MAURY USCG vessel records Sign in
← All vessels

EUROPA SUN

EUROPA SUN is a 1978 passenger vessel (inspected). The Coast Guard has recorded 123 inspections since 1982, most recently in January 2024, along with 324 deficiencies and 1 operational control.

Records from 1982 to 2024. Most recent: inspection, 27 January 2024.

Built
1978
Last inspected
27 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7807471 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-49818

Inspections, by type

…with no type recorded38
Years with a record 20 calendar years (1982–2024)
The 123 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
808 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
242 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OSG ENTERPRISE Towing Vessel · MISLE 154221 · 25 March 2005 · activity 2436017MOIRA MCALLISTER Towing Vessel · MISLE 667821 · 25 March 2005 · activity 2436017

Inspection history · 123

27 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856644
25 March 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2436017
21 July 2003 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1602308
31 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449493
23 April 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 116125
23 April 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1062523
12 April 2001 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1362122
9 February 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1058803
8 January 2001 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1448211
31 October 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 823932
21 July 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446963
21 April 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361423
4 April 2000 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1047088
26 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 637595
22 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 167797
14 January 2000 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 814853
7 January 2000 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 815253
29 December 1999 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453697
25 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 175839
29 September 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436267
1 September 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1411951
18 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431820
21 July 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369288
2 July 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086307
15 June 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1468071
13 May 1999 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1430679
10 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 178338
26 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461148
16 April 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789026
8 April 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378627
21 January 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1127863
8 January 1999 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1411783
16 December 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 667271
16 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 421505
8 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 14338
25 June 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1434745
2 April 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372188
11 January 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1121431
23 December 1997 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364477
17 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113907
23 September 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112797
17 September 1997 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388360
13 September 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 15198
24 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 217723
12 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 117841
30 June 1997 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416540
23 June 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 118160
17 March 1997 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1380792
20 December 1996 Deficiency Check · MARPOL Annex I Examination · Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094362
1 July 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1377756
14 March 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1357501
20 December 1995 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1394434
18 October 1995 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883722
25 September 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879500
25 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382183
25 August 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1383053
19 May 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183172
18 May 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931695
24 March 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149842
6 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 41662
21 December 1994 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163500
9 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 12833
8 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 180053
23 May 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1169521
1 March 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165629
4 January 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 853822
31 December 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850319
30 November 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850207
16 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848953
14 September 1993 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 837627
13 July 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 846985
14 June 1993 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152011
28 April 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840873
25 March 1993 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149170
8 December 1992 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 832769
25 August 1992 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1260962
27 May 1992 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 945344
26 February 1992 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309729
9 January 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1265458
2 December 1991 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268894
26 August 1991 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942498
28 May 1991 Certificate of Compliance · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906812
28 May 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1023604
28 May 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1220069
28 May 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330550
27 February 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 923692
22 January 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1209413
29 November 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235631
28 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 929963
7 November 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 928268
4 October 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 931453
19 September 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926310
16 August 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913843
4 August 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913961
12 July 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1294303
3 July 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227287
30 May 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903925
23 May 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1216808
11 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 905944
8 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913896
1 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 539139
31 January 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1241538
11 January 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 927411
17 November 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 931436
17 November 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1221798
28 September 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 930478
14 July 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1044374
31 May 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887387
17 April 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1346836
4 April 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1340634
1 March 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038311
1 March 1989 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207408
14 October 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897581
10 May 1988 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039882
24 March 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1344696
9 October 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015365
25 August 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031171
15 July 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330645
17 March 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326124
3 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308435
3 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967365
12 February 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276213
11 February 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969412

Deficiency record · 324

Lifesaving
Issued 31 July 2001 Resolved
Make emergency exit in engine room comply with requirements for emergency egress._x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Electrical
Issued 31 July 2001 Resolved
Replace light covers, stbd side stowage locker.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Construction/Loadline
Issued 31 July 2001 Resolved
Make repairs to STBD WTD on the bridge. CLASS to report as such.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Electrical
Issued 31 July 2001 Resolved
Remove all dead end wiring, wire knots, and electrical tape._x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Electrical
Issued 31 July 2001 Resolved
Repair PA speaker, aft third deck and 01 level deck stbd side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Unknown
Issued 31 July 2001 Resolved
Provide proof of air receiver internal inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Lifesaving
Issued 31 July 2001 Resolved
Make broadcast placard ship specific.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Lifesaving
Issued 31 July 2001 Resolved
Provide quick release mechanism for PFD stowage in way of overhead racks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Lifesaving
Issued 31 July 2001 Resolved
Label overhead life jacket stowage racks and indicate type and number.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Electrical
Issued 31 July 2001 Resolved
Repair emergency lights 2nd deck aft and 01 deck mid-ship.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Construction/Loadline
Issued 31 July 2001 Resolved
CLASS to address watertight integrity of QAWTD leading to aft steering from engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Construction/Loadline
Issued 31 July 2001 Resolved
Make watertight hatch leading from aft steering watertight and functional as emergency egress. CLASS to report as such._x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Construction/Loadline
Issued 31 July 2001 Resolved
Prove proper operation of alarms/indicators for all watertight doors. CLASSto report as such.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Navigation
Issued 23 April 2001 Resolved
Prior to departure, tighten or repair the port and starboard rudder stock so that water does not enter the vessel. Provide class report of sat repair.
Condition: Unknown
Due 23 April 2001
Resolved 24 April 2001
Navigation
Issued 23 April 2001 Resolved
Prior to departure, repair or replace leaking hydraulic oil leak at starboard rudder. Provide class report of sat repair.
Condition: Unknown
Due 23 April 2001
Resolved 24 April 2001
Navigation
Issued 23 April 2001 Resolved
Prior to departure, provide tech and class report of sat repairs to all steering components.
Condition: Unknown
Due 23 April 2001
Resolved 24 April 2001
Navigation
Issued 12 April 2001 Resolved
Provide magnetic compass deviation table after drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2001
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Lifesaving
Issued 12 April 2001 Resolved
Provide 2 additional self-lighting lights for Ring Bouys, IAW SOLAS III 7.1.3
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 8 January 2001 Resolved
Weld hole port side aft peak hold located 2 feet to the left of rudder postaccess.
Condition: Unknown
Due 28 February 2001
Resolved 9 January 2001
Construction/Loadline
Issued 8 January 2001 Resolved
Replace missing deck plate nuts to aft voids in steering flat.
Condition: Unknown
Due 28 February 2001
Resolved 9 January 2001
Accommodation/Occupational Safety
Issued 8 January 2001 Resolved
Replace missing deckplate access covers in engine room.
