CAPT. TIBB

CAPT. TIBB is a 1978 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1981, most recently in November 2025, along with 65 deficiencies, 1 operational control and 1 casualty investigation in 2024.

Records from 1981 to 2025. Most recent: inspection, 4 November 2025.

Built
1978
Last inspected
4 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN6072
Flag
UNITED STATES
368295670
Maury page id
psix-49674

Inspections, by type

…with no type recorded5
Years with a record 40 calendar years (1981–2025)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.8 ft × 14.0 ft × 5.6 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT CANAVERAL, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6072MMSI 368295670 · active · compulsorily equipped · granted 8 February 2023, expires 8 February 2033
WDC5584MMSI 367043350 · expired · compulsorily equipped · granted 15 April 2015, cancelled 21 June 2025
WDG3536MMSI 367527060 · expired · compulsorily equipped · granted 24 April 2012, cancelled 25 June 2022
WYF5016MMSI not assigned · expired · compulsorily equipped · granted 7 January 1998, cancelled 10 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PAULA LEE Industrial Vessel · MISLE 54196 · 26 January 2024 · activity 7861443SEA CRESCENT Towing Vessel · MISLE 198552 · 26 January 2024 · activity 7861443CIANBRO FLEXI ANCHOR BARGE Freight Barge · MISLE 1816230 · 26 January 2024 · activity 7861443

Inspection history · 59

4 November 2025 Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8267435
14 October 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8251857
11 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8077811
8 January 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8059870
26 January 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7861443
18 December 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7840125
30 October 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7816388
13 January 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7621005
7 December 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7363860
21 October 2021 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7341513
21 December 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7120383
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108449
9 October 2020 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7077169
10 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6972753
3 June 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6702639
11 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6474699
2 May 2017 Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6136611
12 August 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5970840
15 July 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5184967
12 August 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4947131
10 May 2012 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4307457
18 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4227160
3 August 2011 Deficiency Check · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4102657
28 August 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3311718
11 May 2007 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2927887
21 July 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2734064
19 May 2005 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2421638
26 July 2004 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2148260
7 May 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1990991
6 May 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1614661
8 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439217
30 May 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386805
10 July 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1107161
6 May 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408301
4 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471818
15 April 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437223
15 July 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090777
30 April 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353915
25 April 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083322
25 April 1995 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403935
13 May 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428335
5 May 1993 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385069
29 June 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465720
17 October 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253783
25 September 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249087
14 May 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234217
21 May 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921585
10 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202543
5 June 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199137
28 December 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037768
27 May 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197611
15 June 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028790
10 October 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009401
4 September 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296912
18 June 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986871
15 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283651
31 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969316
12 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278222
27 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973766

