MAURY USCG vessel records Sign in
← All vessels

RESOLVE PIONEER

RESOLVE PIONEER is a 1978 industrial vessel. The Coast Guard has recorded 139 inspections since 1983, most recently in March 2026, along with 127 deficiencies and 9 casualty investigations between 2002 and 2023.

Records from 1983 to 2026. Most recent: inspection, 17 March 2026.

Built
1978
Last inspected
17 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7528843 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD8846
Flag
UNITED STATES
367303490
Maury page id
psix-49860

Inspections, by type

…with no type recorded39
Years with a record 40 calendar years (1983–2026)
The 139 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
1058 - Convention (Subpart B), Gross Ton
203 - Regulatory (Subpart C or D), Net Ton
317 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD8846MMSI 367303490 · active · compulsorily equipped · granted 27 June 2017, expires 18 July 2027
WDB7554MMSI 369387000 · cancelled · compulsorily equipped · granted 30 April 2004, cancelled 31 May 2007
WCF5743MMSI not assigned · cancelled · compulsorily equipped · granted 3 May 1994, cancelled 6 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BARGE 141 Oil Recovery · MISLE 43405 · 18 September 2003 · activity 1932495BARGE 141 Oil Recovery · MISLE 43405 · 17 October 2002 · activity 1693623

Inspection history · 139

17 March 2026 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8327749
28 May 2024 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7924213
28 March 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7886122
24 February 2024 Examination of Repairs
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7869592
25 September 2023 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7798228
9 September 2023 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7788683
20 June 2023 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7719487
4 May 2023 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7711446
3 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7662184
20 February 2023 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7711414
10 January 2023 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7620896
9 January 2023 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7633272
9 August 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7529371
22 February 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7400303
25 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7385696
3 November 2021 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7344702
20 June 2021 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7261648
4 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7206621
8 March 2021 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7152528
22 February 2021 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7124809
31 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7039403
22 June 2020 Internal Structural Exam · Deficiency Check · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6974370
11 May 2020 DAPI Audit · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6951441
10 March 2020 Administrative Inspection · Drydock Extension
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6926375
27 February 2020 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6917284
15 November 2019 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6856073
17 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6716970
13 May 2019 MTSA Verification · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6681371
25 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6491322
23 May 2018 Damage Survey
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6421886
23 May 2018 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6563420
14 May 2018 MTSA/ISPS Verification · DAPI Audit · Periodic Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6414538
17 April 2018 Examination of Repairs
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6400629
13 April 2018 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6395188
22 December 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6327797
15 December 2017 Damage Survey
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6327261
10 December 2017 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6321877
6 December 2017 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6334465
25 July 2017 Drydock Exam · Simplified Stability Test · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6219899
3 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6220561
18 May 2017 MTSA Verification · DAPI Audit · Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6149740
18 July 2016 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5948735
12 February 2016 COI Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5816403
25 November 2015 Industry Initiated Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5769559
25 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5788152
25 July 2012 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4390421
13 June 2012 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4343004
9 February 2012 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4242355
28 September 2011 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4395414
7 December 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3910677
22 November 2010 MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3896610
29 October 2010 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3880505
18 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3698035
3 December 2009 Annual Inspection · DAPI Audit · MTSA Verification · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3641708
9 February 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3424279
29 December 2008 Annual Inspection · MTSA Verification · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3384071
30 August 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3312847
28 April 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3194264
26 February 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3154061
6 December 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3110592
29 October 2007 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3090027
14 June 2007 COI Inspection · Examination of Repairs · Deficiency Check · MTSA/ISPS Verification · Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2961760
9 June 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2385106
8 April 2005 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2336334
2 February 2004 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2013276
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976375
21 November 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1952236
18 September 2003 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1932495
22 August 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1884109
4 March 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1752722
24 February 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1749028
20 February 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804910
1 January 2003 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1859876
4 November 2002 Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1701305
17 October 2002 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1693623
31 October 2001 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 772263
11 October 2001 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 67817
11 October 2001 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 224334
4 May 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1451546
5 April 2000 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 816429
21 December 1999 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1462042
14 December 1999 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 812357
1 December 1998 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 806514
27 June 1998 Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1127130
7 April 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1449053
2 March 1998 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 57416
20 January 1997 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 778294
