Records from 1993 to 2025. Most recent: inspection, 23 September 2025.
Documentation record
Registered dimensions (L × B × D)90.7 ft × 28.0 ft × 12.4 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)90.7 ft × 28.0 ft × 12.4 ft
ITC tonnagegross 222 / net 66
BuilderTHE SERVICE MACHINE GROUP · AMELIA, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portYONGES ISLAND, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
222 - Convention (Subpart B), Gross Ton
66 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
23 September 2025
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8244666
18 July 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8189117
11 July 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7956256
30 May 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7971723
26 January 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7861443
10 August 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7765074
3 August 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7759658
17 May 2023
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7716665
30 August 2022
MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7547168
21 June 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7482598
13 March 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7410909
17 May 2021
Initial Certification · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7199383
29 January 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6903344
25 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6842128
24 October 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6846993
4 August 2015
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5206357
15 May 2015
Administration · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5131005
7 May 2015
Administration
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5119863
31 July 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4966899
18 January 2011
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3928287
11 January 2011
MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3926808
20 August 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3829305
26 October 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808824
22 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2398906
7 July 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2125052
18 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2148120
19 January 2000
Type not recorded
No type recorded · USCGC MONHEGAN (WPB 1305) · USCG Southeast District (CGD-SE) · Activity 1514996
11 January 2000
Type not recorded
No type recorded · USCGC DAUNTLESS (WMEC 624) · Activity 1497139
4 February 1998
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1094133
4 February 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1108727
29 September 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 489940
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 May 2023
Resolved
Each survival craft must be stowed in a secure and sheltered position and protected from damage by fire and explosion, as far as practicable; and (7) So as not to require lifting from its stowed position in order to launch. The rafts were stowed atop the pilothouse, and needed to clear 3 decks to get to the water.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 16 June 2023
Resolution: New launching appliances were fabricated, and a video showing the test launch was provided
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 August 2022
Resolved
Each towing vessel must be fitted with a general alarm that: Has installed in the E/R and any other area where background noise makes a general alarm hard to hear, a flashing red light. The flashing light was inop at the time of the inspection.
Action required: 10 - Deficiency Rectified
Due 30 August 2022
Resolved 30 August 2022
Resolution: The flashing light was repaired and showed proper operation.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 August 2022
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Electronic position-fixing device, satisfactory for the area in which the vessel engages in towing. The GPS antenna was in the process of being replaced at the time of the inspection. The antenna was replaced and all equipment is operating correctly.
Action required: 10 - Deficiency Rectified
Due 30 August 2022
Resolved 30 August 2022
Resolution: The GPS antenna was replaced and all equipment was operating correctly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2021
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Vessel's semi-portable is not attached to bulkhead nor is hose long enough to reach the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2021
Resolution: Vessel mounted semi portable in a location that hose reaches E/R
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2021
Resolved
Each towing vessel with a fixed fire pump must be able to deliver water simultaneously from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 50 pounds per square inch and a flow rate of 80 gpm. Vessel's fire pump had a pitot-tube pressure of 30 psi.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2021
Resolution: Vessel is operating with a portable fire pump that meets the requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 June 2021
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Vessel did not know what set points different alarms were required to trip at. Vessel to submit an engineering report on the testing of all required tests listed in Table 143.245(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2021
Resolution: Vessel provided report of szaatisfactory testing of the required alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 June 2021
Resolved
Each vessel operating north of lat 32 N or south of lat 32 S must carry the number of immersion suits for each person onboard. Vessel missing one suit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: missing imersion suit was placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2021
Resolved
Towing vessel more than 65 feet in length must use navigation lights that meet UL 1104. Vessel's navigational light panel does not meet 1104.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2021
Resolution: Received documentation that lights do comply with UL1104
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2021
Resolved
Towing vessels must be equipped with a search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Vessel's search lights were seized up.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: Vessel serviced lights and are now functional.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 16 June 2021
Resolved
Each towing vessel of 79 feet or more in length operating on an oceans route with no installed fixed fire extinguishing system must have two firefighters outfits that meet NFPA 1971. Vessel is missing various items for fire suits.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: Required equipment for firemens outfit was placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 16 June 2021
Resolved
A record of the type, size and service of each towline used to make the towing vessel fast to her tow must be available to the USCG for review. The minimum information is required in the record: dates when examinations were performed, identification of each item of towing gear examined and the names of the persons conducting the examination. Vessel's towing hawsers could not be associated with proper documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: Towing hawsers were identified and asscoiated with certifcations
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 June 2021
Resolved
The master must ensure all hatches, doors and other openings designed to be weather tight function properly. Vessel's doors at the wheelhouse were leaking water.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: Hose tested doors with satisfactory results.
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 16 June 2021
Resolved
Each towing vessel operating in oceans service must have a line throwing appliance approved under approval 160.040. Vessel only has one rocket and is missing the required four rocket projectiles, each complete with bridle and leader of fire-resistant materials, with two of the projectiles made of a buoyant type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: linethrowing devices with bouyant projectiles were placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021
Resolved
Electrical connections must be installed to prevent them from coming loose through vibration or accidental contact. Vessel's back up UPS is not secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: UPS secured in the in space below pilot house.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2019
Resolved
STBD MDE leaking head gsk (blown) and bad turbo
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2019
Resolution: CAPT provided tech report and testing statement. New turbo, head gsk, gaskets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2019
Resolved
Over due on MOB and Fire drills.
Last MOB 12 Aug 2019
Last Fire 27 Aug 2019
Also no drill conducted after crew change.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2019
Resolution: CAPT provided proof of drills via e-mail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2019
Resolved
Port & STBD MDE, STBD SSDG were fitted with plastic fuel bowls and drains with no metalic flame deflector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2019
Resolution: CAPT provided photos and report of new fuel filter throughout with proper flame deflector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 October 2019
Resolved
Hydrostatic release expired July 2019.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2019
Resolution: CAPT provided new hydrostatic release.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 25 October 2019
Resolved
MIs found a burn barrel on the back deck 1/3 full of ashes. Their waste management plan states the vessel will retain all trash.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 October 2019
Resolution: Rev=moved burn barrel from vessel. CAPT sent statement and photos.
Engineering
Issued 4 February 1998
Resolved
PROVIDE POLLUTION PLACARD NEAR PUMPS IN E/R.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998
Fire Fighting
Issued 4 February 1998
Resolved
PROVIDE PROPER PLACARDS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998