SPENCER PHILIP is a 2009 offshore supply vessel. The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 37 deficiencies and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 4 March 2026.

Built
2009
Last inspected
4 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7248
921448
Flag
UNITED STATES
Maury page id
psix-921448

Documentation record

Registered dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 499 / net 149
BuilderTHOMA-SEA BOAT BUILDERS INC · HOUMA, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGOLDEN MEADOW, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
499 - Convention (Subpart B), Gross Ton
446 - Dead Weight, Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
149 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS GINGER Offshore Supply Vessel · MISLE 49620 · 22 July 2020 · activity 7013415WILKIN A FALGOUT Towing Vessel · MISLE 106896 · 22 July 2020 · activity 7013415

Inspection history · 19

4 March 2026 MTSA Verification · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8310053
10 April 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8109371
4 February 2025 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8064391
22 April 2024 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7899748
16 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7850032
9 January 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7845379
13 January 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7621199
10 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393971
12 January 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7378875
3 February 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7135454
22 July 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7013415
16 June 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6992732
9 December 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6870484
16 January 2019 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610954
7 January 2019 Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6606645
1 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6364319
16 February 2017 Periodic Inspection · Deficiency Check · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6089814
8 February 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6085048
14 March 2016 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5833479

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2026 Resolved
Pipes piercing the collision bulkhead must be fitted with valves operable from above the bulkhead deck and the valve must be fitted inside the forepeak tank adjacent to the collision bulkhead. Could not verify proper operation of bilge valve due to flush scuttle not able to be removed. 46 CFR 56.50-1(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2026
Resolved 10 March 2026
Resolution: Vessel provided a video showing movement of bilge valve from top deck.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2026 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel was not able to provide documentation showing enrollment in a drug consortium. 46 CFR 16.260(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2026
Resolved 9 March 2026
Resolution: Vessel provided documentation of vessel's enrollment in testing consortium.
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 4 February 2025 Resolved
Each vessel must have the following: A current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. The vessel's gyro compass and magnetic compass had a deviation of more than 20 degrees.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 27 February 2025
Resolution: Provided documentation showing updated compass deviation chart.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 February 2025 Resolved
Vessel has not fully implemented the requirement of the James M. Inhofe National Defense Authorization Act in regards to Master [name withheld] and Surveillance Requirements. 46 CFR 2.01-10(a) 46 USC 3106 46 USC 4901
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2025
Resolved 27 February 2025
Resolution: Provided documentation of new camera install and key control log.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2025 Resolved
If your vessel's Certificate of Inspection is renewed annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, at each inspection for certification. Vessels air receivers safety relief valve tags dated January 2019; overdue.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 27 February 2025
Resolution: Provided documentation of new safety relief valves.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 February 2025 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting. Unless a vessel is equipped with a single source of power for emergency lighting, it must have individual battery-powered lighting that is automatically actuated upon loss of normal power. Emergency lighting above the fire pump in the engine room failed to illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 27 February 2025
Resolution: Provided documentation for e-lighting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 February 2025 Resolved
Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Twist of wire connectors used to join wires to solenoids of stbd reduction gear.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Vessel operator provided pictures of proper connections and wrapped.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 April 2024 Resolved
Fore Peak has crack from collision with C-Carrier. Must submit repair preposal and have repairs inspected by marine inspector prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 26 April 2024
Resolution: Steel was repaired and documentation and photos of NDT provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 January 2024 Resolved
Each vessel must comply with 47 CFR part 80; vessel's radio with GPS coordinates was not operational on e-power. 46 CFR 130.210
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2024
Resolved 5 February 2024
Resolution: Verified radio worked on E-power.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2024 Resolved
Distribution panel must be of the dead-front type, blank missing on panel in engine room. 46 CFR 129.330
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2024
Resolved 5 February 2024
Resolution: Verified blank was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 January 2024 Resolved
Nonmetallic flexible hose of less than thirty inches (30in) may be used for flexibility; hose in fuel system was for in excess of thirty (30in) and pressure switch it led to was not permently affixed (stbd main). 46 CFR 56.60-25(b)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2024
Resolved 5 February 2024
Resolution: Sensor was moved to shorten the length of flexible hose to an adequate length.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 13 January 2023 Resolved
Vessel required to maintain valid loadline certificate. Vessel Loadline certificate not validated due to crack in watertight bulkhead at ballast tank. Repairs to be inspected by ABS Surveyor prior to issuance of loadline.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2023
Resolution: Repairs made and inspected by class. RO signed annual loadline cert
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2023 Resolved
Each lifejacket must have an approved lifejacket light. Multiple lifejacket lights were found to be expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: installed new lights
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2023 Resolved
Electrical equipment must be maintained to protect crew members from electrical hazards. Electrical junctions found open, shut downs inoperable and breakers improperly tagged out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2023
