GP 35

GP 35 is a 1978 industrial vessel. The Coast Guard has recorded 41 inspections since 1981, most recently in June 2012, along with 62 deficiencies and 1 casualty investigation in 2012.

Records from 1981 to 2012. Most recent: inspection, 11 June 2012.

Built
1978
Last inspected
11 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

----------
Flag
UNITED STATES
366966250 (licence lapsed)
Maury page id
psix-49717

Inspections, by type

…with no type recorded9
Years with a record 24 calendar years (1981–2012)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it885 - Regulatory (Subpart C or D), Net Ton
885 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCP5526MMSI 366966250 · expired · compulsorily equipped · granted 3 January 1995, cancelled 5 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MANNY J Towing Vessel · MISLE 92993 · 10 June 2012 · activity 4351224CAJUN Towing Vessel · MISLE 155567 · 26 March 1996 · activity 54338WAHOO Offshore Supply Vessel · MISLE 360030 · 26 March 1996 · activity 54338

Inspection history · 41

11 June 2012 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4344893
10 June 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4351224
13 December 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4206465
26 January 2011 Periodic Inspection · Drydock Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3933863
3 April 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3445443
11 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3264541
13 November 2007 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3097837
20 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2782850
9 June 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2674991
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972269
29 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115623
10 February 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793196
2 April 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122572
23 February 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445315
31 December 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783415
14 April 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414778
30 January 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390425
6 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765100
5 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 199190
9 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165999
26 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54338
29 January 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455322
7 February 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460765
8 February 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423868
2 August 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847759
3 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471802
6 January 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1143388
26 February 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953701
17 June 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037136
20 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917040
4 February 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305258
5 December 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228382
28 February 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220833
8 February 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350798
22 March 1988 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1295046
12 February 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008164
29 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987065
12 December 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303411
19 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982818
28 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966880
3 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275764

