Inspection record

Last inspected 10 August 2026
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 41 calendar years (1984–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8642440
Flag
UNITED STATES
Maury page id
psix-49858

Documentation record

Registered dimensions (L × B × D)571.3 ft × 105.0 ft × 19.3 ft
Registered tonnagegross 7,856 / net 7,856
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFMC CORP MARINE & RAIL · PORTLAND, OR, UNITED STATES · built 1978
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 8 December 2025 · expires 31 January 2027
Service, as the file records itFreight Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7856 - Regulatory (Subpart C or D), Gross Ton
7856 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 106 inspections, each with its date, unit and type; 126 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DEFENDER Towing Vessel · MISLE 144331 · 20 March 2026 · activity 8340874EXPLORER Towing Vessel · MISLE 133702 · 13 September 2024 · activity 8013807PATRIARCH Towing Vessel · MISLE 146017 · 23 August 2009 · activity 3575294EXPLORER Towing Vessel · MISLE 133702 · 10 November 1998 · activity 168067BORIQUEN Passenger Barge (Inspected) · MISLE 45834 · 14 November 1993 · activity 73950

Inspection history · 106

10 August 2026 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8460959
30 June 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8420862
17 June 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8407130
29 April 2026 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8358211
20 March 2026 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8340874
2 March 2026 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8318449
4 February 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8306804
7 January 2026 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8287742
17 December 2025 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8282475
8 October 2025 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8246925
27 August 2025 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8218998
9 April 2025 Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8108583
26 March 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8100143
13 September 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8013807
30 April 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7903935
1 December 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7833873
21 November 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833063
1 November 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7818582
1 February 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7619123
30 January 2023 Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7628914
3 February 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7390248
8 April 2021 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7171045
17 March 2021 Security Breach · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7157773
21 May 2020 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6957290
10 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6924752
14 March 2019 MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6638054
1 February 2018 MTSA Verification · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6335663
3 May 2017 MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6137803
4 April 2016 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5846552
10 July 2015 Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5179845
1 May 2015 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5117229
29 September 2014 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4994554
8 August 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4952218
8 January 2014 DAPI Audit · Annual Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4793383
28 August 2013 MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4699242
14 June 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4344548
7 May 2012 MARPOL Annex I Examination · Deficiency Check · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4304634
24 September 2010 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3829119
10 September 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3847011
14 July 2010 Internal Structural Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3795555
12 May 2010 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3735830
22 April 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3721926
23 August 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3575294
26 February 2009 MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3424215
21 December 2007 Examination of Repairs · Hull Examination · Internal Structural Exam · MARPOL Annex I Examination · Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3119471
28 September 2007 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3068024
27 September 2006 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2791741
26 August 2005 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2486939
6 July 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2417307
21 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397460
27 May 2005 MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2369714
14 January 2005 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2274919
6 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2003596
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978211
18 September 2003 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1907766
20 February 2003 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1746814
6 January 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1725019
21 June 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1636042
29 June 2001 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1405224
15 December 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1468177
9 August 2000 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1361641
24 August 1999 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1460332
10 November 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 168067
30 October 1998 Examination of Repairs · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406393
6 February 1998 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 820915
6 February 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1400719
18 November 1997 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1413276
16 October 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392807
17 December 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097250
18 November 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1367992
30 April 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 658697
29 April 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 146324
8 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 201039
8 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757693
12 October 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1079345
24 October 1994 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 863764
5 April 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 510933
10 December 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 849141
24 November 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 848126
14 November 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 73950
26 August 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 831384
11 January 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1138257
18 December 1992 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1141305
1 December 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 829917
18 July 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1253111
13 June 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 947515
4 March 1992 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 961794
21 November 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 938156
27 December 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1236493
26 January 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222688
9 January 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 902280
13 December 1989 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1242178
22 September 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001536
29 September 1988 Examination of Repairs · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1196450
29 April 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1346151
9 March 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1028909
4 November 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1328464
20 May 1987 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1310464
13 February 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1013674
5 December 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332191
2 October 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319514
11 October 1985 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1300824
16 July 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 979821
14 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283863
8 February 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1285827
19 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283762

Deficiency record · 126

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 March 2019 Resolved
Replace both gaskets on hatches leading to second deck from weather deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 2 April 2019
Resolution: Company installed new gaskets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2019 Resolved
Containers carrying any quantity of hazardous material must be placarded. Replace Class 3 flammable liquids placard on aft side of fuel tank
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 2 April 2019
Resolution: Company applied placarding.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2019 Resolved
The installation of all systems of an electrical engineering shall be in accordance with the requirements of subchapter J. Secondary generator (stbd) was inoperable at time of inspection. Demonstrate operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 2 April 2019
Resolution: Witnessed running of generator and test of over speed device.
