Records from 1981 to 2025. Most recent: inspection, 1 December 2025.
Inspection history · 76
1 December 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8275712
24 January 2025
Annual Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8069497
18 October 2023
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7810584
18 April 2023
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7670963
15 February 2023
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7637307
16 November 2021
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7352040
4 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7215516
17 September 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7060046
13 August 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7031696
22 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6860600
19 November 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6857497
30 April 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6674214
19 November 2018
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6583249
29 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6428269
4 December 2017
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6318970
22 May 2017
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6152156
2 November 2016
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6034189
4 December 2015
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5775569
9 November 2015
Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5759878
22 May 2012
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4319095
12 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4223861
3 January 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3922746
6 December 2010
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3905327
12 January 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3662510
28 April 2009
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3462823
3 December 2008
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3372352
2 November 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3091982
14 May 2007
Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2930008
16 November 2005
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2535874
27 April 2005
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2343970
12 November 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2240039
29 October 2003
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1936996
18 July 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1850136
27 May 2003
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1802886
11 February 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742848
16 April 2002
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1603119
9 February 2001
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1521838
7 July 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1051318
9 May 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391309
26 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 97778
20 September 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393238
14 September 1999
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1120837
10 May 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463468
7 July 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398925
15 September 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371982
19 May 1997
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411469
10 May 1996
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1082167
10 May 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1355796
13 September 1995
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407551
18 May 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374288
18 May 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444848
9 September 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 842927
12 May 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 842272
12 May 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1266274
23 October 1991
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 936665
16 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919134
18 May 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234987
19 March 1990
Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930682
18 January 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239757
31 October 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 497188
5 June 1989
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1352533
18 January 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 892048
14 December 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1348293
9 June 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1204365
17 June 1987
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1313852
23 September 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319358
28 April 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988874
22 October 1985
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1296379
17 September 1985
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 990231
4 October 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1286798
19 September 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1283441
13 March 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970923
21 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973415
21 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275761
23 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277028
4 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277094
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 January 2025
Resolved
Vessel must have a reliable means for shutting down a propulsion engine, at the main pilothouse control station, which is independent of the engine's speed control.
Main engine fuel supply emergency shut off valve was inoperable
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2025
Resolved 28 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 February 2023
Resolved
Rigid non-metallic materials are acceptable for use in bilge piping systems on all other vessels. MI observed a flexible hose connecting a portion of the bilge piping on the starboard side engine room. Renew hose with either a metallic piping material or a rigid non-metallic material. "Old T" 46 CFR 182.40-5(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 3 March 2023
Resolution: Metallic piping installed to replace the non-metallic piping section.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2023
Resolved
At each inspection for certification after the initial inspection, the following examinations shall be made: The setting of the pressure relief valves shall be checked. MI could not check the setting of the pressure relief valve due to the set pressure being painted over. Remove paint in order to determine set pressure or renew valve. Upon determination of pressure or renewal of the valve, conduct test to the satisfaction of an attending MI. "Old T" 46 CFR 176.25-30(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 3 March 2023
Resolution: Intalled new 165psi PRVs on each UPV.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and /or originating in electrical equipment, and reasonably safe from electrical shock of personnel. MI observed an electrical outlet in lounge area forward of the galley with visible burn marks. Renew electrical outlet to the satisfaction of a USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2023