Resolved 3 February 2023
Resolution: Junction boxes sealed, breaker properly locked out, tested shutdowns sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 January 2023 Resolved
Each OSV must be provided with means for testing visual and audible alarms. Alarm panels found with missing bulbs or showing improper alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2023
Resolved 3 February 2023
Resolution: Alarm panel fixed to show proper alarms.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 February 2021 Resolved
Each OSV must carry a EPIRB that meets requirements in 47 CFR 80 and be registered with NOAA; vsl had an inoperable EPIRB; Install EPIRB w/ registration per regulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2021
Resolved 3 February 2021
Resolution: Vsl took another EPIRB from a laid up vsl and updated the registration to reflect the SPENCER PHILIP info.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 February 2021 Resolved
Pressure-indicating gauge in no case shall the upper range of the gauge be less than 1.2 times nor more than 2 times the relieving device is set; vsl had relieving device on pressure vessel at 190 and gauge max reading at 200; replace gauge to reflect correct relieving device set to function.
Action required: 10 - Deficiency Rectified
Due 3 February 2021
Resolved 3 February 2021
Resolution: Vsl replace guage to accuratly reflect range of operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2021 Resolved
Marking and stamping of Pressure Vessels: The data shall be legibly stamped and shall be maintained in a legible condition such that it may be easily read; vsl had unreadable wasted data plate; Replace to meet stated requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 25 February 2021
Resolution: Vsl had third party test PV, provided test results. Vsl could not locate original data from identical PORT PV. A metalic sticker decal was placed on PV listing MAWP, Serial number, size and year of model.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2019 Resolved
IDENTIFIED DEFECT IN STBD AIR RECIEVER. VSL REQUIRED TO HYDROSTATICALLY TEST AT 1.5X MAX ALLOWABLE WORKING PRESSURE AND GET NECESSARY REPAIRS FROM QUALIFIED WELDER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2019
Resolved 10 February 2020
Resolution: Vessel had tech remove the data plate and inspect the P/V for damage. It was concluded that the rust build up behind the data plate was only minor surface rust and did not affect the integrity of the pressure vessel. Def cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2019 Resolved
EMERGENCY LIGHTING AT MAIN DECK ENTRANCE TO HOUSE AND ENTRANCE TO ENGINE ROOM WAS OUT. REPLACE LIGHTS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 12 December 2019
Resolution: Replaced lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2019 Resolved
LIFEBOUY ON AFT DECK STBD GRAB LINE WAS DETERIORATED. REPLACE GRAB LINE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 12 December 2019
Resolution: Replaced grab line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 December 2019 Resolved
PORT GENERATOR JACKET WATER PUMP WAS LEAKING. REPAIR PUMP TO ENSURE NO COOLANT IS LEAKING.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 13 February 2020
Resolution: Recieved evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 December 2019 Resolved
REAR MAIN SEALS ON BOTH GENERATORS WERE LEAKING CAUSING OIL TO ACCUMULATE ON GENERATOR WINDINGS. RECTIFY DEFICIENCY TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 21 February 2020
Resolution: Recieved evidence of repairs.
Navigation › Piloting/Steering › Marine Charts
Issued 1 March 2018 Resolved
Provide corrected charts IAW 46 CFR 130.330.
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 3 February 2021
Resolution: VSL has up to date charts
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 1 March 2018 Resolved
Provide proof of EPA VGP NOI IAW CG Policy Letter 11-01.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 23 March 2018
Resolution: Vessel Provided Notification of enrollment in VGP.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 1 March 2018 Resolved
Provide repaired crankcase breather on starboard MDE IAW 46 CFR 58.10.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 5 March 2018
Resolution: completed repairs to breather.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 March 2018 Resolved
Provide proper marking of e- lighting IAW 46 CFR 131.480.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 1 March 2018
Resolution: Verified proper marking of e lighting.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 March 2018 Resolved
Provide proper marking of remote stopping systems IAW 46 CFR 131.896.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 1 March 2018
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 16 February 2017 Resolved
1.Prove operation of port and starboard main propulsion engines in presence of USCG Marine Inspector. IAW 46CFR130.120 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Vessel provided servicing and proved operation of engines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017 Resolved
2. Provide service to salt water pump to eliminate electrical grounding hazard to satisfaction of USCG Marine Inspector. 46CFR129.200 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Vessel locked out-tagged out equpiment and will service.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 February 2017 Resolved
3. Provide transfer procedures for fuel service system IAW 33CFR155.720,740 Prior to x-fer of fuel oil.
Action required: 705 - Other - as specified
Resolved 21 February 2017
Resolution: Vessel provided procedures.
Engineering › Steering Gear System › Actuator
Issued 16 February 2017 Resolved
4.Provide transfer procedures for steering system IAW 46CFR131.845 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Vessel provided procedures.
Communications › Internal Communications System › Sound-powered Telephone
Issued 16 February 2017 Resolved
5. Prove operation of comms to bridge from aux steering in presence of USCG Marine inspector IAW 46CFR130.440,113.30 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Vessel provided servicing and proved operation.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 February 2017 Resolved
6. Provide cableway support for cableway in engine room over escape path IAW 46CFR129.340,111.60 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Vessel provided cableway supports.
Communications › Alarms/Indicators › General Alarm
Issued 14 March 2016 Resolved
General alarm was inop on backup battery power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2016
Resolution: Vessel maitnenance manager dtermined cause to be dead accumulator battery. Battery replaced and system retested on battery backup. All sat.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (air motor)
Issued 14 March 2016 Resolved
Solenoid controller for remote starting/stopping found damaged with exposed electrical components.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 14 March 2016
Resolution: Electrical components of controller properly re-assembled and resecured to the mounting hardware. Tested sat.
Engineering › Fuel Oil Service System › Filter
Issued 14 March 2016 Resolved
Drain valves on bottom of cartridge filter cannisters found without solid bottom plugs.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 14 March 2016
Resolution: Solid plugs provided for all filter drains. All sat.

Casualty record · 1

22 July 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7013415
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.