Records from 1999 to 2007. Most recent: inspection, 24 September 2007.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 September 2007
No resolution recorded
Battery was found loose under pilothouse console. Battery should be in approved container and held in place.
Due 21 October 2007 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 24 September 2007
No resolution recorded
The wires and cables under pilothouse console were in not held in place, there were bare connections and in general disarray. Repair above items to satisfaction of marine inspector.
Due 24 September 2007 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 24 September 2007
No resolution recorded
Two broken fixtures in E/R. Repair fixtures to satisfaction of attending Marine Inspector.
Due 24 September 2007 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 September 2007
No resolution recorded
Port generator was missing guards on generator. Replace guards where needed.
Due 21 October 2007 — due date passed with no resolution recorded
Engineering › Compressed Air System (start air) › Valve
Issued 24 September 2007
No resolution recorded
Install new pressure relief valves on air receivers. Old ones were painted over and suspect.
Due 21 October 2007 — due date passed with no resolution recorded
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 20 June 2006
Resolved
Vsl must provide a Radio Operator's permit for both licensed masters.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 21 June 2006
Resolution: Provided radio operator permit.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 6 October 2005
Resolved
Provide current ILLC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2005
Resolution: A.B.S. attended vessel and endorsed current ILLC.
Lifesaving › Rocket Parachute Flares › General
Issued 6 October 2005
Resolved
Provide required hand rockets IAW CFR's.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Resolution: 12 rockets provided.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 6 October 2005
Resolved
Provide required line throwing appliance and line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Resolution: SLTG and line provided.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 6 October 2005
Resolved
Place compass diviation table at operating station near compass.
Action required: 705 - Other - as specified
Due 6 November 2005
Resolved 7 October 2005
Resolution: Diviation table mounted at operating station.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 October 2005
Resolved
Empty bilges to suitable facility prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2005
Resolution: Bilges cleaned, recp''t provided as documentation.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 October 2005
Resolved
Install embarkation light fixture at liferaft embarkation station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Resolution: Light fixture installed and tested SAT.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 October 2005
Resolved
Provide redundant white all around masthead light.
Due 6 October 2005
Resolved 7 October 2005
Resolution: Light fixture install and working properly.
Construction/Loadline › Structures › Superstructure
Issued 15 November 2004
Resolved
Prior to departure from port, repair fractures to welds on stem in the vicinity of the forward #2 void.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2004
Resolved 18 November 2004
Resolution: Repairs completed.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2004
Resolved
Prior to departure from port, re-gauge and re-weld front and backside of new inserts on stem and forward port side of vessel. Prove water tight integrity by way of water test in presence of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2004
Resolved 18 November 2004
Resolution: Repairs completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 November 2004
Resolved
Prior to departure from port, prove proper operation of main engine overspeeds and oil shut downs in the presence of Marine Inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2004
Resolved 19 November 2004
Resolution: Operation proved.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2004
Resolved
Crop and renew: (a) port main deck in area of forward bulwark, (b) forward port hull in area of bulwark, (c) deck plate in forward #2 void, (d) indent in area of frames 4/5 in #2 bunk room, and (e) Starboard #2 gusset in forward #1 void. All to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Due 31 December 2004
Resolved 7 October 2005
Engineering › Pressure Vessel › Relief Valve
Issued 6 October 2004
Resolved
Adjust or replace port air receiver relief valve as per 46 CFR 54.15-10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 15 November 2004
Resolution: Port air received was replaced and operational.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 6 October 2004
Resolved
Test all main engine and generator prime mover overspeed trips and low lube oil pressure shutdowns as per 46 CFR 58.05.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 15 November 2004
Resolution: Generator overspeed trips and low lube oil shutdowns fully operational. This 835 cleared, with another 835 written for the main engine overspeed trips and low lube oil pressure shutdowns.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 October 2004
Resolved
Replace port shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 15 November 2004
Resolution: Port shaft was retightened and shaft seal no longer leaking.
Construction/Loadline › Markings › Load Line Mark
Issued 13 July 2004
Resolved
Place port side load line as per 46 CFR 42.13-30.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Load line properly configured.
Construction/Loadline › Hull › Stiffener
Issued 13 July 2004
Resolved
Insert overhead transverse angle in #2 Port rig water tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Gapped angle cropped and renewed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 13 July 2004
Resolved
Open port air receiver and make ready for internal examination as per 46 CFR 61.10-5.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Port air receiver internally examined.
Construction/Loadline › Hull › Stiffener
Issued 13 July 2004
Resolved
Repair fractured welds as marked in the steering flat.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Rewelded fractured welds.
Deck/Cargo › Ballast › Vents
Issued 13 July 2004
Resolved
Re-install tank vents/ball-valves as per 46 CFR 56.50-85(a)(7).
