Records from 1982 to 1999. Most recent: inspection, 29 January 1999.
Inspection history · 40
29 January 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 790104
19 August 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 796999
25 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33469
16 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108512
16 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 722631
12 January 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107665
8 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777654
5 December 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470704
7 March 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099756
7 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431732
19 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 46540
7 December 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367591
30 November 1994
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1356917
12 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 676759
22 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101251
22 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 146943
4 January 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 850310
18 November 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1161586
20 August 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141785
21 September 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 958257
7 November 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1315997
27 February 1991
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1244434
14 November 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219410
2 November 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 924171
1 December 1989
MARPOL Annex II Examination · Examination of Repairs · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913889
23 November 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 896310
30 November 1987
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1028615
4 June 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1334860
5 May 1987
Hull Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1017910
12 November 1986
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1334482
21 February 1986
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1305299
6 December 1985
COI Inspection · Credit Drydock
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 990869
12 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1289345
1 November 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284810
19 June 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972717
24 June 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 967865
5 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966593
5 November 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973203
5 November 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1274675
14 February 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281514
Electrical
Issued 5 December 1997
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
REPAIR FUEL OIL LEAK FRONT OF PMDE.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
PROVE PROPER OPERATION OF MDE OVERSPEED TRIPS.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Electrical
Issued 5 December 1997
Resolved
PROVE PROPER OVERSPEED RPM'S AND OPERATION ON BOTH S/S GEN'S. TACHS WERE_x001C_ INOP.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
REPAIR LUBE OIL LEAK ON STBD MDE PRELUBE SYSTEM.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Electrical
Issued 5 December 1997
Resolved
RENEW FLEXIBLE FUEL LINES W/APPROVED FUEL HOSES ON BOTH S/S GEN'S.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Deck/Cargo
Issued 5 December 1997
Resolved
INSTALL AND PROVE RELIEF VALVE ON AIR COMP ENGINE DISCHARGE LINE.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
RENEW FLEXIBLE FUEL HOSES W/APPROVED HOSE ON MDE'S.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Lifesaving
Issued 5 December 1997
Resolved
PROVIDE PROPER SIZE ENGINE FOR RESCUE BOAT.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Navigation
Issued 5 December 1997
Resolved
REPAIR RUDDER/STEERING CONTROL LINKAGE SYSTEM AND PROVE OPERATION.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
REPAIR COOLANT LEAK ON FRONT AND REAR OF STBD MDE.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Engineering
Issued 5 December 1997
Resolved
RENEW FLEXIBLE FUEL LINES W/APPROVED HOSES S/S GEN'S.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Deck/Cargo
Issued 5 December 1997
Resolved
PROVE/PROVIDE PROPER PIPE SIZE FOR P-TANK RELIEF VALVES AND PROVE OPERATIONOF RELIEF VALVES.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Construction/Loadline
Issued 5 December 1997
Resolved
C/R WASTED BULKHEAD BOTTOM OF STBD STACK/ESCAPE TRUNK.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Fire Fighting
Issued 5 December 1997
Resolved
UPDATE AND PROVIDE APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Fire Fighting
Issued 5 December 1997
Resolved
PROVIDE PRESSURE GAUGE FOR FIREMAIN IN PILOTHOUSE.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Lifesaving
Issued 5 December 1997
Resolved
VESSEL'S ROUTE IS RESTRICTED TO PORT OR UNTIL VESSEL PROVIDES 02 LIFERAFTS ARE ONBOARD.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Deck/Cargo
Issued 7 February 1997
Resolved
TEST FUEL AND CARGO TRANSFER HOSES AS PER 33CFR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Engineering
Issued 7 February 1997
Resolved
INJSTALL CORRECT FUEL FILTER TO STBD MAIN ENGINE TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 7 February 1997
Resolved
INSTALL PFD STOWAGE AREA IN CREW BERTHING TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 7 February 1997
Resolved
INSTALL LIFERAFT LAUNCHING DEVICES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Fire Fighting
Issued 7 February 1997
Resolved
INSTALL FIRE HYDRANTS AS PER 46CFR95 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Navigation
Issued 7 February 1997
Resolved
INSTALL SHAFT TACHS AS PER 46CFR113 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Engineering
Issued 7 February 1997
Resolved
CORRECT FUEL TRANSFER PROCEDURES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 1 December 1989
Resolved
PLACE ONBOARD AN ACCEPTABLE RESCUE BOAT.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 5 May 1987
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF THE ENGINE ROOM EMERGENCY BILGE PUMPING SYSTEM.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 6 December 1985
Resolved
HAVE LOW LUBE OIL VISUAL ALARM ON BRIDGE PANEL REPAIRED OR REPLACED NO LATER THAN 06 JAN 86 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Lifesaving
Issued 1 November 1984
Resolved
PROVIDE LIFEJACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
REPLACE GASKET AT DECK ACCESS TO CHAIN LOCKER.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
RENEW OPERATING SWITCH AND MAIN SWITCH TO ANCHOR WINDLASS WITH WATERPROOF TYPE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Documentation
Issued 1 November 1984
Resolved
PROVIDE PROOF OF FINANCIAL RESPONSIBILITY FOR OIL POLLUTION.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
TEST OVERSPEED ON PORT GENERATOR.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Accommodation/Occupational Safety
Issued 1 November 1984
Resolved
PROVIDE NON-SKID SURFACE AT LADDERS AND WALKWAYS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Navigation
Issued 1 November 1984
Resolved
PROVIDE SUITABLE CHART PAPER FOR FATHOMETER.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Navigation
Issued 1 November 1984
Resolved
PROVIDE DEVIATION TABLE FOR COMPASS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
PROVIDE TWO (2) FIRE EXTINGUISHER BRAKCETS FOR ENGINE ROOM AND MACHINERY SPACE AT STAIRWAY.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
MAKE PERMANENT THE WIRING TO PRESSURE SWITCHES AT AIR COMPRESSORS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
HAVE FIXED C02 SYSTEM SERVICED.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984