Records from 1985 to 2007. Most recent: inspection, 6 February 2007.
Documentation record
Registered dimensions (L × B × D)110.1 ft × 40.1 ft × 8.5 ft
Registered tonnagegross 351 / net 351
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFRED SETTOON INC · BELLE RIVER, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it351 - Regulatory (Subpart C or D), Net Ton
351 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
6 February 2007
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2867702
15 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 752477
14 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 200851
17 August 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 875497
29 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 201958
29 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 751925
30 March 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 855804
11 March 1994
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164574
21 December 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159858
26 November 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156719
3 September 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1154691
10 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137726
13 October 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954945
11 May 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959568
22 January 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959554
19 December 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 960139
17 October 1990
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220155
24 May 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207654
5 May 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043201
11 May 1987
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1330824
28 May 1986
Re-Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 985737
19 December 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301141
30 May 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290764
10 January 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 977134
Engineering
Issued 11 March 1994
Resolved
PROVIDE FLAME SCREEN FOR DIESEL TANK VENTS ON CRANE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 March 1994
Resolved 31 March 1994
Documentation
Issued 11 March 1994
Resolved
PROVIDE CURRENT DOCUMENTATION STICKER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 March 1994
Resolved 31 March 1994
Construction/Loadline
Issued 11 March 1994
Resolved
REPLACE OR REPAIR STRONGBACK FOR #1 STBD VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 March 1994
Resolved 31 March 1994
Documentation
Issued 11 March 1994
Resolved
ADDRESS VESSEL'S STABILITY WITH MSC REGARDING ADDED CEMENT ON WEATHER DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 13 October 1992
Resolved
PRIOR TO OPERATION OF THE SHIPS SERVICE AIR SYSTEM, DEMONSTRATE PROPER OPERATION OF PRESSURE VESSEL RELIEF VALVE, TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Accommodation/Occupational Safety
Issued 13 October 1992
Resolved
REPAIR HAND RAILING TO CRANE.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Fire Fighting
Issued 13 October 1992
Resolved
PROVIDE SERVICE REPORT THAT FIRE EXTINGUISHERS HAVE BEEN PROPERLY SERVICED.THIS ITEM TO BE ACCOMPLISHED PRIOR TO THE OPERATION OF MACHINERY.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Electrical
Issued 13 October 1992
Resolved
PROPERLY PROTECT AND SECURE ALL BATTERIES.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Lifesaving
Issued 13 October 1992
Resolved
REMOVE POLLUTION HAZARDS FROM MAIN DECK (CLEAN OIL SPILLS).
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Deck/Cargo
Issued 13 October 1992
Resolved
PROVIDE SERVICE REPORT SHOWING THAT THE CRANE HAS BEEN TESTED TO IT'S SAFE WORKING LOAD. THIS ITEM IS TO BE ACCOMPLISHED PRIOR TO THE CRANE BEING USED.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Construction/Loadline
Issued 19 December 1991
Resolved
REPAIR ALL HOLES AND MAKE WEATHERTIGHT, OVERHEAD STBD SIDE OF CRANE.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Accommodation/Occupational Safety
Issued 19 December 1991
Resolved
SECURE MICROWAVE AND REFER.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 19 December 1991
Resolved
PROVIDE 2 GLOBES AND CASES FOR INTERIOR LIGHTS IN CRANE.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 19 December 1991
Resolved
PROVIDE ELECTRICAL BOX COVER IN STORE ROOM.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Navigation
Issued 19 December 1991
Resolved
PROVIDE AND TEST RUNNING LIGHTS, VSL RESTRICTED TO DAYLIGHT OPS UNTIL ITEM IS SATISFIED.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Fire Fighting
Issued 19 December 1991
Resolved
MOUNT 1 BI FIRE EXTINGUISHER._x001C_
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 19 December 1991
Resolved
PROVIDE BOXES AND COVERS FOR ALL BATTERIES.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 5 May 1989
Resolved
PROPERLY SECURE ELECTRICAL WIRING IN THE CREW LOUNGE/STORAGE AREA BELOW DECK.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Lifesaving
Issued 5 May 1989
Resolved
PROVIDE 2 TYPE-1 LIFE PRESERVERS FOR VESSEL'S INDUSTRIAL CREW.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Accommodation/Occupational Safety
Issued 5 May 1989
Resolved
PROVE PROPER OPERATION OF THE PRESSURE RELIEF VALVE FOR THE NEWLY INSTALLEDAIR RECEIVER IN THE DECK STORES AREA; PRESSURE RELIEF SETTING SHOULD BE 200PSIG. WORKING PRESSURE OF THE AIR RECIEVER IS 200 PSIG.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 10 January 1985
Resolved
SECURINGDEVICE REQUIRED FOR HATCH FWD RAKE STBD SIDE.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Construction/Loadline
Issued 10 January 1985
Resolved
GASKETS ON ALL DECK HATCH OPENIGS REQUIRED TO BE CCLEANED.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985