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Tank vent ball valves cleaned and re-installed.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2004
Resolved
Remove every tenth deck board on cargo deck to make deck available for inspection.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Deck boards removed to inspect deck plating. All satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2004
Resolved
Re-install topside deck lights as per 46 CFR 129.410.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: All lights re-installed.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 13 July 2004
Resolved
Repair port side containment plug as per 33 CFR 155.310.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Containment drain and plug repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2004
Resolved
Remove water in engineroom companionway to make bottom plate and structures available for inspection.
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 20 July 2004
Resolution: Water removed and space satisfactorily inspected.
Navigation › Piloting/Steering
Issued 24 September 2003
Resolved
Provide an up to date copy of the Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: Provided.
Documentation › Certificates/Documents
Issued 24 September 2003
Resolved
Provide an examined copy of the fuel oil transfer procedures. LEGACY COMPONENT DESC: Fuel transfer procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 23 February 2004
Resolution: stamped copy returned to owner/ operator
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Remove household (romex) type cable under pilothouse console and install proper marine cable. Properly secure cable and end splices. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Correct all power panel circuit cards to show the current carrying capacity of each circuit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: added.
Accommodation/Occupational Safety › Messroom
Issued 24 September 2003
Resolved
Properly secure the galley stove. LEGACY COMPONENT DESC: galley stove
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: secured
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 September 2003
Resolved
Replace all expired items. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: replaced.
Engineering › Bilge Water Management System
Issued 24 September 2003
Resolved
Provide and install a screw down valve and associated reach rod for the suction line forward of the collision bulkhead. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 23 October 2003
Resolution: Screw down valve and reach rod to the foscle deck installed and tested.
Engineering › Steering Gear System
Issued 24 September 2003
Resolved
Properly repair or replace the port steering ram. LEGACY COMPONENT DESC: Ram
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 25 September 2003
Resolution: replaced.
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Repair or replace the wiring to the engine room ventilation fan emergency shut-down switch and to the 01 level aft deck flood light. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: Repaired.
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Remove all extension cords serving as permanent wiring. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: removed.
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Provide and install protective cover for the fresh water pressure tank pressure switch. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: installed new pressure switch
Electrical › Lighting (emergency)
Issued 24 September 2003
Resolved
Provide and install 1 additional emergency egress light to illuminate the engine room emergency escape and hatch mechanism. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: Installed and demonstrated.
Electrical › Electrical Distribution System (service)
Issued 24 September 2003
Resolved
Provide bulbs for all power available lights on the main switch board. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: replaced
Construction/Loadline › Penetrations
Issued 24 September 2003
Resolved
Properly repair or remove and cap the piping penetration in the engine room emergency escape watertight bulkhead. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: penetration capped.
Engineering › Lubricating Oil Service System
Issued 24 September 2003
Resolved
Properly secure to prevent chafing of the port and starboard main engine and reduction gear lube oil drain hoses. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 25 September 2003
Resolved 25 September 2003
Resolution: secured.
Communications › Alarms/Indicators
Issued 24 September 2003
Resolved
Install a red lens on the engine room general alarm indicator light. LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 25 September 2003
Resolution: Installed
Communications › Internal Communications System
Issued 24 September 2003
Resolved
Provide a visual call indicator for the engine room station and install a back-up power supply for the telephone system. LEGACY COMPONENT DESC: telephone system
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 23 October 2003
Resolution: Visual call indicator and battery back-up power installed and tested.
Lifesaving › Buoyant Apparatus
Issued 24 September 2003
Resolved
Properly stencil the lifefloats. LEGACY COMPONENT DESC: markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 25 September 2003
Resolution: stencilled
Documentation › Certificates/Documents
Issued 11 October 2002
Resolved
Provide proof of Certification of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2002
Resolved 1 November 2002
Navigation › Piloting/Steering
Issued 11 October 2002
Resolved
Provide proof of compass deviation. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Communications › Alarms/Indicators
Issued 11 October 2002
Resolved
Repair smoke detectors throughout ship. LEGACY COMPONENT DESC: Fire Alarm
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Communications › Alarms/Indicators
Issued 11 October 2002
Resolved
Repair General Alarm Light in Engine Room. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2002
Resolved 11 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 11 October 2002
Resolved
Provide flame screen on hydraulic tank in Engine Room. LEGACY COMPONENT DESC: Flame Screens
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Fire Fighting › Remote Fuel Shutoff
Issued 11 October 2002
Resolved
Restencil fuel shut-offs on port main deck. LEGACY COMPONENT DESC: Labeling
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Lifesaving › Embarkation Appliances/Stations
Issued 11 October 2002
Resolved
Provide means of recuing injured person from water. LEGACY COMPONENT DESC: Stokes Litter
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2002
Resolved 11 October 2002
Fire Fighting › Means of Escape
Issued 11 October 2002
Resolved
Stencil Engine Room escape hatch on main deck. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Lifesaving › Line-Throwing Appliances
Issued 11 October 2002
Resolved
Provide one projectile for line-throwing kit. LEGACY COMPONENT DESC: Projectiles
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 14 October 2002
Lifesaving › Line-Throwing Appliances
Issued 11 October 2002
Resolved
Provide one service line for line throwing gun kit. LEGACY COMPONENT DESC: Lines
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 14 October 2002
Lifesaving › Buoyant Apparatus
Issued 11 October 2002
Resolved
Renew line for top lifefloat floatlight. LEGACY COMPONENT DESC: Floatlight
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Engineering › Fuel Oil Service System
Issued 11 October 2002
Resolved
Renew port main engine fuel supply hose. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2002
Resolved 11 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 October 2002
Resolved
Remove dead end wire on port main engine. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 11 November 2002
Resolved 11 October 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 11 October 2002
Resolved
Provide proof of stbd generator overspeed. LEGACY COMPONENT DESC: Overspeed Device
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2002
Resolved 11 October 2002
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 30 September 2002
Resolved
VESSEL OPERATED 82 DAYS BEYOND REQUIRED DRYDOCK DATE. LEGACY COMPONENT DESC: REQUIRED DRYDOCK
Action required: 705 - Other - as specified
Due 30 October 2002
Resolved 20 July 2004
Resolution: Completed credit drydock and ISE.