17 January 1997 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1357854
14 January 1997 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1096398
4 December 1996 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1188982
20 August 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1087518
2 July 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1084529
28 March 1996 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1080021
1 March 1996 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 884947
29 February 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 27674
28 February 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1094
8 February 1996 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 876555
22 December 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357447
19 December 1995 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 883765
14 August 1995 Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1182412
20 December 1994 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1159079
7 December 1994 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1172230
9 July 1994 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 439569
21 April 1994 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 165961
21 April 1994 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 859185
23 February 1994 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 851730
30 November 1993 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 459504
23 February 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 661602
17 February 1993 Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 835742
1 February 1993 Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1422201
12 December 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 165667
9 December 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 186922
8 December 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 113317
7 December 1992 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 827632
14 September 1992 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1245277
31 March 1992 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1266551
12 February 1992 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 683311
31 January 1992 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1007244
14 January 1992 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 81365
5 December 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 661601
5 December 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1005887
2 December 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 661600
27 November 1991 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 944147
10 October 1991 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1247999
3 October 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 938839
22 August 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 945560
29 July 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001236
18 July 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 939728
15 July 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937374
4 November 1990 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230292
23 March 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909183
25 October 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1003037
9 December 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1037667
25 October 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023795
30 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021291
30 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015122
24 September 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990179
21 June 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 973691
21 December 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279433

Deficiency record · 127

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 March 2024 Resolved
Each Class 1 door on a vessel in ocean service must be designed to withstand a head of water equivalent to the depth from the sill of the door to the margin line but in no case less than 10 feet. Three of the four QAWTDs onboard vessel were out of adjustment and did not securely close. Adjust doors to ensure all doors completely and securely close.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 3 April 2024
Resolution: Verified subject QAWTDs were adjusted and closing properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Two junction boxes in the bow thruster room did not close securely and personnel were exposed to energized parts. Secure junction boxes securely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 3 April 2024
Resolution: Ensured junction boxes were closing properly and no longer presenting electrical hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024 Resolved
Electric installations on vessels must ensure:Protection of passengers, crew, other persons, and the vessel from electrical hazards. Several wiring cables were pulled from junction box through stuffing tubes in bow thruster room. Ensure all electrical cables are properly inserted in stuffing tubes and tightened to keep in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Verified wiring cables were properly inserted in stuffing tubes and tightened to keep in place and no longer presenting electrical hazards.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 March 2024 Resolved
Entries shall be made in the Oil Record Book on each occasion, on a tank to tank basis if appropriate, whenever any of the following machinery space operations take place on any ship to which this section applies—) Disposal of oil residue. Improper entry in Oil Record Book regarding discharge of oil. Correct entry and provide supplementry training to all individuals who make ORB entries on proper ORB entries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 April 2024
Resolution: Verified crew/company took appropriate corrective actions including: documenting non-conformance thru company and conducted training with crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 February 2024 Resolved
The respective piping systems installed on ships shall be constructed for the safe and efficient operation of the vessel. A hole in the keel cooler vent piping prevented adequate cooling water to the number two generator, causing the generator to be secured. The section of piping shall be removed, and replaced with satisfactory piping materials, and verified by the attending Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2024
Resolved 24 February 2024
Resolution: Verified completion of repairs
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 November 2023 Resolved
"Systems of the type indicated in § 95.15–5(d), other than systems for tanks, which are of more than 300 pounds of carbon dioxide, shall be fitted with an approved delayed discharge so arranged that the alarm will be sounded for at least 20 seconds before the carbon dioxide is released into the space." During the vessels annual exam in May 2023, the time delay for the fixed fire suppression system failed the above requirements. A certified fire technician shall successful complete the time delay testing, in the presence of a CG Marine Inspector. If during impending testing, the time delays fail, this CG-835 will be changed to a Code 17, and the vessel will not be allowed to operate until the testing is completed successfully.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2023
Resolved 31 January 2024
Resolution: Certified fire suppression company was able to successfully conduct the time delay within the -0/+20% allowance of the rated time delay period.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2023 Resolved
At least two lifebuoys, each with self-activating smoke signals, must be stowed where they can be quickly released from the navigating bridge and should, when released, fall directly into the water without striking any part of the vessel; lifebuoys on vessel's bridge wings were not bridge buoys (insufficient weight) and would not fall directly into the water, as no release mechanism is provided (lifebuoy and smoke signal require movement from side of pilothouse). Vessel must provide bridge buoys and sufficient stowage to meet regulation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 31 May 2023
