VALLENAR

VALLENAR is a 1978 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1982, most recently in July 2026, along with 63 deficiencies.

Records from 1982 to 2026. Most recent: inspection, 1 July 2026.

Built
1978
Last inspected
1 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAO4160
Flag
UNITED STATES
367190460
Maury page id
psix-49992

Inspections, by type

…with no type recorded5
Years with a record 37 calendar years (1982–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.3 ft × 14.3 ft × 6.2 ft
Registered tonnagegross 23 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKETCHIKAN, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7733MMSI 367190460 · active · compulsorily equipped · granted 8 March 2017, expires 26 May 2027
WAO4160MMSI not assigned · expired · compulsorily equipped · granted 23 May 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BARANOF DREAM Passenger (Inspected) · MISLE 52041 · 25 August 2003 · activity 1907970

Inspection history · 61

1 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8421537
14 April 2026 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8349721
26 January 2026 Administrative Inspection · Internal Structural Exam · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8303012
4 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8105191
28 February 2025 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8087951
5 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7890440
11 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7666481
8 March 2023 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7647830
20 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7435411
2 March 2021 Deficiency Check · Administrative Inspection · Hull Examination · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7149208
1 May 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6947082
12 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6661524
9 April 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6660754
8 March 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6639069
18 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6397812
21 April 2017 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6130233
15 March 2017 Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6106001
22 March 2016 COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5838139
5 January 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3921472
25 March 2010 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3703029
12 September 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3323589
13 August 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3297492
16 April 2008 Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3185776
16 April 2008 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3194605
27 July 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3009270
18 June 2007 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2966107
29 March 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2897938
2 March 2006 Hull Examination · COI Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2599001
2 May 2005 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2347761
6 April 2004 Periodic Inspection · Hull Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2093711
30 October 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1939288
25 August 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1907970
8 April 2003 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2093468
21 March 2002 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1637271
14 March 2001 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1426689
2 May 2000 Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1436368
27 March 2000 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1408485
1 June 1999 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 804983
26 March 1999 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1454661
5 May 1998 Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1126893
27 March 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1396889
21 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1368262
22 May 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1446361
17 May 1996 Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1416265
28 March 1995 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1371036
31 March 1994 Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1461572
22 April 1993 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1389655
2 April 1992 Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1267485
3 June 1991 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1246939
17 August 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1230273
16 April 1990 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1213268
16 April 1990 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1238910
19 April 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1045227
17 March 1989 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 897447
13 June 1988 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 889238
4 April 1988 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 993471
15 July 1987 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1327574
13 May 1987 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1025177
12 May 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 993903
30 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000719
22 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274450

