MAURY USCG vessel records Sign in
← All vessels

SUPPLIER

SUPPLIER is a 1978 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1982, most recently in September 2011, along with 68 deficiencies.

Records from 1982 to 2011. Most recent: inspection, 29 September 2011.

Built
1978
Last inspected
29 September 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7802512 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC9502
Flag
UNITED STATES
367002590, 367103130, 367606570 (licence lapsed)
Maury page id
psix-49582

Inspections, by type

…with no type recorded10
Years with a record 29 calendar years (1982–2011)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it135 - Regulatory (Subpart C or D), Net Ton
180 - Convention (Subpart B), Net Ton
199 - Regulatory (Subpart C or D), Gross Ton
506 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH3325MMSI 367606570 · expired · compulsorily equipped · granted 20 February 2014, cancelled 27 April 2024
WDC9502MMSI 367103130 · expired · compulsorily equipped · granted 30 March 2006, cancelled 4 June 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDC3099MMSI 367002590 · expired · voluntarily equipped · granted 17 December 2004, cancelled 21 February 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCW7041MMSI not assigned · expired · compulsorily equipped · granted 27 June 1996, cancelled 2 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ADDYSON MARIE Towing Vessel · MISLE 197703 · 23 June 2003 · activity 1824722WACO Offshore Supply Vessel · MISLE 44848 · 26 November 1993 · activity 40578

Inspection history · 54

29 September 2011 COI Inspection · Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4156417
27 December 2010 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3915427
13 October 2010 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3869527
4 October 2010 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3861330
29 December 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3655885
6 January 2009 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3376073
20 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3245475
13 February 2008 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3147115
15 October 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3080298
24 July 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3006049
19 July 2007 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3000533
18 July 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3006008
12 July 2006 Hull Examination · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2710366
26 September 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2502510
28 July 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2443040
2 June 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2376825
24 September 2004 MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2203271
15 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2099192
19 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978223
23 September 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1912046
23 July 2003 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1849875
23 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1824722
5 June 2003 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1815524
18 February 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1759096
30 December 2002 Administrative Inspection · MARPOL Annex V Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1738890
22 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1664819
26 June 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405222
25 July 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433699
16 February 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815837
23 November 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809791
13 September 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449236
24 July 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375445
1 May 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443857
23 July 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394591
21 June 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465260
22 May 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396305
8 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345922
31 May 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429894
15 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 857954
26 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 40578
4 June 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434012
23 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949424
10 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257443
19 July 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243733
29 June 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217674
3 March 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225334
21 July 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889695
27 August 1988 MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350657
22 August 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040370
24 July 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030823
1 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307169
27 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287060
6 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977371
26 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969852