Resolution: Electric receptacle was replaced with a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 February 2023
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. The rail along the aft periphery of the vessel is missing and needs to be installed or replaced to the satisfaction of a Marine Inspector. "Old T" 46 CFR 177.35-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 3 March 2023
Resolution: Installed new rails, tabs and chain rails. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 February 2023
Resolved
Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12 inches. Rail courses are missing in several sections of rail along the periphery of the weather deck and need to be installed at the next Drydock upcoming in May 2023 to the satisfaction of a Marine Inspector. "Old T" 46 CFR 177.35-1(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 3 March 2023
Resolution: Installed new courses. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 February 2023
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. The galley and the accommodation space below the main deck are missing the proper portable fire extinguishers required by Table 181.500(b) and need to be installed. "New T" 46 CFR 181.500(b)
Action required: 10 - Deficiency Rectified
Due 16 February 2023
Resolved 16 February 2023
Resolution: Portable fire extinguishers were installed appropriately.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 16 November 2021
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. When asked to operate the public address system, the system was only operable on the weather decks of the vessel. Vessel shall repair the public address system to be operable throughout all accommodation spaces and spaces normally manned by the crew to the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 16 December 2021
Resolution: Vessel repaired PAS an operational check was satisfactory to attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 November 2019
Resolved
All vessel must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 65 feet in length must also have navigation lights that meet UL 1104. Vessel has portable lights in order to meet Rule 27, however the vessel was unable to prove if the lights are UL 1104. Vessel must provide proof that the portable lights are UL 1104 or obtain lights that are UL 1104.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 22 November 2019
Resolution: Vessel submitted pictures of UL 1104 lights to meet Rule 27.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 November 2018
Resolved
Fire drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. When asked to master and crew were unable to produce records.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 21 November 2018
Resolution: Vessel's master created a drills log book for the record keeping of emergency drills. Entries of previous day's COI Inpsection were recorded.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 November 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enougth scale to make safe navigation possible. No chart corrections had been completed when asked to provide proof of corrections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 10 December 2018
Resolution: Attended vessel, verified system inplace for the monitoring and correcting of charts and publications.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 November 2018
Resolved
Portable and Semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Master and crew when asked could not provide proof of maintenance of portable extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 10 December 2018
Resolution: Attended vessel, master showed receipt of third party inspection of portable and semi-portable extinguishers had been inspected and maintained in accordance with NFPA 10.
Lifesaving › Lifefloat › Lifeline
Issued 2 November 2016
Resolved
01 Life Float had un-serviceable life line anchors, completely deteriorated and tearing off. Vessel was passenger count was reduced to reflect the loss of 01 life float.
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 25 May 2017
Resolution: Vessel replaced all life floats.
Construction/Loadline › Hull › Weld
Issued 10 November 2015
Resolved
Repair cracked welds found during ISE to the satisfication of the attending Marine Inspector. 46CFR 176.25-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 4 December 2015
Resolution: cracked welds were repaired to the satisfaction of the attending Marine Inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 November 2015
Resolved
Provide adequate and suitable emergency lighting in generator and main engine space to the satisfaction of the attending Marine Isnpector. 46 CFR 184.305
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 4 December 2015
Resolution: vessel crew installed adaquate emergency lighting to the satisfaction of the attending marine inspector.
Lifesaving › Buoyant Apparatus › Pendant
Issued 3 January 2011
Resolved
Renew the 3 painter lines on the 3 life floats. Vessel is limited to Lakes Bays and Sounds until repaired.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 5 January 2011
Resolution: Permanent repairs made.
Communications › Radio Communications › EPIRB
Issued 3 January 2011
Resolved
Install a serviced hydrostatic release on the EPIRB. Vessel is limited to 3 nm's from shore until repaired.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 5 January 2011
Resolution: Repaires made.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 January 2011
Resolved
Repair emergency escape hatch from the forward passenger area.
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 5 January 2011
Resolution: Repairs made.
Engineering › Bilge Water Management System › Piping
Issued 3 January 2011
Resolved
Remove flexible hose from bilge suction line in the lazarette.
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 5 January 2011
Resolution: Repairs made.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 December 2010
Resolved
Shaft fractured 2 inches aft of cutlass bearing.
Action required: 705 - Other - as specified
Resolved 6 December 2010
Resolution: Replaced shaft
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 January 2010
Resolved
Reduce pax count to 54 until life jacket is replaced.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 26 January 2010
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 January 2010
Resolved
Replace two fire/heat detection system in E/R.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 26 January 2010
Construction/Loadline › Hull › Weld
Issued 12 January 2010
Resolved
Gouge and reweld fractured weld IWO forepeak and port side midship void.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 26 January 2010
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 12 January 2010
Resolved
CPR certification for 50% of deckhands.
Action required: 705 - Other - as specified
Resolved 29 January 2010
Fire Fighting › Nozzles › Type
Issued 28 April 2009
Resolved
Provide firefighting equipment as per 49 CFR 172.101 to carry Hazmat on deck as per the vsl current COI.