Resolution: One quick-release device was fabricated, installed, and tested to the satisfaction of the CG. The vessel is presently fabricating another of the same design to fully rectify the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 April 2023 Resolved
Each fire pump must be capable of delivering water simultaneously from the two highest outlest at 50 psi; vessel's pump provided 46-48 psi; must provide the minimum pressure of 50 psi as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Witnessed operational test with 64psi provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 April 2023 Resolved
Each power ventilation system must have the circuit breakers for ventilation grouped on the main switchboard and marked, "IN CASE OF FIRE TRIP TO STOP VENTILATION." Vessel's switchboard was not marked as such.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Labeling provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
Main propulsion machinery must be provided with automatic shut-off controls in accordance with 46 CFR Part 62; vessel's starboard main engine low lube oil shut-off did not automatically shut down the engine; must provide shut-offs as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Witnessed satisfactory s/o of starboard main.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2023 Resolved
Periodic testing of vital systems' procedures must no simulate monitored system conditions by mis-adjustment, artificial signals, improper wiring, tampering, or revision of the system unless the test would damage equipment or endanger personnel; PSTP for jacketwater not practicable; vessel must re-evaluate the procedure and re-submit revision for approval in accordance with 46 CFR 61.40-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 31 May 2023
Resolution: C/E provided a receipt as proof of purchase of the dry block temperature tester. He is to call the office upon delivery of the item.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2023 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40; vessel could not provide evidence of company-run testing nor consortium enrollment. Must provide evidence of such.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Obtained documentation to satisfaction of MI.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 February 2022 Resolved
Each vessel msut have an amplifier-type announcing system that will supplement the general alarm system; vessel does not have a functional public address system (PA system) onboard. Must provide a satisfactory PA system to meet inspection subchapter requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 6 April 2022
Resolution: PA system intalled onboard and satisfactorily tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2022 Resolved
Each lifebuoy must be approved under 46 CFR 160.150; three lifebuoys were outfitted with silicone instead of approved plugs. Must provide means for buoys to be IAW 46 CFR 160.150.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 6 April 2022
Resolution: New liferings provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 February 2022 Resolved
Each generator prime mover mst be outfitted with an overspeed device IAW regulation; #2 generator overspeed inoperatble then starter inoperable. Must show satisfactory test to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2022
Resolved 23 February 2022
Resolution: Generator #2 tested satisfactorily in presence of attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 May 2021 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm set-points, the procedure to be followed, and the expected test result. Both Ship Service Generator's low lube oil pressure automatic shutdowns were not shutting down in accordance with the vessel's current Periodic Test Procedures (PSTP). Submit an amendment of the vessel's current PSTP for the RESOLVE Pioneer's Alarm Testing Procedures (Procedure Number: EG-1) (Testing Generator Low Lube Oil Pressure Alarm and Shut-down), on company letterhead to USCG MSD Dutch Harbor. In the letter, specify what you are modifying and what steps you are looking to add/remove for the CG to approve the amendment to the PSTP and a reason for the modification. Consult with the manufacturer's instructions to obtain the automatic shutdown parameters of the engine and include them in the letter. In addition, after approval of PSTP, vessel must demonstrate proper testing of automated vital system in accordance with 46 CFR 62.30-10 to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 21 June 2021
Resolution: Procedure was amended by the company and accepted by Sector Anchorage
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 23 February 2021 Resolved
All ships of 150 gross tonnage and upwards and passenger ships irrespective of size shall, in addition to the requirements of paragraph 2.1, be fitted with: a bridge navigation watch alarm system (BNWAS), as follows: cargo ships of 150 gross tonnage and upwards but less than 500 gross tonnage constructed before 1 July 2011, not later than the first survey after 1 January 2018. Vessel does not have an installed BNWAS. Install a BNWAS prior to sailing international to the satisfaction of the attending USCG Marine Inspector.
Action required: 702 - Prior to embarking on international voyage
Resolved 4 May 2021
Resolution: Vessel installed BNWAS, test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 February 2021 Resolved
Automated vital systems must be tested in accordance with subpart 61.40 of this chapter. Vessel was not able to demonstrate the proper low LO level alarm and shutdown on the #2 SSDG IAW the approved PSTP for automation. Vessel must demonstrate proper testing of #2 SSDG to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 31 May 2021
Resolved 28 May 2021
Resolution: Vessel will be ammending the test procedure document for the SSDG's low lube oil shut-down, to reflect its current shutdown parameters. Issued new CG-835 on 28MAY21 for them to ammend procedures.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2020 Resolved
Propulsion shaft oil anlysis has not been conducted on a semi-annual basis as required by 46 CFR 61.20-17(e)(3). Provide sampling history and records to prove recommended oil change has been conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 21 August 2020
Resolution: Vessel had oil sample drawn and tested, sample was drawn 11AUG2020.Test reported no abnormalities.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 June 2020 Resolved
Crop and renew wasted quick acting hatch sealing ring for chain locker, located in galley.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 21 August 2020
Resolution: WTH was renewed and to the satisfaction of the attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 May 2020 Resolved
There shall be at least two means of escape from all general areas accessible to where the crew may be quartered or normally employed. 02 emergency escape hatches for the engine room have thicker gasket material that requires the hatches to be ratcheted down with additional force - utilizing a wrench. This additional force makes it impossible for crew members to escape the engine room, utilizing the hatch, without the assistance of a wrench.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2020
Resolved 18 May 2020
Resolution: Gaskets renewed with correct size and securing dogs correctly adjusted.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 11 May 2020 Resolved
For each watertight door in a required subdivision bulkhead, an indicator light must be installed in the pilothouse. The watertight door indicating panel, located in the pilothouse, does not illuminate for the engine room door due to a faulty sensor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2020
Resolution: Door switch renewed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 11 May 2020 Resolved
Every Company should develop, implement and maintain a safety management system which includes: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag legislation. The instructions and procedures are not followed onboard. SMS procedures audit is required to be conducted by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 31 July 2020