Deficiency record · 65

08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 14 January 2025 Resolved
Vessels described by 46 CFR 175.110 (c) (Coastwise or Oceans routes) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. The vessel is required to install interconnected fire detectors in the accommodations space and engine room with in 60 days. 46 CFR 181.405 Code 705 c
Action required: 705 - Other - as specified
Due 13 March 2025
Resolved 11 February 2025
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 January 2025 Resolved
Oceans, Coastwise, Limited Coastwise and Great Lakes routes. A vessel must have six hand red flares approved by 160.021 and six orange flares approved by 160.037. Vessel has six red and three orange flares that have expired. Vessel is restricted to lakes, bays and sounds and rivers until flares are replaced. 46 CFR 180.68 Code 16 c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 15 January 2025
Resolution: New flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 January 2025 Resolved
Life Float- Secured to the painter at one end and the vessel at the other end. If synthetic, be dark in color or resistant to deterioration from UV light. Painter was not secured to the vessel or life float for the new 12 man life float. Secure to vessel's weak link and place stops between the upper and lower life float. 46 CFR 180.137 Code 10 c
Action required: 10 - Deficiency Rectified
Due 14 January 2025
Resolved 14 January 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these on the bridge and one at the access to the engine room. Provide two flash lights. 46 CFR 183.430 Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 16 January 2025
Resolution: Provided
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 January 2025 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station and must be illuminated. Vessels compass light was not operable. Correct to the satisfaction of the attending MI. 46 CFR 184.402 Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 16 January 2025
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2025 Resolved
A vessel must carry either a first aid kit approved under 1999.175 (b)(10) or a kit with equivalent contents and instructions. Vessel must provide 50 tablets of ibuprofen ones in kit were expired. 46 CFR 184.710 code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 15 January 2025
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 December 2023 Resolved
The owner, charter, master or operator shall instruct each crew member upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months. The vessel has been laid up and not in operation, new crew and existing crew shall conduct the drills required by 185.520 & 185.524 prior to sailing with passengers. Drills must also be completed in the presence of attending MI to complete annual inspection within time allotted by def code. 46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2024
Resolved 4 January 2024
Resolution: Drills conducted satisfactory.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 December 2023 Resolved
On board a seagoing vessel no person may assign any person to perform shipboard duties and no person may perform those duties unless the person performing them has received training. Vessel officers are required to have CPR training IAW NVIC 1-91. Complete a CPR course and provide proof to the satisfaction of the attending MI. 46 CFR 15.1105 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2024
Resolved 4 January 2024
Resolution: Captain obtained currenct CPR cert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 December 2023 Resolved
Each life jacket carried on a vessel on oceans, coastwise or Great Lakes route, must have a life jacket light approved in accordance with 161.012 subchapter Q. Vessel currently has 05 life jackets missing lights. Vessel passenger count is reduced to 10 persons during night voyages until new lights are provided to the satisfaction of the attending MI. 46 CFR 180.75 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2024
Resolved 4 January 2024
Resolution: 05 New lights obtained.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 December 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is or is likely to become a serious marine incident as defined in 4.03-2 of subchapter A shall comply with the requirements of 4.06. Vessel does not currently have alcohol testing devices approved for the testing requirements of 46 CFR part 4. Provide to the satisfaction of the attending MI. 46 CFR 185.212
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2024
Resolved 4 January 2024
Resolution: Alco Screen 02 strips purchased.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 December 2023 Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit of equivalent contents and instructions. Vessels first aid kit requires restocking of items that have expiry dates on them. Provide to the satisfaction of the attending MI. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2024
Resolved 4 January 2024
Resolution: First aid kit stocked.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 October 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural exam once every two years. Vessel was due for dry dock on 30 June 2023. Vessel is not permitted to carry passengers or cargo until dry dock is completed. 46 CFR 176.600 (c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Completed satisfactory dry dock and ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2021 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Repair port engine RPM gauge in the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 7 February 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 28 October 2021 Resolved
Each vessel certified under 46 CFR Subchapter T is required to hold a valid stability letter. The changes made to the [name withheld] since issuance of the stability letter have adversely affect the stability letter. These changes include: adding an awning over the aft control station, adding tires along both rails, adding a second life float, line handling gear, and push knees. Vessel is required to complete a simplified stability proof test or deadweight survey.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 7 February 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 October 2020 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Prove crew enrolled in approved drug and alcohol tsting program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2020
Resolved 5 November 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2020 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Provide one 40 B:C fire extinguisher in accordance with COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2020