Deficiency record · 68

Stability › Watertight Integrity › General
Issued 29 September 2011 Resolved
Proceed directly to dry dock to remove lap patch from port shaft & make available for inspection
Action required: 705 - Other - as specified
Resolved 29 September 2011
Communications › Radio Communications › EPIRB
Issued 29 September 2011 Resolved
Register EPIRB with correct call sign.
Due 29 October 2011
Resolved 5 October 2011
Stability › Weathertight Integrity › General
Issued 29 September 2011 Resolved
Renew broken window in dog house.
Due 29 October 2011
Resolved 5 October 2011
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 September 2011 Resolved
Renew port day tank ememrgency shutdown valve to stop leaks & demonstrate for MI>
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 September 2011 Resolved
Place cover on junction box over stbd MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2011 Resolved
Recover wiring on port / stbd MDE & overhead wiring in dog house. Remove bech grinder in E/R with exposed wiring,
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2011
Resolved 5 October 2011
Lifesaving › Rocket Parachute Flares › General
Issued 4 October 2010 Resolved
provide 12 red rocket flares
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2010
Resolution: 12 rocket flares provided on board for MI inspection
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 October 2010 Resolved
Prove proper operation of port o/b fuel shut off valve
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2010
Resolution: proper operaton of valve demonstrated
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 4 October 2010 Resolved
Provide metallic piping, remote shut off valve and installed pump for lube oil system. Current system is a portable pump mounted in the e/r connected directly to the lube oil tank with a flex hose and cam locks. To be corrected at dry dock
Due 11 March 2011
Resolved 3 January 2011
Stability › Watertight Integrity › General
Issued 4 October 2010 Resolved
Provide WTD indicator lights/switches for fore/aft eng room doors at next dry dock.
Due 11 March 2011
Resolved 3 January 2011
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 4 October 2010 Resolved
Provide NAVTEX receiver by required date or route is limited to 100 NM from land.
Due 4 November 2010
Resolved 29 September 2011
Operations/Management › Drills/Instruction › Abandon Ship
Issued 29 December 2009 Resolved
Conduct proper man overboard drill, vessel crew inadequately performed man overboard drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 December 2009 Resolved
Renew port nav. light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 December 2009 Resolved
Renew/repair bilge alarm on bridge, alarm does not sound on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2009
Lifesaving › Line-Throwing Appliances › Lines
Issued 29 December 2009 Resolved
Provide 500 feet of messenger line for line throwing gun.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2009 Resolved
Wire audible alarm for aft bilge high water alarm to sound alarm at vsl operating station. Also label all alarms on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Engineering › Fuel Oil Service System › Pump
Issued 6 January 2009 Resolved
Remount fuel pump control box to bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 January 2009 Resolved
Tighten port emergency fuel shutoff reachrod/valve connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Operations/Management › Drills/Instruction › Abandon Ship
Issued 6 January 2009 Resolved
Mount liferaft deployment instructions on bulkhead at embarkation area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2009 Resolved
Replace anchor navigation light bulb.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 15 October 2007 Resolved
Remove plastic trash can from e/r.
Action required: 705 - Other - as specified
Resolved 16 October 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 October 2007 Resolved
Remove portable extension cord for meter printer from e/r.
Action required: 705 - Other - as specified
Resolved 16 October 2007
Fire Fighting › Ventilation Systems › Fans
Issued 15 October 2007 Resolved
Remove portable fan from e/r or hard-wire same into emergency blower shutdown circuit.
Action required: 705 - Other - as specified
Resolved 16 October 2007
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 15 October 2007 Resolved
Replace missing dbl nuts on shaft collar studs.
Action required: 705 - Other - as specified
Resolved 16 October 2007
Construction/Loadline › Hull › Bracket
Issued 3 October 2006 Resolved
REPAIR GUSSETT ON STARBOARD RUDDER POST IN STEERING COMPARTMENT.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2006
Resolved 3 October 2006
Resolution: COMPLETED
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 September 2005 Resolved
Quantity - Missing
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Provided correct amount of lifejackets
Stability › Watertight Integrity › General
Issued 26 September 2005 Resolved
Hole in port aft rudder room vent inside port ballast tank
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Repaired hole in pipe
Construction/Loadline › Penetrations › Gasket
Issued 26 September 2005 Resolved
Wasted gaskets on three wtd's.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Renewed all gaskets as indicated on deficiency list.
Construction/Loadline › Structures › Door
Issued 26 September 2005 Resolved
Renew both main deck water tight doors to engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Renewed both water tight doors.
Construction/Loadline › Structures › Door
Issued 26 September 2005 Resolved
Adjust all dogs on all water tight doors on vsl.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: adjusted all dogs.
Construction/Loadline › Structures › Door
Issued 26 September 2005 Resolved
Provide and install 4 wtd dogging wrenches
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Installed 4 dogging wrenches on water tight doors.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 September 2005 Resolved
Install emergancy light at main switch board in engine room and repair one light in passage way.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Installed and tested both lights.
Electrical › Electric Generation Source (service) › Panelboard
Issued 26 September 2005 Resolved
Install approved electrical mat in front of main switch board in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2005
Resolved 26 September 2005
Resolution: Installed electrical mat.
