MAURY USCG vessel records Sign in
← All vessels

C-EXPRESS

C-EXPRESS is a 1999 offshore supply vessel. The Coast Guard has recorded 29 inspections since 1999, most recently in May 2016, along with 42 deficiencies and 2 casualty investigations between 2002 and 2004.

Records from 1999 to 2016. Most recent: inspection, 13 May 2016.

Built
1999
Last inspected
13 May 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8967058 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ2530
499779
Flag
UNITED STATES
—
Maury page id
psix-499779

Inspections, by type

…with no type recorded7
Years with a record 14 calendar years (1999–2016)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 728
ITC dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 728
BuilderN AMERICAN FABRICATOR · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2092 - Convention (Subpart B), Gross Ton
728 - Convention (Subpart B), Net Ton
3263 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KATERINA Freight Ship · MISLE 228928 · 5 December 2002 · activity 1715432NOBLE AMOS RUNNER Mobile Offshore Drilling Unit · MISLE 54095 · 5 October 2000 · activity 38560OCEAN PROJECT Offshore Supply Vessel · MISLE 414345 · 1 August 2000 · activity 104457

Inspection history · 29

13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876320
1 May 2012 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4299715
31 January 2011 Administrative Inspection · ACP Handover Survey · MTSA/ISPS Verification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3936522
13 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3846898
31 July 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3284825
24 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213473
9 July 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2993949
4 February 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2868375
3 February 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2870914
17 August 2006 Hull Examination · Internal Structural Exam · Damage Survey · Welding Related Inspections Qualification Testing · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750561
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750018
2 August 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2733596
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501676
15 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2463704
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293976
22 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2263749
21 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2263721
30 September 2004 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2209661
12 August 2004 MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2163832
26 November 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1954821
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979579
5 December 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1715432
5 November 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1701135
16 August 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1662258
20 August 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070472
14 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418947
5 October 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 38560
1 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 104457
13 August 1999 Deadweight Survey · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369318