Resolved 30 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2020 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Prove proper operation of bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2020
Resolved 5 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 October 2020 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Prove proper operation of ammeter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2020
Resolved 21 December 2020
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 October 2020 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, a public address system is not required if a public announcement made from the operating station without amplification can be heard throughout the accommodation spaces of the vessel during normal operating conditions, to the satisfaction of the [name withheld] cannot be heard during normal operation. Prove proper operation of PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2020
Resolved 30 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020 Resolved
Each distribution panel and switchboard must be in as dry of place possible and protected from splashing water. Generator control panel has a rusted front allowing water to contact electrical circuits. 46 CFR 183.30
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2020
Resolution: New control panel installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2020 Resolved
Design of all exhaust system must ensure minimum risk of injury to personnel. Exhaust lagging missing in multiple location before the wet exhaust connection which will exceed 150 degrees F on the MDE's. 46 CFR 182.430/ 46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2020
Resolution: Lagging replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
01 ring buoy required to have a light with a line 3-6ft attached with a corrosion resistant clip. Line on ring buoy was not servicable. Corrected prior to completion of inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
Resolution: Line replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 12 August 2016 Resolved
Vessel Master did not have DAPI pre-employment screening. extended from prior to sail to within 7 days after vessel master provided proof of taking the test.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2016
Resolved 15 August 2016
Resolution: cleared via reciept of negative test results.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 August 2016 Resolved
No DAPI Program or consortim membership in place for drug testing.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 15 August 2016
Resolution: Vessel provided proof of enrollment in a consortium.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 August 2016 Resolved
Provide alchol test strips
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: vessel rep provide reciept for new strips and changed arrangment to prevent exposure to temperatures outside of range.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 12 August 2016 Resolved
Chrats are not updated IAW notice to mariners.
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Vessel rep provided satsifactory charts, chart correction kit and showed satisfactory first correction.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 August 2016 Resolved
Tide Charts are not on vessel.
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: vessel rep provided recipt for tide and current tables.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 July 2015 Resolved
2 of the vessel's PFDs were not serviceable; vessel removed and renewed with 2 new PFDs prior to completion of inspection.
Action required: 705 - Other - as specified
Resolved 15 July 2015
Resolution: Vessel removed and renewed with 2 new PFDs prior to completion of inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 August 2014 Resolved
Inproper wire splice underneath helm.
Due 12 August 2014
Resolved 12 August 2014
Resolution: Corrected on Spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2012 Resolved
Bilge alarm system inoperative throughout vessel. Vessel shall repair to original condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2012
Resolution: Visually inspected bilge alarm system and verified proper operation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 August 2011 Resolved
All of vsls fire extinguishers were one month out of service date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2011
Resolved 3 August 2011
Resolution: Vsl took all fire extinguishers to local servicing facility. Verified service tags on extinguishers.
Lifesaving › Lifebuoys › Serviceable
Issued 3 August 2011 Resolved
Vsls lifebuoy's retro tape was worn and lifeline was severly deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2011
Resolution: Vsl procured new lifebuoy and placed in service.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 August 2011 Resolved
Vsl had out dated alcohol test strips onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 August 2011
Resolution: Vsl procured new test strips locally.
Engineering › Fuel Oil Service System › Piping
Issued 3 August 2011 Resolved
Vsl had a small 8 inch piece of pipe on the suction next to the emergency f/o shut-off valve that was severely rusted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 3 August 2011
Resolution: Vsl replaced piece of pipe.
Electrical › Electrical Distribution System (service) › Switch
Issued 3 August 2011 Resolved
Both port and stbd battery switch were not mounted properly and were hanging by their wires.
Condition: Improper/Lack of Maintenance
Due 10 August 2011
Resolved 3 August 2011
Resolution: Vsl securely bolted switches to the bulkhead.
Electrical › Electric Supply System (service) › Cable
Issued 3 August 2011 Resolved
Battery cable had a 4 inch long split in the insulation of the battery cable exposing bare wire.
Condition: Improper/Lack of Maintenance
Due 10 August 2011
Resolved 3 August 2011
Resolution: Vsl cut back wire and reinstalled fitting.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 3 August 2011 Resolved
Generator battery terminal on the positive side was wasted and loose.
Condition: Improper/Lack of Maintenance
Due 10 August 2011
Resolved 3 August 2011
Resolution: Vsl replaced both battery terminals.
Engineering › Lubricating Oil Service System › Filter
Issued 3 August 2011 Resolved
Vsls generator oil filter looked very old and was severely concaved. Vsl rep stated that they reuse their oil filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 3 August 2011
Resolution: Vsl installed new oil filter.
