Records from 1982 to 2024. Most recent: inspection, 22 November 2024.
Inspection history · 60
22 November 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8038834
15 May 2024
Drydock Extension · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7908276
20 November 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7827468
16 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7689165
28 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7643101
2 September 2022
In-Service Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7549657
21 July 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7263751
22 July 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7013415
24 October 2019
Deficiency Check · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6841624
23 October 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6853946
16 January 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610952
30 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6527803
16 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6288927
27 September 2017
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6276860
28 July 2016
MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex VI Survey · MTSA Verification · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5954905
24 February 2016
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5820758
7 October 2015
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5741117
16 October 2014
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5005470
10 March 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4813159
18 January 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4231599
27 July 2011
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4095165
17 February 2011
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3950247
10 March 2010
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3692780
12 March 2009
Hull Examination · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3430257
21 October 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3348744
19 October 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3348166
5 September 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3671423
3 July 2008
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3284479
22 July 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3022297
27 June 2007
Re-Inspection · MTSA Verification · Ballast Water Examination · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977559
31 July 2006
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731047
15 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649803
1 March 2006
Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2603267
11 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776220
1 December 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433424
5 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 763901
2 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 193190
6 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 652008
3 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 46931
7 November 1997
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402543
28 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 14461
20 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 107264
9 July 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762651
28 June 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 193189
16 May 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416494
25 November 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380699
20 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 445310
24 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188844
11 December 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374454
27 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1178962
17 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399883
28 December 1992
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 665726
7 November 1992
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 27100
6 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1010366
9 January 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262745
5 September 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941458
5 August 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934162
31 July 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938903
6 July 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889522
26 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998343
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 November 2023
Resolved
The inspection shall be such as to insure that the vessel, as regards the structure, piping, and other equipment, is in satisfactory condition and fit for the service for which it is intended.
Unable to demonstrate bilge suction. Troubleshoot and contact SecSeaDispatch to arrange inspector presence to witness bilge suction from each suction point.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2023
Resolved 28 November 2023
Resolution: Accepted video showing proper operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 20 November 2023
Resolved
To the extent necessary, the Secretary shall remeasure a vessel to which this chapter applies if—
(2) the vessel or the use of its space is changed in a way that substantially affects its tonnage.
Vessel has added portable enclosed spaces, vessel to be remeasured with an Authorized Measurement Organization by next dry dock.
46 USC 14304
81 FR 18701
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 February 2024
Resolution: Vessel obtained ABS Statement of Tonnage.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 November 2023
Resolved
The amount of carbon dioxide required for each space shall be as determined by paragraphs (b)-(d). Vessel has portable machinery spaces without fixed fire suppression.
46 CFR 95.15-5
MTN 01-04
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2024
Resolution: Activity 7908276: "Delivered approved fire and safety plan to the vessel which was moored at Ballard Oil."
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2019
Resolved
All life preservers shall be orange in accordance with subparts 160.002, or 160.055. Seven (7) life preservers had large sections approximately 10" X 8" painted black, which renders them out of specification and need to be replaced. Per 46CFR 94.40-5(Old I)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2019
Resolved 24 October 2019
Resolution: Vessel owner purchased 7 new life preservers and replaced the deficient ones upon completion of the inspection. Deficiency is corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 August 2018
Resolved
Replace 4 life buoys on board
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2018
Resolution: Inspector recieved verification that the lifebuoys had been replaced on board the vsl.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 August 2018
Resolved
Replace the hydrostatic release on the EPIRB and mark for the correct expiration date, 2 yrs from installation date.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2018
Resolution: Inspector recieved verification that the hydrostatic release for the EPIRB had been replaced on board the vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018
Resolved
Provide fuel line supports and properly install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 30 September 2018
Resolution: Verified the repairs had been made to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 28 July 2016
Resolved
Provide proper covering of electrical nonconductive matting around switchboard
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 28 July 2016
Resolution: Vessel rep provided proper noncoductive matting for the switchboard.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2016
Resolved
Windlass junction box severely corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 3 August 2016
Resolution: Replaced junction box
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 7 October 2015
Resolved
Properly service SCBA bottles.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 15 October 2015
Engineering › Pressure Vessel › Pressure Gauge
Issued 7 October 2015
Resolved
Replace gauge on port UPV in engine room.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 15 October 2015
Electrical › Electric Supply System (service) › Cable
Issued 7 October 2015
Resolved
Properly enclose wire splice on camera adjacent to aft operating station.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 15 October 2015
Accommodation/Occupational Safety › Ventilation › General
Issued 7 October 2015
Resolved
Prove proper operation of vent closure on AUV van fwd.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 15 October 2015
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 7 October 2015
Resolved
Provide adequate access to 3 fire extinguishers in stbd deck cold storage locker (doors not easily opened by one person).
