HERCULES

HERCULES is a 1978 offshore supply vessel. The Coast Guard has recorded 70 inspections since 1982, most recently in November 2025, along with 63 deficiencies, 1 operational control and 3 casualty investigations between 2006 and 2020.

Records from 1982 to 2025. Most recent: inspection, 12 November 2025.

Built
1978
Last inspected
12 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5248
Flag
UNITED STATES
338744000
Maury page id
psix-49704

Inspections, by type

…with no type recorded14
Years with a record 40 calendar years (1982–2025)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)106.9 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCULLY BROS BOAT BUILDING · STEPHENSVILLE, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 August 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG5248MMSI 338744000 · active · compulsorily equipped · granted 30 August 2022, expires 7 September 2032
WDC5161MMSI 367036840 · expired · voluntarily equipped · granted 26 April 2005, cancelled 27 June 2015
WAI2789MMSI not assigned · expired · compulsorily equipped · granted 12 January 1995, cancelled 12 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALBATROSS TRADER Tank Ship · MISLE 1369587 · 20 November 2020 · activity 7152368BRENDA P Research Vessel · MISLE 762458 · 22 February 2006 · activity 2608961

Inspection history · 70

12 November 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8267501
26 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8085091
4 October 2024 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8010412
30 August 2023 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7774243
31 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7701961
1 December 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7602846
7 October 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7573673
10 December 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7366013
21 September 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7317212
20 November 2020 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099366
20 November 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7152368
5 November 2020 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7090286
6 November 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6850431
28 August 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6797431
11 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6640542
31 July 2018 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6496387
27 October 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6296350
12 October 2016 Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6021193
6 May 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5870564
9 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5739771
9 October 2014 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5002451
11 January 2012 Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4223230
6 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3922200
11 January 2010 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3661884
18 September 2008 COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3317096
16 October 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3086390
16 October 2007 Administrative Inspection · Drydock Exam · Hull Examination · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3158279
21 August 2006 COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2754696
17 August 2006 Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2751414
22 February 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2608961
17 November 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2535775
26 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522374
26 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522383
8 November 2004 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2237260
14 November 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1948966
9 May 2003 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1791944
21 August 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1370392
22 January 2001 Inclining Experiment · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1420456
22 July 2000 Inclining Experiment
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 819905
25 August 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 30301
16 June 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436221
16 September 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 799194
5 May 1998 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468856
27 March 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 786738
13 March 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788141
27 January 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 781803
8 August 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 782404
8 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116346
12 June 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1438598
2 May 1996 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1355771
17 August 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1421007
16 August 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1449714
25 August 1993 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1137374
12 August 1993 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1155461
12 August 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1268863
9 October 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1252813
4 October 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 939517
14 August 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1309547
4 June 1991 Excursion Permit
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1008515
8 April 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 907629
15 August 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922684
15 November 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 925267
16 August 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1351041
23 September 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316677
23 July 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985056
19 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983000
22 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973306
2 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278734
20 January 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970726
8 June 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1277270