Condition: Unknown
Due 28 February 2001
Resolved 9 January 2001
Electrical
Issued 8 January 2001 Resolved
Install two (2) additional emergency lights in engine room. lights should be located forward end lighting aft between alleyways.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Engineering
Issued 8 January 2001 Resolved
Prove proper operation of #2 port and stbd reach rods for fuel tank shutoffs.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Navigation
Issued 8 January 2001 Resolved
Provide new compass deviation card after drydock in Feb 01.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Lifesaving
Issued 8 January 2001 Resolved
Provide IMO approved photoluminescent Lifesaving and Firefighting symbologyin order to comply with flag (PN) letter of 11 Jan 2000.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Fire Fighting
Issued 8 January 2001 Resolved
Prove proper operation of fire screen doors leading into galley.
Condition: Unknown
Due 8 January 2001
Resolved 9 January 2001
Fire Fighting
Issued 8 January 2001 Resolved
Secure portable fire extinguisher on bar.
Condition: Unknown
Due 8 January 2001
Resolved 9 January 2001
Lifesaving
Issued 8 January 2001 Resolved
By 11 Mar 01, provide life floats in place of existing buoyant apparatus per change to Subch "K".
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Lifesaving
Issued 8 January 2001 Resolved
Make rescue boat comply with 46 CFR 122 and Subchapter Q.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Navigation
Issued 8 January 2001 Resolved
Provide proper day shapes (diamond).
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Fire Fighting
Issued 8 January 2001 Resolved
Provide 2 full firemens outfits in order to comply with Flag (PN) letter of11 Jan 2000.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Lifesaving
Issued 8 January 2001 Resolved
Paint warning area (don not block) around rescue boat launching area. Areapainted should cover enough area to allow for proper launching and recovery.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Fire Fighting
Issued 8 January 2001 Resolved
Remove carpet immediately adjacent to bars.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Lifesaving
Issued 8 January 2001 Resolved
Properly secure CO2 bottle for soda machine under aft ladder on main deck.
Condition: Unknown
Due 1 February 2001
Resolved 9 January 2001
Electrical
Issued 8 January 2001 Resolved
repair/prove proper operation of emergency lights located maindeck aft (near bar), casino deck midships and casino deck fantail.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Documentation
Issued 8 January 2001 Resolved
Provide flag/class issued operations limitations manual (ltr).
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Documentation
Issued 8 January 2001 Resolved
provide onboard decision support system for emergency management iaw SOLAS III/24-4.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Lifesaving
Issued 8 January 2001 Resolved
Install additional public address speakers in galley, crew spaces under bridge on casino deck and aft of stack.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Navigation
Issued 8 January 2001 Resolved
Provide emergency steering change over/operation instructions on bridge andsteering space.
Condition: Unknown
Due 1 February 2001
Resolved 9 January 2001
Construction/Loadline
Issued 31 October 2000 Resolved
Repair/replace all main deck weathertight openings.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Navigation
Issued 31 October 2000 Resolved
Replace paper in NAVTEX.
Condition: Unknown
Due 15 November 2000
Resolved 20 November 2000
Lifesaving
Issued 31 October 2000 Resolved
Provide non-combustible waste receptacles throughout vessel.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 31 October 2000 Resolved
Replace expired smoke signals.
Condition: Unknown
Due 31 October 2000
Resolved 2 November 2000
Fire Fighting
Issued 31 October 2000 Resolved
Provide approved dampers for ventilation ducts.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 31 October 2000 Resolved
Provide remote shut off for ventilation on bridge.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Electrical
Issued 31 October 2000 Resolved
Remove all temporary power cords.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Electrical
Issued 31 October 2000 Resolved
Make safe all dead end cable/power cords throughout vessel.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 31 October 2000 Resolved
Provide Class report attesting to compliance with subchapter "K" structuralfire protection regs, specifically new bulkheads in surveillance and breakrooms. Remove walls or update FCP.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Navigation
Issued 31 October 2000 Resolved
Have Class address wastage in steering gear space.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Lifesaving
Issued 21 July 2000 Resolved
PRIOR TO 04AUG00 REMOVE ALL MACHINERY SPARES FROM WIRE TRACKS IN E/R.
Condition: Unknown
Due 4 August 2000
Resolved 8 August 2000
Unknown
Issued 21 July 2000 Resolved
prior to 04AUG00 install blanks in openings of all panel boards.
Condition: Unknown
Due 4 August 2000
Resolved 8 August 2000
Lifesaving
Issued 21 July 2000 Resolved
PROIR TO 04AUG00 PROVIDE PROPOSAL FOR VENTING WASTE OIL TANK IN E/R.
Condition: Unknown
Due 4 August 2000
Resolved 8 August 2000
Construction/Loadline
Issued 21 July 2000 Resolved
Prior to 04AUG00 CORRECT LOADLINE MARKINGS ON SIDESHELL.
Condition: Unknown
Due 4 August 2000
Resolved 8 August 2000
Documentation
Issued 21 April 2000 Resolved
PROVIDE VALID COFR
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 21 April 2000 Resolved
PROVE PROPER LATCHING AND OPERATION OF ALL EXTERIOR WEATHERTIGHT DOOR
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Electrical
Issued 21 April 2000 Resolved
REPAIR BROKEN LIGHT FIXTURES IN THE ENGINE ROOM.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Documentation
Issued 21 April 2000 Resolved
HAVE CLASS ADDRESS STRUCTURAL WASTAGE IN FOREPEAK TANK
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Engineering
Issued 21 April 2000 Resolved
REMOVE OLD WASTED BATTERIES FROM ENGINE ROOM.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Electrical
Issued 21 April 2000 Resolved
REPAIR OR RENEW EMERGENCY LIGHTS ON SECOND DECK FWD AND AFT LEADING TO STAIRS AND IN GALLEY.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Engineering
Issued 21 April 2000 Resolved
REPAIR GASKET ON AIR STARTER LUBRICATION CONTAINER ON PORTSIDE MAIN ENGINE
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Documentation
Issued 21 April 2000 Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREW MEMBERS.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Lifesaving
Issued 21 April 2000 Resolved
REPLACE WORN RETRO-REFLECTIVE TAPE ON 70 LIFEJACKETS
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Fire Fighting
Issued 21 April 2000 Resolved
REMOVE PAINT AND MAKE OPERABLE FIREMAIN ISOLATION VALVES AROUND MAIN FIRE PUMP.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 21 April 2000 Resolved
CROP AND RENEW FIREMAIN PIPING ABOVE FIREPUMP ON ENGINE ROOM.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Accommodation/Occupational Safety
Issued 21 April 2000 Resolved
SANITIZE AND FUMIGATE ALL FOOD HANDLING SPACES
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Lifesaving
Issued 21 April 2000 Resolved
REPLACE LIFERING ON STBD BRIDGEWING
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 21 April 2000 Resolved
REPEAT FIRE DRILL IN PRESCENCE OF USCG INSPECTOR
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Electrical
Issued 21 April 2000 Resolved
REPAIR #1 MAIN GENERATOR.
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Documentation
Issued 21 April 2000 Resolved
EXPAND AND UPDATE ISM INSPECTION PROCEDURES FOR LIFESAVING, EMERGENCY LIGHTING, WEATHER/WATERTIGHT DOORS AND FIRE PUMP/PIPING.