Stability › Watertight Integrity › General
Issued 3 August 2011 Resolved
Vsl had two holes on the stbd side of the fwd engine room watertight bulkhead. Old wire runs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 12 August 2011
Resolution: Contacted vsl rep via phone. Confirmed with vsl rep that two holes were filled on the fwd stbd side of the engine room.
Fire Fighting › Fire Bucket › Availability
Issued 28 August 2008 Resolved
Provide 3, 2.5 gal firebuckets with lanyard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Resolution: Spoke with owner who said that the buckets were back onboard vsl.
Navigation › Piloting/Steering › Marine Charts
Issued 28 August 2008 Resolved
Provide updated chart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2008
Resolution: Owner faxed copy of receipt for new chart.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 August 2008 Resolved
Provide 01 lifejacket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2008
Resolution: Owner faxed a copy of receipt.
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2008 Resolved
Remove drop light that is improperly wired.
Action required: 705 - Other - as specified
Due 29 September 2008
Resolved 9 April 2009
Resolution: Vsl rep confirmed via phone that drop light had been removed.
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2008 Resolved
Remove deadens wires and tape nuts.
Action required: 705 - Other - as specified
Due 29 September 2008
Resolved 9 April 2009
Resolution: Vsl rep confirmed via phone that electrical wire issues had been addressed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 August 2008 Resolved
Completely wrap engine exhaust with lagging.
Action required: 705 - Other - as specified
Due 29 September 2008
Resolved 9 April 2009
Resolution: Vsl rep confirmed via phone that lagging had been installed.
Engineering › Fuel Oil Service System › Valve
Issued 28 August 2008 Resolved
Tighten nuts on reach rod.
Action required: 705 - Other - as specified
Due 29 September 2008
Resolved 9 April 2009
Resolution: Vsl rep confirmed via phone that reach rod had been tightened.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 28 August 2008 Resolved
Provide plumbers plugs for vents.
Action required: 705 - Other - as specified
Due 29 September 2008
Resolved 9 April 2009
Resolution: Vsl rep confirmed via phone that plugs had been installed.
Construction/Loadline › Hull › Hull Plating
Issued 11 May 2007 Resolved
Three old damaged areas noted on hull near collision bulkhead and one improper insert just below deck. No breech of hull noted, damage old. Gave owner additional time to effect repairs.
Condition: Damaged By Earlier Event
Due 11 October 2007
Resolved 5 June 2009
Resolution: No damage found.
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2004 Resolved
Vessel sister [name withheld]. Awaiting MSO approval.
Condition: Unknown
Due 24 September 2004
Resolved 17 February 2005
Resolution: Drafted stability letter for [name withheld] signature based on sistership status verified by attending inspector.
Stability › Incline Test › General
Issued 7 May 2003 Resolved
Outstanding stability test required by previous inspector missed on Critical Profile and not completed; will be conducted at time of next inspection.
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 17 February 2005
Resolution: Stability test not conducted as owner provided documentation of sistership status [name withheld]. Attending inspector verified that vessels are sisters.
Documentation › Certificates/Documents
Issued 6 May 2002 Resolved
Provide proof of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Navigation › Piloting/Steering
Issued 6 May 2002 Resolved
Provide copy of US Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Navigation › Piloting/Steering
Issued 6 May 2002 Resolved
Provide coppy of Tide/Tidal CurrentTables LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Communications › Alarms/Indicators
Issued 6 May 2002 Resolved
Label bilge alarm panel in pilothouse. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Lifesaving › Hand Flares
Issued 6 May 2002 Resolved
Provide one red flare. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Lifesaving › Rigid Liferafts
Issued 6 May 2002 Resolved
Replace reflective tape on life float. LEGACY COMPONENT DESC: Reflective Tape
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 22 May 2002
Deck/Cargo › Vapor Control Systems
Issued 6 May 2002 Resolved
Provide flame screen on fuel tank vent. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2002
Resolved 22 May 2002
Fire Fighting › Remote Fuel Shutoff
Issued 6 May 2002 Resolved
Replace broken handle on fuel tank shutoff valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2002
Resolved 22 May 2002
Engineering › Fuel Oil Service System
Issued 6 May 2002 Resolved
Replace worn hose on outlet side of fuel tank. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2002
Resolved 22 May 2002
Fire Fighting › Miscellaneous Items
Issued 6 May 2002 Resolved
Provide three, 2.5 gallon, fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2002
Resolved 22 May 2002
Stability › Incline Test › General
Issued 6 May 2002 Resolved
Upon completion of installation of new main engines conduct a simplified stability test with cognizant OCMI present. LEGACY COMPONENT DESC: Simplified Stability Test
Action required: 705 - Other - as specified
Due 6 August 2002
Resolved 17 February 2005
Resolution: Installation did not change stability. Test not required as vessel is sister [name withheld].
Construction/Loadline
Issued 6 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN RUDDER ROOM AND FWD BILGE COMPARTMENT (AUDIBLE AND VISUAL IN PILOT HOUSE) TO THE SATISFACTION OF ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Documentation
Issued 30 April 1996 Resolved
PROVIDE MSO MORGAN CITY DOCUMENTATION THAT THE MARINE EMPLOYER HAS ESTABLISHED AND IMPLEMENTED A CHEMICAL TESTING PROGRAM AS REQUIRED BY 46CFRPART 16.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Accommodation/Occupational Safety
Issued 25 September 1991 Resolved
MAKE REPAIRS TO INSTALLED ELECT-SAN TOILET. VESSEL RUN LIMITED TO 30 MINUTES FROM DOCK UNTIL REPAIRED. TOILET IS NOT TO BE USED UNTIL REPAIRED.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Engineering
Issued 5 June 1989 Resolved
PROVIDE A 30 X 30 MESH FLAME SCREEN ON THE DIESEL FUEL TANK DECK VENT IN ACCORDANCE WITH 46 CFR 182.20-35(D).
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989

Casualty record · 1

26 January 2024Routine · role: Transiting Vicinity of Primary Subject · activity 7861443
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.