Deficiency record · 63

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 December 2022 Resolved
As appropriate for the intended voyage, all vessels except barges, vessels operating exclusively on rivers, and motorboats other than those certificated for ocean or coastwise route, must carry adequate and up-to-date charts / notice to mariners. MIs identified numerous nautical charts (1116A / 1117A / 11324) that were missing applicable chart corrections.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2022
Resolved 6 December 2022
Resolution: Received photo of chart updates.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 December 2022 Resolved
Bells shall be made of corrosion-resistant material and designed to give clear tone. The diameter of the mouth of the bell shall be not less than 300 mm for vessels of 20 meters or more in length. Vessel does not have the required bell installed or on board.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 December 2022
Resolved 2 December 2022
Resolution: Vessel installed bell to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 December 2022 Resolved
Two 7 kg (15-pound) capacity hand portable dry chemical or two portable 10 L (2.6 gallons) foam-type extinguishers must be accessible to any packaged Class 3 (flammable) or combustible liquid and suitable for use with the lading. Extinguishers required for the carriage of portable tanks containing flammable or combustible materials are not on board.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2022
Resolved 6 December 2022
Resolution: Vessel owner will provide portable fire extinguishers when needed to carry hazardous material MPT.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 December 2022 Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed at least at least once in every twelve months the tests and inspections of all hand portable fire extinguishers on board. Annual hand portable fire extinguisher servicing records were older than twelve months.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 2 December 2022
Resolution: Third-party inspection report provided. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2021 Resolved
46 CFR 111.12-1(b) Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more that 15 percent. The overspeed device for the port generator is not operational. Make repairs to the satisfaction of the Coast Guard prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 December 2021
Resolution: Vessel made repairs and conducted satisfactory test of port generator overspeed device in presence of Coast Guard MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 November 2020 Resolved
46 CFR 97.05-5 As appropriate for the intended voyage, all vessels except barges, vessels operating exclusively on rivers, and motorboats other than those certificated for ocean or coastwise route, must carry adequate and up-to-date - (c) Coast Pilots Coast pilot on board is from 2019, and does not have any updates, causing it to be out of date.
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 9 November 2020
Resolution: Replaced the 2019 Coast Pilot with 2020 Coast Pilot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2020 Resolved
46 CFR 91.25-15(a)(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see 46 CFR 91.25-7). Provide annual servicing report for portable firefighting extinguishers.
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 9 November 2020
Resolution: Provided annual fire servicing report from A-1 Fire Equipment Company, inspection was completed on 22OCT20.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2020 Resolved
46 CFR 91.25-15(a)(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see 46 CFR 91.25-7). The nozzle on the CO2 fire extinguisher was crushed inhibiting the dispersion of the agent.
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 9 November 2020
Resolution: Nozzle on the fire extinguisher was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2020 Resolved
46 CFR 92.05-1 The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Remove excessive lint build-up from dryer lint trap & maintain a lint free area.
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 9 November 2020
Resolution: Dryer exhaust area cleaned of all lint.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 November 2020 Resolved
46 CFR 199.640(j) Vessel must carry an approve life float. Life float is in deteriorating shape, lines are deteriorated and parting, paddles are not secured, and float-light is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 November 2020
Resolved 9 November 2020
Resolution: Replaced deteriorating life float, provided pictures of new life float stenciled with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2020 Resolved
46 CFR 161.010-2 Each floating electric waterlight shall meet the requirements of ANSI/UL 1196. The waterlight attached to the life-ring is inoperable.
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 5 November 2020
Resolution: Replaced battery with approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 November 2020 Resolved
46 CFR 199.190(e) Each lifesaving appliance, including lifeboat equipment must be inspected monthly using the checklist required under paragraph (b)(1)(j) of this section to make sure the appliance and the equipment are complete and in good working order. A report of the inspection, including a statement as to the condition of the equipment, must be recorded in the vessel's official logbook. Monthly inspections of lifesaving equipment would have discovered the deteriorated life float, and expired EPIRB battery. Develop monthly life saving inspection checklist and record inspections monthly in the vessel's logbook.
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 9 November 2020