Construction/Loadline › Hull › Bracket
Issued 10 July 2015 Resolved
#3 Void P/W Fr17- A&W Corner Gusset
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 26 August 2015
Resolution: Received e-mail from POC with satisfactory picture of repairs.
Construction/Loadline › Hull › Bracket
Issued 10 July 2015 Resolved
#3 Void S/W Fr 21- Repair web frame Fracture
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 26 August 2015
Resolution: Received e-mail from POC with satisfactory picture of repairs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 July 2015 Resolved
#3 Void S/W Fr20- Longitudnal BLKHD C&R brace angle
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 9 May 2017
Construction/Loadline › Hull › Transverse Frame
Issued 10 July 2015 Resolved
#3 Void S/W Fr22- Crop and Repair Transverse frame and Deep web to bilge (2 inserts)
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 26 August 2015
Resolution: Received e-mail from POC with satisfactory picture of repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 10 July 2015 Resolved
#5 Void S/W Fr31- Crop and insert transverse frame at vertical side shell stiffener connection due to fracture of previous weld repair.
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 26 August 2015
Resolution: Received e-mail from POC with satisfactory picture of repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 10 July 2015 Resolved
#5 Void P/W Fr32- Crop and insert transverse frame to side shell vertical frame connection due to fracture of previous weld repair.
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 9 May 2017
Construction/Loadline › Hull › Stiffener
Issued 10 July 2015 Resolved
#5 Void P/W Fr32- Crop and insert vertical deep web side shell stiffener between longitudinal side shell stiffeners 4 & 5 from overhead.
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 9 May 2017
Construction/Loadline › Hull › Weld
Issued 10 July 2015 Resolved
#6 Void P/C Fr40-41- Clean and Reweld Wore Weld seam
Action required: 705 - Other - as specified
Due 13 September 2015
Resolved 26 August 2015
Resolution: Received e-mail from POC with satisfactory picture of repairs.
Construction/Loadline › Structures › Superstructure
Issued 4 February 2014 Resolved
Make proper repairs to the following 2nd deck diagonal stations; (1) Frame 34, (2) Frame 28, (3) Frame 50 as identified by the USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 25 September 2014
Resolution: Wittness repairs
Construction/Loadline › Structures › Deck Plating
Issued 4 February 2014 Resolved
Provide proper insert IWO holed/wasted deck plating on 3rd deck, Frame 56, Lane I-J.
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 25 September 2014
Resolution: witness repairs
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 June 2012 Resolved
Repair/replace wasted railing on aft 3rd deck.
Due 14 July 2012
Resolved 18 February 2013
Resolution: Verified proper repair of wasted railing on 3rd deck.
Construction/Loadline › Hull › Stiffener
Issued 8 May 2012 Resolved
C/R FBS, main deck, fm 41 stbd side @ #6 side long.
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Structures › Deck Plating
Issued 8 May 2012 Resolved
Insert dk approx 4' x 8' (to good metal) main dk, fm 37, lane J *Temp repairs must be made prior to carriage of cargo.
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Structures › Superstructure
Issued 8 May 2012 Resolved
2nd Dk, insert damaged, damaged vert stanchions @ fm 58 between B/C & D/E (2).
Due 8 July 2012
Resolved 14 June 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 May 2012 Resolved
Renew wasted railing on fwd ladder between 2-3 dks and 3rd dk aft portside railing (crack)
Due 8 July 2012
Resolved 14 June 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 May 2012 Resolved
3rd dk stbd side railing, repair 6 vert stanchions.