Resolution: Vessel had ABS conducted the external SMS audit.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 May 2020 Resolved
Inspector not limited from making such tests or inspections deemed necessary. Vessel crew is unable to demonstrate operation of installed OWS (OWS not required per CFR.)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2020
Resolution: Crew demonstrated proper operation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2020 Resolved
No change shall be made in the vessel's structure, equipment, arrangement, material, or scantlings without the specific approval of the assigning and issuing authority. Vessel has a temporary repair, located at the outboard port side "tugger deck", that uses a doubler plate and silicon for repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 13 July 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 May 2020 Resolved
Items found to be in unsatisfactory condition shall be repaired or renewed in order to place the vessel in satisfactory condition. Vessel has a separated weld located centerline about 20' aft of the H bit. Significant corrosion also identified at the H bit deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 13 July 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 May 2020 Resolved
It shall be to the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment is provided, maintained and replaced as indicated. Visual inspection of fires hoses, located interior and exterior, show signs of degradation. Recommend 100 PSI test of hoses for verification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 19 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 11 May 2020 Resolved
Each self-propelled vessel over 150 gross tons when engaged on an international voyage must have on board an efficient daylight signaling lamp that may not be solely dependent upon the vessel's main source of electrical power. Vessel's signaling lamp does not have independent power supply.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 22 May 2020
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 May 2020 Resolved
Entries shall be made in the oil record book (ORB) on each occasion to include disposal of oil residues, discharge overboard or disposal otherwise of bilge water that has accumulated in machinery space. The ship's master should obtain from the operator of the reception facility receipts that detail the discharge. The ORB did not have receipts of discharge kept with the ORB.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 May 2020
Resolution: Receipts acquired from receiving facility for past three transfers. (Resolve Marine)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 May 2020 Resolved
If your vessel's Certificate of inspection is renewed less often than annually the marine inspector must check the settings of the safety or relief valves twice every 5 years but no more than 3 years may lapse. Relief valves are due for testing, however calibrated test gauges have not been calibrated in many years.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2019 Resolved
Unable to operate generators in parallel as designed. Prove proper operation of generators in parallel and reverse power relay per PSTP's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 14 May 2019
Resolution: Tech was hired who adjusted frequency for both gens. Successfully ran both gens in parellel and tested reverse power relay on both. Def Cleared.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 May 2019 Resolved
Vessel has two port and stbd tonnage openings on the main deck that were found with caulking and gaskets. Required to remove gaskets and caulking to meet regs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: Tonnage openings were removed and straightened. Caulk and gasket was removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 May 2019 Resolved
Two watertight doors on maindeck aft house bulkhead failed the chalk test and were found with loose dogs. Make all watertight doors watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: Water tight doors were adjusted and passed chalk test.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 May 2019 Resolved
Reach rod for the #9 fuel shutoff valve located on port side of engine room was found inoperatable. Prove proper operatin of remote valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 14 May 2019
Resolution: Crew replaced broken cotter pin and showed proper operation of reach rod.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019 Resolved
Numerous electrical installations around the ship were found deadended. Power strips were found daisy chained. Extension cords were found as permanent installations. Replace extension cords were approved wire, remove daisy chained power cords, and remove deadended cables or place in junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: All identified electrical issues were repaired or removed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 May 2019 Resolved
Lagging around exhaust manifold on bowthruster engine was sagging and exposing hot surface near fuel source. Replace or re-secure lagging around manifold.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: Lagging was re-wrapped around exhaust.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019 Resolved
Crew installed a home use battery charger in the welding room via zip ties. Replace with an approved battery charger and properly install charger.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 14 May 2019
Resolution: Charger was removed from service. Def Cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2019 Resolved
Employers must maintain records of chemical test as provided in 49CFr40.33 and must make these records available to the coast Guard upon Request. Vessel could not provide DAPI documentation for the crew to include pre-imployment test and enrollment with a consortium. Provide requested documents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: DAPI records were provided for all crewmembers on board.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 13 May 2019 Resolved
Entries shall be made in the oil record book on each occasion to include disposal of oil residues, discharge overboard or disposal otherwise of bilge water that has accumulated in machinery space. The ORB did not match any receipts for disposal of oily waist over the last two years.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2019
Resolved 13 May 2019
Resolution: Conducted training with Master and Chief Engineer on the requirements of the Oil Record book.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 13 May 2019 Resolved
Hand railing on the starboard side was found wasted and cracked. Repair or replace hand rails.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: hand railings were repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2019 Resolved
Could not provide documentation that EAP training was being conducted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 17 June 2019
Resolution: Received documentation of completed DAPI training.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 May 2018 Resolved
Remove exhaust lagging on STBD exhaust piping and adjust piping to ensure it does not chaff on electrical wiring from house generator.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2018
Resolved 25 July 2018
Resolution: Piping was adjusted, lagging replaced and wiring re-ran and support to ensure wire didn't chaff. Def cleared.
Documentation › Logs/Records › Drug Test Records
Issued 14 May 2018 Resolved
Must have the ability to conduct chemical testing while underway outside 32hrs from testing facility.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: Captain was certified and received chemical testing equipment from local testing facility.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 17 April 2018 Resolved
Refer to OCMI letter dated 26 Apr 2018.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2018
Resolved 25 July 2018
Resolution: Primary mechanical pump for port controllable pitch propeller was replaced and tested satisfactory. Def Cleared.