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Navigation
Issued 21 April 2000 Resolved
PROVE PROPER OPERATION AND MAKE REPAIRS TO DEPTH SOUNDER TRANSDUCER
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Construction/Loadline
Issued 4 April 2000 Resolved
Make permanent repair to 2 1/2 inch hole in the hull in way of the engine room. Near centerline keel, just aft of bulkhead. Provide a class society report addressing the repair and hull evaluation, prior to the carriage of passengers.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Construction/Loadline
Issued 7 January 2000 Resolved
PROVIDE CAPTIVE CHAINS ON 3 FORWARD AND 1 AFT FLUSH DECK HATCH.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Fire Fighting
Issued 7 January 2000 Resolved
PROVIDE DUPLICATE FIRE CONTROL PLAN IN WEATHERTIGHT ENCLOSURE OUTSIDE THE NAVIGATION BRIDGE.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Construction/Loadline
Issued 7 January 2000 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE BROKEN REACH ROD AND BILGE VALVE FOR FOREPEAK TANK SUCTION.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Fire Fighting
Issued 7 January 2000 Resolved
REMOVE AIR CONDITIONING WALL UNIT FROM PORTLIGHT IN GALLEY STORES PORT SIDE.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Navigation
Issued 7 January 2000 Resolved
PROVIDE ONBOARD NEW NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 7 January 2000 Resolved
REPLACE PORT AND STARBOARD BRIDGE WING WATERLIGHTS.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 29 December 1999 Resolved
PRIOR TO DEPARTURE WITH PASSENGERS, PROVIDE REPORT OF DAMAGE FROM SHIPYARD OR FLAG STATE REP TO INCLUDE ESTIMATED TIME AND DATE OF COMPLETED REPAIRS.
Condition: Unknown
Due 29 December 1999
Resolved 7 January 2000
Engineering
Issued 29 December 1999 Resolved
PRIOR TO DEPARTURE WITH PASSENGERS, PROVIDE SURVEYOR'S REPORT OF SATISFACTORY PROPULSION TEST FOLLOWING SHAFT (STBD) REPLACEMENT.
Condition: Unknown
Due 29 December 1999
Resolved 7 January 2000
Unknown
Issued 29 December 1999 Resolved
PRIOR TO DEPARTURE WITH PASSENGERS, PROVIDE FLAG SURVEYOR'S REPORT ATTESTING TO VESSEL'S OVERALL FITNESS FOR ROUTE AND SERVICE.
Condition: Unknown
Due 30 December 1999
Resolved 7 January 2000
Documentation
Issued 29 December 1999 Resolved
PRIOR TO DEPARTURE WITH PASSENGERS, PROVIDE STATEMENT REGARDING ISM CODE.SMS PROCEDURES RELATING TO EMERGENCY PROCEDURES AND NOTIFICATIONS OF CASUALTIES. DESCRIBE HOW SMS REQUIRES REPORTING.
Condition: Unknown
Due 30 December 1999
Resolved 7 January 2000
Unknown
Issued 29 December 1999 Resolved
PRIOR TO DEPARTURE WITH PASSENGERS, SUBMIT Y2K QUESTIONNAIRE TO MSO MIAMI.
Condition: Unknown
Due 30 December 1999
Resolved 7 January 2000
Electrical
Issued 1 September 1999 Resolved
By 14SEP99, provide rubber matting for all power panels in engineroom.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Engineering
Issued 1 September 1999 Resolved
By 14SEP99, replace site glass to fuel tank in engineroom.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Electrical
Issued 1 September 1999 Resolved
By 14SEP99, re-route battery cables IWO main generator away from portable fire extinguisher.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Electrical
Issued 1 September 1999 Resolved
By 14SEP99, remove combustible material from above electrical cables in passageway forward of engineroom.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Engineering
Issued 1 September 1999 Resolved
By 14SEP99, replace shaft packing seals for port/stbd shafts.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Electrical
Issued 1 September 1999 Resolved
By 14SEP99, remove portable electric cords and hard wire emergency lightingin engineroom.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Unknown
Issued 1 September 1999 Resolved
By 14SEP99, adjust second deck, stbd aft glass door.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Electrical
Issued 1 September 1999 Resolved
By 14SEP99, provide blank face plates to 220 vac panel in engineroom.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Documentation
Issued 18 August 1999 Resolved
PROVIDE PROOF OF VALID CUSTOMS BOND PRIOR TO DEPARTURE ON 18 AUG 99.
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Documentation
Issued 18 August 1999 Resolved
PROVIDE VALID CERTIFICATE OF REGISTRY PRIOR TO DEPARTURE ON 18 AUG 99.
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Engineering
Issued 21 July 1999 Resolved
INSTALL FLAME SCREEN IN STBD SEWAGE VENT.
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Navigation
Issued 21 July 1999 Resolved
REPAIR THE NO.2 RADAR WHICH SHORTS OUT WHEN THE RANGE KNOB IS ADJUSTED.
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Unknown
Issued 21 July 1999 Resolved
SECURE CO2 BOTTLES IN GALLEY.
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Engineering
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, PERMANENTLY INSTALL MACHINERY GUARDS ON BILGE/BALLAST ANDFIRE PUMPS.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Accommodation/Occupational Safety
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, FUMIGATE GALLEY TO EXTERMINATE INSECTS.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Navigation
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, PROVIDE COPY OF COAST GUARD LIGHT LIST VOLUME III ON BOARD THE VESSEL.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, PROVIDE CLASS REPORT ATTESTING TO ADEQUACY AND PROPER OPERATION OF GENERAL ALARM (BOTH VISUAL AND AUDIBLE) IN ENGINE ROOM.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Documentation
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, PROVIDE CLASS SURVEYORS REPORT TO USCG ATTESTING TO CORRECTION OF ALL OUTSTANDING DEFS ISSUED ON BOARDING REPORT DATED 15JUN99.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Navigation
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, REPAIR LEAK ON PORT HYDRAULIC STEERING RAM.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Accommodation/Occupational Safety
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, INSTALL CHECK VALVE/BALL ON POTABLE WATER TANK VENT STARBOARD SIDE, AND INCLUDE BUG SCREEN.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Construction/Loadline
Issued 15 June 1999 Resolved
PRIOR TO 25JUN99, ADJUST THE THREE WATERTIGHT DOORS IN THE MACHINERY SPACESTO RESTORE PROPER OPERATION AND THAT NO AIR ESCAPES FROM KNIFE EDGES.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Electrical
Issued 13 May 1999 Resolved
Provide for review, electrical system plans stamped approved by the vessel's Flag Administration or authorized representative IAW 46 CFR 116.202 (a)(6)(i), (iv), (vi), & (viii).
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 13 May 1999 Resolved
Do not use #3 generator after repairs to its primemover (12v71 Detroit Diesel) until a suitable interlock device is installed to prevent the generators (1, 2, & 3) from being simultaneously connected to the switchboard IAW 46 CFR 120.322(b).
