1995
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1157013
14 December 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367250
28 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367177
13 July 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432824
28 April 1994
Uninspected Other
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362967
16 August 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 938744
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2025
Resolved
An IBA must be serviced at a facility speciffically approved by the Commandant and in accordance with servicing procedures... Vessel's IBA is currently being serviced so vessel does not have IBA or valid servicing report onboard. Vessel restricted to operations not to exceed 1 NM from shore.
46 CFR 185.730 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Accepted photos to rectify deficiency. Photos uploaded to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024
Resolved
A vessel must carry one floating waterlight. Ring buoy waterlight inoperable. Limited to daylight operations.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 18 June 2024
Resolution: Accepted photo of light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible. Engine room and forward galley fire extinguishers not properly mounted.
46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 24 May 2024
Resolution: Received photograph of fire extinguishers properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024
Resolved
The part of the exhaust between the point of cooling water injection and engine manifold must be insulated. Port and stbd main diesel engines missing exhaust insulation before water injection point.
46 CFR 182.425(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 24 May 2024
Resolution: Received photographs of installed exhaust insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2023
Resolved
A vessel must be provided with bilge pumps IAW Table 182.520(a), fixed power bilge pump. Pump mount is broken and unable to operate. Temporary repair completed, and authorized until 20 May 2023.
46CFR 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2023
Resolution: Operator repaired pump mount. Received video of pump operation; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cable and wire in the engine room is supported by zipties and shall be changed to metal supports.
46CFR183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Operator secured wires with metal supports. Provided proof of rectification via photographs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2023
Resolved
Each vessel must be arranged so that the electrical loads can be energized from two sources of electricity. Vessel's battery charger is currently in the process of being rebuilt. Install battery charger to the satisfaction of the Marine Inspector.
46CFR183.310(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 5 July 2023
Resolution: Battery charger reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2022
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and stbd bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel did not have any of the markings.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel replaced markings.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 May 2022
Resolved
A hatch cover must have securing devices and other devices to prevent its loss. Hatch on focsle is missing dogs and gasket.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel added sufficient dogs and gasket.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 May 2022
Resolved
Individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at manifold and provided with a check valve at some accessible point in the bilge line. Bilge suction line in E/R is missing a check valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 26 May 2022
Resolution: Vessel installed new check valve.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 May 2022
Resolved
Each ladder used as a means of escape must be mounted atleast 7 inches from the nearest permanent object in the back of the ladder. Ladder in lower aft accomodation space is not permanently mounted or a sufficient ladder.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel permanently mounted a sufficient ladder.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2022
Resolved
Vessel must comply with the type II subdivision and damage stability requirements of 171.070. Vessel has several holes in the chain locker bulkhead that need filled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel filled in holes sufficiently to the satisfaction of the OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 June 2020
Resolved
The inspection and maintenance of the vessel’s survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have a lifesaving maintenance log available for review. The log was created and the inspection was conducted during the annual examination. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The log was created and the inspection was conducted during the annual examination.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 June 2020
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The crew training log was not available for review. The log was created and the training was conducted during the annual examination. 46 CFR 185.420 (c)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The log was created and the training was conducted during the annual examination.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 June 2020
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. The wire connections for the electric submersible bilge pump in the Engine Room were not of the approved type and were enclosed with residential duct tape. Replace the wire connectors with an approved type IAW 46 CFR 183.340.
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Wire connections replaced IAW 46 CFR 183.340 in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 June 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release unit for the vessel’s IBA was expired. The owner replaced the hydrostatic release unit on the spot in the presence of the Marine Inspector. 46 CFR 185.740 (b)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The owner replaced the hydrostatic release unit on the spot in the presence of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 June 2019
Resolved
46 CFR 177.01-5 - The scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Multiple rails and stanchions on the main deck port side and 2nd deck port and stbd sides by the operating station have broken loose and can no longer provide support to passengers. Passengers must be prohibited from access to port side main deck until further notice. Vessel must submit repair proposal to OCMI for approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2019
Resolved 18 September 2019
Resolution: Railings have been properly repaired and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2019
Resolved
46CFR 183.05-50 - Multiple wiring installations throughout the engine room and lazarette are not in accordance with 46 CFR 183.340.Remove all dead end wires, unused wire runs, and unapproved connections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2019
Resolved 19 June 2020
Resolution: Dead end wires, unused wire runs, and unapproved connections have been removed.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 28 June 2019
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: "Emergency Exit, Keep Clear". Forward and aft emergency exit were missing label.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Emergency escape hatches have been properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2019
Resolved
On a vessel on whcih the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessels stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessels placard was incorrect in the number of passengers allowed on the upper deck and posted in the wrong location.