Deficiency record · 62

Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 13 December 2011 Resolved
Fuel Hose Certificate expired. Vessel shall provide current certificate to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 15 December 2011
Resolution: Vessel representative provided copy of new fuel hose certificate.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 13 December 2011 Resolved
Electrical Room, type B-V fire extinguisher required to be secured for sea.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 15 December 2011
Resolution: Visually verified type B-V fire extinguisher secured for sea.
Engineering › Fuel Oil Service System › Piping
Issued 13 December 2011 Resolved
Port Generator fuel line leaking. Vessel shall repair/replace to satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2011
Resolution: Visually verified new fuel line elbow installed. No leaks.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 December 2011 Resolved
Oily water seperator no longer in service. Vessel shall repair or remove oily water seperator to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 23 December 2011
Resolution: I-Barge does not have a bilge, and does not require oily water seperator installed IAW 33 CFR 155.360(d). Visually verified old oily water seperator was removed, properly blanked off, with no possibility of discharge overboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 January 2011 Resolved
Vsl must provide satisfactory testing of OWS
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 18 February 2011
Resolution: Corrected to the satisfaction of the attending CG inspector.
Lifesaving › Lifebuoys › Stowage
Issued 26 January 2011 Resolved
Permenantly mount brackets for lifebuoy
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2011 Resolved
Middle navigational lights need to be fixed.
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 26 January 2011 Resolved
Properly secure fire protection above port generator
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Engineering › Generator (propulsion-electric) › Heating Element Circuitry
Issued 26 January 2011 Resolved
Replace lagging on starboard exhaust
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 January 2011 Resolved
Make wire penetration in starboard generator room watertight bulkhead watertight
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 18 February 2011
Resolution: Corrected to the satisfaction of the attending CG marine inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 January 2011 Resolved
Properly coil lifebuoy line
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 26 January 2011 Resolved
Install CO2 for paint locker or remove locker
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the Coast Guard Marine Inspector.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 26 January 2011 Resolved
Install liferafts to meet 46CFR199.10(h).
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 10 March 2011
Resolution: Vessel has installed liferafts to meet 46CFR199.10(h).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2009 Resolved
Provided operational smoke detectors to include detectors missing in berthing.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Engineering › Fuel Oil Service System › Hose
Issued 3 April 2009 Resolved
Provided annual hydro-static test on fuel hoses.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 April 2009 Resolved
Replace fuel hose nozzels with operational automatic back pressure nozzels.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 3 April 2009 Resolved
Demonstrate proper means of escape from engine room.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Fire Fighting › Grease Extraction Hood › General
Issued 3 April 2009 Resolved
Provide approval information on installed dry chem extinguishing system in galley (hood).
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2009 Resolved
Provided eye wash solution for eye wash station.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 7 April 2009
Documentation › Certificates/Documents › Stability Letter
Issued 13 November 2007 Resolved
Vessel needs to provide the Stability Letter.
Action required: 705 - Other - as specified
Resolved 6 March 2008
Resolution: Scanned in stability data as indicated from 20JUN1979.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 November 2007 Resolved
All open spaces need to be blanked off in electrical panel in the galley.
Action required: 705 - Other - as specified
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 November 2007 Resolved
The deep fat fryer and television need to be secured to the vessel.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Fire Fighting › Grease Extraction Hood › General
Issued 13 November 2007 Resolved
Service range fire supression system.
Action required: 705 - Other - as specified
Resolved 25 February 2008
Resolution: Vessel owner opted to remove the existing system.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 November 2007 Resolved
Ensure air conditioning venting is properly cleaned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 13 November 2007 Resolved
Ensure all food stores and refridgerator is sanitary.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2007 Resolved
Install covers on all light fixtures throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2007 Resolved
Ensure all emergency lighting is operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 13 November 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2007 Resolved
Ensure all smoke alarms are operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Nozzles › Condition
Issued 13 November 2007 Resolved
Install safety chains on all fire nozzles.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2007 Resolved
Ensure all smoke alarms are operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 November 2007 Resolved
Ensure all staterooms have bunk lights and locker per person.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 November 2007 Resolved
post lifejacket donning placard in each stateroom.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 13 November 2007 Resolved
Ensure all pluming in bathrooms is operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 November 2007 Resolved
Store all flammables in paint locker.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2007 Resolved
Install guards over all moving machinery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Engineering › Steam System (main) › Lagging/Insulation
Issued 13 November 2007 Resolved
Install lagging over all piping over 150 °F.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 November 2007 Resolved
Label all emergency escapes.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2007 Resolved
Install battery covers in machinery space.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 13 November 2007 Resolved
adjust handles on quick acting watertight door.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2007 Resolved
Ensure stanchions meet 46 CFR subchapter I requirements.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 12 March 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 13 November 2007 Resolved
Install portable CO2 extinguisher on paint locker.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Resolution: The paint locker was removed from the vessel.
Engineering › Pressure Vessel › Weld
Issued 13 November 2007 Resolved
Makes pressure vessel available for inspection.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 November 2007 Resolved
Cap off open piping on day tank for hydraulic system.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 November 2007 Resolved
Provide fuel transfer procedures.
Due 31 March 2008
Resolved 13 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 November 2007 Resolved
Service the remote fuel shut off valve (starboard side - aft).
Due 31 March 2008
Resolved 12 March 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 November 2007 Resolved
Provide fire and safety plans.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Engineering › Lubricating Oil Service System › Tube
Issued 13 November 2007 Resolved
Install chaffing material as indicated on the prime mover.
Due 31 March 2008
Resolved 12 March 2008
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 13 November 2007 Resolved
The hydrostatic release units were not marked with the expiration date.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 November 2007 Resolved
The COD was not renewed.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 13 November 2007 Resolved
Provide COFR documentation.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Electrical
Issued 23 February 1998 Resolved
REPAIR GROUND FAULT ON #2 S/S GENERATOR.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 30 January 1997 Resolved
REPAIR OR REPLACE THE OILY WATER SEPARATOR. DEMONSTRATE PROPER OPERATION FOR ISSUANCE OF THE IOPP CERTIFICATE.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Electrical
Issued 30 January 1997 Resolved
FIND AND REPAIR THE GROUND FAULT SHOWN ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Electrical
Issued 30 January 1997 Resolved
INSTALL A SHORE POWER INDICATOR LIGHT AS REQUIRED BY 46CFR111.30-25(f)(2)_x001C_ AND (g)(2).
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Accommodation/Occupational Safety
Issued 30 January 1997 Resolved
REMOVE THE ABONDONED AIR CONDITIONING UNIT FROM THE ENGINE ROOM.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Construction/Loadline
Issued 30 January 1997 Resolved
MAKE PERMANENT REPAIRS TO THE HOLED #5 PORT BALLAST TANK AND ADJACENT BULKHEAD.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Documentation
Issued 29 January 1996 Resolved
PROVIDE ON BOARD A USCG APPROVED SHIPBOARD OIL POLLUTION EMERGENCY RESPONSEPLAN (SOPEP).
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 8 February 1994 Resolved
INSTALL ALARM, MONITORING EQUIPMENT AND SYSTEM DISCHARGE SHUTDOWN DEVICE ONOILY WATER SEPERATOR SUITABLE FOR SYSTEM INSTALLED. SYSTEM IS NOT TO BE OPERATED UNTIL INSPECTED BY MARINE INSPECTOR.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Unknown
Issued 19 March 1985 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ON DECK FUEL TRANSFER SYSTEM.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR OILY WATER SEPARATOR.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985 Resolved
PROVIDE AND INSTALL COAST GUARD APPROVED OILY WATER SEPARATOR IN ACCORDANCEWITH 33 CFR 155.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL G/P 35 DN594130
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985

Casualty record · 1

10 June 2012Routine · role: Involved in a Marine Casualty · activity 4351224
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.