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, secure 2 cigarette machines on main deck below bridge.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, re-stencil four lifejackets with ship's proper name (EUROPA SUN, not EUROPE SKY), IAW 46CFR122.604.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, re-stencil three life rings (port and starboard side of bridge, and starboard side casino deck) so ship's name does not cover retro-reflective tape, IAW 46CFR122.604.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, replace EPIRB registeration that expired on 31MAR99.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Documentation
Issued 8 April 1999 Resolved
Commencing immediately, log all required drills and maintenance.
Condition: Unknown
Due 8 April 1999
Resolved 14 April 1999
Engineering
Issued 8 April 1999 Resolved
Prior to 15APR99, repair leak in cooling water piping for starboard main diesel engine IAW 46CFR119.420.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Engineering
Issued 8 April 1999 Resolved
Prior to 15APR99, provide machinery guard for rotating equipment on port main diesel engine IAW 46CFR116.920.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Electrical
Issued 8 April 1999 Resolved
Prior to 15APR99, make port emergency generator operable (2 bent push rods)IAW 46CFR120.320.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Electrical
Issued 8 April 1999 Resolved
Prior to 15APR99, secure all battery boxes in Engineroom IAW 46CFR120.350(b).
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Fire Fighting
Issued 8 April 1999 Resolved
Prior to sailing, correctly mount smoke detector in port storage room of galley, IAW 46CFR118.400.
Condition: Unknown
Due 8 April 1999
Resolved 14 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, mark escape route out of steering flat IAW 146CFR116.500.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, replace lanyard for waterlight on buoyant apparatus in port outboard stack (not minimum 18ft) IAW 46CFR117.175.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, make reparations to sound powered phones in engineroom IAW 46CFR121.602.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, stencil "child" lifejacket stowage rack.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, provide lifejacket donning placard on 2nd deck.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Electrical
Issued 8 April 1999 Resolved
Prior to sailing, repair/replace main distribution breaker for casino deck IAW 46CFR120.330.
Condition: Unknown
Due 8 April 1999
Resolved 14 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, correctly attach sea painter on both stacks of buoyant apparatuses starboard side (sea painter not attached to two BA's) IAW 46CFR117.175.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, place spacers between buoyant apparatuses that are_x001C_ stacked, IAW 46CFR117.137.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999 Resolved
Prior to 15APR99, replace worn/peeled retro reflective tape on 37 lifejackets, IAW 46CF122.604.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Navigation
Issued 8 January 1999 Resolved
REPAIR STERN NAV. LIGHT PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 8 January 1999 Resolved
PROVIDE PROPER MARKINGS, RETRO-REFLECTIVE TAPE, WATERLIGHTS, WATERTIGHT LANYARD LENGHT OF 18FT ON ALL BA'S PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Fire Fighting
Issued 8 January 1999 Resolved
POST EMERGENCY FIRE INSTRUCTIONS IN LOCATIONS WHERE PASSENGERS CAN SEE PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 8 January 1999 Resolved
PROVIDE THE CORRECT AMOUNT OF RETRO-REFLECTIVE TAPE ON ALL LIFEBUOYS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 8 January 1999 Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33 C.F.R. 155.750 PRIOR TO BUNKERING, DISCHARGES AND INTERNAL TRANSFERS.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 8 January 1999 Resolved
IMMEDIATELLY BEGIN LOGGING EQUIPMENT CHECKS (LIFESAVING-FIREFIGHTING, ETC) BY 22JAN99
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Fire Fighting
Issued 8 January 1999 Resolved
LABEL FIRE DETECTION PANEL ON BRIDGE WITH PROPER SPACES SERVED BY DETECTORSNO LATER THAN 22JAN99.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999 Resolved
INSTALL AN ALARM BELL IN WAY FO THE ESSEL'S STERN PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 8 January 1999 Resolved
PROVE PROPE SIZE OF PAINTER ON ALL BUOYANT APPARATUS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 8 January 1999 Resolved
PROVIDE AND INSTALL CORRECT TYPE LANTERN BATTERIES FOR ALL WATERLIGHTS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999 Resolved
PROVIDE EMERGENCY LIGHTING IN EMERGENCY ESCAPE TRUNK (EXAUST STACK) BY 22JAN99.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Lifesaving
Issued 8 January 1999 Resolved
MAKE NAMEPLATE DATA AVAILABLE FOR INSPECITON IN WAQY OF BUOYANT APPARATUS BY 22JAN99.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999 Resolved
PROPERLY LABEL/IDENTIFY PASSENGER ESCAPE ROUTES THROUGHOUT THE VESSEL PRIORTO DEPARTURE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 16 October 1998 Resolved
No later than 20 Oct 98, the vessel is to conduct a joint ISM expanded examwith the designated person ashore, flag rep [name withheld] rep and USCG rep. Date and time of exam is to be scheduled at least 48 hours inadvance with MSO Miami, contact [name withheld], [phone withheld].
Condition: Unknown
Due 20 October 1998
Resolved 30 November 1998
Documentation
Issued 16 October 1998 Resolved
Provide originals of all licenses and seaman's papers for all officers and crew required by safe manning certificate. All required officers and crew to be onboard with their license or document and verified by USCG prior to embarking passengers.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Electrical
Issued 25 June 1998 Resolved
Remove all dead end wires located under bridge console, and wire nuts on loud hailer wiring.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 25 June 1998 Resolved
Remove wire nuts from wiring located in the junction box behind the band stage.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 25 June 1998 Resolved
Repair leaking flange on ballast pump.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Deck/Cargo
Issued 25 June 1998 Resolved
Repair brake assembly on port anchor windless.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 2 April 1998 Resolved
Make permanent repairs to port shaft packing.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Navigation
Issued 2 April 1998 Resolved
Reconfigure stern light location to conform with Intl/Inland navigaiton rules.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 2 April 1998 Resolved
Remove all debris and excess water from bilge spaces.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 2 April 1998 Resolved
Provide flag state surveyor's report on status of wasted longitudinals in steering compartment and status of steel in #6 Port/Starboard ballast tanksand aft void spaces.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 23 December 1997 Resolved
Complete repairs in way of wasted transverse and longitudinal non- watertight bulkheads in the vessel's chain/rope locker to the satisfaction of the vessel class surveyor and attending USCG marine inspector.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Electrical
Issued 17 September 1997 Resolved
PROVIDE LIGHTING IN WAY OF EMERGENCY EXIT IN STEERING SPACE.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Engineering
Issued 17 September 1997 Resolved
REPAIR WATER LEAK IN WAY OF A/C CONDENSOR (LOWER FLANGE.)
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Lifesaving
Issued 17 September 1997 Resolved
REMOVE WIRE TIES AND RIG/CONNECT BUOYANT APPARATUS OARS TO EACH BUOYANT APPARATUS FOR IMMEDIATE USE.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Construction/Loadline
Issued 17 September 1997 Resolved
ADJUST ENGINEROOM ACCESS WATER TIGHT DOOR (FROM GALLEY TO ENGINEROOM.)