Lifesaving › Rescue Boat › Inflated Condition
Issued 18 August 2017 Resolved
Rescue boat must be in satisfactory condition prior to departure from dry dock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2017
Resolution: Corrected.
Lifesaving › Rescue Boat › Construction
Issued 18 August 2017 Resolved
Rescue boat must be USCG approved under 46CFR160.056 and equipped as per 46CFR199.175.
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 24 January 2018
Resolution: Corrected.
Engineering › Pressure Vessel › Weld
Issued 18 August 2017 Resolved
Each pressure vessel listed on the COI must be either internally examined or hydrostatically tested tested to 1.25 MAWP to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 September 2017
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 23 May 2017 Resolved
The low lube oil pressure shutdown for the port mde did not operate as required by the approved automation test procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 3 July 2017
Resolution: Verified the repair of the Port MDE was made and verified operation.
Operations/Management › Vessel Activity › Other
Issued 18 May 2017 Resolved
The vessel's 2017 annual inspection was started on 18MAY17 (to begin prior to the end of its annual inspection window), but could not be completed without a qualified USCG Machinery Inspector. The vessel must complete its annual inspection with a qualified USCG Machinery Inspector to conduct the machinery portion of the inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 23 June 2017
Resolution: Machinery inspection was completed with 01 deficiency issued. //[name withheld]//
Fire Fighting › Fire Pumps › Power Source
Issued 25 July 2012 Resolved
Prove Operation of Emergency Fire Pump IAW 46CFR95.10-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2012
Resolution: Operation of the emergency fire pump was witnessed to be in satisfactory condition, IAW 46CFR95.10-5.
Electrical › Electric Generation Source (service) › Generator
Issued 25 July 2012 Resolved
Prove Operation STBD Generator IAW 46 CFR 111.10-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2012
Resolution: Witnessed satisfactory operation of the STBD generator, to include re3ferse power relay and low lube oil alarm/shutdown, IAW 46 CFR 111.10-3.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 June 2012 Resolved
While conducting random hydro of ballast tanks #7s sprung hole and started leaking water in the alleyway. Similar hole was found in tank 4P but this time on fwd bulkhead. Issued 835 for repairs to be made prior to departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2012
Resolution: Received report from ABS that repairs were tested satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2010 Resolved
Attached machinery guard to port main generator on inboard side.
Condition: Improper Installation
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed guard properly installed.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 22 November 2010 Resolved
Properly mount junction boax on inboard side of port generator.
Condition: Damaged By Earlier Event
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed junction box properly mounted.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 November 2010 Resolved
Exhaust lagging on internal compbustion engines in main engine room is loose or missing. Renew/re-attach lagging as discussed.
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed properly installed lagging.
Construction/Loadline › Structures › Trunk
Issued 22 November 2010 Resolved
Section of ventilation system missing in main machinery space. Replace missing section.
Condition: Improper Installation
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed the ventilation hood re-installed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 November 2010 Resolved
Potable water system has flexible non-metallic hose as temporary repair to PW system. Repair section of piping with fixed piping per original design.
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed fixed piping installed.
Engineering › Pressure Vessel › Relief Valve
Issued 22 November 2010 Resolved
Relief valve on HW heater is 150 psi. Relief should be 100 psi and meet 46 CFR 53.01-10, or HW heater should conform to specification as a pressure vessel. Replace relief valve.
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed relief valve replaced to 100 psi.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 November 2010 Resolved
Renew missing labels on main switchboard.
Due 22 December 2010
Resolved 30 November 2010
Resolution: Witnessed lables on switchboard.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 November 2010 Resolved
Identify and correct ground as detected on main switchboard.
Due 22 December 2010
Resolved 30 November 2010
Resolution: Ground detected all satisfactory.
Stability › Water on Deck › General
Issued 22 November 2010 Resolved
(3) escape hatches/trunks for main machinery space and steering compartment are deteriorated and allow water ingress. Renew/repair and demonstrate satisfactory hose test and chalk test on each.
Due 22 December 2010
Resolved 30 November 2010
Resolution: All escape hatches found satisfactorily.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 22 November 2010 Resolved
Vessel to remove unapproved crane that was installed by company with plan submitted
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 21 January 2011
Resolution: Crane removed, vessel departed zone.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 29 October 2010 Resolved
Issued 835 for stbd side crane which was installed without proper approval from MSC IAW 46 CFR 91.55-10. Crane was present on 11-30-2010. Vessel rep will remove the crane before leaving port IAW the 835 issued.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2010
Resolved 21 January 2011
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 3 December 2009 Resolved
Currently there is excess gear in the Auxilliary Generator space that creates a fire hazard. Remove all excess gear and stow in proper location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 3 December 2009
Resolution: Items were removed.