Due 8 July 2012
Resolved 8 May 2012
Construction/Loadline › Hull › Side Shell
Issued 8 May 2012 Resolved
Repair cracks in side shell, port side main dk @ fm 37, 36, 34, 33, 30 and @ fm 33 on 2nd dk.
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Hull › Side Shell
Issued 8 May 2012 Resolved
Repair wasted sideshell on main dk, port side @ fm 42, 41, 38, and 2nd dk port side catwalk @ fm 35.
Action required: 705 - Other - as specified
Due 18 February 2013
Resolved 29 June 2012
Resolution: sited repair
Construction/Loadline › Hull › Side Shell
Issued 8 May 2012 Resolved
2nd dk, renew wasted area under port WTD.
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Hull › Side Shell
Issued 8 May 2012 Resolved
2nd dk, repair cracks, port side catwalk, fm 35
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 May 2012 Resolved
2nd dk, C/R wasted under dk longs fm 36 (port) #'s 1,3, and 4.
Due 8 July 2012
Resolved 29 June 2012
Resolution: sited repair
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2012 Resolved
3rd dk C/R wasted bracket for port side dk light (#2 from the bow).
Due 8 July 2012
Resolved 14 June 2012
Construction/Loadline › Hull › Transverse Frame
Issued 10 September 2010 Resolved
#1 Stbd wing Frame #5 IVO #4 bracket, crop out and insert 18" X 18" bulkhead. Provide repair proposal prior to commencing work. Complete repairs to satisfaction of attending marine inspector within 30 days.
Action required: 705 - Other - as specified
Due 10 October 2010
Resolved 25 September 2010
Resolution: Operator cropped and renewed damage area with a welded steel insert of 23"x21"x0.375" for the bulkhead and a 12"X12"x 0.5" triangular plate for the bracket. ABS attested to the repair.
Construction/Loadline › Structures › Scuttle
Issued 10 September 2010 Resolved
Cropout and renew #6 Port scuttle. Complete to satisfaction of attending marine inspector within 30 days.
Action required: 705 - Other - as specified
Due 10 October 2010
Resolved 25 September 2010
Resolution: The #6 Port scuttle was cropped and replaced with a welded scuttle of the with the same type hatch assembly as the original.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1, Port Center, Fr 9, transverse frame insert along longitudinal bulkhead 3’x4’
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1, Port Center, Fr 7 Overhead frame insert
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Attended vessel to inspect welds on Item #3 (#1 Port Center Ballast tank, frame #7 overhead frame insert). Welder was GMIS welder [name withheld] ( ABS weld cert included in case file), weld inspected SAT. Cleared item #3 835.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1, Port Center, Fr 8 possible overhead frame insert
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair satisfactory.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1 Stbd Center, Fr 7 transverse frame insert approximately 2’ long next to longitudinal bulkhead
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1 Stbd Center, Fr 8 possible overhead frame insert
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1 Stbd Wing, Fr 7 fractured at #4 side long arc and weld
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#1 Stbd Wing, Fr 5 crop and renew side bracket #4
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#2 Port Wing, Fr 13.5 fractured side long #14 arc and weld
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#3 Port Wing, Fr 22 deep web frame to #6 side long fractured in two places arc and weld
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#3 Port Wing, Fr 20 deep web frame insert from side long #1 to side long #3
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#3 Stbd Wing, Fr 20 -21 grind side shell and gauge for possible insert
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Looked at area. Original scantlings according to Port Engineer is 1" for hull.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#3 Stbd Wing, Fr 20 fracture at #2 side long arc and weld
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#3 Stbd Wing, Fr 20-21 crop and renew 2’ of #3 side long
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspected repair all sat.
Construction/Loadline › Hull › Weld
Issued 16 July 2010 Resolved
#6 Port Wing, Crop and renew #4,#6, and #8 ladder rungs
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 10 September 2010
Resolution: Inspectors looked at ladder. Identified that the Stbd. ladder was replaced and nothing wrong with port ladder. Port engineer claimed that ladder was completely replaced vice repairing three rungs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 April 2010 Resolved
Properly seal all electrical fittings and fixtures.
Action required: 705 - Other - as specified
Due 6 June 2010
Resolved 12 May 2010
Resolution: NUMEROUS ELECTRICAL CONNECTION AND JUNCTION BOXES PROPERLY SEALED.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 22 April 2010 Resolved
Replace tachometer on inboard genset.