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Navigation
Issued 17 September 1997 Resolved
EDUCT ALL STANDING WATER FROM STEERING COMPARTMENT AND MAKE READY/VENTILATEFOR INSPECTION.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Engineering
Issued 17 September 1997 Resolved
REPAIR HYDRAULIC PUMP LEAK IN WAY OF BOW THRUSTER.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Engineering
Issued 17 September 1997 Resolved
REPAIR/REPLACE BOW THRUSTER RELAY BOX (CURRENT BOX CRACKED AND HINGES BROKEN.)
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Accommodation/Occupational Safety
Issued 17 September 1997 Resolved
CLEAN OIL/RESIDUE IN WAY OF DECK BELOW BOW THRUSTER PUMP.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997 Resolved
PROVIDE JUNCTION BOX COVER ON PORT SIDE BULK HEAD OUTBOARD OF PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 17 September 1997 Resolved
PROVIDE LEGIBLE FIRE CONTROL PLAN AND POST IN ACCORDANCE WITH 46 CFR 116.530. (CURRENT PLAN IS SMALL PHOTO-COPY OF VESSEL'S STRUCTURE ONLY)
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997 Resolved
REMOVE ALL DEAD-END WIRES, SPLICED ELECTRICAL CONNECTIONS, EXPOSED WIRES, HOUSE-HOLD EXTENSION CORDS/JUNCTION BOXES, ETC. RUN WIRES THROUGH PROPER ELECTRICAL CONDUITS AND CABLE RUNS. (NOTED INPROPER WIRING IN NUMEROUS LOCATIONS, SEE MINS - MI97033282 FOR DETAILS.)
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997 Resolved
PROVIDE LIGHT COVERS FOR EXPOSED LIGHTING IN GALLEY STORAGE AND IN GALLEY.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997 Resolved
PROVIDE LIGHT COVERS FOR EXPOSED LIGHTS IN ENGINE ROOM.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Lifesaving
Issued 17 September 1997 Resolved
REPLACED CRACKED WATERLIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Engineering
Issued 17 September 1997 Resolved
REPLACE DAMAGED FLAME SCREENS ON PORT/STARBOARD BUNKER STATIONS FUEL VENTS AND LUBE OIL TANK VENTS PRIOR TO BUNKER U.S. WATERS.
Condition: Unknown
Due 17 September 1997
Resolved 23 September 1997
Lifesaving
Issued 17 September 1997 Resolved
PROVIDE EMERGENCY EVACUATION PLACARDS FOR DIRECTION TO EMBARKATION/MUSTER STATIONS THROUGH OUT VESSEL.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 17 September 1997 Resolved
REPAIR HOLES IN DOOR BETWEEN MAIN CASINO AND TRANSVERSE WALKWAY (AFT OF PILOT HOUSE ACCESS).
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Accommodation/Occupational Safety
Issued 30 June 1997 Resolved
GALLEY RANGE HOOD DUCT WAS NOTED WITH GREASE RUNNING DOWN OUTSIDE STBD SIDEOF VESSEL.
Condition: Unknown
Due 30 June 1997
Resolved 5 August 1997
Lifesaving
Issued 30 June 1997 Resolved
BUOYANT APPARATUS TENDING LINES WERE ENTANGLED AND STOWED IMPROPER. SUPPORTSTANCHIONS ARE NOT HIGH ENOUGH TO HOLD THE BA'S DURING HEAVY WEATHER. A FEW SPACERS BETWEEN BA'S WERE MISSING.
Condition: Unknown
Due 7 July 1997
Resolved 5 August 1997
Engineering
Issued 30 June 1997 Resolved
VENT PIPES FOR FUEL TANKS MISSING FLAME SCREENS.
Condition: Unknown
Due 7 July 1997
Resolved 5 August 1997
Engineering
Issued 30 June 1997 Resolved
PORT SIDE EMERGENCY FUEL OIL SHUT-OFF REMOTE REACHROD HEX HEAD ROUNDED OFF.
Condition: Unknown
Due 7 July 1997
Resolved 5 August 1997
Construction/Loadline
Issued 30 June 1997 Resolved
QUICK ACTING WATER TIGHT DOORS TO ENGINE ROOM BOTH FWD AND AFT WERE MISSINGPARTS SO THE DOOR WOULD NOT CLOSE CORRECTLY. CORRECTED DEFICIENCIES DURING INSPECTION.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Engineering
Issued 30 June 1997 Resolved
PROVIDE AND INSTALL EXHAUST LAGGING FOR PORT GENERATOR PIPING.
Condition: Unknown
Due 7 July 1997
Resolved 5 August 1997
Engineering
Issued 30 June 1997 Resolved
PROVIDE AND INSTALL GUARDS OVER ROTATING MACHINERY IN ENGINE ROOM. EQUIPMENT THAT NEEDS TO BE SHIELDED; 1 AND 2 AIR COMPRESSORS AND SHIP SERVICE GENERATOR.
Condition: Unknown
Due 7 July 1997
Resolved 5 August 1997
Lifesaving
Issued 17 March 1997 Resolved
Replace worn and weathered retro-reflective material on PFDs.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 17 March 1997 Resolved
Provide additional alarms in accommodation spaces to be audible throughout vessel.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 17 March 1997 Resolved
Provide appropriate fire hose for machinery space.
Condition: Unknown
Due 17 March 1997
Resolved 27 March 1997
Electrical
Issued 20 December 1996 Resolved
Remove wirenuts from under the pilothouse console and properly make wire conections.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Construction/Loadline
Issued 20 December 1996 Resolved
Provide a watertight hatch for the main deck access to the steering compartment. To be completed prior to departure.
Condition: Unknown
Due 20 December 1996
Resolved 17 March 1997
Fire Fighting
Issued 20 December 1996 Resolved
Properly mount the galley CO2 portable fire extinguisher.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Documentation
Issued 20 December 1996 Resolved
Provide proper written oil transfer procedures. To be completed prior to next bunkering.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Lifesaving
Issued 20 December 1996 Resolved
Provide sufficient retro-reflective tape for the ring buoy located forward,starboard side.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Electrical
Issued 20 December 1996 Resolved
Provide proper fixed lighting fixtures in the passageway leading to the engine room.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Electrical
Issued 20 December 1996 Resolved
Properly label the bridge breaker panels.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Fire Fighting
Issued 20 December 1996 Resolved
Properly repair the fire main leak in the engine room.
Condition: Unknown
Due 20 December 1996
Resolved 17 March 1997
Electrical
Issued 20 December 1996 Resolved
Properly repair the light fixture in the crews head.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Electrical
Issued 20 December 1996 Resolved
Properly repair emergency lighting on the upper casino deck, aft.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Lifesaving
Issued 20 December 1996 Resolved
Remove combustible materials from the forward accommodation space.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Documentation
Issued 20 December 1996 Resolved
Provide a radio operators permit for the master.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Electrical
Issued 20 December 1996 Resolved
Reposition emergency lighting on the upper casino deck, aft.