Resolution: Monthly equipment inspections will be included in vessel logbook. Owner developed format and provided training to the master and crew.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2020 Resolved
46 CFR 199.510(a) Each vessel must carry a category I 406 MHz satellite EPIRB meeting the requirements of 47 CFR part 80. The installed EPIRB's battery has expired.
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 5 November 2020
Resolution: Replaced with a non-expired EPIRB.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 5 November 2020 Resolved
46 CFR 111.75-15(c)(2) Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Two emergency lights in the engine room are inoperable, preventing for sufficient lighting of egress.
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 5 November 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2019 Resolved
If damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be taken out of service to effect permanent repairs. A section of the hull plating at the fwd end of the engine room was found to have significant wastage. The section shall be cropped and renewed as per the requirements from the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 10 September 2019
Resolution: MIs witnessed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 August 2019 Resolved
If damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be taken out of service to effect permanent repairs. The following internal structural members shall be repaired to the satisfaction of the attending Marine Inspector. Lower Forepeak: 1. Crop and renew both port and starboard overhead longitudinals in the lower forepeak. 2. Crop and renew wasted section of the transverse frame 2nd frame forward of the collision bulkhead near upper portion of the FP. #2S Cargo Potable Tank: Crop and renew both the 2nd and and 3rd section of the bottom side long.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 10 September 2019
Resolution: MIs witnessed satisfactory repairs.
Fire Fighting › Fire Main › Condition
Issued 27 October 2017 Resolved
Fire main suction piping found wasted and not serviceable. Repair to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2017
Resolution: Removed wasted pipe and installed renewed piping, all sat.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 27 October 2017 Resolved
Correct open grounds in kitchen and crew quarters outlets to prevent shock hazard. Correct to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 7 November 2019
Resolution: Item resolved to satisfaction of attending MI.
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2017 Resolved
Repair ships service generators to normal function. Demonstrate over speed trips to the satisfaction of the attending MI>
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 November 2019
Resolution: Overspeed trips were conducted to the satisfaction of attending MI.
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 October 2017 Resolved
Install insect screens on potable water tank vents.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 30 November 2017
Resolution: New insect screens installed, all sat.
Communications › Radio Communications › EPIRB
Issued 27 October 2017 Resolved
Provide NOAA registration for EPIRB on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 30 November 2017
Resolution: NOAA registration for EBIRB onboard, all sat.
Engineering › Bilge Water Management System › Pump
Issued 12 October 2016 Resolved
O/O could not demonstrate proper operation of the vessel's bilge water system. Prove proper operation of the Bilge dewatering system to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 14 October 2016
Resolution: MI witnessed satisfactory operation of the vessel's bilge system.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 12 October 2016 Resolved
Vessel operator could not demonstrate proper operation of the MDE's safety shutoff devices. Test to the satisfaction of the attending marine inspector the safety shutdown devices.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 7 November 2019
Resolution: Shutdowns were conducted to the satisfaction of attending MI.
Stability › Weathertight Integrity › General
Issued 11 January 2010 Resolved
Repair/Replace rear windows on pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Resolution: 15Jan10: Witnessed that rear window in pilot house has been replaced. Inspection was satisfactory and deficiency was cleared.
Engineering › Fuel Oil Service System › Valve
Issued 11 January 2010 Resolved
Repair/Replace fuel oil system shutdown spring.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2010
Resolution: Repaired spring on the spot during inspection for fuel oil shut down.
Construction/Loadline › Penetrations › Gasket
Issued 11 January 2010 Resolved
Repair gasket on escape hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 11 January 2010
Resolution: Repaired gasket on the spot during inspection.
Electrical › Electric Generation Source (service) › Generator
Issued 21 August 2006 Resolved
Clean oil and debris from both generators
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2006
Resolution: Both generator winding were cleaned and test run satisfactory
Fire Fighting › Fire Main › Pressure
Issued 21 August 2006 Resolved
Prove proper operation of the vessel's fire monitor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 23 January 2007
Resolution: RCVD attestation from vessel rep to clear def.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 21 August 2006 Resolved
Provide required line throwing appliance IAW 33CFR Subchapter "N"
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 January 2007
Resolution: Line throwing gun provided.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 21 August 2006 Resolved
Provide required searchlight IAW 33 CFR subshapter N
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 January 2007