Action required: 705 - Other - as specified
Due 6 June 2010
Resolved 12 May 2010
Resolution: NEW TACH INSTALLED AND TESTED SAT.
Construction/Loadline › Hull › Stiffener
Issued 27 February 2009 Resolved
Make repairs to the top of the stanchions at FR 35 lane f&g, FR 37 lane d&e, FR 49 lane f&g and FR 59 lane a
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Fractures were gouged and welded
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 February 2009 Resolved
Repair the ground detection lights for L-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2009
Resolved 12 March 2009
Resolution: Detection lights are working.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2009 Resolved
Repair lights throughout the vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Lights were working.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2009 Resolved
Top deck, renew the bracket for the port aft light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Bracket was replaced
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2009 Resolved
On the 2nd deck, repair the broken light fixture on the port side IWO the windows.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Fixture replaced.
Construction/Loadline › Hull › Stiffener
Issued 27 February 2009 Resolved
Repair the 3rd stanchion from the stern between lanes h&i on the 2nd deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: The stanchion was repaired
Construction/Loadline › Hull › Stiffener
Issued 27 February 2009 Resolved
Renew the 1st stanchion inboard on the port side aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 19 March 2009
Resolution: The stanchion was renewed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 February 2009 Resolved
Properly label the breaker panel and breakers on the stbd side accommodation on the 2nd deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Panel and breakers are labeled
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 February 2009 Resolved
Repair the cable way as needed above the generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: The cable way supports were replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2009 Resolved
Repair lights IWO the main stairwell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 19 March 2009
Resolution: Light are working.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 27 February 2009 Resolved
Clean up oil on the main deck in lane E, aft of the fuel tank and under the generator.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Oil is cleaned up
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 February 2009 Resolved
Make repairs to the breaker panel on the main deck door latch. Install missing blanks in panel P-3 and properly support the main cable to the 450V panels
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Latch repaired, blanks installed and hangers installed
Construction/Loadline › Structures › Superstructure
Issued 27 February 2009 Resolved
Crop and renew all bad rails and supports on the look out tower
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Rails and supports were repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 February 2009 Resolved
Crop and repair the rail on the stbd side of the top deck by stand #7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: The rail is repaired
Engineering › Diesel Engine (auxiliary) › Valve
Issued 27 February 2009 Resolved
Label remote fuel valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 12 March 2009
Resolution: Valve are labeled
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 September 2006 Resolved
2nd Deck starboard side forward ground fault detection panel shows ground or may have inop light bulbs, troubleshoot and repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Removed ground fault panel, circuit for this panel no longer in use.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 September 2006 Resolved
Properly secure all electrical bulkhead penetrations throughout the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 28 September 2006
Resolution: Installed new kick pipes at electrial penetrations.
Construction/Loadline › Structures › Door
Issued 27 September 2006 Resolved
2nd deck port and starboard weather tight doors do not seal, make nessacary repairs to make both doors weather tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 28 September 2006
Resolution: Welded up knife edge and ground back to size on both doors.
Construction/Loadline › Structures › End Bulkhead
Issued 27 September 2006 Resolved
Step and Bulkhead under the port weather tight door on 2nd deck are wasted, crop and renew back to good metal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2006
Resolution: Renewed metal and step under weather tight door.
Construction/Loadline › Hull › Hull Plating
Issued 27 September 2006 Resolved
Deck plate on upper deck starboard side forward, (on forward overhang), is wasted. Crop and Renew approximately 3 foot by 4 foot area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2006
Resolution: Wasted area 3ft X 4ft was renewed. Visual inspection of welds. Sat
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2006 Resolved
Crop and Renew wasted 4th overhead longitudinal inboard and repair fracture of 3rd inboard long at frame 31 starboard side, second deck.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2006
Resolution: Replaced both longitudinals back to good metal.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2006 Resolved
Fractured weld on 6th longitudinal inboard on overhead at frame 35 starboard side, second deck.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2006
Resolution: Rewelded frame. Sat.
Construction/Loadline › Hull › Bracket
Issued 27 September 2006 Resolved
Crop and Renew wasted angle bracket between 2nd longitudinal from deck at frame 36 starboard side main deck.
