← All vessels
WESTPORT
Industrial Vessel · Barge class · Built 1970s · USCG Northwest District (CGD-NW) · Other hulls named WESTPORT
WESTPORT is a 1978 industrial vessel. The Coast Guard has recorded 67 inspections since 1986, most recently in March 2026, along with 64 deficiencies.
Records from 1986 to 2026. Most recent: inspection, 11 March 2026.
- Built
- 1978
- Last inspected
- 11 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 64 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
592239
8993772 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WAB4086
49628
Flag
UNITED STATES
—
Maury page id
psix-49628
Inspections, by type
…with no type recorded11
Years with a record
37 calendar years (1986–2026)
The 67 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)169.0 ft × 50.0 ft × 14.0 ft
Registered tonnagegross 851 / net 255
ITC dimensions (L × B × D)169.0 ft × 50.0 ft × 14.0 ft
ITC tonnagegross 851 / net 255
BuilderZIDEL EXPLORATIONS INC · PORTLAND, OR, UNITED STATES · built 1978
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 January 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it851 - Convention (Subpart B), Gross Ton
255 - Convention (Subpart B), Net Ton
255 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspected as a tow unit · 1
The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.
GLADYS M Towing Vessel · MISLE 200884 · 18 May 2001 · activity 18005Inspection history · 67
11 March 2026
MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317554
3 January 2025
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8057240
21 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7647661
1 March 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7403903
11 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7349414
2 March 2021
Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7149746
5 March 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6916082
10 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6906486
1 March 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6631926
17 September 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6542747
6 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6362960
21 February 2017
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6088834
24 February 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821425
8 April 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5104633
12 January 2015
Internal Structural Exam · Drydock Exam · Examination of Repairs · COI Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5052195
26 November 2014
COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5030132
28 March 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4829061
14 March 2012
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4263832
24 March 2010
COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3702140
6 January 2010
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3664563
30 March 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3440282
21 March 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3169119
6 June 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2953491
2 April 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2900307
27 March 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2610678
4 April 2005
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2324610
31 January 2005
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2284008
12 April 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2042752
18 February 2003
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1741584
20 March 2002
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1495127
18 May 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 18005
20 March 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1393657
27 March 2000
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1453733
22 November 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 810325
15 June 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811207
3 December 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388657
17 December 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 781440
21 November 1997
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375191
19 August 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 783344
19 May 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386001
20 December 1996
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1095879
17 December 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 716354
6 December 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1094110
3 October 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 48640
3 October 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1147960
10 June 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1185949
18 August 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383033
20 January 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828817
2 May 1994
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861540
22 April 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1358069
16 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 716338
12 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 36105
8 April 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414128
3 December 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940533
23 November 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251185
4 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1249414
19 October 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 901188
10 September 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1218170
1 August 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916020
27 June 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1234171
14 May 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 924700
1 May 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1005397
1 May 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1045075
1 May 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245101
12 May 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348417
26 March 1987
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1326211
17 April 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1312526
Deficiency record · 64
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 November 2021
Resolved
Each vessel must undergo regular dry-docking (DDX) and internal structure exams (ISE). During the vessel's DDX and ISE several cracked welds and deflections were identified and need to be repaired. 46 CFR 91.40-3 a a list can be found on the 835 in the documents section.
Engineering › Pressure Vessel › Relief Valve
Issued 6 March 2018
Resolved
Air reciever relief valve failed test. Replace relief valve. 46 CFR 54.15-10(g)
Construction/Loadline › Structures › Door
Issued 6 March 2018
Resolved
Machinery door does not achieve watertight seal. Clean gasket and adjust dogs. Chalk test.
Engineering › Fuel Oil Service System › Filter
Issued 6 March 2018
Resolved
Engine fuel oil filter flame impingement bowls drain valve and plugs are plastic. Replace with metallic fittings.