Deficiency record · 42

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 13 May 2012 Resolved
Provide properly charged, USCG approved Fire Extinguisher for FRC.
Due 27 May 2012
Resolved 20 June 2012
Fire Fighting › Fire Hoses › Condition
Issued 13 May 2012 Resolved
Provide UL approved Fire Hoses on board.
Due 13 June 2012
Resolved 20 June 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 May 2012 Resolved
Repair Hydraulic leaks on both Z-Drives and clean up Hydraulic Oil.
Due 13 June 2012
Resolved 20 June 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 May 2012 Resolved
Replace 1 chafed Hydraulic Hose on Steering System
Due 13 June 2012
Resolved 20 June 2012
Engineering › Fuel Oil Service System › Hose
Issued 13 May 2012 Resolved
Replace 1 chafed hydraulic hose on Generator
Due 13 June 2012
Resolved 20 June 2012
Stability › Watertight Integrity › General
Issued 13 May 2012 Resolved
Adjust watertight door in engine room.
Due 13 June 2012
Resolved 20 June 2012
Communications › Alarms/Indicators › General Alarm
Issued 13 May 2012 Resolved
Repair watertight door indicator on main deck to engine room.
Due 27 May 2012
Resolved 20 June 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 May 2012 Resolved
Restencil name and hailing port on ringbuoys
Due 13 June 2012
Resolved 20 June 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 May 2012 Resolved
Provide proof of annual hydrostatic test for cargo transfer hoses
Due 27 May 2012
Resolved 20 June 2012
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 July 2008 Resolved
Vessel's OWS did not work properly. Have OWS certified and repaired and show proper operation.
Due 31 August 2008
Resolved 5 August 2008
Engineering › Fuel Oil Service System › Hose
Issued 31 July 2008 Resolved
Replace flex fuel lines on stbd generator feeding and returning going to filter
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2008
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 31 July 2008 Resolved
Replace deteriorated crankcase breather hose feeding back into oil sump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 31 July 2008 Resolved
Dampner for Ventillation did not operate properly, show proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 August 2006 Resolved
Update fire control plan to reflect fire fighting changes on the main deck that are documented on the bridge.
Due 16 August 2006
Resolved 22 August 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 August 2006 Resolved
Label electric galley stove with breaker shutoff location.
Due 16 August 2006
Resolved 22 August 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 August 2006 Resolved
Provide servicing report by 3rd party for proper operation of oily water seperator and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 22 August 2006
Engineering › Pressure Vessel › Relief Valve
Issued 2 August 2006 Resolved
Provide servicing report by 3rd party for testing of pressure vessel relief valves.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 22 August 2006
Communications › Radio Communications › EPIRB
Issued 2 August 2006 Resolved
Change registration of EPIRB to reflect new owners
Due 16 August 2006
Resolved 22 August 2006
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 15 August 2005 Resolved
Provide proper fixed containment for Emerg, generator fuel vent and both port and stbd aft deck rail discharge piping, at next dry docking.
Condition: Design Flaw
Due 16 August 2007
Resolved 17 August 2006
Documentation › Certificates/Documents › FCC SSL
Issued 15 August 2005 Resolved
Renew FCC station license with MMSI for AIS and selective calling radio telephone.
Condition: Placed in Improper Service
Due 17 September 2005
Resolved 2 August 2006
Stability › Weathertight Integrity › General
Issued 25 August 2004 Resolved
Make repairs to wheelhouse door locking mechanism and all watertight doors in terms of security.
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 29 September 2004
Resolution: Wheelhouse doors and all watertight doors are secured properly in terms of security.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 August 2004 Resolved
Provide current compass deviation.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 29 September 2004
Resolution: Vessel provided current compass deviation card.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 August 2004 Resolved
Provide current automation test procedures.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 29 September 2004
Resolution: Vessel provided current automation test procedures. Recommended vessel change oil temperature and pressure readings on engineering checksheet to correlate with approved test procedure.
Fire Fighting › Portable Foam Applicators › General
Issued 17 August 2004 Resolved
Provide Coast Guard approved foam nozzle.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 29 September 2004
Resolution: Vessel provided Coast Guard approved foam equipment. Recommended vessel alter fire stations to allow foam equipment to be readily attachable when installed at fire stations.
Communications › Alarms/Indicators
Issued 26 November 2003 Resolved
Make repairs to general alarm light in aft steering. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2003
Resolved 26 November 2003
Construction/Loadline › Structures
Issued 26 November 2003 Resolved
Adjust all watertight doors as discussed. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2003
Resolved 26 November 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 November 2003 Resolved
Make repairs to Stbd main engine oil leaks. LEGACY COMPONENT DESC: Cylinder Head
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 26 November 2003 Resolved
Reconfigure ventilation system located in the A/C spaces containing batteries. LEGACY COMPONENT DESC: Location
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 25 August 2004
Resolution: Ventilation configured satisfactorily.
Engineering › Fuel Oil Service System
Issued 26 November 2003 Resolved
Renew flexible fuel hose on stbd generator. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Engineering › Compressed Air System (start air)
Issued 26 November 2003 Resolved
Replace relief valve on port air receiver. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 26 November 2003 Resolved
Renew (2) air pipe vent screens on foc'sle. LEGACY COMPONENT DESC: Flame Screens
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Fire Fighting › Ventilation Systems
Issued 26 November 2003 Resolved
Make repairs to pull cord for automatic dampener closure in emergency generator room. LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Electrical › Lighting (emergency)
Issued 26 November 2003 Resolved
Make repairs to emergency light in the emergency generator room. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2003
Resolved 26 November 2003
Lifesaving › Lifejacket/PFD (General)
Issued 26 November 2003 Resolved
Stencil lifejacket in control room. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 26 November 2003 Resolved
Renew expired items in the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 26 January 2004
Lifesaving › Lifejacket/PFD (General)
Issued 26 November 2003 Resolved
Renew lifejacket light in room 204. LEGACY COMPONENT DESC: Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2003
Resolved 26 November 2003
Lifesaving › Lifebuoys
Issued 5 November 2002 Resolved
Stencil lifebuoy towage area, "Lifebuoy". LEGACY COMPONENT DESC: Stowage
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 6 November 2002
Lifesaving › Lifebuoys
Issued 5 November 2002 Resolved
Properly attach lights to lifebuoy's, 3-6 feet of line around the body of the buoy. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 6 November 2002
Navigation › Piloting/Steering
Issued 5 November 2002 Resolved
Provide up to date copy of the Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 6 November 2002
Electrical › Electric Supply System (service)
Issued 5 November 2002 Resolved
Repair reverse power relay on port generator. LEGACY COMPONENT DESC: Reverse Current Protection
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 6 November 2002
Electrical › Electrical Distribution System (emergency)
Issued 5 November 2002 Resolved
Provide for the proper stowage of the batteries located in the ventilation space on the 02 deck. Stowage and vetilation shall be in compliance with 46 CFR 111.15. LEGACY COMPONENT DESC: Battery Stowage
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 26 November 2003
Navigation
Issued 14 August 2001 Resolved
DEMONSTRATE PROPER OPERATION OF THE RECORDING CAPABILITIES OF THE DEPTH SOUNDER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001

Casualty record · 2

5 December 2002Routine · role: Sighted in Area · activity 1715432
21 December 2004Routine · role: Acknowledged Pollution Source · activity 2263721
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.