MAURY USCG vessel records
← All vessels

MUNNATAWKET

Built
1978
Last inspected
28 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WQZ6100
Flag
UNITED STATES
Maury page id
psix-49609

Documentation record

Registered dimensions (L × B × D)115.5 ft × 28.6 ft × 5.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFISHERS ISLAND, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

28 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8372369
13 March 2026 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8325629
13 January 2026 Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8294615
15 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8133132
6 August 2024 Plan Review (Other than "T")
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7976899
30 May 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7922557
19 April 2024 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7904821
6 March 2024 Deficiency Check · Deadweight Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875142
12 January 2024 Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7840800
2 June 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7703439
12 January 2022 Examination of Repairs · Hull Examination · Excursion Permit · Internal Structural Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7379314
20 May 2021 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7201917
12 May 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7199289
4 September 2020 Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7055218
12 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6953235
7 April 2020 Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6936309
11 November 2019 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6846357
16 May 2019 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6685595
8 February 2019 Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6622459
28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525438
8 May 2018 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6409312
28 November 2017 Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6306883
17 August 2017 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6244816
7 February 2017 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6083993
27 January 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6079704
19 May 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5884149
22 January 2016 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5801910

Deficiency record · 23

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2026 Resolved
Fire main piping must comply with 46 CFR 119. While testing fire pump, observed pin hole leak in fire main, forward portside on car deck. Repair with temporary damage control patch prior to operations. Conduct permanent repairs by June 11, 2026.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: Permanent repairs were completed. New piping installed and leak test conducted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 May 2026 Resolved
The color of the life floats must be vivid reddish orange and have 2" wide type II reflective material on each side and end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 May 2026 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Renew vessel name on one of the paddle on portside life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 May 2026 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 May 2026 Resolved
A hatch cover must:(1) Have securing devices; and(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2026 Resolved
Each vessel must be provided with bilge pumps in accordance with 46 CFR 56.50-55 in subchapter F of this chapter, with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Following bilge piping renewal, the bilge pump was unable to obtain suction from the port lazarette during operational testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2026
Resolved 13 March 2026
Resolution: Vessel rep. provided video showing the bilge being pumped from the port lazerette.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2025 Resolved
Fixed fire extinguishing system (CO2) requires annual servicing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
Resolution: Servicing was conducted; all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024 Resolved
Obtain a new stability letter or approved calculations confirming your existing stability letter remains valid prior to resuming commercial service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: MSC issued new stability letter.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 January 2024 Resolved
Submit weight change calculations for the generators and piping to Marine Safety Center to determine if stability test will be required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2023 Resolved
Child lifejackets not labled.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2023 Resolved
05 sprinkler heads on the stbd side found clogged and not fully effective.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2023
Resolution: Heads removed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 January 2022 Resolved
Repair deck under stair well forward on the car deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: Examined repair during COI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2021 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The owner failed to make the vessel available for annual inspection within three months before or after the anniversary date of issuance of the Certificate of Inspection (COI). The anniversary date of issuance was February 16, and the vessel operated with passengers for hire from May 17, 2021 to May 19, 2021 without having made the vessel available for annual inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2021
Resolution: Owner provided the vessel to the OCMI for annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2020 Resolved
EPRIB hydrostatic expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 26 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2020 Resolved
Missing required hose clamps on flexible piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 12 May 2020
Resolution: Provide evidence that missing hose clamps were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 May 2019 Resolved
Port side IBA hydrostatic release was installed upside down. Properly rid hydrostatic release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: REcieved photo from vessel rep. showing the hydorstatic release properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 May 2019 Resolved
Grab lines on life floats held together with wire and are not able to deploy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 22 May 2019
Resolution: Grab lines triced up with breakable twine.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018 Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 22 October 2018
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Float-free Link
Issued 8 May 2018 Resolved
Renew weak links on life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Weak links renrewed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 February 2018 Resolved
Missing fire stop material in wire run from car deck to accommodations deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 8 May 2018
Resolution: Fire stop installed.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 17 August 2017 Resolved
Install structural fire protection (SPF) insulation on overhead of the engine room IWO the car deck and survival craft embarkation stations. SPF boundary must meet class A-60 rating. To be completed at next scheduled yard period.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 5 February 2018
Resolution: A-Class structural fire protection install / completed in engine room.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 February 2017 Resolved
Replace 2 fire extinguisher brackets at the aft ladder on the car deck.
Due 16 March 2017
Resolved 6 April 2017
Resolution: Bracket replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 February 2017 Resolved
Replace fire extguisher bracket at the forward ladder, starboard side on the car deck.
Due 16 March 2017
Resolved 6 April 2017
Resolution: Bracket replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.