Records from 1981 to 2012. Most recent: inspection, 11 June 2012.
Inspection history · 41
11 June 2012
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4344893
10 June 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4351224
13 December 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4206465
26 January 2011
Periodic Inspection · Drydock Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3933863
3 April 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3445443
11 July 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3264541
13 November 2007
Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3097837
20 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2782850
9 June 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2674991
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972269
29 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115623
10 February 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793196
2 April 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122572
23 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445315
31 December 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783415
14 April 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414778
30 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390425
6 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765100
5 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 199190
9 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165999
26 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54338
29 January 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455322
7 February 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460765
8 February 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423868
2 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847759
3 February 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471802
6 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1143388
26 February 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953701
17 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037136
20 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917040
4 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305258
5 December 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228382
28 February 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220833
8 February 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350798
22 March 1988
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1295046
12 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008164
29 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987065
12 December 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303411
19 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982818
28 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966880
3 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275764
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 13 December 2011
Resolved
Fuel Hose Certificate expired. Vessel shall provide current certificate to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 15 December 2011
Resolution: Vessel representative provided copy of new fuel hose certificate.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 13 December 2011
Resolved
Electrical Room, type B-V fire extinguisher required to be secured for sea.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 15 December 2011
Resolution: Visually verified type B-V fire extinguisher secured for sea.
Engineering › Fuel Oil Service System › Piping
Issued 13 December 2011
Resolved
Port Generator fuel line leaking. Vessel shall repair/replace to satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2011
Resolution: Visually verified new fuel line elbow installed. No leaks.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 December 2011
Resolved
Oily water seperator no longer in service. Vessel shall repair or remove oily water seperator to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 December 2011
Resolved 23 December 2011
Resolution: I-Barge does not have a bilge, and does not require oily water seperator installed IAW 33 CFR 155.360(d). Visually verified old oily water seperator was removed, properly blanked off, with no possibility of discharge overboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 January 2011
Resolved
Vsl must provide satisfactory testing of OWS
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 18 February 2011
Resolution: Corrected to the satisfaction of the attending CG inspector.
Lifesaving › Lifebuoys › Stowage
Issued 26 January 2011
Resolved
Permenantly mount brackets for lifebuoy
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2011
Resolved
Middle navigational lights need to be fixed.
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 26 January 2011
Resolved
Properly secure fire protection above port generator
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Engineering › Generator (propulsion-electric) › Heating Element Circuitry
Issued 26 January 2011
Resolved
Replace lagging on starboard exhaust
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 January 2011
Resolved
Make wire penetration in starboard generator room watertight bulkhead watertight
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 18 February 2011
Resolution: Corrected to the satisfaction of the attending CG marine inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 January 2011
Resolved
Properly coil lifebuoy line
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the satisfaction of the Coast Guard Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 26 January 2011
Resolved
Install CO2 for paint locker or remove locker
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 24 February 2011
Resolution: Corrected to the Coast Guard Marine Inspector.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 26 January 2011
Resolved
Install liferafts to meet 46CFR199.10(h).
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 10 March 2011
Resolution: Vessel has installed liferafts to meet 46CFR199.10(h).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2009
Resolved
Provided operational smoke detectors to include detectors missing in berthing.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Engineering › Fuel Oil Service System › Hose
Issued 3 April 2009
Resolved
Provided annual hydro-static test on fuel hoses.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 April 2009
Resolved
Replace fuel hose nozzels with operational automatic back pressure nozzels.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 3 April 2009
Resolved
Demonstrate proper means of escape from engine room.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Fire Fighting › Grease Extraction Hood › General
Issued 3 April 2009
Resolved
Provide approval information on installed dry chem extinguishing system in galley (hood).
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2009
Resolved
Provided eye wash solution for eye wash station.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 7 April 2009
Documentation › Certificates/Documents › Stability Letter
Issued 13 November 2007
Resolved
Vessel needs to provide the Stability Letter.
Action required: 705 - Other - as specified
Resolved 6 March 2008
Resolution: Scanned in stability data as indicated from 20JUN1979.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 November 2007
Resolved
All open spaces need to be blanked off in electrical panel in the galley.
Action required: 705 - Other - as specified
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 November 2007
Resolved
The deep fat fryer and television need to be secured to the vessel.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Fire Fighting › Grease Extraction Hood › General
Issued 13 November 2007
Resolved
Service range fire supression system.