Action required: 705 - Other - as specified
Resolved 12 January 2010
Resolution: In-line proportioner installed satisfactorily.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 December 2008
Resolved
Vessel owners continued to operate the vessel past the expiration date on the COI of 29OCT08 and continued to operate until 01DEC08. Vessel must complete a coi renewal exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2008
Resolution: Vessel ceased operations until a new COI was issued.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 November 2007
Resolved
Provide non-conducting rail for front of board.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 19 November 2007
Resolution: Installed proper wooden hand railing for front of board.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 November 2007
Resolved
4 life jackets need to be replaced.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 19 November 2007
Resolution: Suitable life jackets have been replaced.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2007
Resolved
C/R 18" by 18" plate in main deck IWO port side boarding area.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 19 November 2007
Resolution: Inserted proper 18" x 18" plate in main deck; all sat.
Communications › Radio Communications › EPIRB
Issued 12 November 2004
Resolved
Provide new hyprostatic release to replace expired one on EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2004
Resolution: New hydrostatic release provided.
Construction/Loadline › Hull › Weld
Issued 12 November 2004
Resolved
Gouge and reweld two (2) fractures located in longitudinal side frame below port side engine exhaust.
Due 30 November 2004
Resolved 1 December 2004
Resolution: Fractures gouged and rewelded.
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 12 November 2004
Resolved
Prove proper operation of overspeed device on starboard generator.
Due 30 November 2004
Resolved 1 December 2004
Resolution: Gen overspeed tested sat.
Documentation › Certificates/Documents › FCC SSL
Issued 12 November 2004
Resolved
Provide/Obtain FCC license for vessel operator.
Due 30 November 2004
Resolved 1 December 2004
Resolution: Operator presented Fcc license.
Fire Fighting › Fire Pumps › Pressure
Issued 12 November 2004
Resolved
Demonstrate/show 60psi pressure on discharge side of fire pump with one (1) hose operating.
Due 30 November 2004
Resolved 1 December 2004
Resolution: Fire pump tested sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 November 2004
Resolved
Prove proper operation of installed heat/fire detection system.
Due 30 November 2004
Resolved 1 December 2004
Resolution: System operating correctly.
Documentation › Certificates/Documents
Issued 18 July 2003
Resolved
Vessel is prohibited from operating until COI examination is completed. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Resolved 27 October 2003
Resolution: Temp COI issued.
Construction/Loadline › Hull
Issued 27 May 2003
Resolved
Gouge and re-weld the following fractures: 2 welds, port side, outboard of galley, fracture in engine room overhead, under 3rd from back deck stantion, fractures in port and starboard corners of rudder room. LEGACY COMPONENT DESC: Weld
Due 27 June 2003
Resolved 23 October 2003
Resolution: Noted requirements not cleared from system. Item corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 27 May 2003
Resolved
Install check valve in sewage tank drain line. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 27 June 2003
Resolved 23 October 2003
Resolution: Noted item not cleared. Item corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 May 2003
Resolved
Make forward escape hatch fast to boat (lanyard, hinge, etc). LEGACY COMPONENT DESC: Means of escape
Due 27 June 2003
Resolved 27 October 2003
Resolution: Noted that item not cleared. Item corrected.
Engineering › Bilge Water Management System › Valve
Issued 27 May 2003
Resolved
Demonstrate proper operation to attending C.G. inspector of the forepeak suction valve and reach rod. LEGACY COMPONENT DESC: Valve
Due 3 June 2003
Resolved 16 November 2004
Resolution: Valve operates properly.
Communications › Radio Communications
Issued 16 April 2002
Resolved
Vessel limited to one hundred nautical miles untilfitted with NAVTEX reciever.
Action required: 705 - Other - as specified
Resolved 29 May 2002
Resolution: NAVTEX installed 29MAY02
Construction/Loadline › Hull › Stiffener
Issued 16 April 2002
Resolved
Crop and renew damaged area IWO aft port bits to include bit stiffeners.