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 15 October 2015
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 16 October 2014
Resolved
Generators on board can be run in parallel. As such the reverse power relay was tested and found to be inop. Demonstrate proper operation of reverse power relay prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2014
Resolution: Reverse power relay was reparied and verified by [name withheld] of ABS on behalf of the CG MI. 835 Cleared.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 October 2014
Resolved
Electrical cables were not properly supported every 24" with metal supports as required. Review all electrical runs and ensure proper supports are added as required.
Condition: Improper Installation
Due 23 October 2014
Resolved 16 October 2014
Resolution: Supports for the wiring were added while the MI was on board. 835 Cleared.
Stability › Watertight Integrity › General
Issued 16 October 2014
Resolved
The port engine room deck access WT door did not close or open properly. Installation was not water tight. Correct WT door and demonstrate proper operation in the attendance of CG or ABS inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2014
Resolution: [name withheld] with ABS witnessed proper operation of repaired WT door. 835 cleared.
Stability › Watertight Integrity › General
Issued 21 October 2008
Resolved
Repair Damage to Port side chain locker
Due 31 December 2008
Resolved 11 November 2008
Communications › Alarms/Indicators › General Alarm
Issued 3 July 2008
Resolved
Properly mark all GA alarms.
Due 3 August 2008
Resolved 31 July 2008
Stability › Severe Wind/Roll › General
Issued 3 July 2008
Resolved
Submit stability calculations, including addition of aft dog house, to MSC for approval. Supply approval letter to marine inspector.
Due 3 August 2008
Resolved 11 November 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 3 July 2008
Resolved
Provide calculations for required CO2 agent for aft paint locker.
Due 3 August 2008
Resolved 28 July 2008
Resolution: Calc''s required a 20 LB system instead of existing 10 LB system. System was upgraded and test by third party.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 3 July 2008
Resolved
Add one B-II extingusher outside of aft dog house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2008
Communications › Alarms/Indicators › General Alarm
Issued 3 July 2008
Resolved
Install GA in Unit #1 on aft deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 July 2008
Resolved
Add 2 E. lights, PFD locker, and 1 extra fire extinguisher to fire contol plan and submit for approval.
Due 3 August 2008
Resolved 31 July 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 June 2007
Resolved
Mark both engine room exits, on deck, with emergency exit keep clear.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 28 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 27 June 2007
Resolved
Repair stbd engine remote shutdown on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2007
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 27 June 2007
Resolved
Cut access holes in shelves of paint locker to allow proper distribution of CO2.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 28 June 2007
Electrical › Electric Generation Source (service) › Generator
Issued 27 June 2007
Resolved
Submit service ticket for new generator installation. Conduct test of all generator allarms, overspeed trips and reverse power relays once work is complete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2007
Construction/Loadline › Structures › Superstructure
Issued 31 July 2006
Resolved
Letter approving modification as per guidance in NVIC 10-82 required.
Action required: 705 - Other - as specified
Resolved 3 July 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 July 2006
Resolved
Update ITC tonnage during application for next COD.
Action required: 705 - Other - as specified
Resolved 3 July 2008
Construction/Loadline
Issued 1 December 1998
Resolved
REMOVE TEMPORARY SOFT PATCH FROM OVERHEAD IN E/R PASSAGEWAY AND G&W CRACK TO MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Navigation
Issued 1 December 1998
Resolved
PROVIDE DEVIATION TABLE FOR COMPASS.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving
Issued 1 December 1998
Resolved
UPDATE FIRE SAFETY PLAN.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving › Rescue Boat › Hull (rigid)
Issued 7 November 1997
Resolved
Vessel's rescue boat unservicable. Required by 46CFR133.10(c) to replace rescue boat meeting standards outlined in 46CFR133.135(a).
Condition: Unknown
Due 1 May 1999
Resolved 23 January 2007
Lifesaving
Issued 17 June 1993
Resolved
D1. PROVIDE A SUITABLE RESCUE BOAT FOR THE VESSEL'S ROUTE, OR PROVE TO THE SATISFACTION OF THE OCMI OR ATTENDING MARINE INSPECTOR SATISFACTORY OPERATION OF THE RESCUE LADDER CURRENTLY INSTALLED IN LIEU OF THE RESCUE BOAT.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 31 July 1991
Resolved
DRYDOCK VESSEL AND COMPLETED HULL REPAIR (PLATE INSERTS) IN WAY OF #3 P / SBALLAST TANKS (LOW UT READINGS) AS PER UT REPORT.
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991