Resolution: Search light provided.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 21 August 2006 Resolved
Prove proper operation of generator overspeed trips.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2006
Engineering › Fuel Oil Service System › Valve
Issued 21 August 2006 Resolved
Repair fuel oil leaks on both generators and the emergency fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2005 Resolved
Remove extension cord from under console in bridge.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 29 December 2005
Resolution: Cord removed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 17 November 2005 Resolved
Replaced cracked center windshield on wheel house and crackedlarge window in stern steering station room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 29 December 2005
Resolution: Windshields replaced.
Engineering › Fuel Oil Service System › Pump
Issued 17 November 2005 Resolved
Locate and repair leak on fuel transfer pump on starboard side of engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 29 December 2005
Resolution: Leak located and corrected.
Engineering › Bilge Water Management System › Piping
Issued 17 November 2005 Resolved
Remove flexible hose coupling from all bilge piping in engine room and join with steel coupling or weld.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 29 December 2005
Resolution: Pipe welded.
Construction/Loadline
Issued 22 January 2001 Resolved
Repair and demonstrate proper operation of forepeak collision bulkhead bilge line suction valve and reach rod. To be completed at next inspection,prior to vessel being put back in service._x001C_
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Deck/Cargo
Issued 16 June 1999 Resolved
RENEW ANCHOR CABLE
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Accommodation/Occupational Safety
Issued 16 June 1999 Resolved
FREE UP ENGINE ROOM ESCAPE HATCH,
Condition: Unknown
Due 7 July 1999
Resolved 21 June 1999
Lifesaving
Issued 16 June 1999 Resolved
REPLACE 12 MAN LIFE FLOAT
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Electrical
Issued 16 June 1999 Resolved
REPLACE OR REPAIR LIGHT COVER IN ENGINE ROOM
Condition: Unknown
Due 16 July 1999
Resolved 21 June 1999
Deck/Cargo
Issued 16 June 1999 Resolved
REPLACE SCREEN STARB/PORT FUEL VENT.
Condition: Unknown
Due 16 July 1999
Resolved 21 June 1999
Lifesaving
Issued 5 May 1998 Resolved
REPLENISH FIRST AID KIT IAW 46 CFR 160.041.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Engineering
Issued 5 May 1998 Resolved
REPAIR LEAKING FUEL PIPE IN WAY OF THE ENGINEROOM FWD BULKHEAD PORT SIDE.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 5 May 1998 Resolved
REMOVE HOSE AND CLAMPS FROM BILGE SUCTION LINE RUNNING UNDER THE STBD GENERATOR MOTOR IN ENGINEROOM AND MAKE PERMENANT REPAIRS (MISALIGNED).
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 5 May 1998 Resolved
REPAIR LOWER LIP TO 01 DECK AFT WATER TIGHT DOOR, REPLACE GASKET AND PROVE PROPER OPERATION.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Electrical
Issued 5 May 1998 Resolved
SECURE SPOTLIGHT AND AIR CONDITIONING (EXTERIOR) CABLES.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 5 May 1998 Resolved
ENSURE MAIN DECK VENT COVERS SECURE PROPERLY WITH QUICK CLOSING DEVICE (WING NUT).
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 13 March 1998 Resolved
REPAIR STERN BALLAST TANK PORT & STARBOARD IN WAY OF SIDESHELL/MAIN DECK SEAM AT THE CORNERS. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI NOT LATER THAN 28 MARCH 1998.
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Construction/Loadline
Issued 8 July 1997 Resolved
REPAIR DOGS ON WATERTIGHT DOOR TO CARGO DECK AND CONDUCT CAULK TEST.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 8 July 1997 Resolved
REPLACE PLASTIC WIRE TIES IN OVERHEADS WITH METAL TIES.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997 Resolved
REPLACE HATCH COVER ON ENGINEROOM ESCAPE HATCH.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
REPAIR CRACKED RAILINGS ON STBD FORECASTLE.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997 Resolved
COMPLETE WELDS IN ENGINEROOM OVERHEAD ABOVE BOTH MDE.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 14 August 1991 Resolved
INSTALL MARINE CLAMPS ON ALL WIRE SPLICES UNDER 50 VOLTS IN PILOT HOUSE.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991 Resolved
REPAIR W/T HATCH LEADING TO ENGINE ROOM FROM MAIN DECK, (NEEDS A LOCK STOP)
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Electrical
Issued 14 August 1991 Resolved
INSTALL COVERS ON TWO JUNCTION BOX'S UNDER CONTROL CONSOLE IN PILOT HOUSE.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991 Resolved
PROPERLY INSTALL W/T DOOR FROM MAIN DECK TO MAIN CABIN. W/T DOOR INSTALLATION IS SOFT PATCHED.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Electrical
Issued 15 August 1990 Resolved
REPAIR OVERSPEED PORT GENERATOR.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Engineering
Issued 15 August 1990 Resolved
INSTALL AND TEST RELIEF ON #1 AIR RECEIVER.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Accommodation/Occupational Safety
Issued 15 November 1989 Resolved
PARTITION OFF BERTHING AREA IN LOWER ACCOMADATION AREA. ARRANGE NO MORE THAN (4) BUNKS TO A BERTHING COMPARTMENT.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Navigation
Issued 20 January 1984 Resolved
REPAIR INOPERATIVE RADAR.
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Engineering
Issued 20 January 1984 Resolved
RENEW STARBOARD MAIN ENGINE EXHAUST LAGGING.
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984

Casualty record · 3

22 February 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 2608961
16 October 2007Routine · role: Involved in a Marine Casualty · activity 3086390
20 November 2020Routine · role: Involved in a Marine Casualty · activity 7152368
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.