Condition: Improper/Lack of Maintenance
Due 27 October 2006
Resolved 28 September 2006
Resolution: Bracket was renewed. Sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2006 Resolved
Crop and Renew wasted bottom longitudinal at frame 37 starboard side main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 28 September 2006
Resolution: Renewed longitudinal. Sat.
Construction/Loadline › Hull › Side Shell
Issued 27 September 2006 Resolved
Repair holes in sideshell at frames 46 and 52 on starboard side just above main deck. To be completed at next availability, providing wasted metal does not deteriorate beyond present condition. And in no case later than 03 Feb 08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2008
Resolved 9 May 2017
Resolution: Repaired in shipyard.
Construction/Loadline › Structures › Manhole
Issued 27 September 2006 Resolved
Crop and Renew wasted ladder combing around ladder deck opening at frame 52 on second deck starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Cropped and renewed combing, all sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2006 Resolved
Crop and Renew bottom side longitudinal between frames 41 and 42 port side main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 28 September 2006
Resolution: Renewed longitudinal. Sat.
Construction/Loadline › Hull › Transverse Frame
Issued 27 September 2006 Resolved
Reweld loose flatbar shelf on aft upper deck overhang centerline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Removed flatbar not a structural member.
Engineering › Lubricating Oil Service System › Hose
Issued 27 September 2006 Resolved
Oil supply line on port (inboard) Generator leaking excessively. Repair oil leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Repaired oil leak, all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 September 2006 Resolved
Provide exhaust insulation for both SSDG manifolds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Installed new exhaust lagging on both ssdg''s as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2005 Resolved
Properly remove dead end wiring on Pt side Fwd outside main deck.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 23 September 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 26 August 2005 Resolved
Properly repair the 2nd deck fwd stbd bow and 3rd deck stbd side 3rd and 7th from fwd light brackets.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 23 September 2005
Construction/Loadline › Structures › Superstructure
Issued 26 August 2005 Resolved
Inspect and repair the intermediate rail on the 3rd deck.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 23 September 2005
Construction/Loadline › Structures › Superstructure
Issued 26 August 2005 Resolved
Check for a hole and properly repair if needed on the Facial plate on the 3rd deck pt side below the 4th light.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 23 September 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 14 January 2005 Resolved
Properly repair the broken cable run support bracketsalong the portside main deck between frames 42 & 41
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 2 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 14 January 2005 Resolved
Properly replace the two missing deck lights and properly secure one junction box along top deck stbd side.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 2 February 2005
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 January 2005 Resolved
Properly repair the drip tray and install electrical matting for the electrical panel on 2nd deck stbd side fwd or permanetly secure the power going to the box. Vessel rep staed that the box is no longer in use.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 2 February 2005
Resolution: Vesssel repaired the drip tray and placed matting below the box.
Construction/Loadline
Issued 18 November 1997 Resolved
Noted 20 areas of distorted framing in stern void requiring crop and renew_x001C_Noted 1 area of temp repair to bottom plate in #5 void requiring crop and renew_x001C_ Noted 2 areas of fractured trnsvrs framing requiring crop and insert
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Unknown
Issued 18 November 1997 Resolved
Make #6,7,and 8 ballast tanks available for inspection.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
Noted 14 areas of fractured or unfinished tie-in framing welds requiring _x001C_ gouge and reweld_x001C_ Noted 2 areas of fractures to sw blkhd access opening to ajoining void _x001C_ requiring gouge and reweld
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
Noted 15 areas of sideshell plate set-ins requiring crop and insert plate and frames_x001C_ Noted 19 areas of vert sideshell frame set-ins requiring crop and insert_x001C_ Noted 4 areas of w/t blkhd set-ins requiring crop and insert
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Construction/Loadline
Issued 18 November 1997 Resolved
Renew #6S ballast tank hatch cover_x001C_ Renew #8P ballast tank hatch and cover_x001C_ Renew #9P void hatch cover
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Lifesaving
Issued 18 November 1997 Resolved
Replace both ladders to #9 void
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Electrical
Issued 18 November 1996 Resolved
First deck - Repair 2 electrical outlet boxes stbd side_x001C_ Repair 1 electrical outlet box port side
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Electrical
Issued 18 November 1996 Resolved
Second deck - Resupport overhead electrical wiring fwd port and stbd side (approx 6 feet each). Wiring is nav light feeder circuits.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Electrical
Issued 18 November 1996 Resolved
Second box - Make permanent repairs to service box (drip guard, face plate)
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Construction/Loadline
Issued 18 November 1996 Resolved
First deck - Crop out and renew 4 horizontal stiffners located between frames 49 and 50
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Construction/Loadline
Issued 18 November 1996 Resolved
Third deck - Crop out and renew all corroded hand railing located on portside (approx 200 feet)
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Lifesaving
Issued 12 October 1995 Resolved
MAKE PERMANENT REPAIR TO PVC DECK DRAIN, STBD, FWD MAIN DECK.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
REPAIR OVERHEAD LT OR REMOVE CABLE RUN, AFT LANE "G".
