BLEU WAVE

BLEU WAVE is a 1966 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2025, along with 34 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 12 May 2025.

Built
1966
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBD6343
Flag
UNITED STATES
Maury page id
psix-91485

Documentation record

Registered dimensions (L × B × D)59.7 ft × 16.0 ft × 7.3 ft
Registered tonnagegross 54 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT COMPANY INC · MANITOWOC, WI, UNITED STATES · built 1966
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

12 May 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130575
9 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909462
9 May 2023 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684813
26 May 2022 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7454906
15 March 2022 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7417570
27 April 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179562
19 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6987078
28 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6720203
3 July 2018 Examination of Repairs · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6465361
10 May 2017 Internal Structural Exam · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138314
14 April 2017 Drydock Exam · Administrative Inspection · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6122402
29 June 2016 Internal Structural Exam · Annual Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5922476

Deficiency record · 34

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2025 Resolved
An IBA must be serviced at a facility speciffically approved by the Commandant and in accordance with servicing procedures... Vessel's IBA is currently being serviced so vessel does not have IBA or valid servicing report onboard. Vessel restricted to operations not to exceed 1 NM from shore. 46 CFR 185.730 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Accepted photos to rectify deficiency. Photos uploaded to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2024 Resolved
A vessel must carry one floating waterlight. Ring buoy waterlight inoperable. Limited to daylight operations. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 18 June 2024
Resolution: Accepted photo of light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible. Engine room and forward galley fire extinguishers not properly mounted. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 24 May 2024
Resolution: Received photograph of fire extinguishers properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024 Resolved
The part of the exhaust between the point of cooling water injection and engine manifold must be insulated. Port and stbd main diesel engines missing exhaust insulation before water injection point. 46 CFR 182.425(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 24 May 2024
Resolution: Received photographs of installed exhaust insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2023 Resolved
A vessel must be provided with bilge pumps IAW Table 182.520(a), fixed power bilge pump. Pump mount is broken and unable to operate. Temporary repair completed, and authorized until 20 May 2023. 46CFR 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2023
Resolution: Operator repaired pump mount. Received video of pump operation; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cable and wire in the engine room is supported by zipties and shall be changed to metal supports. 46CFR183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Operator secured wires with metal supports. Provided proof of rectification via photographs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2023 Resolved
Each vessel must be arranged so that the electrical loads can be energized from two sources of electricity. Vessel's battery charger is currently in the process of being rebuilt. Install battery charger to the satisfaction of the Marine Inspector. 46CFR183.310(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 5 July 2023
Resolution: Battery charger reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2022 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and stbd bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel did not have any of the markings.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel replaced markings.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 May 2022 Resolved
A hatch cover must have securing devices and other devices to prevent its loss. Hatch on focsle is missing dogs and gasket.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel added sufficient dogs and gasket.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 May 2022 Resolved
Individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at manifold and provided with a check valve at some accessible point in the bilge line. Bilge suction line in E/R is missing a check valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 26 May 2022
Resolution: Vessel installed new check valve.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 May 2022 Resolved
Each ladder used as a means of escape must be mounted atleast 7 inches from the nearest permanent object in the back of the ladder. Ladder in lower aft accomodation space is not permanently mounted or a sufficient ladder.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel permanently mounted a sufficient ladder.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2022 Resolved
Vessel must comply with the type II subdivision and damage stability requirements of 171.070. Vessel has several holes in the chain locker bulkhead that need filled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 14 July 2022
Resolution: Vessel filled in holes sufficiently to the satisfaction of the OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 June 2020 Resolved
The inspection and maintenance of the vessel’s survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have a lifesaving maintenance log available for review. The log was created and the inspection was conducted during the annual examination. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The log was created and the inspection was conducted during the annual examination.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 June 2020 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The crew training log was not available for review. The log was created and the training was conducted during the annual examination. 46 CFR 185.420 (c)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The log was created and the training was conducted during the annual examination.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 June 2020 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. The wire connections for the electric submersible bilge pump in the Engine Room were not of the approved type and were enclosed with residential duct tape. Replace the wire connectors with an approved type IAW 46 CFR 183.340.
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Wire connections replaced IAW 46 CFR 183.340 in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 June 2020 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release unit for the vessel’s IBA was expired. The owner replaced the hydrostatic release unit on the spot in the presence of the Marine Inspector. 46 CFR 185.740 (b)