Documentation
Issued 30 August 2000
Resolved
PERMANENTLY MARK LOADLINE AND DECK REFERENCE MARK ONCE THE LOADLINE PLACEMENT IS VERIFIED BY ABS.
Condition: Unknown
Due 30 September 2000
Resolved 25 September 2000
Lifesaving
Issued 30 August 2000
Resolved
SECURE PADDLES TO LIFEFLOAT IAW 46 CFR 133.175.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Documentation
Issued 30 August 2000
Resolved
UPDATE SAFETY PLAN BY ADDING LOCATION OF LIFE JACKETS ON BRIDGE. _x001C_ 46 CFR 131.340
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Lifesaving
Issued 30 August 2000
Resolved
ENSURE ALL LIFE RINGS ARE STENCILED IAW 46CFR131.875
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Engineering
Issued 30 August 2000
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Engineering
Issued 30 August 2000
Resolved
STENCIL HYDRO DATES ON FUEL AND FIRE HOSES.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Fire Fighting
Issued 30 August 2000
Resolved
NUMBER ALL FIRE EXTINGUISHERS AND BULKHEADS. 46CFR132.210.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Construction/Loadline
Issued 30 August 2000
Resolved
ESCAPE HATCH NOT IN ACCORDANCE WITH 46CFR127.240, HOLD BACK DEVICE.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Fire Fighting
Issued 30 August 2000
Resolved
STENCIL VESSEL NAME ON FIRE AX. 46CFR131.880
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Lifesaving
Issued 30 August 2000
Resolved
INSTALL SPACERS BETWEEN LIFEFLOATS IAW 46 CFR 133.130.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Lifesaving
Issued 30 August 2000
Resolved
STENCIL VESSEL NAME ON PADDLES IAW 46 CFR 131.870 IN LIFEFLOATS.
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Documentation
Issued 30 August 2000
Resolved
VESSEL IS NOT TO OPERATE OUTSIDE THE BOUNDRY LINE (TWELVE MILES) UNTIL THE LOADLINE CERTIFICATE IS ISSUED BY CLASS. THE CERT MAYBE FAXED TO 334 441 5261. THIS ITEM MUST BE CORRECTED BY 30SEP00.
Condition: Unknown
Due 30 September 2000
Resolved 25 September 2000
Deck/Cargo
Issued 30 August 2000
Resolved
PROVE PROPER OPERATION OF ANCHOR WHILE VESSEL IS AT NORMAL LOAD AND BALLAST
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Lifesaving
Issued 30 August 2000
Resolved
ENSURE PROPER NUMBER OF WATERLIGHTS.
Condition: Unknown
Due 30 August 2000
Resolved 11 September 2000
Navigation
Issued 30 August 2000
Resolved
INSTALL LIGHT TO COMPASS 46CFR130.340
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Lifesaving
Issued 30 August 2000
Resolved
ENSURE WEAK LINKS ARE IN COMPLIANCE WITH 46CFR 133.130
Condition: Unknown
Due 30 August 2000
Resolved 11 September 2000
Engineering
Issued 30 August 2000
Resolved
REMOVE PET COCKS FROM RACOR FUEL WATER SEPERATOR AND OR REPLACE WITH PLUGS TO COMPLY WITH 46CFR 56.5
Condition: Unknown
Due 30 September 2000
Resolved 3 October 2000
Documentation
Issued 2 July 1999
Resolved
Submit data and obtain from G-MSC an approved, permanent Stability Letter.
Condition: Unknown
Due 14 September 1999
Resolved 27 October 1999
Documentation
Issued 2 July 1999
Resolved
Submit to G-MSC and resolve all outstanding comments, the following plans required by 46 CFR 127.110: Gen specifications, Electrical switchboards, Hydraulic steering, Through hull penetrations, Sanitary system, Tank soundings/capacities and draft marks.
Condition: Unknown
Due 14 September 1999
Resolved 27 October 1999