Engineering › Fuel Oil Service System › Hose
Issued 6 March 2018
Resolved
Main gen sump drain missing fire sleeve. Install proper fire sleeve.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 1 March 2016
Resolved
Replace fuel hoses with nonmetallic flexible hose approved in accordance with SAE J1942 or cover with fire resistant sleeve on the oil lines of the generator and the hopper pump drive engine to the satisfaction of attending marine inspector.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 8 April 2015
Resolved
Vessel was issued an incorrect Coastwise Load Line Certificate by Class Surveyor that had allowance for fresh water for all freeboards of 6-1/8". Correct allowance is 3-1/8".
Construction/Loadline › Hull › Weld
Issued 14 March 2012
Resolved
Complete worklist as indicated in narrative of MISLE activity #4263832.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 6 January 2010
Resolved
3" cracked weld discovered in the #4 port void between outboard frame #3 and bottom transverse. Instructed vessel rep to repair weld.
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2010
Resolved
Port Side Rake, 6' below waterline, 2' outboard of centerline 12' x 4' insert.
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2010
Resolved
Starboard FWD rake, 6' below waterline, 8' outboard of centerline, 4 x 4' insert
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2010
Resolved
Pump room side shell, 12' x 3' insert.
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2010
Resolved
Stbd Side Void #4, 3' x 3' insert
Construction/Loadline › Hull › Bottom Plating
Issued 18 February 2003
Resolved
Crop out and renew 5' x 5' x 20lb plate insert in way of stbd bow in clam shell ram room. Renew 2 longitudinal frames.
Electrical › Lighting (service)
Issued 18 February 2003
Resolved
Renew wiring to navigation lighting in accordance with 46 CFR part 110. LEGACY COMPONENT DESC: Conductor
Electrical › Lighting (service)
Issued 18 February 2003
Resolved
Renew lighting cover in generator room in way of aft light.
Electrical › Electrical Distribution System (service)
Issued 18 February 2003
Resolved
Install main generator conductors in conduit. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 18 February 2003
Resolved
Remove temporary clips on battery chargers.
Engineering › Fuel Oil Service System
Issued 18 February 2003
Resolved
Renew fuel oil return line to aft port generator using a S AE J-9142 hose assembly. LEGACY COMPONENT DESC: Hose
Electrical › Electric Generation Source (service)
Issued 18 February 2003
Resolved
Install die-electric matting in front of switchboard.
Engineering › Fuel Oil Service System
Issued 18 February 2003
Resolved
Renew all fuel/oil & lube oil guage hoses using approved hose assemblies (SAE J-1942)
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 February 2003
Resolved
Install all fire extinguishers in approved brackets.
Navigation › Collision/Grounding Avoidance
Issued 18 February 2003
Resolved
Install correct luminaries in the restricted manuverability navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Engineering › Bilge Water Management System
Issued 18 February 2003
Resolved
Remove un-approved discharge hose on fixed bilge pump and renew as required by 46 CFR 56.50-50 LEGACY COMPONENT DESC: Hose
Construction/Loadline › Penetrations
Issued 18 February 2003
Resolved
Open up sea valve for inspection.
Construction/Loadline › Hull › Stringer
Issued 18 February 2003
Resolved
Repair as new multiple fractures in void spaces in way of longitudinals and transverse web frames.
Construction/Loadline › Structures
Issued 18 February 2003
Resolved
Renew 2 main structural I-beams in way of 5 port void as indicated by the attending inspector.
Lifesaving › Lifebuoys
Issued 18 February 2003
Resolved
Renew waterlight battery on fwd lifering buoy and add corrision resistant clip to waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Lifesaving › Lifebuoys
Issued 18 February 2003
Resolved
Properly stow, rename, and add corrosion resistant clip to waterlight on middle lifering buoy. LEGACY COMPONENT DESC: Stowage
Lifesaving › Lifebuoys
Issued 18 February 2003
Resolved
Renew middle lifering buoy waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 February 2003
Resolved
Provide B-II fire extinguisher for dredge operating station. LEGACY COMPONENT DESC: Location
Accommodation/Occupational Safety
Issued 18 February 2003
Resolved
Properly stow axcetylene and oxygen bottles on vessel.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 February 2003
Resolved
Update medical kit on vessel. LEGACY COMPONENT DESC: Medicine Chest
Lifesaving
Issued 21 November 1997
Resolved
INSTALL RETROREFLECTIVE TAPE ON RING LIFEBUOYS.