Deficiency record · 63

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 14 April 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 1 July 2026
Resolution: Locations and numbers have been properly labeled.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 May 2020 Resolved
Prior to carrying passengers conduct man overboard and fire drill's.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2020
Resolved 15 April 2021
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 March 2010 Resolved
Replace bulbs in light fixtures
Due 20 April 2010
Resolved 21 April 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 March 2010 Resolved
Install fire extinguisher brackets for portable fire extinguishers.
Due 20 April 2010
Resolved 21 April 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 March 2010 Resolved
Provide proof of portable fire extinguisher annual servicing.
Due 20 April 2010
Resolved 21 April 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 April 2008 Resolved
Replace hose clamps on raw water intake for both main engines. Hose clamps are to big and do not provide adequate service.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 13 August 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 April 2008 Resolved
Replace water light on life ring.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 13 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 29 April 2008 Resolved
Repair RPM gauge for MDE.
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 13 August 2008
Engineering › Bilge Water Management System › Pump
Issued 29 April 2008 Resolved
Provide portable bilge pump to reach bottom of all compartments.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 13 August 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 June 2007 Resolved
Provide training log book and document monthly EPIRB test.
Due 18 July 2007
Resolved 27 July 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 June 2007 Resolved
Provide current light list for operating area.
Due 18 July 2007
Resolved 27 July 2007
Engineering › Bilge Water Management System › Hose
Issued 18 June 2007 Resolved
Replace and properly align bilge flex connection in engine room.
Due 18 July 2007
Resolved 27 July 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 June 2007 Resolved
Double clamp raw water cooling lines for both main engines.
Due 18 July 2007
Resolved 27 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 18 June 2007 Resolved
Provide FCC radiotelephony safety certificate.
Due 18 July 2007
Resolved 12 September 2008
Engineering › Bilge Water Management System › Piping
Issued 2 March 2006 Resolved
Install inline check valves on each bilge suction line IAW 46CFR (182.25-5).
Action required: 705 - Other - as specified
Due 22 April 2006
Resolved 29 March 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 March 2006 Resolved
Prior to carrying passengers provide currently serviced liferaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2006 Resolved
Replace plastic fuel filter plugs with metal in fuel filters.
Due 22 April 2006
Resolved 29 March 2007
Fire Fighting › Means of Escape › Blocked
Issued 2 March 2006 Resolved
Provide fire axe in forward accommodation space to allow for emergency exit.
Due 22 April 2006
Resolved 29 March 2007
Engineering › Bilge Water Management System › Pump
Issued 2 March 2006 Resolved
Install indicator light at operating station for automatic bilge pump in engine room.
Due 10 April 2006
Resolved 29 March 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 March 2006 Resolved
Replace lanyard on water light for ring buoy.
Due 22 April 2006
Resolved 29 March 2007
Lifesaving › Inflatable Liferafts › Capacity
Issued 2 March 2006 Resolved
Vessel is limited to 12 persons due to 100% life saving requirements. This requirement shall remain in affect until replacement with additional units of increased capacity.
Action required: 705 - Other - as specified
Resolved 18 June 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 May 2005 Resolved
Install suitable electrical junction box for electrical outlet connection on range.
Due 16 May 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 2 May 2005 Resolved
Paint range disconnect switch cover red.
Due 16 May 2005
Resolved 4 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 May 2005 Resolved
Provide life jacket donning placard.
Due 16 May 2005
Resolved 4 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 May 2005 Resolved
Provide suitable guards over rotating engine shafts to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 2 May 2005
Lifesaving › Inflatable Liferafts › Not on Board
Issued 2 May 2005 Resolved
Prior to carrying passengers, install 100% lifesaving devices on board vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2005
Engineering › Bilge Water Management System › Strainer
Issued 6 April 2004 Resolved
In lazarette install bilge alarm properly and prove proper operations.
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 8 June 2004
Resolution: Switch installed and ops proven satisfactory.
Construction/Loadline › Hull
Issued 6 April 2004 Resolved
Repairs required in both port and starboard sides of engine room and lazarette: Crop and renew hull plating IWO keel cooling piping. Gauge plating and replace to good aluminum with minimum insert of 18in x 30in. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 8 June 2004
Resolution: Hull plating replaced from forward bulkhead of engine room to lazeratte on both sides. Insp of welds complete with visual inspection and hyro of channel without indication of leakage.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 April 2003 Resolved
Ensure drill are recorded meeting requirement provided in 185.524(d)
Condition: Invalid
Due 8 April 2003
Resolved 8 April 2003
Resolution: Upon completion of emergency drills proper entry made.
Communications › Radio Communications › EPIRB
Issued 8 April 2003 Resolved
Complete monthly test and log entries for installed EPIRB IAW 46CFR185.728.
Due 8 April 2003
Resolved 8 April 2003
Resolution: Master completed test and made entry.
Operations/Management › Drills/Instruction › Emergency Checkoff List
Issued 8 April 2003 Resolved
Post emergency instructions ensuring procedures accurately reflect policy and procedures.
Condition: Invalid
Due 8 April 2003
Resolved 8 April 2003
Resolution: Instructions posted and drills completed to the satisfaction of the attending CG MI.
Communications › Radio Communications
Issued 8 April 2003 Resolved
Post emergency broadcast placard.
Due 8 April 2003
Resolved 8 April 2003
Resolution: Provided by inspector and posted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 April 2003 Resolved