46 CFR 185.602(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Vessel corrected number of passengers and posted correctly
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2019
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy on the upper deck was missing retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Vessel added retroreflective tape
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2018
Resolved
REPAIRS OR ALTERATIONS TO MACHINERY OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] OF INCORRECT WIRING INSTALLATIONS OF ELECTRICAL WIRING SYSTEMS FOUND THROUGHOUT ENGINE ROOM INCLUDING WIRES RUNNING THROUGH BILGES, IMPROPER LABELING OF CIRCUIT BREAKERS, MANY INSTANCES OF WIRES JOINED WITH SCREW TYPE CONNECTORS EXPOSED TO THE ELEMENTS. FOUND INSTANCE OF LIVE WIRE IN BILGE, INSTALLATION OF CIRCUIT FOR EMACERATOR IMPROPERLY RAN AND NO OVERCURRENT PROTECTION. PROVIDE DOCUMETATION OF APPROVED ELECTRICAL INSTALLATIONS. ALL UNAPPROVED ELECTRICAL INSTALLATIONS MUST BE REMOVED OR YOU MUST SUBMIT PLANS SHOWING COMPLIANCE FOR APPROVAL. ENSURE ORIGINAL INSTALLATIONS ARE IAW 46 CFR 183 OLD T REGULATIONS. APPROVED INSTALLATIONS INSTALLED AFTER MARCH 11, 1996 MUST BE INSTALLED IAW 46 CFR 183 NEW T REGULATIONS. PROVIDE DOCUMENTATION FROM MARINE ELECTRICIAN THAT ELECTRICAL SYSTEMS ARE SAFE AND INSTALLED IAW ELECTRICAL STANDARDS LISTED IN THE CFR OR OTHER EQUIVILANT APPROVED STANDARD. 46 CFR 176.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 3 June 2019
Resolution: Received documentation from Brendan Lockamy,the service manager of Tahoe Keys Yacht Club verifiying compliance with 46 CFR 176.700.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 July 2018
Resolved
A vessel on a lakes, bays and sounds route must carry three red and three orange flares or have authorized substitutions. Flares onboard are expired. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 11 July 2018
Resolution: Purchased new approved flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2018
Resolved
A vessel must have one or more life ring buoys. Life Ring Buoy has reached end of service life. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 15 July 2018
Resolution: New ring buoy procured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018
Resolved
Fire extinguishers must be installed IAW industry standards. Fire extinguisher on flybridge is not installed with approved bracket. 46 CFR 181.120
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 20 August 2018
Resolution: Bracket Replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 July 2018
Resolved
The construction and arrangement of a vessel must allow for safe operation. Main Deck forward slowly leaking below deck. Wood decking is deteriorating. Electrical lighting cover contained water. No passengers are allowed in area of concern. Forward electrical tagged out. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 13 May 2022
Resolution: Replace deck, stop leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Hand held bilge pump has reached the end of its service life. 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 11 July 2018
Resolution: New handheld bige pump with hose extension procured.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 May 2017
Resolved
Emergency Fuel Shutoff rod is connected with plastic wire tie. Plastic Wire Tie broke during test of operation. 46 CFR 182.15-40 (b) (3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Rod was attached to valve handle with marine ss wire.
Engineering › Compressed Air System (control) › Valve
Issued 10 May 2017
Resolved
Pressure Relief valve on air compressor is not labled with MAWP. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: New pressure relief valve is installed on air compressor.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2017
Resolved
Battery terminal connections are not connected with permanent connectors.
46 CFR 183.05-20 (c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: Wing nuts were replaced with permanant type connectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2017
Resolved
Multiple wiring installations throughout Engineroom and Lazarette are not made within junction boxes and installed IAW 46 CFR 183.340. 46 CFR 183.05-50.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 19 June 2020
Resolution: Unapproved wire connections have been removed or replaced IAW 46 CFR 183.340.
Stability › Weathertight Integrity › General
Issued 10 May 2017
Resolved
Forward hatch does not seal and has a broken dog.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 19 June 2020
Resolution: FWD hatch was made watertight.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 10 May 2017
Resolved
Vessel has plastic trash containers throughout the vessel in longe areas below deck. 46 CFR 177.30-7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 15 June 2017
Resolution: Trash cans were replaced with Stainless Steel.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 10 May 2017
Resolved
Local control box for Engine is broken off mount and secured with plastic wire ties. Electronic Gear Interface Module grounding wire is not connected. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 15 June 2017
Resolution: Control Box hardware was replaced and box was remounted. Grounding Wire for Electronic Gear Interface Module was reconnected.
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2012
Resolved
Remove all extension cords in the engine room & dead end wires IAW 46CFR183.05-10
Due 20 July 2012
Resolved 15 May 2013
Resolution: Found all extension cords removed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 May 2012
Resolved
Replace face plate on 110 outlets in the galley, lounge, and engine room IAW 46CFR183.10-10
Due 20 July 2012
Resolved 1 June 2015
Resolution: Faceplates on all 110 outlets now satisfactory.