Lifesaving › Rescue Boat Equipment › Radar Reflector
Issued 30 November 2009 Resolved
The current item that was homemade is not a sufficient radar reflector, Provide a radar reflector as per 46 CFR 199.175
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 7 January 2010
Resolution: Provided a radar reflector as per 46 CFR 199.175
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 30 November 2009 Resolved
The current searchlight is not operating, provide and operable searchlight as per 46 CFR 199.175
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 7 January 2010
Resolution: provided a searchlight as per 46 CFR 199.175
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 November 2009 Resolved
Currently there is no lifejacket donning placards in staterooms and other locations where lifejacket are stowed as required by 46 CFR 199. Each area where lifejackets are stowed is required to have a placard showing the proper procedures for donning a lifejacket. Provide and post the required placards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 7 January 2010
Resolution: Provided and posted the required placards.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 November 2009 Resolved
Currently, there is not a Lifesaving Equipment Maintenance log as required by 46 CFR 199.190. Provide a Lifesaving Equipment Maintenance Log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Created and provided a Lifesaving Equipment Maintenance Log.rovided .
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 30 November 2009 Resolved
The current Ship Safety Radio Certificate is expired, provide a current certificate as per 46 CFR 80.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Ship Safety Radio Certificate is not required for this vessel
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 30 November 2009 Resolved
Currently there is not an Coast Guard approved set of automation test procedures onboard. Provide and prove these procedures as per 46 CFR 62.20-1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Automation test procedures were approved by MSC, [name withheld] verified test procedures were sufficient and verified testing conducted by ship personnel. Stamped procedures "Approved".
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 30 November 2009 Resolved
Currently there are flammable aerosol containers located in the electrical storage room. Remove these items and stow in properly protected location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Items were removed and placed in a proper location.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 November 2009 Resolved
All electrical circuit panel boards are required to have a circuit directory that reflects circuit designation, load description and the rating of the circuit as per 46 CFR 111.40-11. Currently there are panel boards that do not have this required information.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: All panels were updated with the required information.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 November 2009 Resolved
Currently the main switchboard has a circuit breaker that is not labeled. Label the unidentified circuit breaker as per 46 CFR 111.30.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Circuit breaker was labeled properly.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 30 November 2009 Resolved
The lube oil drain locate at the forward port side of the engine room does not have a cap. Provide and install a new cap on this drain.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Cap was installed.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 30 November 2009 Resolved
This vessel is required to have a Oil Discharge Placard in the engine room as per 33 CFR 155.450. The placard is missing. Provide and install as applicable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 10 December 2009
Resolution: Oil discharge placard was installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 December 2008 Resolved
Provide vertical and horizontal supports for electrical cable in the generator space
Condition: Improper Installation
Due 29 January 2009
Resolved 31 December 2008
Resolution: Cable is supported.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 29 December 2008 Resolved
Provide a diamond day shape per 72 COLREGS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 February 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 December 2008 Resolved
Provide a lifeline on the aft lifebuoy per 46 CFR 199.70(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 February 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 December 2008 Resolved
Demonstrate proper operation of aft compass repeater on bridge per 46 CFR 96.17-1.
Condition: Unknown
Due 29 January 2009
Resolved 31 December 2008
Resolution: Repeater operates properly.
Communications › Visual Communication › Signalling Lamp
Issued 29 December 2008 Resolved
Provide a battery and a dedicated branch circuit for the signaling light per 46 CFR 112.15-1(m) and 112.43-9.
Condition: Improper Installation
Due 29 January 2009
Resolved 31 December 2008
Resolution: Signalling lamp has a battery and two outlets with a dedicated branch circuit were installed on bridge.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 29 December 2008 Resolved
Provide a copy of the automation test procedure that has been approved by the Coast Guard per 46 CFR 62.20-1.
Due 29 January 2009
Resolved 10 December 2009
Resolution: Procedures provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 December 2008 Resolved
Display schematic diagram of the CO2 system at or near the pull stations of spaces protected by a fixed CO2 extinguishing system per 46 CFR 95.15-10.
Due 29 January 2009
Resolved 31 December 2008
Resolution: Schematic diagrams have been posted.
Lifesaving › Rescue Boat Equipment › Radar Reflector
Issued 29 December 2008 Resolved
Provide a radar reflector, a whistle, and a fire extinguisher in the rescue boat per 46 CFR 199.175.
Due 29 January 2009
Resolved 31 December 2008
Resolution: Radar reflector, whistle, and fire extinguisher have been provided in rescue boat.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 December 2008 Resolved
Provide flame-resistant sight glass on fuel tank per 46 CFR 56.50-80.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 February 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 December 2008 Resolved
Provide current compass deviation table per 96.17-1.
Due 29 January 2009
Resolved 31 December 2008
Resolution: Swung the compass and posted updated deviation table.