Condition: Unknown
Due 3 January 1997
Resolved 17 March 1997
Navigation
Issued 20 December 1996 Resolved
Provide chart #11468.
Condition: Unknown
Due 20 December 1996
Resolved 17 March 1997
Fire Fighting
Issued 20 December 1996 Resolved
Properly mount the smoke detector in the forward accommodation space.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Documentation
Issued 20 December 1996 Resolved
Provide a SOLAS exemption certificate showing that the vessel is in full compliance with 46 CFR subchapter K.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Documentation
Issued 1 July 1996 Resolved
Provide on board for review, stability information approved by the vessel'sFlag Administration or Classification Society as required by the International Load Line Convention. The stability letter issued by the U.S. Coast Guard on 27 March 1987 is no longer valid.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Fire Fighting
Issued 1 July 1996 Resolved
Renew wasted firepump by pass piping.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Construction/Loadline
Issued 1 July 1996 Resolved
Replace PVC bilge piping between the bilge pumps with the original material(steel).
Condition: Unknown
Due 15 July 1996
Resolved 20 July 1996
Lifesaving
Issued 20 December 1995 Resolved
INSTALL/PROVIDE A MEANS FOR PASSENGERS TO ENTER WATER OTHER THAN JUMPING._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 20 December 1995 Resolved
PROVIDE READY ACCESS TO ALL BALLAST TANK TUBES._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Lifesaving
Issued 20 December 1995 Resolved
DEVELOP/PROVIDE WRITTEN PROCEDURES FOR DEPLOYMENT OF BOUYANT APPARATUS, ANDEMBARKATION OF PASSENGERS TO SAME (INCLUDE HANDICAPPED)._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Lifesaving
Issued 20 December 1995 Resolved
INSTALL FITTINGS (CLEATS) TO TEND BOUYANT APPARATUS DURING EMERGENCY EMBARKATION._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Unknown
Issued 20 December 1995 Resolved
PROVIDE ADEQUATE NUMBER OF PORTABLE EMERGENCY LIGHTS TO AID IN ABANDON SHIP._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Documentation
Issued 20 December 1995 Resolved
PROVIDE AN ORGINAL CHIEFS ENGINEERS LICENSE._x001C_
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 18 October 1995 Resolved
Make permanent repairs to holed bottom plate in number 4 starboard ballast tank.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Fire Fighting
Issued 25 August 1995 Resolved
Provide additional B-II extinguisher for engine room.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Navigation
Issued 25 August 1995 Resolved
Replace steering crosspipe where corroded.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Repair door closures galley and main dk doors.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Fire Fighting
Issued 25 August 1995 Resolved
Repair fire alarm galley.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Include in Training Manual the procedures to embark into lifefloats.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 25 August 1995 Resolved
Provide approved stability information as required by Load Line Convention,1966, Reg. 10
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Make Training Manual readily available to crew.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Construction/Loadline
Issued 25 August 1995 Resolved
Identify and make accessible all sounding tubes for ballast tanks.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
Install emergency lighting at lifefloat embarkation stations.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 25 August 1995 Resolved
replace retroreflective tape on lifejackets.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Lifesaving
Issued 19 May 1995 Resolved
LABEL STOWAGE LOCKERS FOR CHILD PFDS PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Lifesaving
Issued 19 May 1995 Resolved
REMOVE PFD STOWAGE LABELS WHERE NOT STOWED IN FWD DECK LOCKERS PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Fire Fighting
Issued 19 May 1995 Resolved
MAKE PERMANENT REPAIRS IN WAY OF SOFT PATCH ON BALLAST PIPING IN E/R.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Electrical
Issued 19 May 1995 Resolved
PROVIDE COVER FOR BATTERY BOX IN E/R.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
PROVIDE OIL TRANSFER PROCEDURES PRIOR TO BUNKERING IN U.S. WATERS.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Fire Fighting
Issued 21 December 1994 Resolved
REPLACE MISSING "A" DOOR FWD BOUNDARY OF CASINO SPACE.
Condition: Unknown
Due 21 December 1994
Resolved 21 December 1994
Construction/Loadline
Issued 21 December 1994 Resolved
PERMANENTLY ENSCRIBE AND PAINT C1 MARK ON HULL IAW LOADLINE CERTIFICATE.
Condition: Unknown
Due 21 December 1994
Resolved 21 December 1994
Electrical
Issued 23 May 1994 Resolved
Hardwire lighting fixture on casino deck aft at outside bar.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Electrical
Issued 23 May 1994 Resolved
Repair exhaust fan motor in port dry stores in galley.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Engineering
Issued 23 May 1994 Resolved
Replace emergency fuel shut off valve "T" handles.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Electrical
Issued 23 May 1994 Resolved
Repair emergency light in casino deck forward at doorway.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Engineering
Issued 14 September 1993 Resolved
Repair starboard engine room exhaust fan controller.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Provide check valve for #6 starboard vent gooseneck pipe located on main deck.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Accommodation/Occupational Safety
Issued 14 September 1993 Resolved
Renew two missing J-bolts in tonnage door (main deck)
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Accommodation/Occupational Safety
Issued 14 September 1993 Resolved
Provide written waste management plan.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Repair bilge alarm aft engine room passageway.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Engineering
Issued 14 June 1993 Resolved
Renew flame screens on following vents: 1) port lube oil tank, 2) main engine lube oil tank.
Condition: Unknown
Due 14 June 1993
Resolved 14 June 1993
Construction/Loadline
Issued 14 June 1993 Resolved
Replace bug screen on P/S potable water vents.
Condition: Unknown
Due 14 June 1993
Resolved 14 June 1993
Construction/Loadline
Issued 14 June 1993 Resolved
Replace ball check valve #7 tank vent.
Condition: Unknown
Due 14 June 1993
Resolved 14 June 1993
Lifesaving
Issued 14 June 1993 Resolved
Install spacers between each buoyant apparatus - forward.
Condition: Unknown
Due 14 June 1993
Resolved 14 June 1993
Lifesaving
Issued 14 June 1993 Resolved
Label vessels name on all buoyant appratus' aft.