Fire Fighting › Fire Main › Condition
Issued 23 September 2003 Resolved
Prior to sailing make permentant repairs to firemain Port side above Engineroom door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2003
Resolution: Piping was removed and repaired wiht installation of approx. 3 foot section of new piping.
Fire Fighting › Fire Hoses › Condition
Issued 23 September 2003 Resolved
Destroy and replace leaking fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2003
Resolution: New hose was purchased and installed.
Engineering › Steering Gear System › Linkage
Issued 23 September 2003 Resolved
Repair rudders to prevent them from making contact with rudder stops.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2004
Engineering › Fuel Oil Service System › Filter
Issued 23 September 2003 Resolved
Reinstall flame screen on racor for Stbd MDE.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2004
Engineering › Bilge Water Management System
Issued 30 December 2002 Resolved
Prove proper operation of bilge pump/piping from voids. LEGACY COMPONENT DESC: Piping
Due 31 December 2002
Resolved 31 December 2002
Communications › Alarms/Indicators
Issued 30 December 2002 Resolved
Prove proper operation of hgh level alarms and alarm panel in the engine room. LEGACY COMPONENT DESC: High Water Alarm
Due 30 December 2002
Resolved 31 December 2002
Operations/Management › Pollution
Issued 30 December 2002 Resolved
Remove standing oily water from engine room.
Due 10 January 2003
Resolved 3 January 2003
Engineering › Shafting/Propeller Arrangements
Issued 30 December 2002 Resolved
Repair packing gland to port main diesel engine. LEGACY COMPONENT DESC: Stern Gland
Due 30 December 2002
Resolved 31 December 2002
Engineering › Bilge Water Management System
Issued 30 December 2002 Resolved
Vsl crew required to conduct 15 minute rounds of engine room during transit to Mystic Pier One in Boston. Vsl is to remain there until USCG Marine Inspector clears #1 and # 5.
Due 30 December 2002
Resolved 31 December 2002
Lifesaving › Inflatable Liferafts
Issued 30 December 2002 Resolved
Replace hydostatic release unit to port liferaft. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Due 31 December 2002
Resolved 1 January 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 August 2002 Resolved
PROVIDE CURRENT LIGHT LIST.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Lifesaving › Rocket Parachute Flares
Issued 22 August 2002 Resolved
PROVIDE 12 ROCKET PARACHUTE FLARES.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 22 August 2002 Resolved
REPAIR PILOT HOUSE SOUND POWER PHONE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 August 2002 Resolved
REPAIR STARBOARD MAIN ENGINE. LEGACY COMPONENT DESC: STARTER
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 22 August 2002 Resolved
REPAIR STARBOARD MAIN ENGINE LOW LUBE OIL ALARM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Construction/Loadline › Structures
Issued 22 August 2002 Resolved
RENEW GASKET ON FORWARD WATER TIGHT HATCH. LEGACY COMPONENT DESC: HATCH
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Lifesaving › Inflatable Liferafts › Painter
Issued 22 August 2002 Resolved
PROVIDE PROPER PELICAN HOOK FOR PORT LIFERAFT.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Construction/Loadline › Structures › Door
Issued 22 August 2002 Resolved
RENEW GASKET IN CAPTAINS STATE ROOM WATER TIGHT DOOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 22 August 2002 Resolved
PROVIDE AND INSTALL A COVER FOR GALLEY HOOD LIGHT. LEGACY COMPONENT DESC: GALLEY HOOD
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2002
Resolved 23 August 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2002 Resolved
RESTOCK FIRST AID KIT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2002
Resolved 23 August 2002
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 August 2002 Resolved
REPAIR MAIN SWITCHBOARD GROUND DETECTION SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2002
Resolved 23 August 2002
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 August 2002 Resolved
REPAIR FUEL OIL LEAKS ON METER AND PIPING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Construction/Loadline › Structures › Door
Issued 22 August 2002 Resolved
REMOVE BANDS AND REPAIR DOOR AJAR SWITCHES.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Construction/Loadline › Structures › End Bulkhead
Issued 22 August 2002 Resolved
MAKE PERMANENT REPAIRS TO THE FORWARD RUDDER ROOM BULKHEAD.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 30 August 2002
Engineering › Bilge Water Management System › Valve
Issued 22 August 2002 Resolved
REPAIR FORWARD PEAK REACH ROD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 August 2002 Resolved
REPAIR PORT FUEL OIL REMOTE REACH ROD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 22 August 2002 Resolved
PROVIDE CARGO HOSE ANNUAL TESTING RESULTS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2002
Resolved 23 August 2002
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 22 August 2002 Resolved
LOCK SEWAGE VALVE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 August 2002 Resolved
REMOVE FLAMMABLES FROM DECK LOCKER OR PROVIDE PROPER LOCATION.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 22 August 2002 Resolved
PROVIDE AND INSTALL FLAME SCREENS FOR LUBE OIL AND WASTE OIL TANK VENTS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2002
Resolved 23 August 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 August 2002 Resolved
REPAIR BILGE HIGH LEVEL ALARM INDICATOR AT PILOT HOUSE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 August 2002
Documentation
Issued 13 September 1999 Resolved
PROVIDE PROOF OF NEW VERTICAL CENTER OF GRAVITY AND MAX CARGO HEIGHT CALCULATIONS OR RECALCULATE LOADING DIAGRAM TO INCLUDE NEW VERTICAL CENTER OF GRAVITY AND MAX CARGO HEIGHT ON MAIN DECK FOR STORAGE CONTAINERS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Lifesaving
Issued 13 September 1999 Resolved
DEMONSTRATE COMPLIANCE WITN 8TH CG DISTRICT POLICY FOR "RESCUE BOAT REQUIREMENTS FOR OFFSHORE SUPPLY VESSEL" DATED 12NOV98 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Documentation
Issued 4 June 1993 Resolved
PROVIDE COPY OF A CURRENTLY VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 4 July 1993
Resolved 2 July 1993
Documentation
Issued 4 June 1993 Resolved
PROVIDE EVIDENCE OF READMEASUREMENT OR OTHER CONFIRMATION OF VESSEL'S_x001C_ CURRENT TONNAGES.
Condition: Unknown
Due 4 July 1993
Resolved 2 July 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.