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
REMOVE OR REPAIR OVERHEAD LIGHTING IN COMPARTMENTS OF SECOND DECK FWD.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Construction/Loadline
Issued 12 October 1995 Resolved
MAKE "WATERTIGHT" THE DOORS ON SECOND DECK FWD.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON #1 GENERATOR.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
SUBMIT PROPOSAL FOR REPAIR OF SHORTIE CABLE.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
REMOUNT ELECTRICAL OUTLET, FR35, 2ND, DECK PORT.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
REPLACE ELECTRICAL CABLES FM MOTOR STARTER TO #2 BALLAST PUMP.
Condition: Unknown
Due 12 October 1995
Resolved 30 November 1995
Electrical
Issued 12 October 1995 Resolved
REMOUNT OVERHEAD LIGHTING STBD SIDE FWD._x001C_
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 24 November 1993 Resolved
NO 2 GENERATOR (OUTBOARD GENERATOR) INOPERABLE.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Construction/Loadline
Issued 13 June 1992 Resolved
COMPLETE REPAIRS TO THE STRUCTURAL MODIFICATION IN THE NUMBER ONE VOID.
Condition: Unknown
Due 13 June 1992
Resolved 13 June 1992
Construction/Loadline
Issued 13 June 1992 Resolved
MAKE PERMENANT REPAIRS TO THE UPSET SECTIONS OF THE CENTER VERTICAL BULKHEAD IN THE NUMBER 2 AND 3 VOIDS.
Condition: Unknown
Due 13 June 1992
Resolved 13 June 1992
Construction/Loadline
Issued 13 June 1992 Resolved
MAKLE PERMENANT REPAIRS TO THE BENT SIDE SHELL FRAME, PORT SIDE IN THE NUMBER 9 VOID.
Condition: Unknown
Due 13 June 1992
Resolved 13 June 1992
Construction/Loadline
Issued 13 December 1989 Resolved
MAKE PERMANENT REPAIRS TO 4TH FRAME FROM FWD. BULKHEAD AT 1ST & 2ND LONGI- TUDINAL FROM TOP, STBD. SIDE IN NO. 9 VOID.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Electrical
Issued 13 December 1989 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIP ON THE INBOARD SERVICE GENERA-TOR.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Construction/Loadline
Issued 13 December 1989 Resolved
CROP AND RENEW 1 THROUGH 3 SIDE LONGITUDINALS FROM TOP AT FWD. BULKHEAD PORT SIDE IN NO. 8 BALLAST TANK.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Construction/Loadline
Issued 13 December 1989 Resolved
MAKE PERMANENT REPAIRS TO NO. 5 FRAME AT 4TH LONGITUDINAL STBD. SIDE IN NO.1 VOID.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Electrical
Issued 13 December 1989 Resolved
PROVE PROPER OPERATION AND TEST OVERSPEED TRIP ON OUTBOARD SERVICE GENERA- TOR AFTER RADIATOR IS REPLACED.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Construction/Loadline
Issued 9 March 1988 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AFTER STBD. CORNER PLATE AND DAMAGED INTERNALS.