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: The owner replaced the hydrostatic release unit on the spot in the presence of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 June 2019 Resolved
46 CFR 177.01-5 - The scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Multiple rails and stanchions on the main deck port side and 2nd deck port and stbd sides by the operating station have broken loose and can no longer provide support to passengers. Passengers must be prohibited from access to port side main deck until further notice. Vessel must submit repair proposal to OCMI for approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2019
Resolved 18 September 2019
Resolution: Railings have been properly repaired and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2019 Resolved
46CFR 183.05-50 - Multiple wiring installations throughout the engine room and lazarette are not in accordance with 46 CFR 183.340.Remove all dead end wires, unused wire runs, and unapproved connections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2019
Resolved 19 June 2020
Resolution: Dead end wires, unused wire runs, and unapproved connections have been removed.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 28 June 2019 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: "Emergency Exit, Keep Clear". Forward and aft emergency exit were missing label.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Emergency escape hatches have been properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2019 Resolved
On a vessel on whcih the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessels stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessels placard was incorrect in the number of passengers allowed on the upper deck and posted in the wrong location. 46 CFR 185.602(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Vessel corrected number of passengers and posted correctly
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2019 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy on the upper deck was missing retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 18 September 2019
Resolution: Vessel added retroreflective tape
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2018 Resolved
REPAIRS OR ALTERATIONS TO MACHINERY OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] OF INCORRECT WIRING INSTALLATIONS OF ELECTRICAL WIRING SYSTEMS FOUND THROUGHOUT ENGINE ROOM INCLUDING WIRES RUNNING THROUGH BILGES, IMPROPER LABELING OF CIRCUIT BREAKERS, MANY INSTANCES OF WIRES JOINED WITH SCREW TYPE CONNECTORS EXPOSED TO THE ELEMENTS. FOUND INSTANCE OF LIVE WIRE IN BILGE, INSTALLATION OF CIRCUIT FOR EMACERATOR IMPROPERLY RAN AND NO OVERCURRENT PROTECTION. PROVIDE DOCUMETATION OF APPROVED ELECTRICAL INSTALLATIONS. ALL UNAPPROVED ELECTRICAL INSTALLATIONS MUST BE REMOVED OR YOU MUST SUBMIT PLANS SHOWING COMPLIANCE FOR APPROVAL. ENSURE ORIGINAL INSTALLATIONS ARE IAW 46 CFR 183 OLD T REGULATIONS. APPROVED INSTALLATIONS INSTALLED AFTER MARCH 11, 1996 MUST BE INSTALLED IAW 46 CFR 183 NEW T REGULATIONS. PROVIDE DOCUMENTATION FROM MARINE ELECTRICIAN THAT ELECTRICAL SYSTEMS ARE SAFE AND INSTALLED IAW ELECTRICAL STANDARDS LISTED IN THE CFR OR OTHER EQUIVILANT APPROVED STANDARD. 46 CFR 176.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 3 June 2019
Resolution: Received documentation from Brendan Lockamy,the service manager of Tahoe Keys Yacht Club verifiying compliance with 46 CFR 176.700.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 July 2018 Resolved
A vessel on a lakes, bays and sounds route must carry three red and three orange flares or have authorized substitutions. Flares onboard are expired. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 11 July 2018
Resolution: Purchased new approved flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2018 Resolved
A vessel must have one or more life ring buoys. Life Ring Buoy has reached end of service life. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 15 July 2018
Resolution: New ring buoy procured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Fire extinguishers must be installed IAW industry standards. Fire extinguisher on flybridge is not installed with approved bracket. 46 CFR 181.120
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 20 August 2018
Resolution: Bracket Replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 July 2018 Resolved
The construction and arrangement of a vessel must allow for safe operation. Main Deck forward slowly leaking below deck. Wood decking is deteriorating. Electrical lighting cover contained water. No passengers are allowed in area of concern. Forward electrical tagged out. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 13 May 2022
Resolution: Replace deck, stop leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Hand held bilge pump has reached the end of its service life. 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 11 July 2018
Resolution: New handheld bige pump with hose extension procured.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 May 2017 Resolved
Emergency Fuel Shutoff rod is connected with plastic wire tie. Plastic Wire Tie broke during test of operation. 46 CFR 182.15-40 (b) (3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Rod was attached to valve handle with marine ss wire.
Engineering › Compressed Air System (control) › Valve
Issued 10 May 2017 Resolved
Pressure Relief valve on air compressor is not labled with MAWP. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: New pressure relief valve is installed on air compressor.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2017 Resolved
Battery terminal connections are not connected with permanent connectors. 46 CFR 183.05-20 (c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 30 May 2017
Resolution: Wing nuts were replaced with permanant type connectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2017 Resolved
Multiple wiring installations throughout Engineroom and Lazarette are not made within junction boxes and installed IAW 46 CFR 183.340. 46 CFR 183.05-50.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 19 June 2020
Resolution: Unapproved wire connections have been removed or replaced IAW 46 CFR 183.340.
Stability › Weathertight Integrity › General
Issued 10 May 2017 Resolved
Forward hatch does not seal and has a broken dog.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 19 June 2020
Resolution: FWD hatch was made watertight.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 10 May 2017 Resolved
Vessel has plastic trash containers throughout the vessel in longe areas below deck. 46 CFR 177.30-7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 15 June 2017
Resolution: Trash cans were replaced with Stainless Steel.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 10 May 2017 Resolved
Local control box for Engine is broken off mount and secured with plastic wire ties. Electronic Gear Interface Module grounding wire is not connected. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 15 June 2017
Resolution: Control Box hardware was replaced and box was remounted. Grounding Wire for Electronic Gear Interface Module was reconnected.

Ownership record