Condition: Unknown
Due 14 June 1993
Resolved 14 June 1993
Engineering
Issued 25 March 1993 Resolved
REPAIR AND PROVE OPERATION OF BOW THRUSTER TRANSFER SWITCH ON BRIDGE CONSOLE.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Electrical
Issued 25 March 1993 Resolved
RELOCATE MID-SHIPS FORWARD EMERGENCY LIGHT TO ILLUMINATE FORWARD EXIT FROM ENGINE ROOM.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Electrical
Issued 25 March 1993 Resolved
RENEW 12-71 SERVICE GENERATOR FLEXIBLE EXHAUST PIPES.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Lifesaving
Issued 25 March 1993 Resolved
STENCIL EACH STOWAGE LOCATION OF CHILDS LIFEJACKETS WITH "CHILD" AND NUMBEROF JACKETS STOWED.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Lifesaving
Issued 8 December 1992 Resolved
Renew 94 adult PFD's.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Electrical
Issued 8 December 1992 Resolved
Remove or reattach 3 exposed wires beneath 3 phase switch board.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Lifesaving
Issued 8 December 1992 Resolved
Stow loose gear/equipment aft of 6-71 generator
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Lifesaving
Issued 8 December 1992 Resolved
Repair or renew two l/floats of aft deck. (grab line retaining, loops frayed/worn)
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Electrical
Issued 8 December 1992 Resolved
Replace cover on air conditioner compressor junction box port side of engineroom.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Construction/Loadline
Issued 8 December 1992 Resolved
Repair ballast discharge piping-port side- forward engineroom.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Engineering
Issued 8 December 1992 Resolved
Prove operation of overspeed trips on both main diesel engines.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Electrical
Issued 25 August 1992 Resolved
Provide emergency lighting for forward access to casino deck.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Electrical
Issued 25 August 1992 Resolved
Provide emergency lighting for forward access at engine room entrance.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Accommodation/Occupational Safety
Issued 26 February 1992 Resolved
PROVIDE PERMANENT RACKS FOR N2 CYLINDERS.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Fire Fighting
Issued 26 February 1992 Resolved
REPLACE 1 OF 9 FIRE HOSE NOZZLES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Electrical
Issued 26 February 1992 Resolved
ADD ADDITIONAL OUTLETS IN CASINO CHANGE ROOM.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Lifesaving
Issued 2 December 1991 Resolved
REPLACE PADDLE IN LIFEFLOAT, AFT BRIDGE.
Condition: Unknown
Due 16 December 1991
Resolved 13 January 1992
Lifesaving
Issued 2 December 1991 Resolved
REPLACE 9 ADULT PFD'S. TOTAL PASSENGERS LIMITED TO 489 UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 16 December 1991
Resolved 13 January 1992
Lifesaving
Issued 2 December 1991 Resolved
RENEW REFLECTIVE TAPE ON LIFEFLOATS AS NEEDED.
Condition: Unknown
Due 16 December 1991
Resolved 13 January 1992
Lifesaving
Issued 2 December 1991 Resolved
SEAL PUNCTURES IN LIFEFLOATS AS NEEDED.
Condition: Unknown
Due 16 December 1991
Resolved 13 January 1992
Lifesaving
Issued 28 May 1991 Resolved
REPLACE 1 CRACKED OAR - STBD AFT RAFT WITHIN 7 DAYS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Engineering
Issued 28 May 1991 Resolved
REPAIR STBD BOW THRUSTER CONTROLS WITHIN 7 DAYS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Accommodation/Occupational Safety
Issued 28 May 1991 Resolved
REPAIR MAIN DECK LADIES TOILET EXHAUST FAN WITHIN 7 DAYS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Lifesaving
Issued 28 May 1991 Resolved
REPAIR BY WELDING - 3 LIFE FLOAT PLATFORMS WITHIN 7 DAYS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Unknown
Issued 28 May 1991 Resolved
DEMONSTRATE BILGE PUMP OPERATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Lifesaving
Issued 28 May 1991 Resolved
PROVIDE 2 ADDITIONAL RED HAND HELD FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Lifesaving
Issued 28 May 1991 Resolved
REPAIR ONE LIFE FLOAT LIGHT WITHIN 7 DAYS.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Engineering
Issued 28 November 1990 Resolved
REPAIR PORT MAIN ENGINE OIL PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Fire Fighting
Issued 7 November 1990 Resolved
REPLACE PLASTIC FIRE HOSE NOZZLE WITH BRONZE NOZZLE ON 2ND DECK STARBOARD SIDE.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990 Resolved
REPAIR STARBOARD MAIN ENGINE OIL PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Lifesaving
Issued 7 November 1990 Resolved
PROVIDE 11 CHILD LIFE PRESERVERS AND 151 ADULT LIFE PRESERVERS (TOTAL 492 ADULT AND 50 CHILD). UNTIL COMPLETED VESSEL IS LIMITED TO 279 ADULT PASSENGERS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Deck/Cargo
Issued 7 November 1990 Resolved
REPAIR MAIN DECK REMOTE VENT SHUTDOWN PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Electrical
Issued 7 November 1990 Resolved
REPAIR MOTOR FOR MAIN AIR COMPRESSOR AND PROVE PROPER OPERATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Fire Fighting
Issued 7 November 1990 Resolved
REPAIR FIRE STATION VALVE (LEAKS) IN MACHINERY SPACE AND AT PORT SIDE 2ND DECK.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Accommodation/Occupational Safety
Issued 19 September 1990 Resolved
PROVIDE COVERS AND MEANS TO SECURE OVER THE NATURAL VENTILATION OPENINGS ON ENGINEROOM STACK.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Engineering
Issued 19 September 1990 Resolved
PROVIDE SUITABLE OUTBOARD MOTOR FOR RESCUE BOAT WITH COAST GUARD APPROVED HOSES ON FUEL TANK.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Construction/Loadline
Issued 19 September 1990 Resolved
DRYDOCK VESSEL NO LATER THAN 31JAN91 FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Fire Fighting
Issued 30 May 1990 Resolved
SERVICE THE GALLEY DRY CHEMICAL FIXED EXTINGUSHIER.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Engineering
Issued 30 May 1990 Resolved
PROVIDE 30X30 MESH FLAME SCREEN FOR LUBE OIL VENTS (4 TOTAL).
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Lifesaving
Issued 30 May 1990 Resolved
PROVIDE A TOTAL OF 602 ADULT LIFE JACKETS AND 61 CHILD LIFE JACKETS. UNTIL THE REQUIRED NUMBER OF LIFEJACKETS ARE ON BOARD THE NUMBER OF PASSENGERS ISLIMITED TO THE ACTUAL NUMBER OF LIFE JACKETS PROVIDED.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Documentation
Issued 30 May 1990 Resolved
POST EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-5.
