Records from 2004 to 2021. Most recent: inspection, 6 April 2021.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 11
6 April 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7169861
6 September 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6805724
27 June 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6656598
14 May 2018
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385771
3 August 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6223715
20 July 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6215566
20 July 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6297940
1 July 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6195941
1 May 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119371
12 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5847766
27 April 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5847762
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2019
No resolution recorded
A VESSEL THAT IS EXPOSED TO SALTWATER MORE THAN THREE MONTHS IN ANY 12 MONTH PERIOD SINCE THE LAST EXAMINATION MUST UNDERGO A DRYDOCK EXAMINATION AND AN INTERNAL STRUCTURE EXAMINATION AT LEAST ONCE EVERY TWO YEARS. VESSEL REQUIRED TO UNDERGO SATISFACTORY DRY DOCK / ISE EXAM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 July 2017
Resolved
Prove proper operation of STBD main propulsion system. 46CFR182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2017
Resolution: PROPELLERS AND SHAFTES WERE SERVICED BY WILMINGTON IRON WORKS AND WILMINGTON PROPELLER
Documentation › Certificates/Documents › FCC SSL
Issued 1 May 2017
Resolved
Obtain FCC Marine Radio Operator Permit. Operations limited to 1000 feet or less from shore. Cite: 47 CFR 80.159.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 16 May 2017
Resolution: Vessel master obtained valid FCC marine radio operator's permit.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 May 2017
Resolved
Remove unserviced B-I fire extinguisher from vessel.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Unserviced fire extinguisher removed from vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2017
Resolved
Post current COI in public area.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Current COI posted under glass.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 May 2017
Resolved
Post an instructions placard for each type of PFD used onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Two placards posted onboard.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 1 May 2017
Resolved
Post EAP information and 1-800 help hotline number onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: EAP information posted onboard.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 1 May 2017
Resolved
Place vessel name on 01 unmarked PFD.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Vessel name written on 01 unmarked PFD.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 May 2017
Resolved
Replace expired batteries in 03 floating electric waterlights.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Fresh batteries installed in 03 floating electric waterlights.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 May 2017
Resolved
Renew worn out retroreflective markings on ring lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: New retroreflective tapes afttached to ring life buoy.
Lifesaving › Lifefloat › Painter
Issued 1 May 2017
Resolved
Attach top lifeloat to painter with UV resistant line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Upper lifefloat attached to painter.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 May 2017
Resolved
Renew broken hose clamp on wet exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: New hose clamp installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 May 2016
Resolved
Provide audible indicator for all bilge high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Replaced bilge alarm electrical panel at operating station.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 May 2016
Resolved
Vessel was missing 06 Adult and 01 Child Type I PFDs required per COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: Vessel rep purchased additional Type I PFDs.
Lifesaving › Hand Flares › Quantity
Issued 12 May 2016
Resolved
Vessel was missing 03 orange smoke hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: Vessel rep purchased 03 additional hand flares.
Lifesaving › Lifefloat › Painter
Issued 12 May 2016
Resolved
Line connecting the 02 life floats together was improper.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: Vessel rep purchased new line which was installed.
Engineering › Bilge Water Management System › Valve
Issued 27 April 2016
Resolved
Install check valves in bilge suction lines for engine room, midbody compartment, & forepeak space. Stop-check valves also acceptable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Check valves installed.
Engineering › Bilge Water Management System › Strainer
Issued 27 April 2016
Resolved
Provide bilge suction strainer in mid body compartment w/ 3x open area of pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Strainer installed.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 April 2016
Resolved
Make toilet water supply valve available for inspection.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Valve innards presented in satisfactory condition.
Engineering › Bilge Water Management System › Hose
Issued 27 April 2016
Resolved
Install second hose clamp on hose fwd of collision bkhd for bilge suction.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Metal pipe installed in lieu of hose.
Engineering › Bilge Water Management System › Valve
Issued 27 April 2016
Resolved
Prove open/close operation of collision bkhd isolation valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 5 May 2016
Resolution: Valve proven to be operable.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 April 2016
Resolved
Install ball valves at hull penetrations and cycle during inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Ball valves installed properly.