Inspection history · 27
28 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8372369
13 March 2026
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8325629
13 January 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8294615
15 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8133132
6 August 2024
Plan Review (Other than "T")
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7976899
30 May 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7922557
19 April 2024
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7904821
6 March 2024
Deficiency Check · Deadweight Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875142
12 January 2024
Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7840800
2 June 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7703439
12 January 2022
Examination of Repairs · Hull Examination · Excursion Permit · Internal Structural Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7379314
20 May 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7201917
12 May 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7199289
4 September 2020
Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7055218
12 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6953235
7 April 2020
Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6936309
11 November 2019
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6846357
16 May 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6685595
8 February 2019
Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6622459
28 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6525438
8 May 2018
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6409312
28 November 2017
Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6306883
17 August 2017
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6244816
7 February 2017
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6083993
27 January 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6079704
19 May 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5884149
22 January 2016
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5801910
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2026
Resolved
Fire main piping must comply with 46 CFR 119. While testing fire pump, observed pin hole leak in fire main, forward portside on car deck. Repair with temporary damage control patch prior to operations. Conduct permanent repairs by June 11, 2026.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: Permanent repairs were completed. New piping installed and leak test conducted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 May 2026
Resolved
The color of the life floats must be vivid reddish orange and have 2" wide type II reflective material on each side and end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 May 2026
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Renew vessel name on one of the paddle on portside life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 May 2026
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 May 2026
Resolved
A hatch cover must:(1) Have securing devices; and(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2026
Resolved 11 June 2026
Resolution: All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2026
Resolved
Each vessel must be provided with bilge pumps in accordance with 46 CFR 56.50-55 in subchapter F of this chapter, with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Following bilge piping renewal, the bilge pump was unable to obtain suction from the port lazarette during operational testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2026
Resolved 13 March 2026
Resolution: Vessel rep. provided video showing the bilge being pumped from the port lazerette.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2025
Resolved
Fixed fire extinguishing system (CO2) requires annual servicing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
Resolution: Servicing was conducted; all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024
Resolved
Obtain a new stability letter or approved calculations confirming your existing stability letter remains valid prior to resuming commercial service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: MSC issued new stability letter.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 January 2024
Resolved
Submit weight change calculations for the generators and
piping to Marine Safety Center to determine if stability
test will be required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2023
Resolved
Child lifejackets not labled.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2023
Resolved
05 sprinkler heads on the stbd side found clogged and not fully effective.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2023
Resolution: Heads removed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 January 2022
Resolved
Repair deck under stair well forward on the car deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: Examined repair during COI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The owner failed to make the vessel available for annual inspection within three months before or after the anniversary date of issuance of the Certificate of Inspection (COI). The anniversary date of issuance was February 16, and the vessel operated with passengers for hire from May 17, 2021 to May 19, 2021 without having made the vessel available for annual inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2021
Resolution: Owner provided the vessel to the OCMI for annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2020
Resolved
EPRIB hydrostatic expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 26 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2020
Resolved
Missing required hose clamps on flexible piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 12 May 2020
Resolution: Provide evidence that missing hose clamps were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 May 2019
Resolved
Port side IBA hydrostatic release was installed upside down. Properly rid hydrostatic release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: REcieved photo from vessel rep. showing the hydorstatic release properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 May 2019
Resolved
Grab lines on life floats held together with wire and are not able to deploy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 22 May 2019
Resolution: Grab lines triced up with breakable twine.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018
Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 22 October 2018
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Float-free Link
Issued 8 May 2018
Resolved
Renew weak links on life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Weak links renrewed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 February 2018
Resolved
Missing fire stop material in wire run from car deck to accommodations deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 8 May 2018
Resolution: Fire stop installed.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 17 August 2017
Resolved
Install structural fire protection (SPF) insulation on overhead of the engine room IWO the car deck and survival craft embarkation stations. SPF boundary must meet class A-60 rating. To be completed at next scheduled yard period.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 5 February 2018
Resolution: A-Class structural fire protection install / completed in engine room.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 February 2017
Resolved
Replace 2 fire extinguisher brackets at the aft ladder on the car deck.
Due 16 March 2017
Resolved 6 April 2017
Resolution: Bracket replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 February 2017
Resolved
Replace fire extguisher bracket at the forward ladder, starboard side on the car deck.
Due 16 March 2017
Resolved 6 April 2017
Resolution: Bracket replaced.