Condition: Unknown
Due 30 May 1990
Resolved 30 May 1990
Construction/Loadline
Issued 23 May 1990 Resolved
DRYDOCK VESSEL NO LATER THAN 28SEP90 FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Engineering
Issued 11 May 1990 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF #3 GENERATOR. WHILE PORTABLE GENERATOR IS IN OPERATION, A LIVE WATCH SHALL BE POSTED. TO BE COMPLETED NO LATER THAN 14MAY90.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Construction/Loadline
Issued 11 January 1990 Resolved
REPAIR E/R DOOR TO RUDDER ROOM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Fire Fighting
Issued 11 January 1990 Resolved
PROVE FIRE PUMP IS SELF PRIMING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
REPAIR 2 L/R LIGHTS AFT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
PROVIDE MISSING GLOBES AND GUARDS IN THE E/R.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REPAIR DEAD EMERGENCY LIGHTS IN E/R PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1990 Resolved
BOLT DOWN DECK PLATES, AFT TUNNEL.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
PROVIDE 1 MISSING L/R LIGHT AFT WITH 18' LINE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Fire Fighting
Issued 11 January 1990 Resolved
REPAIR FIRE PUMP GAUGE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Fire Fighting
Issued 11 January 1990 Resolved
REPLACE WASTED FIRE PUMP OVERBOARD LINE WHERE PAD WELDED.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1990 Resolved
ADJUST LATCH GALLEY DOOR TO 01 DECK.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 17 November 1989 Resolved
FREE-UP AND CLOSE THE EMERGENCY ESCAPE SCUTTLE IN THE RUDDER ROOM.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Deck/Cargo
Issued 17 November 1989 Resolved
MAKE PROPERLY OPERABLE THE SELF-CLOSING VALVE FITTED ON THE WASTE OIL TANK.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Engineering
Issued 17 November 1989 Resolved
INSTALL AND PROVE OPERATION OF THE MAIN DIESEL ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Electrical
Issued 17 November 1989 Resolved
PROVIDE PROPER SIZE AND NUMBER OF ELECTRICAL RECEPTACLES AT THE BANDSTAND, SUN DECK BAR, BREEZEWAY, VIDEO GAME ROOM AND CASHIER BOOTH.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Electrical
Issued 17 November 1989 Resolved
PROVIDE CIRCUIT DIRECTORY CARDS FOR CASINO AND NAVIGATING BRIDGE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Electrical
Issued 17 November 1989 Resolved
TIGHTEN CONNECTIONS ON BATTERY SUPPLY AFT OF NAVIGATING BRIDGE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Construction/Loadline
Issued 17 November 1989 Resolved
IN THE RUDDER ROOM, GOUGE AND WELD THE FRACTURE IN THE DECK BETWEEN 1ST AND2ND UNDERDECK LONGITUDINALS, PORT OF CENTERLINE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Construction/Loadline
Issued 17 November 1989 Resolved
PROVIDE AN AUTOMATIC DOOR CLOSURE FOR THE "A" CLASS DOOR IN THE GALLEY TO THE CASINO DECK.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Accommodation/Occupational Safety
Issued 17 November 1989 Resolved
PROVIDE A FIXED MOUNTING BRACKET FOR THE GALLEY WARMING OVEN.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Lifesaving
Issued 17 November 1989 Resolved
RENEW HAND GRAB LINES OF FOUR LIFE FLOATS LOCATED ON THE AFTER CASINO DECK.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Lifesaving
Issued 17 November 1989 Resolved
RENEW 3 RING BUOYS (2 ON BRIDGE DECK AND 1 ON STARBOARD AFT CASINO DECK).
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Lifesaving
Issued 17 November 1989 Resolved
PROVIDE SPACERS FOR TWO (2) AUTOMATIC FLOAT LIGHTS ON BRIDGE DECK INSTALLEDON THE LIFE FLOATS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Lifesaving
Issued 17 November 1989 Resolved
PROVIDE RETROREFLECTIVE TAPE FOR ALL RING LIFE BUOYS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 17 November 1989 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Fire Fighting
Issued 17 November 1989 Resolved
PROVIDE COMPATIBLE FIRE HOSES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Fire Fighting
Issued 17 November 1989 Resolved
PROVIDE ALL PURPOSE NOZZLES (THREE POSITION) FOR THE FIRE HOSES.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Construction/Loadline
Issued 31 May 1989 Resolved
CASINO DECK PORT FWD TONNAGE OPENING VOIDED BY WELDING.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Construction/Loadline
Issued 31 May 1989 Resolved
CASINO AND MAIN DECK AFT TONNAGE OPENINGS VOID BY SEALS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Electrical
Issued 31 May 1989 Resolved
REPAIR EMERGENCY LIGHTS - STAIRS MAIN TO 01 DECK.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Deck/Cargo
Issued 31 May 1989 Resolved
PROVIDE TEE WRENCH - FWD CHAIN LOCKERS AND FOREPEAK ACCESS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Electrical
Issued 31 May 1989 Resolved
CLEAR ALL ELECTRICAL GROUNDS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Construction/Loadline
Issued 31 May 1989 Resolved
CLEAN ALL PAINT OFF OF WATERTIGHT DOOR GASKETS THROUGH-OUT.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Navigation
Issued 31 May 1989 Resolved
REPAIR GALLEY S.P. PHONE.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Accommodation/Occupational Safety
Issued 31 May 1989 Resolved
PROVIDE VENT SHUT-DOWNS FOR TOILETS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Navigation
Issued 31 May 1989 Resolved
REPAIR F/O REACH ROD TEE WRENCHES.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Deck/Cargo
Issued 31 May 1989 Resolved
REMOVE OXY/ACET. EQUIPMENT.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Deck/Cargo
Issued 31 May 1989 Resolved
REBUILD BOAT CRADLE.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Documentation
Issued 1 March 1989 Resolved
CONTROL VERIFICATION EXAMINATION WAS COMPLETED ON 01MAR89. NEXT QUARTERLY EXAM DUE 01JUN89. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS EXAM.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Navigation
Issued 1 March 1989 Resolved
FREE UP FOREPEAK REACH ROD.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Lifesaving
Issued 1 March 1989 Resolved
PROVIDE 27 ADULT PFD'S.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Fire Fighting
Issued 1 March 1989 Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Electrical
Issued 1 March 1989 Resolved
REPAIR DEFECTIVE GAUGE ON BRIDGE PANEL: PORT MDE ENGINE OIL STBD MDE TRANSMISSION OIL
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Lifesaving
Issued 1 March 1989 Resolved
RENEW ALL FLARES BY 31MAR89.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Navigation
Issued 17 March 1987 Resolved
REPLACE MISSING NAV LIGHT RELAY IN NAV LIGHT CONTROL PANEL.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Fire Fighting
Issued 17 March 1987 Resolved
PROVIDE APPROVED PLANS FOR FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Documentation
Issued 17 March 1987 Resolved
UPDATE MARINE DOCUMENT TO REFLECT READ MEASURED TONNAGE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 3 May 1982 Resolved
PROVIDE APPROVED PLANS OF MODIFICATIONS IN #5 AND #6 PORT AND STARBOARD BALLAST TANKS .
Condition: Unknown
Due 3 May 1982
Resolved 3 May 1982
Engineering
Issued 11 February 1982 Resolved
MAKE PERMENANT REPAIRS TO #2 PORT FUEL TANK IN WAY OF CARGO LOADING PORT.
Condition: Unknown
Due 28 February 1982
Resolved 11 February 1982
Construction/Loadline
Issued 11 February 1982 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGE PORT SIDE SHELL AND RUB RAIL IN WAY OF THE CARGO LOADING PORT.
Condition: Unknown
Due 28 February 1982
Resolved 11 February 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.