Documentation › Logs/Records › Logbook (official)
Issued 27 July 2007 Resolved
Vsl allowed to proceed in an un-inspected status to Port of Mobile, AL. to undergo preparation for an Coast Guard inspection certification. An assist tug is required for transit. Vsl is to contact local OCMI immediately upon arrival. Passengers and cargo are prohibited during transit.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 31 July 2007
Resolution: COMPLETED
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 June 2007 Resolved
Provide and demonstrate proper operation of a bilge monitor for the oily water seperator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 10 October 2007
Communications › Visual Communication › Signalling Lamp
Issued 14 June 2007 Resolved
Demonstrate proper operation of the engine room sound power phone visual indicator on emergency power.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 25 September 2007
Lifesaving › Launching Appliances › Davit
Issued 14 June 2007 Resolved
Provide MSC approval for rescue boat davit foundation.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 9 February 2009
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 June 2007 Resolved
Demonstrate secondary power to the KOYO direct logic 06 PLC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 25 September 2007
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 14 June 2007 Resolved
Demonstrate proper operation of the #3 ship service generator low jacket water level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 10 October 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 14 June 2007 Resolved
Demonstrate proper operation of the high exhaust temperture for the #3 ship service generator.
Condition: Unknown
Due 14 October 2007
Resolved 21 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 8 April 2005 Resolved
Misc. general alarm bells did not operate when tested. Crew adjusted and proved proper operation.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 7 April 2005 Resolved
Steering failure alarm did not operate when tested. Alarm was repaired and retested sat.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Fire Fighting › Fire Hydrants › Material
Issued 5 April 2005 Resolved
Multiple fire hydrants not ready for immediate use, i.e. hoses not attached, nozzles not attached. Corrected all discrepancies and placed all hydrants in a ready status.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Engineering
Issued 14 January 1997 Resolved
PROCEED TO DRYDOCK IN SEWARD, AK AND MAKE PERMANENT REPAIRS TO THE PORT STERN TUBE SEAL.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Fire Fighting
Issued 8 February 1996 Resolved
REMOVE ALL HALON FIXED FIRE EXTINGUISHING SYSTEM ACTUATION CONTROLS FROM VESSEL.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Lifesaving
Issued 8 February 1996 Resolved
INSTALL RETROREFLECTIVE TAPE ON NEW RING BUOYS MOUNTED ON MAIN DECK AFT BULKHEAD OF WHEELHOUSE.
Condition: Unknown
Due 8 February 1996
Resolved 26 February 1996
Fire Fighting
Issued 8 February 1996 Resolved
UPDATE VESSEL'S FIRE AND SAFETY PLAN TO INCLUDE NEWLY INSTALLED FIXED CO2 SYSWTEM. SUBMIT UPDATED PLAN TO LOCAL OFFICER IN-CHARGE MARINE INSPECTION FOR APPROVAL.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Engineering
Issued 8 February 1996 Resolved
PROVIDE SIGHT GLASS GUARD FOR ANTI-FREEZE TANK FOR AFT WINDLASS.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Accommodation/Occupational Safety
Issued 8 February 1996 Resolved
REPAIR VENTILATION COVER IN CREW HEAD ON THE O2 DECK.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Electrical
Issued 8 February 1996 Resolved
REPAIR AND PROVE PROPER OPERATION OF EMERGENCY LIGHT IN VICINITY OF AFT EXIT, MAIN DECK OF WHEELHOUSE.
Condition: Unknown
Due 8 February 1996
Resolved 26 February 1996
Accommodation/Occupational Safety
Issued 8 February 1996 Resolved
REMOVE HOSES BLOCKING EGRESS PATH FROM STEERING SPACE TO EMERGENCY EXIT.
Condition: Unknown
Due 8 February 1996
Resolved 26 February 1996
Electrical
Issued 7 December 1994 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE FOLLOWING TRIPS AND ALARMS FOR EMERGENCY GENERATOR: OVERSPEED TRIP, LOW LUBE OIL ALARM AND HIGH JACKET WATER TEMP ALARM.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Electrical
Issued 7 December 1994 Resolved
PROVE PROPER OPERATION OF THE HIGH JACKET WATER TEMP AND LOW LUBE OIL PRESSURE ALARMS.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Construction/Loadline
Issued 7 December 1994 Resolved
MAKE PROPER PERMANENT REPAIR AND PROVE PROPER OPERATION OF STBD BILGE PUMP.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Lifesaving
Issued 7 December 1994 Resolved
CONDUCT FIRE AND BOAT DRILL.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Electrical
Issued 7 December 1994 Resolved
REPAIR EXPLOSION PROOF FIXTURE MOUNTED IN THE VICINITY OF THE DIESEL FUEL TANK LOCATED IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Electrical
Issued 7 December 1994 Resolved
REMOVE DUCT TAPE COVERING HOLE IN ELECTRICAL PANEL LOCATED IN ENGINE CONTROL ROOM AND INSTALL PROPER COVER.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Construction/Loadline
Issued 7 December 1994 Resolved
REMOVE WOODEN PLUG LOCATED IN DRAIN TO CERTIFIED BALLAST TANK #P10 AND INSTALL PROPER METAL PLUG.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Construction/Loadline
Issued 7 December 1992 Resolved
REMOVE CAULKING FROM TONNAGE OPENINGS_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 February 1993
Resolved 3 February 1993
Unknown
Issued 27 November 1991 Resolved
ALL CFR`S ON VESSEL ARE OUTDATED.