Engineering › Fuel Oil Service System › Filter
Issued 14 May 2012
Resolved
Install plugs in both fuel filter drains IAW 46CFR182.20-40
Due 18 May 2012
Resolved 14 June 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 May 2012
Resolved
Properly repair stbd side steering gear hydraulic leak IAW 46CFR182.40-1
Due 18 May 2012
Resolved 14 June 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 May 2012
Resolved
Prove proper operation of 360d anchor light IAW 46CFR183.420
Due 18 May 2012
Resolved 16 May 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 May 2012
Resolved
Replace battery in ring buoy waterlight IAW 46CFR176.808
Due 18 May 2012
Resolved 14 June 2012
Fire Fighting › Fire Bucket › Availability
Issued 14 May 2012
Resolved
Provide 3 firebuckets with labels and landyards IAW 46CFR181.610
Due 18 May 2012
Resolved 14 June 2012
Documentation › Markings/Placards › Capacity Marking
Issued 14 May 2012
Resolved
Provide updated max capacity signage for the upper deck in a visible location IAW 46CFR185.602(g)
Due 18 May 2012
Resolved 14 June 2012
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 20 October 2011
Resolved 20 October 2011
Resolution: DER emailed DAPI proof of training completion.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 20 September 2011
Resolution: DER completed MIS and emailed DAPI a copy.
Construction/Loadline › Hull › Bottom Plating
Issued 4 May 2009
Resolved
Provide repair proposal for wasted / coroded bottom plating on starboard side aft, below cabinets in master stateroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Construction/Loadline › Hull › Bottom Plating
Issued 4 May 2009
Resolved
Provide gauging report for item #1 wasted areas, expanding the gauging to good metal. To include the entire hull providing an adequate sample of the condition of all hull areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2009
Resolution: Preliminary report this date. Final report dated June 20, 2009 was received on September 20, 2009. Satisfactory.
Engineering › Pressure Vessel › Relief Valve
Issued 10 April 2008
Resolved
Replace safety relief valve on the water heater in engine room IAW 46 CFR 182.320.
Due 10 May 2008
Resolved 16 June 2008
Resolution: Valve replaced.
Fire Fighting › Means of Escape › Stairways
Issued 10 April 2008
Resolved
Provide a ladder or stairs for a means of escape for the engine room emergency escape hatch in aft engine room.
Due 10 May 2008
Resolved 16 June 2008
Resolution: Ladder provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 April 2008
Resolved
Repair over ride function for fixed fire system in engine room.
Due 10 May 2008
Resolved 16 June 2008
Resolution: Over ride repaired.
Stability › Watertight Integrity › General
Issued 4 May 2005
Resolved
Cap off sea valve in way of void under galley.
Action required: 705 - Other - as specified
Resolved 4 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 4 May 2005
Resolved
Provide proof that the welding cables meet requirements in 46CFR 183.340(d)(2) or renew cables to meet the requirement of 46CFR 183.340(d)(2).
Due 4 July 2005
Resolved 5 June 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 May 2005
Resolved
Provide proof that fixed fire fighting emergency shut down operates properly for both generators. Vessel is restricted from operating generator with passengers on board for hire
Action required: 705 - Other - as specified
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 20 May 2004
Resolved
Install plugs into the two holes on port side generator connection box top.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 May 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 May 2004
Resolved
Install plug in unused sea cock piping located in void space under mess deck.
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 20 May 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 May 2004
Resolved
Install cap or plug into hole in side of junction box for motor controller located engine room starboard side above starboard generator.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 May 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 May 2004
Resolved
Install cap or plug into hole in side of junction box located above port generator in engine room.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 May 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 May 2004
Resolved
Install drip proof cover to Reverse Osmosis wiring panel located in steering compartment on transom near overhead approx centerline of compartment.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 May 2004
Resolution: Operator disconnected supply wiring at both the main panelboard and at panel in steering compartment. Reverse Osmosis unit is to be removed since it is not needed on Lake Tahoe.
Construction/Loadline › Hull
Issued 12 March 2004
Resolved
Prepare and re-coat small area of hull where water had penetrated coating (stbd side, approximately 1/3 the way aft). LEGACY COMPONENT DESC: Bottom Plating
Due 12 March 2004
Resolved 13 March 2004
Construction/Loadline › Hull
Issued 12 March 2004
Resolved
Make vessel available for internal structural examination.
Due 31 May 2004
Resolved 20 May 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 March 2004
Resolved
Provide approved mounting bracket and properly mount B-I at each operating station and B-II in main salon. LEGACY COMPONENT DESC: Mounting Bracket
Due 31 May 2004
Resolved 19 May 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 March 2004
Resolved
Relocate B-II at lower operating station to aft deck area. LEGACY COMPONENT DESC: Location
Due 31 May 2004
Resolved 19 May 2004
Lifesaving › Buoyant Apparatus
Issued 12 March 2004
Resolved
Make inflatable buoyant apparatus available for inspection.
Due 31 May 2004
Resolved 19 May 2004