Due 16 May 2002
Resolved 19 April 2002
Documentation › Certificates/Documents
Issued 16 April 2002
Resolved
Provide approved stability letter onboard vessel. LEGACY COMPONENT DESC: Stability Letter
Due 16 July 2002
Resolved 11 February 2003
Resolution: Provided a copy of stability letter dated 03 NOV 1978.
Navigation
Issued 9 May 2000
Resolved
Adjust hydraulic ram so it does not continue to force rudders to turn afterrudders have reached their limits.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Navigation
Issued 9 May 2000
Resolved
Loosen wire rope connecting port rudder to the steering compartment overhead.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Accommodation/Occupational Safety
Issued 9 May 2000
Resolved
Provide means to lock MSD overboard discharge handle when operating within 3nm.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Lifesaving
Issued 9 May 2000
Resolved
Properly secure paddles to lifefloat.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Construction/Loadline
Issued 9 May 2000
Resolved
Properly label bilge alarm panel. Current labeling is misleading and does not indicate the spaces where the alarms are located.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Navigation
Issued 10 May 1999
Resolved
PROVIDE CURRENT COMPASS DEVAITION CARD
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 10 May 1999
Resolved
PROPERLY MARK DIRECTION OF CLOSURE ON FWD PEAK BILGE SUCTIONVALVE AND EMG FUEL OIL CUT-OFF VALVE.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
MAKE REPARIS TO FRACTURED WELDS IN AFT STEERING, CNTR HORZ STIFFINER: GENERATOR SPACE,PORT FWD BULK UPPER TUBE HORZ SUPPORT.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 7 July 1998
Resolved
MAKE REPAIRS TO STARBOARD AFT WRAP AROUND BY CROPPING RIP AND RENEW INSERT
Condition: Unknown
Due 22 July 1998
Resolved 17 July 1998
Lifesaving
Issued 7 July 1998
Resolved
PROVIDE APPROVED FIRST AID KIT AND MAKE READILY AVAILABLE TO CREW PER 46 CFR 184.710. REF: 46 CFR 160.041
Condition: Unknown
Due 22 July 1998
Resolved 17 July 1998
Lifesaving
Issued 5 June 1989
Resolved
REPLACE TWO PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Fire Fighting
Issued 5 June 1989
Resolved
REPLACE TWO FIRE HOSES.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Lifesaving
Issued 5 June 1989
Resolved
REPLACE WEAK LINKS ATTACHING LIFEFLOATS.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Electrical
Issued 14 December 1988
Resolved
REPAIR ELECTRICAL LIGHTING SWITCH IN GENERATOR ROOM.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Accommodation/Occupational Safety
Issued 14 December 1988
Resolved
ARRANGE VENTING SYSTEM IN THE ENGINE PROPULSION ROOM & THE S/S GENERATOR ROOM TO CONFORM TO 46CFR182.20-45.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Electrical
Issued 23 September 1986
Resolved
DEMONSTRATE PROPER OPERATION OF STARBOARD GENERATOR OVERSPEED GOVERNOR.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Engineering
Issued 23 September 1986
Resolved
REPAIR FRACTURED UNFIRED PRESSURE VESSEL, MANCHESTER TANK #260272, ON SHELLNEXT TO MOUNT PAD DIRECTLY UNDER DATA PLATE, USING ASME AND USCG APPROVED WELDING PROCEDURES AT A COST GUARD APPROVED FACILITY.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Engineering
Issued 23 September 1986
Resolved
DEMONSTRATE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE UPON REPAIR OF SHELL.
Condition: Unknown
Due 23 September 1986
Resolved 23 September 1986
Lifesaving
Issued 19 September 1984
Resolved
ONE 25 MAN LIFEFLOAT TO BE REPAIRED OR REPLACED.
Condition: Unknown
Due 19 September 1984
Resolved 19 September 1984
Documentation
Issued 19 September 1984
Resolved
POST ALL LICENSES AND PAPERWORK IN WHEELHOUSE.
Condition: Unknown
Due 19 September 1984
Resolved 19 September 1984
Unknown
Issued 19 September 1984
Resolved
BOTH SHIPSERVICE AIR RECEIVERS TO BE INTERNALLY INSPECTED AND RELIEF VALVESTO BE TESTED.
Condition: Unknown
Due 19 September 1984
Resolved 19 September 1984