Records from 1981 to 2005. Most recent: inspection, 6 April 2005.
Inspection history · 46
6 April 2005
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2327679
28 June 2004
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2113361
3 June 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087731
7 November 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1943608
8 November 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1694109
3 July 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1632449
15 November 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1418999
22 June 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470267
12 November 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401127
27 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393009
26 June 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463387
25 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33469
25 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126566
12 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 65739
12 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430473
8 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68572
15 November 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437167
26 June 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462511
13 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428545
5 December 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461616
2 June 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354735
11 January 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354531
26 November 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 59351
28 January 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1134632
16 June 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382491
6 April 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1254980
28 January 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 959778
24 October 1991
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941695
30 September 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 224775
21 March 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229522
26 October 1990
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215414
9 April 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221478
20 September 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1308960
25 April 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032439
5 May 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348956
5 November 1987
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1025209
22 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319314
13 May 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027841
27 June 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991958
3 December 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990188
25 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292344
3 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975049
4 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965981
14 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968623
5 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277769
6 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969508
Engineering › Bilge Water Management System › Interface Detector
Issued 16 July 2004
Resolved
Prove proper operation of the bilge high level alarm panel as required by 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 16 July 2004
Resolution: Witnessed satisfactory operation of the bilge high level alarm panel.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 July 2004
Resolved
Provide a new battery box for battery located in the generator space as required by 46 CFR 183.350(e).
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 16 July 2004
Resolution: Inspected the installation of a new battery box for battery located in the generator space.
Fire Fighting › Fire Hoses › Condition
Issued 16 July 2004
Resolved
Provide a new fire hose for the fire station located on the main deck as required by 46 CFR 181.320(b)(1).
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 16 July 2004
Resolution: Vessel provided a new fire hose for the main deck fire station.
Engineering › Bilge Water Management System › Not Operational
Issued 28 June 2004
Resolved
Crop and re-new forepeak reach rod.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected the installation of a new forepeak reach rod.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Gouge and weld 4 cracked welds in #1 void as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected satisfactory repairs of cracked welds.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Gouge and weld 3 cracked welds in forepeak as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected proper repairs of cracked welds.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Gouge and weld approximately 6" of side shell seam located in port ballast tank as marked.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected the welding of 6" of side shell in port ballast tank.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Gouge and weld 4 cracked welds in engine room as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected the proper repairs of all cracked welds.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Gouge and weld crack on port generator exhaust side shell penetration.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected satisfactory repairs of crack in port generator exhaust side shell penetration.
Construction/Loadline › Hull › Weld
Issued 28 June 2004
Resolved
Clad weld several pits on bottom shell as marked.
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 July 2004
Resolution: Inspected satisfactory clad welding of pits on bottom shell.
Construction/Loadline › Hull
Issued 3 July 2002
Resolved
Install 18" X18" insert in way of port side corner wrapper aft lazarette. All repairs shall be to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Hull Plating
Due 3 July 2002
Resolved 3 July 2002
Resolution: Witnessed satisfactory testing of inserted area. All repairs were found to be satisfactory.
Construction/Loadline › Hull
Issued 3 July 2002
Resolved
Reweld cracked welds noted in the port middle ballast tank. All repairs are to be to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bracket
Due 3 July 2002
Resolved 3 July 2002
Resolution: Examined and found satisfactory repairs to cracked welds noted above.
Construction/Loadline › Hull
Issued 3 July 2002
Resolved
Reweld crack welds noted on floor frames in fresh water tanks. All repairs shall be completed to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bracket
Due 3 July 2002
Resolved 3 July 2002
Resolution: Examined and found satisfactory welding of factured weld on floor frames as indicated above.
Construction/Loadline › Hull
Issued 3 July 2002
Resolved
Reweld fracture weld to side long as marked in void below galley compartment. All repairs shall be completed to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bracket
Due 3 July 2002
Resolved 3 July 2002
Resolution: Examined and found satisfactory rewelding of fractured weld as noted above.
Construction/Loadline › Hull
Issued 3 July 2002
Resolved
Repair four cracked welds noted and marked in lazarette. All repairs shall be completed to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bracket
Due 3 July 2002
Resolved 3 July 2002
Resolution: Examined and found satisfactory rewelding of fractured welds noted above.