Condition: Unknown
Due 15 December 1991
Resolved 15 May 1992
Engineering
Issued 27 November 1991 Resolved
ALL AIR RECIEVER SAFTY VALVES ARE SET ABOVE ALLOWABLE LIMITS
Condition: Unknown
Due 15 December 1991
Resolved 15 May 1992
Fire Fighting
Issued 27 November 1991 Resolved
FIRE HOSES ARE NOT OF AN APPROVED TYPE.
Condition: Unknown
Due 15 December 1991
Resolved 15 May 1992
Documentation
Issued 18 July 1991 Resolved
PROVIDE [name withheld] WITH REVISED COPY OF STABILITY LETTER PRIOR TO 31AUG91 OR CEASE ALL OPREATIONS UNTIL SUCH TIME AS A STABILITYLETTER IS PROVIDED. VESSELS OPERATION IS RESTRICTED TO PRINCE WILLIAM SOUND AND TRANSIT FROM SEATTLE TO PRINCE WILLIAM SOUND.
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Deck/Cargo
Issued 18 July 1991 Resolved
CRANE IS NOT TO BE PLACED IN SERVICE UNTIL SUCH TIME AS MSO PUGET SOUND IS PROVIDED COPIES OF APPROVED PLANS OF CRANE INSTALLATION.
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Engineering
Issued 4 November 1990 Resolved
REPAIR PORT AND STARBOARD PILOT HOUSE EMERGENCY ENGINE STOP.
Condition: Unknown
Due 4 November 1990
Resolved 4 November 1990
Documentation
Issued 4 November 1990 Resolved
PROVIDE COPY OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 4 November 1990
Resolved 4 November 1990
Electrical
Issued 4 November 1990 Resolved
REPAIR LOW LUBE ALARM TO BOTH GENERATORS.
Condition: Unknown
Due 4 November 1990
Resolved 4 November 1990
Documentation
Issued 4 November 1990 Resolved
PROVIDE EVIDENCE THAT THE TRIM AND STABILITY BOOKLET, DATED 17 DECEMBER 1982, REVISION E, IS ON BOARD THE VESSEL.
Condition: Unknown
Due 4 November 1990
Resolved 4 November 1990
Construction/Loadline
Issued 23 March 1990 Resolved
CROP AND RENEW TRANSVERSE DEEP WEB FRAME #3 STARBOARD SIDE IN STEERING COMPARTMENT A NEXT DRYDOCK.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Documentation
Issued 25 October 1989 Resolved
POST ON BOARD THE VESSEL'S CURRENT STABILITY LETTER ISSUED 10NOV89 BY THE EIGHT COAST GUARD DISTRICT MMT OFFICE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Navigation
Issued 25 October 1989 Resolved
REPAIR THE SOUND POWERED TELEPHONES LOCATED IN THE AFTER STEERING ROOM AND IN THE GENERATOR CONTROL ROOM.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
MAKE OPERATIONAL THE GOVERNOR CONTROL FOR NUMBER THREE GENERATOR LOCATED ONTHE GENERATOR PANEL.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Engineering
Issued 25 October 1989 Resolved
CONDUCT A HYDROSTATIC TEST AT 1-1/4 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE OF ALL THE VESSEL'S AIR RECEIVERS WITH THE EXCEPTION OF THE DRY BULK CARGO TANKS. TEST TO BE CONDUCTED IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Fire Fighting
Issued 25 October 1989 Resolved
PROVIDE PROOF OF REFILLING OF THE EMPTY HALON CYLINDER NUMBER 0391 IN THE ENGINE ROOM. AT NEXT DRYDOCKING, HAVE ALL FIXED FIREFIGHTING CYLINDERS HYDROSTATICALLY TESTED AT A DOT APPROVED FACILITY (W.H. BRENNAN, SINGAPORE IS THE ONLY AUTHORIZED DOT TESTING FACILITY IN ASIA).
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Engineering
Issued 25 October 1989 Resolved
CONDUCT IN THE PRESENCE OF A MARINE INSPECTOR A FULL TEST OF THE SHIP'S AUTOMATION PROCEDURES. MACHINERY SPACE IS TO BE MANNED WHILE VSL IS UNDERWAY. A LICENSED ASST ENG IN ADDITION TO THE C/E AND 2 OILERS ARE REQUIRED UNTIL THIS ITEM IS RESOLVED.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989

Casualty record · 9

17 October 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1693623
2 February 2004Routine · role: Involved in a Marine Casualty · activity 2013276
7 December 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3910677
10 November 2013Routine · role: Transiting Vicinity of Primary Subject · activity 4771754
6 December 2017Routine · role: Involved in a Marine Casualty · activity 6334465
13 April 2018Routine · role: Involved in a Marine Casualty · activity 6395188
23 May 2018Routine · role: Involved in a Marine Casualty · activity 6563420
20 June 2021Routine · role: Involved in a Marine Casualty · activity 7261648
10 January 2023Routine · role: Involved in a Marine Casualty · activity 7620896
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PIONEER SERVICE (2002–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.