Action required: 705 - Other - as specified
Resolved 25 February 2008
Resolution: Vessel owner opted to remove the existing system.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 November 2007
Resolved
Ensure air conditioning venting is properly cleaned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 13 November 2007
Resolved
Ensure all food stores and refridgerator is sanitary.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2007
Resolved
Install covers on all light fixtures throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2007
Resolved
Ensure all emergency lighting is operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 13 November 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2007
Resolved
Ensure all smoke alarms are operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Nozzles › Condition
Issued 13 November 2007
Resolved
Install safety chains on all fire nozzles.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2007
Resolved
Ensure all smoke alarms are operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 November 2007
Resolved
Ensure all staterooms have bunk lights and locker per person.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 November 2007
Resolved
post lifejacket donning placard in each stateroom.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 13 November 2007
Resolved
Ensure all pluming in bathrooms is operational.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 November 2007
Resolved
Store all flammables in paint locker.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2007
Resolved
Install guards over all moving machinery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Engineering › Steam System (main) › Lagging/Insulation
Issued 13 November 2007
Resolved
Install lagging over all piping over 150 °F.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 November 2007
Resolved
Label all emergency escapes.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2007
Resolved
Install battery covers in machinery space.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 13 November 2007
Resolved
adjust handles on quick acting watertight door.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 November 2007
Resolved
Ensure stanchions meet 46 CFR subchapter I requirements.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 12 March 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 13 November 2007
Resolved
Install portable CO2 extinguisher on paint locker.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Resolution: The paint locker was removed from the vessel.
Engineering › Pressure Vessel › Weld
Issued 13 November 2007
Resolved
Makes pressure vessel available for inspection.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 November 2007
Resolved
Cap off open piping on day tank for hydraulic system.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 6 March 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 November 2007
Resolved
Provide fuel transfer procedures.
Due 31 March 2008
Resolved 13 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 November 2007
Resolved
Service the remote fuel shut off valve (starboard side - aft).
Due 31 March 2008
Resolved 12 March 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 November 2007
Resolved
Provide fire and safety plans.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Engineering › Lubricating Oil Service System › Tube
Issued 13 November 2007
Resolved
Install chaffing material as indicated on the prime mover.
Due 31 March 2008
Resolved 12 March 2008
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 13 November 2007
Resolved
The hydrostatic release units were not marked with the expiration date.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 November 2007
Resolved
The COD was not renewed.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 13 November 2007
Resolved
Provide COFR documentation.
Action required: 705 - Other - as specified
Resolved 12 March 2008
Electrical
Issued 23 February 1998
Resolved
REPAIR GROUND FAULT ON #2 S/S GENERATOR.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 30 January 1997
Resolved
REPAIR OR REPLACE THE OILY WATER SEPARATOR. DEMONSTRATE PROPER OPERATION FOR ISSUANCE OF THE IOPP CERTIFICATE.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Electrical
Issued 30 January 1997
Resolved
FIND AND REPAIR THE GROUND FAULT SHOWN ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Electrical
Issued 30 January 1997
Resolved
INSTALL A SHORE POWER INDICATOR LIGHT AS REQUIRED BY 46CFR111.30-25(f)(2)_x001C_ AND (g)(2).
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Accommodation/Occupational Safety
Issued 30 January 1997
Resolved
REMOVE THE ABONDONED AIR CONDITIONING UNIT FROM THE ENGINE ROOM.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Construction/Loadline
Issued 30 January 1997
Resolved
MAKE PERMANENT REPAIRS TO THE HOLED #5 PORT BALLAST TANK AND ADJACENT BULKHEAD.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Documentation
Issued 29 January 1996
Resolved
PROVIDE ON BOARD A USCG APPROVED SHIPBOARD OIL POLLUTION EMERGENCY RESPONSEPLAN (SOPEP).
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 8 February 1994
Resolved
INSTALL ALARM, MONITORING EQUIPMENT AND SYSTEM DISCHARGE SHUTDOWN DEVICE ONOILY WATER SEPERATOR SUITABLE FOR SYSTEM INSTALLED. SYSTEM IS NOT TO BE OPERATED UNTIL INSPECTED BY MARINE INSPECTOR.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Unknown
Issued 19 March 1985
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ON DECK FUEL TRANSFER SYSTEM.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR OILY WATER SEPARATOR.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985
Resolved
PROVIDE AND INSTALL COAST GUARD APPROVED OILY WATER SEPARATOR IN ACCORDANCEWITH 33 CFR 155.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL G/P 35 DN594130
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985