Engineering
Issued 21 November 1997
Resolved
PERFORM HYDROSTATIC TEST ON FUEL TRANSFER HOSE TO 1.5 X MAWP.
Navigation
Issued 21 November 1997
Resolved
SECURE BATTERY FOR PORT RUNNING LIGHT.
Navigation
Issued 21 November 1997
Resolved
PROVIDE PROTECTIVE COVER FOR BATTERY FOR STARBOARD RUNNING LIGHT.
Construction/Loadline
Issued 19 May 1997
Resolved
CROP AND RENEW TO GOOD METAL APPROX 6 FT OF WASTED UNDER DECK LONGITUDNAL, LOCATED AT ENTRANCE OF PORT AFT RAKE.
Lifesaving
Issued 19 May 1997
Resolved
PROVIDE VSL NAME ON ALL LIFERINGS AND MAKE ALL WATERLIGHTS OPERATIONAL.
Documentation
Issued 19 May 1997
Resolved
PROVIDE APPROVED PLANS FOR MODIFICATION OF DREDGE INCLUDING RAISING DECK HOUSE 1 1/2 FT, CHANGING OUT DECK HOUSE. PROVIDE CALCULATIONS PROVING CHANGES DO NOT EFFECT VSL STABILITY.
Electrical
Issued 19 May 1997
Resolved
PROVIDE ELECTRICAL PLANS FOR APPROVAL TO UPGRADE ELECTRICAL SYSTEMS IN PUMPROOM, UPPER AND LOWER DECK HOUSE. ELECTRICAL SYSTEMS CURRENTLY ON BOARD DO NOT MEET CFR. I.E. BROKEN ARMORED CABLE, EXTENSION CORDS, WIRE SPICES, EXTENSIVE JURY RIGS, DEAD ENDS. WIRING MUST BE REPLACED/UPGRADED.
Construction/Loadline
Issued 19 May 1997
Resolved
REMOVE WOODEN DECK IN DECK HOUSE. DECK REPLACEMENT MAY BE DELAYED FOR DECKHOUSE REPLACEMENT SCHEDULED FOR FALL 1997.
Deck/Cargo
Issued 19 May 1997
Resolved
PRESSURE RELIEF VALVE CORRODED SHUT AND WILL NOT OPEN TO RELIEVE PRESSURE.
Lifesaving
Issued 19 May 1997
Resolved
PROVIDE LIGHTS FOR ALL THREE EMERSION SUITS ONBOARD.
Lifesaving
Issued 19 May 1997
Resolved
PROVIDE 2 ADDITIONAL ADULT LIFE PRESERVERS WITH VSL NAME, LIGHTS, AND WHISTLES. PROVIDE LIGHT AND WHISTLE FOR PRESERVER ALREADY ON BOARD.
Navigation
Issued 19 May 1997
Resolved
REPLACE MISSING STERN RUNNING LIGHT AND LOWER RED RESTRICTED MANUVERING LIGHT.
Construction/Loadline
Issued 19 May 1997
Resolved
PROVIDE DYE PENATRANT CHECK OF PLATE INSERT ON THE STARBORAD SIDE JUST FWD OF ENGINE ROOM.
Documentation
Issued 19 May 1997
Resolved
PROVIDE RECEIPTS FOR ALL OILY WASTE MATERIALS DELIVERED TO WASTE RECEIPTIONFACILITY.