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988
Construction/Loadline
Issued 20 May 1987 Resolved
NO. 1 VOID PORT SIDE -VEE AND WELD FRACTURES IN THE FOLLOWING LOCATIONS OUTBOARD SIDE FRAMES 5 THRU 11 AS MARKED, NO. 7 BOTTOM TRANSVERSE FRAME AT THE LONGITUDNAL BULKHEAD CONNECTION.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Electrical
Issued 2 October 1986 Resolved
MAKE PERMANENT REPAIRS TO THE WIRING CLAMPS ON THE STBD SIDE MAIN DECK.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Electrical
Issued 2 October 1986 Resolved
MAKE PERMANENT REPAIRS TO THE ELECTRIC LIGHTS ON THE STBD SIDE OF THE 3RD DECK.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Construction/Loadline
Issued 8 February 1985 Resolved
NO. 4 PORT VOID. CROP AND INSERT DECK AND SIDE SHELL BETWEEN FRAMES NO. 26 AND 27 AND RENEW ASSOCIATED INTERNALS IN WAY OF.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
#3 STBD VOID TANK. CROP AND INSERT DAMAGE IN WAY OF FRAME NO. 5 BETWEEN 1ST AND 3RD SIDE SHELL LONGS
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
#3 PORT VOID TANK, AT FWD. BLK.HD. CROP AND RENEW NO. 2 CORNER BRACKET AND ATTACHED. SECTION OF SIDE SHELL LONG. CROP AND RENEW INSERT AT 1ST HALF FRAME AT BOTTOM SIDE LONG. CROP AND INSERT FRS. 1 AND 2 BETWEEN SIDE SHELL LONGS NO. 1 AND 4 AND ASSO. DK. BKT. CROP AND INSERT FRAME NO. 5 BETWEEN 1
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
CROP AND INSERT 5TH FRAME BETWEEN DECK AND NO. 2 SIDE SHELL LONG.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
#8 STBD BALLAST TANK. CROP AND RENEW #2 SIDE SHELL CORNER BRACKET AT FWD BKD. FAIR IN AND WELD #2 SIDE LONG.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Construction/Loadline
Issued 8 February 1985 Resolved
PORT VOID TANK, CHOP AND RENEW APPROXIMATELY 8 FEET OF UPPER FRAMES #3 AND #4 AT SIDE SHELLS.
Condition: Unknown
Due 8 February 1985
Resolved 8 February 1985
Electrical
Issued 19 October 1984 Resolved
PROVIDE SECURING DEVICES FOR THE BARGES MAIN POWER LINE ON THE PORT SIDE INWAY OF THE WASTED DEVICES.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Electrical
Issued 19 October 1984 Resolved
PROVIDE A BLANK FOR THE 450 VOLT CIRCUIT PANEL LABELED P3 NEAR THE PORT BOWGENERATORS.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Construction/Loadline
Issued 19 October 1984 Resolved
PROVIDE SECURING COVERS FOR ALL FOUR BALLAST TANK GOOSENECK VENTS LOCATED IN WAY OF #6, #7 AND #8 PORT AND STARBOARD BALLAST TANKS.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Accommodation/Occupational Safety
Issued 19 October 1984 Resolved
RENEW ONE (1) SECTION OF HAND RAIL ON THE STARBOARD SIDE TWO (2) SECTIONS FORWARD OF THE LIGHT LABELED S4.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Electrical
Issued 19 October 1984 Resolved
SECURE THE DECK LIGHTING POWER BOXES ON THE THIRD (3RD) DECK IN WAY OF THE FOLLOWING LIGHTS: S8, S11, S12, S13 AND P4, P8, P9, P11, P12, P13, P14.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Construction/Loadline
Issued 19 October 1984 Resolved
WELD THE FOLLOWING FRACTURES ON THE THIRD DECK IN WAY OF THE LONGITUDINAL CURBING: 3RD LANE FROM STBD (2 FRACTURES); 5TH LANE FROM STBD (2 FRAC- TURES); 7TH LANE FROM STBD (2 FRACTURES); 9TH LANE FROM STBD (3 FRACTURES);10TH LANE FROM STBD (1 FRACTURE).
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Electrical
Issued 19 October 1984 Resolved
RENEW THE ELECTRICAL OUTLET ON THE FIRST (1ST) DECK STARBOARD SIDE IN WAY OF FRAME 35.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984