IAW 46CFR177.900 install deck rails.
Due 8 April 2003
Resolved 8 April 2003
Resolution: Installation of lines witnessed prior to completion of exam.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 April 2003 Resolved
Make battery installation IAW 46CFR183.350.
Due 8 April 2003
Resolved 8 April 2003
Resolution: Batteries installed to boxes with covers meeting requirements.
Lifesaving › Inflatable Liferafts › Capacity
Issued 8 April 2003 Resolved
Vessel is limited to 12 person due to 100% life saving requirements. This requirement shall remain in affect until replacement with additional units of increased capacity.
Action required: 705 - Other - as specified
Due 8 April 2003
Resolved 8 April 2003
Engineering › Bilge Water Management System › Pump
Issued 21 March 2002 Resolved
Prove proper operation of Rule pump and overboard discharge valve. KPB
Due 5 April 2002
Resolved 5 April 2002
Resolution: Valve replaced and new level sw replaced tested sat.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 21 March 2002 Resolved
In accordance with (IAW) 46CFR12.422 (d) double hose clamps required where the approved insertion of short lengths of hose from keel cooling lines or water intake which lead from below water line. KPB
Due 5 April 2002
Resolved 5 April 2002
Resolution: Noted installation on new hose and double clamps.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 21 March 2002 Resolved
Installation on Starboard engine: Properly mount solenoid and replace ground wire. Also remove dead ended wire under center of engine. KPB
Due 5 April 2002
Resolved 5 April 2002
Resolution: Wire replaced and mounted properly. 7 Dead ended wires replaced.
Fire Fighting › Fire Pumps › Arrangement
Issued 21 March 2002 Resolved
Engine room: Repair or replace valves to fire pump and bilge overboard. All valves require maintenance or replacement to ensure operation. Lines IWO overboard valve near starboard skin have large amount of corrosion build up. Wire brush and apply coating to preserve is recommended not required.
Due 5 April 2002
Resolved 5 April 2002
Resolution: Valve replaced and tested sat. Maintenance completed and system in vg condition.
Lifesaving › Lifebuoys › Stowage
Issued 21 March 2002 Resolved
Properly mount life ring and affix lettering off from reflective material. KPB
Due 5 April 2002
Resolved 5 April 2002
Resolution: Inspection of life ring sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 March 2002 Resolved
Replace engine room light globe protection brackets. KPB
Due 5 April 2002
Resolved 5 April 2002
Resolution: Fixture replaced with guard.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 March 2002 Resolved
Remove hose attached to forward bulkhead IWO engine room forward bulkhead and port engine, 6 inches from over head.
Due 5 April 2002
Resolved 5 April 2002
Resolution: Hose removed and cap installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2002 Resolved
Fore peak: Remove dead ended wires/ or install junction box.
Due 5 April 2002
Resolved 5 April 2002
Resolution: Wire may be used in the coming years for light therefore dead ended in box.
Lifesaving
Issued 14 March 2001 Resolved
Replace dilapidated ring lifebuoy.
Condition: Unknown
Due 14 March 2001
Resolved 5 September 2001
Construction/Loadline
Issued 2 May 2000 Resolved
Repair fracture in starboard shaft tube. Gouge out, drill stop, and reweldfracture according to boat builder's recommendations prior to vessel being refloated.
Condition: Unknown
Due 4 May 2000
Resolved 5 May 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
Replace marine sanitation device overboard discharge valve, wasted and pitted beyond repair.
Condition: Unknown
Due 4 May 2000
Resolved 5 May 2000
Construction/Loadline
Issued 2 May 2000 Resolved
Make watertight cable run penetrations through forward engine room bulkhead(five locations).
Condition: Unknown
Due 4 May 2000
Resolved 5 May 2000
Lifesaving
Issued 27 March 2000 Resolved
RING BOUY LIGHT MUST BE ATTACHED TO RING BOUY WITH A 3FT LANYARD AND CORROSION FREE CLIP I.A.W. 46 CFR 181.30-10.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Engineering
Issued 27 March 2000 Resolved
PRIOR TO OPERATIONS WITH PASSENGERS, DEMONSTRATE THE PROPER OPERATION OF THE PORT ENGINE/GEAR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 2000
Resolved 4 April 2000
Fire Fighting
Issued 27 March 2000 Resolved
PROVIDE ADEQUATE VENILLATION CLOSURES FOR ENGINE ROOM VENTS I.A.W. 46CFR 182.465.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Navigation
Issued 27 March 2000 Resolved
PROVIDE LIGHTLIST IN ACCORDANCE WITH 46 C.F.R. 184.420. NLT 27APR00.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Lifesaving
Issued 27 March 2000 Resolved
PRIOR TO OPERATIONS WITH PASSENGERS, ENSURE LIFERAFTS/LIFEFLOATS ON BOARD AND PROPERLY INSTALLED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. I.A.W. 46 CFR 180.200
Condition: Unknown
Due 4 April 2000
Resolved 4 April 2000
Construction/Loadline
Issued 26 March 1999 Resolved
The high level bilge alarm was not installed at the time of the inspection._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Navigation
Issued 26 March 1999 Resolved
VALLENAR was miss coast pilot #8 for the local operating area._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Documentation
Issued 21 April 1997 Resolved
Fax valid proof of drug program enrollment for master and deckhand.
Condition: Unknown
Due 21 April 1997
Resolved 12 June 1997
Navigation
Issued 21 April 1997 Resolved
Procure new charts or update existing charts for operating area.
Condition: Unknown
Due 21 April 1997
Resolved 12 June 1997
Construction/Loadline
Issued 16 April 1990 Resolved
GOUGE AND REWELD CRACK IN ;FWD BULKHEAD IN LAZARETTE IN WAY OF BILGE LINE PENETRATION.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
PLACE ON BOARD ONE (1) ADDITIONAL ADULT SIZED LIFE PRESERVER. VESSEL SHALLCARRY NO MORETHAN 23 PERSONS UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Documentation
Issued 16 April 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
STENCIL CHILD SIZE LIFE PRESERVER STORAGE AREA WITH NUMBER OF CHILD'S LIFE PRESERVERS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
PLACE ON BOARD 6 ORANGE SMOKES.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Documentation
Issued 16 April 1990 Resolved
PLACE ON BOARD FCC RADIOTELEPHONE SAFETY CERTIFICATE AND FCC OPERATOR'S LICENCES.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 16 April 1990 Resolved
REPAIR/REPLACE STEERING GEAR CONNECTING ROD END PIECES.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990

Ownership record