Construction/Loadline
Issued 20 December 1996
Resolved
REPLACE ALL WASTED/MISSING GUSSETS FOR STANCHIONS IN HOPPER AREA.
Construction/Loadline
Issued 20 December 1996
Resolved
CROP AND RENEW TO GOOD METAL ALL WASTED AREAS IN I-BEAMS SUPPORTS FOR PORT FORWARD "A" FRAME LIFT.
Accommodation/Occupational Safety
Issued 20 December 1996
Resolved
REPAIR/REPLACE ALL WASTED AND MISSING HANDRAIL STANCHIONS AS FOLLOWS; 2 STANCHIONS ON STARBOARD AFT END, STANCHION AT PORT AFT CORNER, AND 3RD, 8TH11TH AND 13TH STANCHION FROM AFT END ON PORT SIDE.
Construction/Loadline
Issued 20 December 1996
Resolved
CROP AND RENEW TO GOOD METAL AREAS OF WASTED PIPE STANCHIONS IN HOPPER AS FOLLOWS; 2ND VERTICAL STANCHION AFT, OUTBOARD ON STARBOARD SIDE, AFTMOST VERTICAL STANCHION/HORIZONTAL SUPPORT, OUTBOARD ON STARBOARD SIDE, AND 3RD STANCHION FORWARD, OUTBOARD ON PORT SIDE.
Accommodation/Occupational Safety
Issued 20 December 1996
Resolved
RENEW WASTED WALKWAY GRATING OVER HOPPER, STARBOARD SIDE, JUST FORWARD OF ENGINEROOM ENTRANCE.
Electrical
Issued 20 December 1996
Resolved
CROP AND RENEW WASTED SECTIONS OF WIRE CONDUIT FOR VESSEL'S 440 WIRING.
Accommodation/Occupational Safety
Issued 20 December 1996
Resolved
CROP AND RENEW WASTED SUPPORT MEMBERS FOR STEPS TO ELEVATED WALKWAY AT STARBOARD STERN.
Construction/Loadline
Issued 20 December 1996
Resolved
CROP AND RENEW TO GOOD METAL WASTED/DAMAGED SIDE LONGS AT 1ST AND 2ND FRAMEBACK IN #4 STARBOARD WING VOID.
Construction/Loadline
Issued 20 December 1996
Resolved
REWELD FRACTURED WELDS IN #4 STARBOARD WING VOID.
Lifesaving
Issued 20 December 1996
Resolved
RENEW WASTED WORK LIGHT STANCHIONS AS NEEDED AT ELEVATED WALKWAY OVER HOPPER.
Accommodation/Occupational Safety
Issued 20 December 1996
Resolved
REMOVE OR PROPERLY SUPPORT UPPER GRATED WALKWAY AT STARBOARD "A" FRAME.
Construction/Loadline
Issued 10 June 1996
Resolved
REPAIR CRACK ALONGSIDE OF OVERFLOW PIPE IN #2 SIDE COMPARTMENT STBD SIDE
Construction/Loadline
Issued 10 June 1996
Resolved
REWELD LONGITUDINAL TO SKIN IN #2 STBD RAKE COMPARTMENT
Unknown
Issued 18 August 1995
Resolved
PROVIDE APPROVED SHIPBOARD OIL POLUTION EMERGENCY PLAN (SOPEP) IAW MARPOL 73/78 REG 26.
Construction/Loadline
Issued 1 August 1990
Resolved
INSTALL APPROVED OILY WATER SEPERATING SYSTEM OR CONFIGURE BILGE SYSTEM IN ACCORDANCE WITH 33 CFR 155.350 AND 33 CFR 155.420. ALL OILY MIXTURES MUST BE HELD ON BOARD OR TRANSFERED TO A SHORE RECEPTION FACILITY. REFERENCE LETTER FROM MSO PUGET SOUND, SEATTLE OF 10 AUG 90 TO OWNER.
Engineering
Issued 1 May 1989
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR._x001C_